Yao-Te Peng
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yao-Te Peng has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Chun-Ting Li
Graduate Institute of Mechatronic System Engineering, National University of Tainan, Tainan City, Taiwan
6 shared publications - Yen-Nien Chen
Department of Physical Therapy, Asia University, Taichung 413, Taiwan
6 shared publications - Chih-Wei Chang
Department of Orthopaedics, National Cheng Kung University Hospital, Tainan, Taiwan; Division of Orthopaedics, Department of Medicine, College of Medicine, National Cheng Kung University, Tainan, Taiwan
5 shared publications - Chih-Han Chang
Department of BioMedical Engineering, National Cheng Kung University, No.1, University Road, Tainan City, 701, Taiwan
4 shared publications - Chi-Rung Chung
Department of Orthopedics, Chi-Mei Medical Center, Tainan, Taiwan
3 shared publications - Chih-Hsien Chen
Department of Orthopaedic Surgery, Tainan Municipal Hospital (Managed by Show Chwan Medical Care Corporation), Tainan, Taiwan
1 shared publication
Latest Publications
- Open Access
- 1 September 2019
- Published by Elsevier in Journal of Dental Sciences
- Vol. 14 (3) , 288-294
Evaluation of marginal adaptation of Co Cr Mo metal crowns fabricated by traditional method and computer-aided technologies
- 1 September 2019
- Published by Elsevier in Journal of Dental Sciences
- Vol. 14 (3) , 288-294
Open AccessEvaluation of marginal adaptation of Co Cr Mo metal crowns fabricated by traditional method and computer-aided technologies
- 8 April 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 68 (1) , 57-64
Gap between the fragment and the tibia affects the stability of tibial tubercle osteotomy: A finite element study
Tibial tubercle osteotomy (TTO) is commonly performed in cases of complicated juxta-articular trauma or revision total knee arthroplasty. However, strategies for firmly fixing the resulting osteotomy bone fragment are not sufficiently understood. This study aims to investigate the effect of the location of the gap between the fragment and the tibia and with various fixed screw configurations on TTO stability, contact force on the fragment, and bone stress by using the finite element method. A TTO model with a 1-mm gap, either above or below the fragment, was developed. Furthermore, five screw configurations, including two parallel horizontal screws placed at 20- and 30-mm intervals, two parallel downward screws, two trapezoid screws, and two divergent screws, were used. A vertically upward 1600-N force was applied on the tibial tubercle to mimic a worst-case condition. Placing the fragment close to the superior cutting plane (above the gap) yielded greater stability and less stress on the bone than did placing it close to the inferior cutting plane. The superior cutting plane of the tibia generated the largest contact force on the superior plane of the fragment for static balance under loading. Additionally, among all screw configurations, the configuration involving two parallel downward screws resulted in the highest stability but also the greatest stress on the cortical bone. The fragment obtains a solid barrier and support from the tibia immediately after surgery to against the patellar tension force when the fragment is close to the superior cutting plane of the tibia.
- 8 April 2019
- Published by IOP Publishing in Medical Engineering & Physics
- Vol. 68 (1) , 57-64
Gap between the fragment and the tibia affects the stability of tibial tubercle osteotomy: A finite element study
Tibial tubercle osteotomy (TTO) is commonly performed in cases of complicated juxta-articular trauma or revision total knee arthroplasty. However, strategies for firmly fixing the resulting osteotomy bone fragment are not sufficiently understood. This study aims to investigate the effect of the location of the gap between the fragment and the tibia and with various fixed screw configurations on TTO stability, contact force on the fragment, and bone stress by using the finite element method. A TTO model with a 1-mm gap, either above or below the fragment, was developed. Furthermore, five screw configurations, including two parallel horizontal screws placed at 20- and 30-mm intervals, two parallel downward screws, two trapezoid screws, and two divergent screws, were used. A vertically upward 1600-N force was applied on the tibial tubercle to mimic a worst-case condition. Placing the fragment close to the superior cutting plane (above the gap) yielded greater stability and less stress on the bone than did placing it close to the inferior cutting plane. The superior cutting plane of the tibia generated the largest contact force on the superior plane of the fragment for static balance under loading. Additionally, among all screw configurations, the configuration involving two parallel downward screws resulted in the highest stability but also the greatest stress on the cortical bone. The fragment obtains a solid barrier and support from the tibia immediately after surgery to against the patellar tension force when the fragment is close to the superior cutting plane of the tibia.
- Open Access
- 4 March 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 99
Roles of the screw types, proximity and anterior band wiring in the surgical fixation of transverse patellar fractures: a finite element investigation
Cannulated screws with an anterior wire are currently used for managing transverse patellar fracture. However, the addition of anterior wiring with various types of screws via open surgery to increase the mechanical stability is yet to be determined. Hence, this study aimed to compare the mechanical behaviors of a fractured patella fixed with various screws types and at various screw locations with and without the anterior wire. The present study hypothesized that using the anterior wire reduces the fracture gap formation. A finite element (FE) model containing a fractured patella fixed with various types of cannulated screws and anterior wiring was created in this study. Three types of screws, namely partial thread, full thread, and headless compression screws, and two screw depths, namely 5 and 10 mm away from the anterior surface of the patella, were included. The effect of the anterior wire was clarified by comparing the results of surgical fixation with and without the wire. Two magnitudes and two loading directions were used to simulate and examine the mechanical responses of the fractured patella with various fixation conditions during knee flexion/extension. Compared with partial thread and headless compression screws, the full thread screw increased the stability of the fractured patella by reducing fragment displacement, fracture gap formation, and contact pressure while increasing the contact area at the fracture site. Under 400-N in the direction 45°, the full thread screw with 5-mm placement reduced the gap formation by 86.7% (from 2.71 to 0.36 mm) and 55.6% (from 0. 81 to 0. 36 mm) compared with the partial thread screw with 10-mm placement, respectively without and with the anterior wire. The anterior wire along with the full thread screw is preferentially recommended for maintaining the surgical fixation of the fractured patella. Without the use of anterior wiring, the full thread screw with 5-mm placement may be considered as a less invasive alternative; however, simple screw fixation at a deeper placement (10 mm) is least recommended for the fixation of transverse patellar fracture.
