Claudia Lucia de Pinho Mauricio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Claudia Lucia de Pinho Mauricio has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Denison Souza-Santos
Institute for Radiation Protection and Dosimetry, Av. Salvador Allende, s/n, Rio de Janeiro - RJ 22780-160 Brazil
5 shared publications - B. M. Freitas
Programa de Engenharia Nuclear/COPPE, Universidade Federal do Rio de Janeiro, Av. Horácio Macedo, 2030, Cidade Universitária, Ilha do Fundão, Rio de Janeiro, RJ, Brazil
3 shared publications A.X. da Silva
2 shared publicationsE.S. da Fonseca
2 shared publications- Everton Rodrigues Da Silva
Instituto de Radioproteção e Dosimetria (IRD/CNEN) , Brazil
2 shared publications Herica L. R. da Silva
Instituto de Radioproteção e Dosimetria , IRD , Av. Salvador Allende s/n, 22780-160 Rio de Janeiro, RJ , Brazil
2 shared publications
Latest Publications
- Open Access
- 19 July 2018
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 6 (2A (Suppl.)
Analysis of the external doses received by workers involved in the mitigation of the Goiania radiological accident
In 1987, after identification that a stolen head of a Cs-137 radiotherapy irradiator was violated, it starts, in Goiania, the screening of the involved persons, the decontamination and the collection of the radioactive waste. The contaminated areas were isolated and the professionals who worked within these areas received individual film monitors and TLD rings, provided by the Instituto de Radioproteção e Dosimetria of the Comissão Nacional de Energia Nuclear (IRD/CNEN), to evaluate their external dose. The aim of this paper is to present a statistical analysis of the external occupational doses received by this intervention staff. The used data were extracted from the Goiania accident database, maintained by IRD/CNEN. A total of 1091 workers were monitored, some for only a few days and others for almost one year. All the total external occupational doses, received during these works, including the management of the radioactive waste, were lower than the individual annual dose limit of 50 mSv for practices. Only one dose exceeded the value of 20 mSv. Their estimated mean effective doses were about 1.0 mSv, which is the annual dose limit for public exposure. About 80% of the doses were lower than this value. The measured extremity doses were even lower than the measured whole body doses values.
- 19 July 2018
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 6 (2A (Suppl.)
Open AccessAnalysis of the external doses received by workers involved in the mitigation of the Goiania radiological accident
In 1987, after identification that a stolen head of a Cs-137 radiotherapy irradiator was violated, it starts, in Goiania, the screening of the involved persons, the decontamination and the collection of the radioactive waste. The contaminated areas were isolated and the professionals who worked within these areas received individual film monitors and TLD rings, provided by the Instituto de Radioproteção e Dosimetria of the Comissão Nacional de Energia Nuclear (IRD/CNEN), to evaluate their external dose. The aim of this paper is to present a statistical analysis of the external occupational doses received by this intervention staff. The used data were extracted from the Goiania accident database, maintained by IRD/CNEN. A total of 1091 workers were monitored, some for only a few days and others for almost one year. All the total external occupational doses, received during these works, including the management of the radioactive waste, were lower than the individual annual dose limit of 50 mSv for practices. Only one dose exceeded the value of 20 mSv. Their estimated mean effective doses were about 1.0 mSv, which is the annual dose limit for public exposure. About 80% of the doses were lower than this value. The measured extremity doses were even lower than the measured whole body doses values.
- Open Access
- 19 July 2018
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 6 (2A (Suppl.)
