Chih-Han Chang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Chih-Han Chang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Yen-Nien Chen
Department of Physical Therapy, Asia University, Taichung 413, Taiwan
8 shared publications - Chih-Wei Chang
Department of Orthopaedics, National Cheng Kung University Hospital, Tainan, Taiwan; Division of Orthopaedics, Department of Medicine, College of Medicine, National Cheng Kung University, Tainan, Taiwan
6 shared publications - Chun-Ting Li
Graduate Institute of Mechatronic System Engineering, National University of Tainan, Tainan City, Taiwan
5 shared publications - Yao-Te Peng
Department of Biomedical Engineering, National Cheng Kung University, Tainan City, Taiwan
4 shared publications - Chi-Rung Chung
Department of Orthopedics, Chi-Mei Medical Center, Tainan, Taiwan
3 shared publications - Chia-Jung Chang
Department of Biomedical Engineering, National Cheng Kung University, Tainan, Taiwan
2 shared publications
Latest Publications
- Open Access
- 10 February 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12  (2) , 253
Numerical Comparison of Restored Vertebral Body Height after Incomplete Burst Fracture of the Lumbar Spine
Background and objectives: Vertebral compression fracture is a major health care problem worldwide due to its direct and indirect negative influence on health-related quality of life and increased health care costs. Although a percutaneous surgical intervention with balloon kyphoplasty or metal expansion, the SpineJack, along with bone cement augmentation has been shown to efficiently restore and fix the lost vertebral height, 21â30% vertebral body height loss has been reported in the literature. Furthermore, the effect of the augmentation approaches and the loss of body height on the biomechanical responses in physiological activities remains unclear. Hence, this study aimed to compare the mechanical behavior of the fractured lumbar spine with different restored body heights, augmentation approaches, and posterior fixation after kyphoplasty using the finite element method. Furthermore, different augmentation approaches with bone cement and bone cement along with the SpineJack were also considered in the simulation. Materials and Methods: A numerical lumbar model with an incomplete burst fracture at L3 was used in this study. Two different degrees of restored body height, namely complete and incomplete restorations, after kyphoplasty were investigated. Furthermore, two different augmentation approaches of the fractured vertebral body with bone cement and SpineJack along with bone cement were considered. A posterior instrument (PI) was also used in this study. Physiological loadings with 400 N + 10 Nm in four directions, namely flexion, extension, lateral bending, and axial rotation, were applied to the lumbar spine with different augmentation approaches for comparison. Results: The results indicated that both the bone cement and bone cement along with the SpineJack could support the fractured vertebral body to react similarly with an intact lumbar spine under identical loadings. When the fractured body height was incompletely restored, the peak stress in the L2âL3 disk above the fractured vertebral body increased by 154% (from 0.93 to 2.37 MPa) and 116% (from 0.18 to 0.39 MPa), respectively, in the annular ground substance and nucleus when compared with the intact one. The use of the PI could reduce the range of motion and facet joint force at the implanted levels but increase the facet joint force at the upper level of the PI. Conclusions: In the present study, complete restoration of the body height, as possible in kyphoplasty, is suggested for the management of lumbar vertebral fractures.
- 10 February 2022
- Published by MDPI AG in Journal of Personalized Medicine
- Vol. 12  (2) , 253
Open AccessNumerical Comparison of Restored Vertebral Body Height after Incomplete Burst Fracture of the Lumbar Spine
Background and objectives: Vertebral compression fracture is a major health care problem worldwide due to its direct and indirect negative influence on health-related quality of life and increased health care costs. Although a percutaneous surgical intervention with balloon kyphoplasty or metal expansion, the SpineJack, along with bone cement augmentation has been shown to efficiently restore and fix the lost vertebral height, 21â30% vertebral body height loss has been reported in the literature. Furthermore, the effect of the augmentation approaches and the loss of body height on the biomechanical responses in physiological activities remains unclear. Hence, this study aimed to compare the mechanical behavior of the fractured lumbar spine with different restored body heights, augmentation approaches, and posterior fixation after kyphoplasty using the finite element method. Furthermore, different augmentation approaches with bone cement and bone cement along with the SpineJack were also considered in the simulation. Materials and Methods: A numerical lumbar model with an incomplete burst fracture at L3 was used in this study. Two different degrees of restored body height, namely complete and incomplete restorations, after kyphoplasty were investigated. Furthermore, two different augmentation approaches of the fractured vertebral body with bone cement and SpineJack along with bone cement were considered. A posterior instrument (PI) was also used in this study. Physiological loadings with 400 N + 10 Nm in four directions, namely flexion, extension, lateral bending, and axial rotation, were applied to the lumbar spine with different augmentation approaches for comparison. Results: The results indicated that both the bone cement and bone cement along with the SpineJack could support the fractured vertebral body to react similarly with an intact lumbar spine under identical loadings. When the fractured body height was incompletely restored, the peak stress in the L2âL3 disk above the fractured vertebral body increased by 154% (from 0.93 to 2.37 MPa) and 116% (from 0.18 to 0.39 MPa), respectively, in the annular ground substance and nucleus when compared with the intact one. The use of the PI could reduce the range of motion and facet joint force at the implanted levels but increase the facet joint force at the upper level of the PI. Conclusions: In the present study, complete restoration of the body height, as possible in kyphoplasty, is suggested for the management of lumbar vertebral fractures.
