ARArnab Roy

Arnab Roy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Arnab Roy has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Investigation of Gas Turbine Internal Cooling Using Supercritical CO2—Effect of Surface Roughness and Channel Aspect Ratio

    by Arnab Roy, Matthew Searle, Sridharan Ramesh, Douglas Straub

    Experimental and numerical investigation of internal cooling channels with rib turbulators is presented with sCO2 flow at pressure-20.7MPa and temperature up to 150°C. The effect of channel aspect ratio up to 2:1 on thermal-hydraulic performance is explored in additively manufactured rectangular and square channels, both with and without 60° ribs on the top and bottom sides. The Wilson-plot method is employed to measure channel averaged Nusselt number over a Reynolds number range up to 370,000. The friction factor and the overall thermal performance factor (TPF) are also reported. The computational fluid dynamics (CFD) simulation is performed for the rib-turbulated configurations reported in the experiments. The objective of the numerical study is to gain insight into the local heat transfer augmentation in the ribbed channels varying the aspect ratio, channel configuration, operating conditions and surface roughness. Surface roughness is simulated using sand grain roughness height (Ks) calculated from the experimental data, and a comparison is presented with varying surface roughness heights ranging between Ks = 0 - 40µm. Experimental results indicate that the heat transfer augmentation is negligible in the rectangular channels with ribs on the long side compared to the square channel. However, it is enhanced by 60% in comparison to placing ribs on the shorter side. The TPF remains constant at around 1 for the entire range of Reynolds numbers. The simulation results highlight that increased surface roughness can have a considerable influence on Nusselt number and overall TPF.


  • Investigating Gas Turbine Internal Cooling Using Supercritical CO2 at Higher Reynolds Numbers for Direct Fired Cycle Applications

    by Matthew Searle, Arnab Roy, James Black, Douglas Straub, Sridharan Ramesh

    Experimental and numerical investigations of three variants of internal cooling configurations—dimples only, ribs only, and ribs with dimples have been explored at process conditions (96 °C and 207 bar) with sCO2 as the coolant. The designs were chosen based on advanced internal cooling features typically used for air-breathing gas turbines. The experimental study described utilizes additively manufactured square channels with the cooling features over a range of Reynolds number from 80,000 to 250,000. Nusselt number is experimentally calculated utilizing the Wilson Plot method and three heat transfer characteristics—augmentation in Nusselt number, friction factor, and overall thermal performance factor (TPF) are reported. To explore the effect of surface roughness introduced due to additive manufacturing, two baseline flow cases are considered—a conventional smooth tube and an additively manufactured square tube. A companion computational fluid dynamics (CFD) simulation is also performed for the corresponding cooling configurations reported in the experiments using the Reynolds-averaged Navier–Stokes (RANS) based turbulence model. Both experimental and computational results show increasing Nusselt number augmentation as higher Reynolds numbers are approached, whereas prior work on internal cooling of air-breathing gas turbines predict a decay in the heat transfer enhancement as Reynolds number increases. Comparing cooling features, it is observed that the “ribs only” and “ribs with dimples” configurations exhibit higher Nusselt number augmentation at all Reynolds numbers compared with the “dimples only” and the “no features” configurations. However, the frictional losses are almost an order of magnitude higher in the presence of ribs.


  • Measurement of Convective Heat Transfer Coefficients With Supercritical CO2 Using the Wilson-Plot Technique

    by Jim Black, Doug Straub, Ed Robey, Joe Yip, Sridharan Ramesh, Arnab Roy, Matthew Searle

    This paper describes the measurement of convective heat transfer coefficients and friction factors for sCO2 flowing in a smooth tube and compares the results with published correlations for validation. The paper also describes the Heat Exchange and Experimental Testing (HEET) rig recently designed and built at the U.S. Department of Energy’s (DoE’s) National Energy Technology Laboratory (NETL) in Morgantown, WV. The Wilson-plot technique used for measuring the heat transfer coefficients is described along with the data reduction process. The Wilson-plot technique was chosen as the basis for the design of NETL’s HEET rig. Advantages of the Wilson-plot technique include the (1) ability to measure high convective heat transfer coefficients accurately, (2) ability to measure average heat transfer coefficient for complicated heat exchange geometries like those produced using additive manufacturing, (3) ability to measure heat transfer coefficients on both sides of a heat exchanger independently, and (4) simplicity of experimental setup. Capabilities of the HEET rig include pressure to 24 MPa (3500 psig), temperature to 538 °C (1000 °F), mass flow rate to 1.5 kg/s (3 lb/s), and Re to 500,000. The rig is designed to operate with pure CO2 or a mixture of CO2 and up to 10% N2 by volume to study the impact of gas mixtures typical of direct-fired sCO2 power cycles on the convective heat transfer and pressure drop. Preliminary tests in the HEET rig were performed with smooth stainless-steel tube and pure CO2, and the results were compared with published correlations for Nusselt number (Nu) and friction factor. Over a Reynolds number (Re) range from 58,000 to 228,000, measured Nu was compared to predictions using the Dittus and Boelter equation (Kreith and Bohn, 1993, “Principles of Heat Transfer, West Publishing Company”) within 5% and measured friction factors were compared to predictions using the McAdams correlation (“McAdams, 1954, “Heat Transmission,” 3rd ed., McGraw Hill, New York)” for smooth tube to be within 5%.