Teste de tipo de um sistema de dosimetria TL para monitoração individual de fótons em Hp(10)
Although regulated, the use of HP(10) to estimate the effective dose of photons has not yet been implemented in Brazil. The operational quantity used in the country, temporarily, is the photon dose equivalent (Hx). For the external monitoring of individuals exposed to photons, the IRD uses an automatic TL dosimetry system with individual MTS-N monitors from the RADOS manufacturer, which contains LiF: Mg, Ti TLDs. The objective of this work was to characterize this system for the evaluation of the operational quantity HP(10). The measuring range is 0.2 mSv to 2 Sv, for photon energies from 20 keV to 1250 keV. The type test was done through performance tests for the following characteristics: homogeneity of the monitors, system reproducibility, linearity, temperature and humidity effect, energy and angular dependence, and fading. The acceptance requirements were taken from IEC 62387 standard and IRD-RT 002.01/95 technical regulation. The results show that all requirements have been met, except for the N-25 quality, at the angle of 60°.
- 19 July 2018
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 6 (2A (Suppl.)
Open AccessTeste de tipo de um sistema de dosimetria TL para monitoração individual de fótons em Hp(10)
Although regulated, the use of HP(10) to estimate the effective dose of photons has not yet been implemented in Brazil. The operational quantity used in the country, temporarily, is the photon dose equivalent (Hx). For the external monitoring of individuals exposed to photons, the IRD uses an automatic TL dosimetry system with individual MTS-N monitors from the RADOS manufacturer, which contains LiF: Mg, Ti TLDs. The objective of this work was to characterize this system for the evaluation of the operational quantity HP(10). The measuring range is 0.2 mSv to 2 Sv, for photon energies from 20 keV to 1250 keV. The type test was done through performance tests for the following characteristics: homogeneity of the monitors, system reproducibility, linearity, temperature and humidity effect, energy and angular dependence, and fading. The acceptance requirements were taken from IEC 62387 standard and IRD-RT 002.01/95 technical regulation. The results show that all requirements have been met, except for the N-25 quality, at the angle of 60°.
- 13 April 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 89-93
ALGORITHM BASED ON ARTIFICIAL BEE COLONY FOR UNFOLDING OF NEUTRON SPECTRA OBTAINED WITH BONNER SPHERES
Occupational neutron fields usually have energies from the thermal range to some MeV and the characterization of the spectra is essential for estimation of the radioprotection quantities. Thus, the spectrum must be unfolded based on a limited number of measurements. This study implemented an algorithm based on the bee colonies behavior, named Artificial Bee Colony (ABC), where the intelligent behavior of the bees in search of food is reproduced to perform the unfolding of neutron spectra. The experimental measurements used Bonner spheres and 6LiI (Eu) detector, with irradiations using a thermal neutron flux and three reference fields: 241Am–Be, 252Cf and 252Cf (D2O). The ABC obtained good estimation of the expected spectrum even without previous information and its results were closer to expected spectra than those obtained by the SPUNIT algorithm.
- 13 April 2018
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 89-93
ALGORITHM BASED ON ARTIFICIAL BEE COLONY FOR UNFOLDING OF NEUTRON SPECTRA OBTAINED WITH BONNER SPHERES
Occupational neutron fields usually have energies from the thermal range to some MeV and the characterization of the spectra is essential for estimation of the radioprotection quantities. Thus, the spectrum must be unfolded based on a limited number of measurements. This study implemented an algorithm based on the bee colonies behavior, named Artificial Bee Colony (ABC), where the intelligent behavior of the bees in search of food is reproduced to perform the unfolding of neutron spectra. The experimental measurements used Bonner spheres and 6LiI (Eu) detector, with irradiations using a thermal neutron flux and three reference fields: 241Am–Be, 252Cf and 252Cf (D2O). The ABC obtained good estimation of the expected spectrum even without previous information and its results were closer to expected spectra than those obtained by the SPUNIT algorithm.