- Open Access
- 14 November 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21  (1) , 1-11
Role of an additional third screw in the fixation of transverse patellar fracture with two parallel cannulated screw and anterior wire
BackgroundTwo parallel cannulated screws along with an anterior wire to construct a tension band is a popular approach in transverse patellar fractures. However, the optimal screw proximity, either deep or superficial screw placements, remains controversial. Hence, a new concept of the addition of a third screw to form a triangular configuration along with the original two parallel screws was proposed in this study. Therefore, the biomechanical effect of the additional third screw on the stability of the fractured patella was investigated with finite element (FE) simulation.MethodsAn FE knee model including the distal femur, proximal tibia, and fractured patella (type AT/OTA 34-C) was developed in this study. Four different screw configurations, including two parallel cannulated screws with superficial (5-mm proximity) and deep (10-mm proximity) placements and two parallel superficial screws plus a third deep screw, and two parallel deep screws plus a third superficial screw, with or without the anterior wire, were considered for the simulation.ResultsResults indicated that the addition of a third screw increased stability by reducing the dorsal gap opening when two parallel screws were deeply placed, particularly on the fractured patella without an anterior wire. However, the third screw was of little value when two parallel screws were superficially placed. In the existence of two deep parallel screws and the anterior wire, the third screw reduced the gap opening by 23.5% (from 1.15mm to 0.88mm) and 53.6% (from 1.21mm to 0.61mm) in knee flexion 45 degrees and full extension, respectively. Furthermore, in the absence of the anterior wire, the third screw reduced the gap opening by 73.5% (from 2mm to 0.53mm) and 72.2% (from 1.33mm to 0.37mm) in knee flexion 45 degrees and full extension, respectively.ConclusionBased on the results, a third cannulated screw superficially placed (5-mm proximity) is recommended to increase stability and maintain contact of the fractured patella, fixed with two parallel cannulated screws deeply placed (10-mm proximity), particularly when an anterior wire was not used. Furthermore, the third screw deeply placed is not recommended in a fractured patella with two parallel superficial screws.
- 14 November 2020
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 21  (1) , 1-11
Open AccessRole of an additional third screw in the fixation of transverse patellar fracture with two parallel cannulated screw and anterior wire
BackgroundTwo parallel cannulated screws along with an anterior wire to construct a tension band is a popular approach in transverse patellar fractures. However, the optimal screw proximity, either deep or superficial screw placements, remains controversial. Hence, a new concept of the addition of a third screw to form a triangular configuration along with the original two parallel screws was proposed in this study. Therefore, the biomechanical effect of the additional third screw on the stability of the fractured patella was investigated with finite element (FE) simulation.MethodsAn FE knee model including the distal femur, proximal tibia, and fractured patella (type AT/OTA 34-C) was developed in this study. Four different screw configurations, including two parallel cannulated screws with superficial (5-mm proximity) and deep (10-mm proximity) placements and two parallel superficial screws plus a third deep screw, and two parallel deep screws plus a third superficial screw, with or without the anterior wire, were considered for the simulation.ResultsResults indicated that the addition of a third screw increased stability by reducing the dorsal gap opening when two parallel screws were deeply placed, particularly on the fractured patella without an anterior wire. However, the third screw was of little value when two parallel screws were superficially placed. In the existence of two deep parallel screws and the anterior wire, the third screw reduced the gap opening by 23.5% (from 1.15mm to 0.88mm) and 53.6% (from 1.21mm to 0.61mm) in knee flexion 45 degrees and full extension, respectively. Furthermore, in the absence of the anterior wire, the third screw reduced the gap opening by 73.5% (from 2mm to 0.53mm) and 72.2% (from 1.33mm to 0.37mm) in knee flexion 45 degrees and full extension, respectively.ConclusionBased on the results, a third cannulated screw superficially placed (5-mm proximity) is recommended to increase stability and maintain contact of the fractured patella, fixed with two parallel cannulated screws deeply placed (10-mm proximity), particularly when an anterior wire was not used. Furthermore, the third screw deeply placed is not recommended in a fractured patella with two parallel superficial screws.
