Radiation exposure doses to the surgical team during hip surgery is significantly higher during lateral imaging than posteroanterior imaging: a cadaveric simulation study
Open Access
- 30 November 2023
- journal article
- research article
- Published by Springer Nature in Journal of Occupational Medicine and Toxicology
- Vol. 18 (1) , 1-6
Abstract
Background: Fluoroscopy is indispensable when determining appropriate and effective interventions in orthopedic surgery. On the other hand, there is growing concern about the health hazards of occupational radiation exposure. The aim of this cadaveric simulation study was to measure radiation exposure doses to the surgical team during hip surgery. Methods: We reproduced the intraoperative setting of hip surgery using 7 fresh frozen cadavers (5 male, 2 female) to simulate patients and mannequins to simulate the surgeon, scrub nurse, and anesthesiologist. Six real-time dosimeters were mounted at sites corresponding to the optic lens, thyroid gland, chest, gonads, foot, and hand on each mannequin. The radiation exposure dose to each team member was measured during posteroanterior and lateral fluoroscopic imaging. Results: Radiation exposure doses to the surgeon were significantly higher during 3 min of lateral imaging than during 3 min of posteroanterior imaging at the optic lens (8.1 times higher), thyroid gland (10.3 times), chest (10.8 times), and hand (19.8 times) (p = 0.018, p = 0.018, p = 0.018, and p = 0.018, respectively). During lateral imaging, the radiation doses to the nurse were 0.16, 0.12, 0.09, 0.72, and 0.38 times those to the surgeon at the optic lens, thyroid, chest, gonads, and foot, respectively. The radiation dose to the anesthesiologist was zero at all anatomic sites during posteroanterior imaging and very small during lateral imaging. Conclusions: Radiation exposure dose was significantly higher during lateral imaging up to 19.8 times comparing to the posteroanterior imaging. It is effective to reduce the lateral imaging time for reducing the intraoperative radiation exposure. In addition, appropriate distance from fluoroscopy resulted in very low exposure for nurses and anesthesiologists. Surgeon should pay attention that surgical staff do not get closer than necessary to the irradiation field.Keywords
Funding Information
- JOA-Subsidized Science Project Research 2021
This publication has 23 references indexed in Scilit:
- Radiation Exposure to the Surgeon and Patient During a Fluoroscopic ProcedureSpine, 2016
- JOURNAL CLUB: Cancer Risks in U.S. Radiologic Technologists Working With Fluoroscopically Guided Interventional Procedures, 1994-2008American Journal of Roentgenology, 2016
- Orthopaedic surgeons’ use and knowledge of ionizing radiation during surgical treatment for femoroacetabular impingementKnee Surgery, Sports Traumatology, Arthroscopy, 2015
- Direct Beam Radiation Exposure to Surgeons During Pinning of Supracondylar Humerus FracturesJournal of Pediatric Orthopaedics, 2014
- Leaded Eyeglasses Substantially Reduce Radiation Exposure of the Surgeon’s Eyes During Acquisition of Typical Fluoroscopic Views of the Hip and PelvisJournal of Bone and Joint Surgery, 2013
- Measurements of Surgeonsʼ Exposure to Ionizing Radiation Dose During Intraoperative Use of C-Arm FluoroscopySpine, 2012
- Increased cancer risk among surgeons in an orthopaedic hospitalOccupational Medicine, 2005
- Scattered radiation during fixation of hip fracturesThe Journal of Bone and Joint Surgery. British volume, 2001
- Radiation Exposure to the Orthopaedic Surgical Team During Fluoroscopy: "How Far Away Is Far Enough?"Journal of Orthopaedic Trauma, 1997
- The Risk from Radiation Exposure during Operative X-ray Screening in Hand SurgeryJournal of Hand Surgery (European Volume), 1994