- 21 November 2017
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 240-244
COMPARISON OF THE NEUTRON ENERGY RESPONSE OF TWO DIFFERENT TLD ALBEDO DOSEMETERS
Albedo dosemeters remain the most used dosemeters in neutron individual monitoring. In Brazil, most of the neutron occupational fields are from radionuclide sources, often without any moderation, where albedo dosemeters have poor energy response. The purpose of this work is to compare the HP(10) energy response of the IRD and ALNOR TLD albedo dosemeter systems, calculated by their modelling with Monte Carlo code MCNPX. Their energy responses are similar, as expected, but the IRD system is about five times more sensitive than the ALNOR one. IRD albedo system can measure the Brazilian monthly recording level of 0.2 mSv, even for bare 252Cf and 241Am–Be neutron fields. On the other hand, the ALNOR system can measure values higher than 0.2 mSv only after huge moderation of theses sources. These results show that IRD TLD albedo is more suitable than the ALNOR one to measure low doses at occupational fields from radionuclide sources.
- 21 November 2017
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 180 (1-4) , 240-244
COMPARISON OF THE NEUTRON ENERGY RESPONSE OF TWO DIFFERENT TLD ALBEDO DOSEMETERS
Albedo dosemeters remain the most used dosemeters in neutron individual monitoring. In Brazil, most of the neutron occupational fields are from radionuclide sources, often without any moderation, where albedo dosemeters have poor energy response. The purpose of this work is to compare the HP(10) energy response of the IRD and ALNOR TLD albedo dosemeter systems, calculated by their modelling with Monte Carlo code MCNPX. Their energy responses are similar, as expected, but the IRD system is about five times more sensitive than the ALNOR one. IRD albedo system can measure the Brazilian monthly recording level of 0.2 mSv, even for bare 252Cf and 241Am–Be neutron fields. On the other hand, the ALNOR system can measure values higher than 0.2 mSv only after huge moderation of theses sources. These results show that IRD TLD albedo is more suitable than the ALNOR one to measure low doses at occupational fields from radionuclide sources.
- Open Access
- 1 August 2016
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 21 (4) , 66-72
Digital orthodontic radiographic set versus cone-beam computed tomography: an evaluation of the effective dose
Key words: Cone-beam computed tomography; Digital radiograph; Radiation dose.
- 1 August 2016
- Published by FapUNIFESP (SciELO) in Dental Press Journal of Orthodontics
- Vol. 21 (4) , 66-72
Open AccessDigital orthodontic radiographic set versus cone-beam computed tomography: an evaluation of the effective dose
Key words: Cone-beam computed tomography; Digital radiograph; Radiation dose.
- 13 August 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 350-353
MCNP SIMULATION OF THEHP(10) ENERGY RESPONSE OF A BRAZILIAN TLD ALBEDO NEUTRON INDIVIDUAL DOSEMETER, FROM THERMAL TO 20 MeV
The Brazilian Instituto de Radioproteção e Dosimetria (IRD) runs a neutron individual monitoring system with a home-made TLD albedo dosemeter. It has already been characterised and calibrated in some reference fields. However, the complete energy response of this dosemeter is not known, and the calibration factors for all monitored workplace neutron fields are difficult to be obtained experimentally. Therefore, to overcome such difficulties, Monte Carlo simulations have been used. This paper describes the simulation of the HP(10) neutron response of the IRD TLD albedo dosemeter using the MCNPX transport code, for energies from thermal to 20 MeV. The validation of the MCNPX modelling is done comparing the simulated results with the experimental measurements for ISO standard neutron fields of 241Am–Be, 252Cf, 241Am–B and 252Cf(D2O) and also for 241Am–Be source moderated with paraffin and silicone. Bare 252Cf are used for normalisation.