- Open Access
- 14 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15  (1) , 1-9
Computational comparison of different plating strategies in medial open-wedge high tibial osteotomy with lateral hinge fractures
Background: Lateral hinge fracture (LHF) is associated with nonunion and plate breakage in high tibial osteotomy (HTO). Mechanical studies investigating fixation strategies for LHFs to restore stability and avoid plate breakage are absent. This study used computer simulation to compare mechanical stabilities in HTO for different LHFs fixed with medial and bilateral locking plates. Methods: A finite element knee model was created with HTO and three types of LHF, namely T1, T2, and T3 fractures, based on the Takeuchi classification. Either medial plating or bilateral plating was used to fix the HTO with LHFs. Furthermore, the significance of the locking screw at the combi hole (D-hole) of the medial TomoFix plate was evaluated. Results: The osteotomy gap shortening distance increased from 0.53 to 0.76, 0.79, and 0.72 mm after T1, T2, and T3 LHFs, respectively, with medial plating only. Bilateral plating could efficiently restore stability and maintain the osteotomy gap. Furthermore, using the D-hole screw reduced the peak stress on the medial plate by 28.7% (from 495 to 353 MPa), 26.6% (from 470 to 345 MPa), and 32.6% (from 454 to 306 MPa) in T1, T2, and T3 LHFs, respectively. Conclusion: Bilateral plating is a recommended strategy to restore HTO stability in LHFs. Furthermore, using a D-hole locking screw is strongly recommended to reduce the stress on the medial plate for lowering plate breakage risk.
- 14 September 2020
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 15  (1) , 1-9
Open AccessComputational comparison of different plating strategies in medial open-wedge high tibial osteotomy with lateral hinge fractures
Background: Lateral hinge fracture (LHF) is associated with nonunion and plate breakage in high tibial osteotomy (HTO). Mechanical studies investigating fixation strategies for LHFs to restore stability and avoid plate breakage are absent. This study used computer simulation to compare mechanical stabilities in HTO for different LHFs fixed with medial and bilateral locking plates. Methods: A finite element knee model was created with HTO and three types of LHF, namely T1, T2, and T3 fractures, based on the Takeuchi classification. Either medial plating or bilateral plating was used to fix the HTO with LHFs. Furthermore, the significance of the locking screw at the combi hole (D-hole) of the medial TomoFix plate was evaluated. Results: The osteotomy gap shortening distance increased from 0.53 to 0.76, 0.79, and 0.72 mm after T1, T2, and T3 LHFs, respectively, with medial plating only. Bilateral plating could efficiently restore stability and maintain the osteotomy gap. Furthermore, using the D-hole screw reduced the peak stress on the medial plate by 28.7% (from 495 to 353 MPa), 26.6% (from 470 to 345 MPa), and 32.6% (from 454 to 306 MPa) in T1, T2, and T3 LHFs, respectively. Conclusion: Bilateral plating is a recommended strategy to restore HTO stability in LHFs. Furthermore, using a D-hole locking screw is strongly recommended to reduce the stress on the medial plate for lowering plate breakage risk.
