BFB. M. Freitas

B. M. Freitas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


B. M. Freitas has a total of 8 co-authors. Here are the top co-authors by number of shared publications:

  • Claudia Lucia de Pinho Mauricio

    Instituto de Radioproteção e Dosimetria - IRD/CNEN

    3 shared publications
  • W. W. Pereira

    Instituto de Radioproteção e Dosimetria, Av. Salvador Allende, s/n, Recreio, CEP: 22783-127, Rio de Janeiro, RJ, Brazil

    2 shared publications
  • A X da Silva

    Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Av. Horácio Macedo, 2030, Cidade Universitária, Ilha do Fundão, Rio de Janeiro, RJ, Brazil

    1 shared publication
  • A. X. da Silva

    Coordenação dos Programas de Pós Graduação em Engenharia, COPPE/PEN, CEP: 21941-972, Rio de Janeiro, RJ, Brazil

    1 shared publication
  • E. S. Fonseca

    Instituto de Radioproteção e Dosimetria, Av. Salvador Allende, s/n, Recreio, Rio de Janeiro, CEP: 22783-127 RJ, Brazil

    1 shared publication
  • K. C. S. Patrao

    Instituto de Radioproteção e Dosimetria, Av. Salvador Allende, s/n, Recreio, Rio de Janeiro, CEP: 22783-127 RJ, Brazil

    1 shared publication

Latest Publications

  • COMPARISON OF THE NEUTRON ENERGY RESPONSE OF TWO DIFFERENT TLD ALBEDO DOSEMETERS

    by B M Freitas, A X da Silva, W W Pereira, C L P Mauricio

    Albedo dosemeters remain the most used dosemeters in neutron individual monitoring. In Brazil, most of the neutron occupational fields are from radionuclide sources, often without any moderation, where albedo dosemeters have poor energy response. The purpose of this work is to compare the HP(10) energy response of the IRD and ALNOR TLD albedo dosemeter systems, calculated by their modelling with Monte Carlo code MCNPX. Their energy responses are similar, as expected, but the IRD system is about five times more sensitive than the ALNOR one. IRD albedo system can measure the Brazilian monthly recording level of 0.2 mSv, even for bare 252Cf and 241Am–Be neutron fields. On the other hand, the ALNOR system can measure values higher than 0.2 mSv only after huge moderation of theses sources. These results show that IRD TLD albedo is more suitable than the ALNOR one to measure low doses at occupational fields from radionuclide sources.


  • MCNP SIMULATION OF THEHP(10) ENERGY RESPONSE OF A BRAZILIAN TLD ALBEDO NEUTRON INDIVIDUAL DOSEMETER, FROM THERMAL TO 20 MeV

    by B. M. Freitas, M. M. Martins, W. W. Pereira, A. X. da Silva, C. L. P. Mauricio

    The Brazilian Instituto de Radioproteção e Dosimetria (IRD) runs a neutron individual monitoring system with a home-made TLD albedo dosemeter. It has already been characterised and calibrated in some reference fields. However, the complete energy response of this dosemeter is not known, and the calibration factors for all monitored workplace neutron fields are difficult to be obtained experimentally. Therefore, to overcome such difficulties, Monte Carlo simulations have been used. This paper describes the simulation of the HP(10) neutron response of the IRD TLD albedo dosemeter using the MCNPX transport code, for energies from thermal to 20 MeV. The validation of the MCNPX modelling is done comparing the simulated results with the experimental measurements for ISO standard neutron fields of 241Am–Be, 252Cf, 241Am–B and 252Cf(D2O) and also for 241Am–Be source moderated with paraffin and silicone. Bare 252Cf are used for normalisation.


  • Study of neutron scattering contribution on Hp(10) and H*(10) calibration in the Brazilian National Low Scattering Laboratory

    by B. M. Freitas, W. W. Pereira, K. C. S. Patrao, E. S. Fonseca, C. L. P. Mauricio

    The neutron scattering at the Low Scattering Laboratory of the Brazilian National Neutron Laboratory has been studied using three different methods. The measurements have been done with a traceable standard 241Am–Be from source-to-detector distances of 0.52–3.00 m. The obtained results with the variation distance methods are in agreement. Measurements with a large shadow cone are not worth for larger distances due to overshadowing. As the quantity required in a calibration is the response of the device being calibrated to the scattered neutron component in order to subtract this from the total response, for these purposes, the distance variation method must be used for each device. To quantify absolutely the scattering contribution on the quantity rates of fluence, Hp(10) and H*(10) in irradiation procedures, a Bonner sphere spectrometer with the shadow cone was employed. The evaluated scattering correction factor value may be employed for a distance of 1.00 m.