  • Investigating Instabilities in a Rotating Detonation Combustor Operating With Natural Gas–Hydrogen Fuel Blend—Effect of Air Preheat and Annulus Width

    by Arnab Roy, Clinton R. Bedick, Donald H. Ferguson, Todd Sidwell, Peter A. Strakey

    Propagation characteristics of a detonation wave in an air-breathing rotating detonation combustor (RDC) using natural gas (NG)–hydrogen fuel blends is presented in this paper. Short-duration (∼up to 6 s) experiments were performed on a 152.4 mm OD uncooled RDC with two different annulus gap widths (5.08 mm and 7.62 mm) over a range of equivalence ratios (0.6–1.0) at varying inlet air temperatures (∼65–204 °C) and NG content (up to 15%) with precombustion operating pressure slightly above ambient. It was observed that the RDC, with an annulus gap width of 5.08 mm, was inherently unstable when NG was added to the hydrogen fuel while operating at precombustion pressures near ambient and at an inlet air temperature of 65 °C. Increasing the annulus gap width to 7.62 mm improved the stability of the detonation wave at similar temperatures and pressure permitting operation with as much as 5% NG by volume. While observed speeds of the detonation waves were still below theoretical values, an increase in inlet air temperature reduced the variability in wave speed. The frequency analysis thus explored in this study is an effort to quantify detonation instability in an RDC under varying operational envelope. The data presented are relevant toward developing strategies to sustain a stable detonation wave in an RDC using NG for land-based power generation.


  • Heat Transfer Performance of a Transonic Turbine Blade Passage in the Presence of Leakage Flow Through Upstream Slot and Mateface Gap With Endwall Contouring

    by Arnab Roy, Sakshi Jain, Srinath V. Ekkad, Wing Ng, Andrew S. Lohaus, Michael E. Crawford, Santosh Abraham

    Comparison of heat transfer performance of a nonaxisymmetric contoured endwall to a planar baseline endwall in the presence of leakage flow through stator–rotor rim seal interface and mateface gap is reported in this paper. Heat transfer experiments were performed on a high turning turbine airfoil passage at Virginia Tech's transonic blow down cascade facility under design conditions for two leakage flow configurations—(1) mateface blowing only, (2) simultaneous coolant injection from the upstream slot and mateface gap. Coolant to mainstream mass flow ratios (MFRs) were 0.35% for mateface blowing only, whereas for combination blowing, a 1.0% MFR was chosen from upstream slot and 0.35% MFR from mateface. A common source of coolant supply to the upstream slot and mateface plenum made sure the coolant temperatures were identical at both upstream slot and mateface gap at the injection location. The contoured endwall geometry was generated to minimize secondary aerodynamic losses. Transient infrared thermography technique was used to measure endwall surface temperature and a linear regression method was developed for simultaneous calculation of heat transfer coefficient (HTC) and adiabatic cooling effectiveness, assuming a one-dimensional (1D) semi-infinite transient conduction. Results indicate reduction in local hot spot regions near suction side as well as area averaged HTC using the contoured endwall compared to baseline endwall for all coolant blowing cases. Contoured geometry also shows better coolant coverage further along the passage. Detailed interpretation of the heat transfer results along with near endwall flow physics has also been discussed.


  • Effect of Endwall Contouring on a Transonic Turbine Blade Passage: Heat Transfer Performance

    by Kapil V. Panchal, Santosh Abraham, Arnab Roy, Srinath V. Ekkad, Wing Ng, Andrew S. Lohaus, Michael E. Crawford

    Effect of turbine endwall contouring on its aerodynamic performance has been widely studied, but only a few studies are available in the open literature investigating its effect on heat transfer performance; especially at transonic exit Mach number conditions. In this paper, we report a study of effect of contouring on endwall heat transfer performance of a high-turning high-pressure (HP) turbine blade passage operating under transonic exit conditions. The paper describes comparison of heat transfer performance of two contoured endwall geometries, one aerodynamically optimized (AO) and the other heat transfer optimized (HTO), with a baseline, noncontoured geometry. The endwall geometries were experimentally investigated at Virginia Tech's transient, blow down, transonic linear cascade facility at three exit Mach numbers, Mex= 0.71, 0.88(design) and 0.95, for their heat transfer performance. Endwall surface temperatures were measured using infrared (IR) thermography and local heat transfer coefficient (HTC) values were calculated using measured temperatures. A camera matrix model-based data postprocessing technique was developed to relate the two-dimensional images captured by IR camera to three-dimensional endwall contours. The measurement technique and the methodology for postprocessing of the heat transfer coefficient data have been presented in detail. Discussion and interpretation of experimental results have been augmented using aerodynamic CFD simulations of the geometries. Both the contoured endwalls demonstrated a significant reduction in the overall average heat transfer coefficient values of the order of 10%. The surface Stanton number distributions also indicated a reduction in the level of hot spots for most of the endwall surface. However, at some locations an increase was also observed, especially in the area near the leading edge (LE). The results indicate that the endwall contouring could significantly improve heat transfer performance of turbine passages.