- Open Access
- 24 April 2019
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 18  (1) , 49
Biomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture
Although use of a dynamic hip screw (DHS) for stable intertrochanteric hip fracture fixation has been successfully applied in fracture healing for more than 20 years, DHS fixation on unstable intertrochanteric fractures still has a high failure rate, especially in patients with osteoporosis. Although the wire fixation is usually incorporated with orthopedic device to treat fracture, the wiring techniques are developed through experiences. Thus, this study is objective to investigate the biomechanical property of different wire fixation methods incorporated with DHS system to provide the lesser trochanter fragment stable fixation on osteoporotic TypeA2.1 fracture for enhancing stability after bone reduction. Sawbone testing results demonstrated higher maximum load, stiffness, and energy in a DHS with wire fixation compared with DHS fixation only. In static biomechanical testing of a cadaver femur, we compared the stiffness of five fixation models and then tested a fatigue failure model in cycle loading with DHS fixation only. Wiring fixation can enhance stability and the cut-out failure model in the fatigue test was identical to the clinical failure model. Lesser trochanteric fragment fixation is a crucial concern in the stability of an A2.1 unstable fracture, and the combination of a wiring technique with a DHS seems beneficial for achieving better stability. The addition of an antirotational greater trochanter is likely to enhance stability through wiring of the greater trochanter.
- 24 April 2019
- Published by Springer Nature in BioMedical Engineering OnLine
- Vol. 18  (1) , 49
Open AccessBiomechanical investigation of dynamic hip screw and wire fixation on an unstable intertrochanteric fracture
Although use of a dynamic hip screw (DHS) for stable intertrochanteric hip fracture fixation has been successfully applied in fracture healing for more than 20 years, DHS fixation on unstable intertrochanteric fractures still has a high failure rate, especially in patients with osteoporosis. Although the wire fixation is usually incorporated with orthopedic device to treat fracture, the wiring techniques are developed through experiences. Thus, this study is objective to investigate the biomechanical property of different wire fixation methods incorporated with DHS system to provide the lesser trochanter fragment stable fixation on osteoporotic TypeA2.1 fracture for enhancing stability after bone reduction. Sawbone testing results demonstrated higher maximum load, stiffness, and energy in a DHS with wire fixation compared with DHS fixation only. In static biomechanical testing of a cadaver femur, we compared the stiffness of five fixation models and then tested a fatigue failure model in cycle loading with DHS fixation only. Wiring fixation can enhance stability and the cut-out failure model in the fatigue test was identical to the clinical failure model. Lesser trochanteric fragment fixation is a crucial concern in the stability of an A2.1 unstable fracture, and the combination of a wiring technique with a DHS seems beneficial for achieving better stability. The addition of an antirotational greater trochanter is likely to enhance stability through wiring of the greater trochanter.
- 8 April 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 68  (1) , 57-64
Gap between the fragment and the tibia affects the stability of tibial tubercle osteotomy: A finite element study
Tibial tubercle osteotomy (TTO) is commonly performed in cases of complicated juxta-articular trauma or revision total knee arthroplasty. However, strategies for firmly fixing the resulting osteotomy bone fragment are not sufficiently understood. This study aims to investigate the effect of the location of the gap between the fragment and the tibia and with various fixed screw configurations on TTO stability, contact force on the fragment, and bone stress by using the finite element method. A TTO model with a 1-mm gap, either above or below the fragment, was developed. Furthermore, five screw configurations, including two parallel horizontal screws placed at 20- and 30-mm intervals, two parallel downward screws, two trapezoid screws, and two divergent screws, were used. A vertically upward 1600-N force was applied on the tibial tubercle to mimic a worst-case condition. Placing the fragment close to the superior cutting plane (above the gap) yielded greater stability and less stress on the bone than did placing it close to the inferior cutting plane. The superior cutting plane of the tibia generated the largest contact force on the superior plane of the fragment for static balance under loading. Additionally, among all screw configurations, the configuration involving two parallel downward screws resulted in the highest stability but also the greatest stress on the cortical bone. The fragment obtains a solid barrier and support from the tibia immediately after surgery to against the patellar tension force when the fragment is close to the superior cutting plane of the tibia.