- 13 August 2015
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 170 (1-4) , 350-353
MCNP SIMULATION OF THEHP(10) ENERGY RESPONSE OF A BRAZILIAN TLD ALBEDO NEUTRON INDIVIDUAL DOSEMETER, FROM THERMAL TO 20 MeV
The Brazilian Instituto de Radioproteção e Dosimetria (IRD) runs a neutron individual monitoring system with a home-made TLD albedo dosemeter. It has already been characterised and calibrated in some reference fields. However, the complete energy response of this dosemeter is not known, and the calibration factors for all monitored workplace neutron fields are difficult to be obtained experimentally. Therefore, to overcome such difficulties, Monte Carlo simulations have been used. This paper describes the simulation of the HP(10) neutron response of the IRD TLD albedo dosemeter using the MCNPX transport code, for energies from thermal to 20 MeV. The validation of the MCNPX modelling is done comparing the simulated results with the experimental measurements for ISO standard neutron fields of 241Am–Be, 252Cf, 241Am–B and 252Cf(D2O) and also for 241Am–Be source moderated with paraffin and silicone. Bare 252Cf are used for normalisation.
- Open Access
- 20 April 2015
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 3 (1A)
Análise dos registros de dose ocupacional externa no Brasil
Análise dos registros de dose ocupacional externa no Brasil
- 20 April 2015
- Published by Sociedade Brasileira de Proteção Radiológica - SBPR in Brazilian Journal of Radiation Sciences
- Vol. 3 (1A)
Open AccessAnálise dos registros de dose ocupacional externa no Brasil
Análise dos registros de dose ocupacional externa no Brasil
- 1 December 2014
- Published by Elsevier in Radiation Measurements
- Vol. 71, 456-460
Discussion on sources of uncertainty for two TLD albedo dosimetry systems in a comparison of individual monitors in a reference 241Am–Be field
- 1 December 2014
- Published by Elsevier in Radiation Measurements
- Vol. 71, 456-460
Discussion on sources of uncertainty for two TLD albedo dosimetry systems in a comparison of individual monitors in a reference 241Am–Be field
- 1 December 2014
- Published by Elsevier in Radiation Measurements
- Vol. 71, 442-446
TLD occupational dose distribution study in nuclear medicine
- 1 December 2014
- Published by Elsevier in Radiation Measurements
- Vol. 71, 442-446
TLD occupational dose distribution study in nuclear medicine
- 1 July 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1) , 176-180
Study of neutron scattering contribution on Hp(10) and H*(10) calibration in the Brazilian National Low Scattering Laboratory
The neutron scattering at the Low Scattering Laboratory of the Brazilian National Neutron Laboratory has been studied using three different methods. The measurements have been done with a traceable standard 241Am–Be from source-to-detector distances of 0.52–3.00 m. The obtained results with the variation distance methods are in agreement. Measurements with a large shadow cone are not worth for larger distances due to overshadowing. As the quantity required in a calibration is the response of the device being calibrated to the scattered neutron component in order to subtract this from the total response, for these purposes, the distance variation method must be used for each device. To quantify absolutely the scattering contribution on the quantity rates of fluence, Hp(10) and H*(10) in irradiation procedures, a Bonner sphere spectrometer with the shadow cone was employed. The evaluated scattering correction factor value may be employed for a distance of 1.00 m.
- 1 July 2014
- Published by Oxford University Press (OUP) in Radiation Protection Dosimetry
- Vol. 161 (1) , 176-180
Study of neutron scattering contribution on Hp(10) and H*(10) calibration in the Brazilian National Low Scattering Laboratory
The neutron scattering at the Low Scattering Laboratory of the Brazilian National Neutron Laboratory has been studied using three different methods. The measurements have been done with a traceable standard 241Am–Be from source-to-detector distances of 0.52–3.00 m. The obtained results with the variation distance methods are in agreement. Measurements with a large shadow cone are not worth for larger distances due to overshadowing. As the quantity required in a calibration is the response of the device being calibrated to the scattered neutron component in order to subtract this from the total response, for these purposes, the distance variation method must be used for each device. To quantify absolutely the scattering contribution on the quantity rates of fluence, Hp(10) and H*(10) in irradiation procedures, a Bonner sphere spectrometer with the shadow cone was employed. The evaluated scattering correction factor value may be employed for a distance of 1.00 m.