- 8 April 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 68  (1) , 57-64
Gap between the fragment and the tibia affects the stability of tibial tubercle osteotomy: A finite element study
Tibial tubercle osteotomy (TTO) is commonly performed in cases of complicated juxta-articular trauma or revision total knee arthroplasty. However, strategies for firmly fixing the resulting osteotomy bone fragment are not sufficiently understood. This study aims to investigate the effect of the location of the gap between the fragment and the tibia and with various fixed screw configurations on TTO stability, contact force on the fragment, and bone stress by using the finite element method. A TTO model with a 1-mm gap, either above or below the fragment, was developed. Furthermore, five screw configurations, including two parallel horizontal screws placed at 20- and 30-mm intervals, two parallel downward screws, two trapezoid screws, and two divergent screws, were used. A vertically upward 1600-N force was applied on the tibial tubercle to mimic a worst-case condition. Placing the fragment close to the superior cutting plane (above the gap) yielded greater stability and less stress on the bone than did placing it close to the inferior cutting plane. The superior cutting plane of the tibia generated the largest contact force on the superior plane of the fragment for static balance under loading. Additionally, among all screw configurations, the configuration involving two parallel downward screws resulted in the highest stability but also the greatest stress on the cortical bone. The fragment obtains a solid barrier and support from the tibia immediately after surgery to against the patellar tension force when the fragment is close to the superior cutting plane of the tibia.
- Open Access
- 4 March 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20  (1) , 99
Roles of the screw types, proximity and anterior band wiring in the surgical fixation of transverse patellar fractures: a finite element investigation
Cannulated screws with an anterior wire are currently used for managing transverse patellar fracture. However, the addition of anterior wiring with various types of screws via open surgery to increase the mechanical stability is yet to be determined. Hence, this study aimed to compare the mechanical behaviors of a fractured patella fixed with various screws types and at various screw locations with and without the anterior wire. The present study hypothesized that using the anterior wire reduces the fracture gap formation. A finite element (FE) model containing a fractured patella fixed with various types of cannulated screws and anterior wiring was created in this study. Three types of screws, namely partial thread, full thread, and headless compression screws, and two screw depths, namely 5 and 10 mm away from the anterior surface of the patella, were included. The effect of the anterior wire was clarified by comparing the results of surgical fixation with and without the wire. Two magnitudes and two loading directions were used to simulate and examine the mechanical responses of the fractured patella with various fixation conditions during knee flexion/extension. Compared with partial thread and headless compression screws, the full thread screw increased the stability of the fractured patella by reducing fragment displacement, fracture gap formation, and contact pressure while increasing the contact area at the fracture site. Under 400-N in the direction 45°, the full thread screw with 5-mm placement reduced the gap formation by 86.7% (from 2.71 to 0.36 mm) and 55.6% (from 0. 81 to 0. 36 mm) compared with the partial thread screw with 10-mm placement, respectively without and with the anterior wire. The anterior wire along with the full thread screw is preferentially recommended for maintaining the surgical fixation of the fractured patella. Without the use of anterior wiring, the full thread screw with 5-mm placement may be considered as a less invasive alternative; however, simple screw fixation at a deeper placement (10 mm) is least recommended for the fixation of transverse patellar fracture.
- 4 March 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20  (1) , 99
Open AccessRoles of the screw types, proximity and anterior band wiring in the surgical fixation of transverse patellar fractures: a finite element investigation
Cannulated screws with an anterior wire are currently used for managing transverse patellar fracture. However, the addition of anterior wiring with various types of screws via open surgery to increase the mechanical stability is yet to be determined. Hence, this study aimed to compare the mechanical behaviors of a fractured patella fixed with various screws types and at various screw locations with and without the anterior wire. The present study hypothesized that using the anterior wire reduces the fracture gap formation. A finite element (FE) model containing a fractured patella fixed with various types of cannulated screws and anterior wiring was created in this study. Three types of screws, namely partial thread, full thread, and headless compression screws, and two screw depths, namely 5 and 10 mm away from the anterior surface of the patella, were included. The effect of the anterior wire was clarified by comparing the results of surgical fixation with and without the wire. Two magnitudes and two loading directions were used to simulate and examine the mechanical responses of the fractured patella with various fixation conditions during knee flexion/extension. Compared with partial thread and headless compression screws, the full thread screw increased the stability of the fractured patella by reducing fragment displacement, fracture gap formation, and contact pressure while increasing the contact area at the fracture site. Under 400-N in the direction 45°, the full thread screw with 5-mm placement reduced the gap formation by 86.7% (from 2.71 to 0.36 mm) and 55.6% (from 0. 81 to 0. 36 mm) compared with the partial thread screw with 10-mm placement, respectively without and with the anterior wire. The anterior wire along with the full thread screw is preferentially recommended for maintaining the surgical fixation of the fractured patella. Without the use of anterior wiring, the full thread screw with 5-mm placement may be considered as a less invasive alternative; however, simple screw fixation at a deeper placement (10 mm) is least recommended for the fixation of transverse patellar fracture.
- Open Access
- 28 January 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14  (1) , 1-8
Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation
To maintain the corrected alignment after high tibial osteotomy (HTO), fixation with titanium locking plate and screws is widely used in current practice; however, screw breakage is a common complication. Thus, this study was to investigate the mechanical stability of HTO with locking plate and various screw fixations, including the length as well as the type. A finite element (FE) model involving a distal femur, meniscus, and a proximal tibia with HTO fixed with a titanium locking plate and screws was created. The angle of the medial open wedge was 12°, and bone graft was not used. Two types of screws, namely conventional locking and far-cortical locking screws, with various lengths and configurations were used. At the proximal tibia, conventional locking screws with different lengths, 30 and 55 mm, were used; at the tibia shaft, different screw fixations including one-cortical, two-cortical, and far-cortical locking screws were used. The use of far-cortical locking screw generated the highest equivalent stress on the screws, which was four times (from 137.3 to 541 MPa) higher than that of the one-cortical screw. Also, it led to the maximum deformation of the tibia and a greater gap deformation at the osteotomy site, which was twice (from 0.222 to 0.442 mm) larger than that of the one-cortical screw. The effect of different locking screw length on tibia deformation and implant stress was minor. Thus, far-cortical locking screws and plates increase interfragmentary movement but the screw stress is relatively high. Increasing the protection time (partial weight duration) is suggested to decrease the risk of screw breakage in HTO through fixation with titanium far-cortical locking screws and plates.
- 28 January 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14  (1) , 1-8
Open AccessBiomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation
To maintain the corrected alignment after high tibial osteotomy (HTO), fixation with titanium locking plate and screws is widely used in current practice; however, screw breakage is a common complication. Thus, this study was to investigate the mechanical stability of HTO with locking plate and various screw fixations, including the length as well as the type. A finite element (FE) model involving a distal femur, meniscus, and a proximal tibia with HTO fixed with a titanium locking plate and screws was created. The angle of the medial open wedge was 12°, and bone graft was not used. Two types of screws, namely conventional locking and far-cortical locking screws, with various lengths and configurations were used. At the proximal tibia, conventional locking screws with different lengths, 30 and 55 mm, were used; at the tibia shaft, different screw fixations including one-cortical, two-cortical, and far-cortical locking screws were used. The use of far-cortical locking screw generated the highest equivalent stress on the screws, which was four times (from 137.3 to 541 MPa) higher than that of the one-cortical screw. Also, it led to the maximum deformation of the tibia and a greater gap deformation at the osteotomy site, which was twice (from 0.222 to 0.442 mm) larger than that of the one-cortical screw. The effect of different locking screw length on tibia deformation and implant stress was minor. Thus, far-cortical locking screws and plates increase interfragmentary movement but the screw stress is relatively high. Increasing the protection time (partial weight duration) is suggested to decrease the risk of screw breakage in HTO through fixation with titanium far-cortical locking screws and plates.
- Open Access
Comparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures
Elastic nails made of the nickel-titanium shape memory alloy (Nitinol) have been reported to control bone modeling in animal studies. However, the mechanical stability of the Nitinol nail in the fixation of long bone fractures remains unclear. This study compared mechanical stability among nails made of three materials, namely Nitinol, titanium, and stainless steel, in the fixation of long bone fractures. These three materials had identical shapes (arc length: Ď/2 and radius: 260 mm). A cylindrical sawbone with a 10-mm gap and fixed with two C-shaped elastic nails was used to examine the stability of the nails. A finite element (FE) model was developed based on the sawbone model. The end cap for elastic nails was not used in the sawbone test but was considered based on a constraint equation in FE simulation. The results of stability tests appeared to depend on the presence or absence of the end cap. In the sawbone test, the titanium nail yielded a higher ultimate force against the applied load than did the stainless steel and Nitinol nails before the gap completely closed; the difference in linear stiffness between the nails was nonsignificant. In FE simulation, the titanium nail produced smaller gap shortening than did stainless steel and Nitinol nails without the end cap; the difference in gap shortening between the nails was minor with the end cap. The titanium elastic nail should be a better choice in managing diaphyseal long bone fractures when the end cap is not used. For Nitinol and stainless steel nails, the end cap should be used to stop the nail from dropping out and to stabilize the fractured bone.
Open AccessComparison of Mechanical Stability of Elastic Titanium, Nickel-Titanium, and Stainless Steel Nails Used in the Fixation of Diaphyseal Long Bone Fractures
Elastic nails made of the nickel-titanium shape memory alloy (Nitinol) have been reported to control bone modeling in animal studies. However, the mechanical stability of the Nitinol nail in the fixation of long bone fractures remains unclear. This study compared mechanical stability among nails made of three materials, namely Nitinol, titanium, and stainless steel, in the fixation of long bone fractures. These three materials had identical shapes (arc length: Ď/2 and radius: 260 mm). A cylindrical sawbone with a 10-mm gap and fixed with two C-shaped elastic nails was used to examine the stability of the nails. A finite element (FE) model was developed based on the sawbone model. The end cap for elastic nails was not used in the sawbone test but was considered based on a constraint equation in FE simulation. The results of stability tests appeared to depend on the presence or absence of the end cap. In the sawbone test, the titanium nail yielded a higher ultimate force against the applied load than did the stainless steel and Nitinol nails before the gap completely closed; the difference in linear stiffness between the nails was nonsignificant. In FE simulation, the titanium nail produced smaller gap shortening than did stainless steel and Nitinol nails without the end cap; the difference in gap shortening between the nails was minor with the end cap. The titanium elastic nail should be a better choice in managing diaphyseal long bone fractures when the end cap is not used. For Nitinol and stainless steel nails, the end cap should be used to stop the nail from dropping out and to stabilize the fractured bone.
- 24 January 2017
- Published by Springer Nature in International Orthopaedics
- Vol. 41  (7) , 1471-1480
Numerical investigation of fracture impaction in proximal humeral fracture fixation with locking plate and intramedullary nail
Fracture impaction is a surgical technique used to support the fractured humerus with locking plate or intramedullary nail when treating proximal humeral fractures. However, few studies have investigated the mechanical difference between fracture impaction with locking plate and with intramedullary nail. The mechanism of fracture impaction to increase stability is still unclear. The aim of this study was to use numerical methods to compare the biomechanical effect of treating proximal humeral fracture. Six different humerus models, including intact and fractured humeri with various fixation patterns were used in this study. Fracture impaction was simulated by moving the distal fragment of the humeral shift upwards directly until touching the inferior surface of the proximal fragment. We also considered both poor- and normal-quality bone in the simulation. Results confirmed that fracture impaction increases fracture stabilityand decreases peak stress in both implant and bone. Also, fracture impaction and plating with medial shift of the humeral shaft provides the highest stability. The metallic implant shared loading with the bone in the impacted models, while implants sustained all the loading alone in the nonimpacted models. Based on the results, the technique of fracture impaction is suggested for both nail and plate to reduce stresses on bone and implants and to increase structural stability. Furthermore, impaction with medial shift of the humeral shaft with plate is found to achieve the highest stability when treating proximal humeral fractures.
- 24 January 2017
- Published by Springer Nature in International Orthopaedics
- Vol. 41  (7) , 1471-1480
Numerical investigation of fracture impaction in proximal humeral fracture fixation with locking plate and intramedullary nail
Fracture impaction is a surgical technique used to support the fractured humerus with locking plate or intramedullary nail when treating proximal humeral fractures. However, few studies have investigated the mechanical difference between fracture impaction with locking plate and with intramedullary nail. The mechanism of fracture impaction to increase stability is still unclear. The aim of this study was to use numerical methods to compare the biomechanical effect of treating proximal humeral fracture. Six different humerus models, including intact and fractured humeri with various fixation patterns were used in this study. Fracture impaction was simulated by moving the distal fragment of the humeral shift upwards directly until touching the inferior surface of the proximal fragment. We also considered both poor- and normal-quality bone in the simulation. Results confirmed that fracture impaction increases fracture stabilityand decreases peak stress in both implant and bone. Also, fracture impaction and plating with medial shift of the humeral shaft provides the highest stability. The metallic implant shared loading with the bone in the impacted models, while implants sustained all the loading alone in the nonimpacted models. Based on the results, the technique of fracture impaction is suggested for both nail and plate to reduce stresses on bone and implants and to increase structural stability. Furthermore, impaction with medial shift of the humeral shaft with plate is found to achieve the highest stability when treating proximal humeral fractures.