- 4 March 2019
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 20 (1) , 99
Open AccessRoles of the screw types, proximity and anterior band wiring in the surgical fixation of transverse patellar fractures: a finite element investigation
Cannulated screws with an anterior wire are currently used for managing transverse patellar fracture. However, the addition of anterior wiring with various types of screws via open surgery to increase the mechanical stability is yet to be determined. Hence, this study aimed to compare the mechanical behaviors of a fractured patella fixed with various screws types and at various screw locations with and without the anterior wire. The present study hypothesized that using the anterior wire reduces the fracture gap formation. A finite element (FE) model containing a fractured patella fixed with various types of cannulated screws and anterior wiring was created in this study. Three types of screws, namely partial thread, full thread, and headless compression screws, and two screw depths, namely 5 and 10 mm away from the anterior surface of the patella, were included. The effect of the anterior wire was clarified by comparing the results of surgical fixation with and without the wire. Two magnitudes and two loading directions were used to simulate and examine the mechanical responses of the fractured patella with various fixation conditions during knee flexion/extension. Compared with partial thread and headless compression screws, the full thread screw increased the stability of the fractured patella by reducing fragment displacement, fracture gap formation, and contact pressure while increasing the contact area at the fracture site. Under 400-N in the direction 45°, the full thread screw with 5-mm placement reduced the gap formation by 86.7% (from 2.71 to 0.36 mm) and 55.6% (from 0. 81 to 0. 36 mm) compared with the partial thread screw with 10-mm placement, respectively without and with the anterior wire. The anterior wire along with the full thread screw is preferentially recommended for maintaining the surgical fixation of the fractured patella. Without the use of anterior wiring, the full thread screw with 5-mm placement may be considered as a less invasive alternative; however, simple screw fixation at a deeper placement (10 mm) is least recommended for the fixation of transverse patellar fracture.
- Open Access
- 28 January 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-8
Biomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation
To maintain the corrected alignment after high tibial osteotomy (HTO), fixation with titanium locking plate and screws is widely used in current practice; however, screw breakage is a common complication. Thus, this study was to investigate the mechanical stability of HTO with locking plate and various screw fixations, including the length as well as the type. A finite element (FE) model involving a distal femur, meniscus, and a proximal tibia with HTO fixed with a titanium locking plate and screws was created. The angle of the medial open wedge was 12°, and bone graft was not used. Two types of screws, namely conventional locking and far-cortical locking screws, with various lengths and configurations were used. At the proximal tibia, conventional locking screws with different lengths, 30 and 55 mm, were used; at the tibia shaft, different screw fixations including one-cortical, two-cortical, and far-cortical locking screws were used. The use of far-cortical locking screw generated the highest equivalent stress on the screws, which was four times (from 137.3 to 541 MPa) higher than that of the one-cortical screw. Also, it led to the maximum deformation of the tibia and a greater gap deformation at the osteotomy site, which was twice (from 0.222 to 0.442 mm) larger than that of the one-cortical screw. The effect of different locking screw length on tibia deformation and implant stress was minor. Thus, far-cortical locking screws and plates increase interfragmentary movement but the screw stress is relatively high. Increasing the protection time (partial weight duration) is suggested to decrease the risk of screw breakage in HTO through fixation with titanium far-cortical locking screws and plates.
- 28 January 2019
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 14 (1) , 1-8
Open AccessBiomechanical investigation of the type and configuration of screws used in high tibial osteotomy with titanium locking plate and screw fixation
To maintain the corrected alignment after high tibial osteotomy (HTO), fixation with titanium locking plate and screws is widely used in current practice; however, screw breakage is a common complication. Thus, this study was to investigate the mechanical stability of HTO with locking plate and various screw fixations, including the length as well as the type. A finite element (FE) model involving a distal femur, meniscus, and a proximal tibia with HTO fixed with a titanium locking plate and screws was created. The angle of the medial open wedge was 12°, and bone graft was not used. Two types of screws, namely conventional locking and far-cortical locking screws, with various lengths and configurations were used. At the proximal tibia, conventional locking screws with different lengths, 30 and 55 mm, were used; at the tibia shaft, different screw fixations including one-cortical, two-cortical, and far-cortical locking screws were used. The use of far-cortical locking screw generated the highest equivalent stress on the screws, which was four times (from 137.3 to 541 MPa) higher than that of the one-cortical screw. Also, it led to the maximum deformation of the tibia and a greater gap deformation at the osteotomy site, which was twice (from 0.222 to 0.442 mm) larger than that of the one-cortical screw. The effect of different locking screw length on tibia deformation and implant stress was minor. Thus, far-cortical locking screws and plates increase interfragmentary movement but the screw stress is relatively high. Increasing the protection time (partial weight duration) is suggested to decrease the risk of screw breakage in HTO through fixation with titanium far-cortical locking screws and plates.
- Open Access
- 9 December 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 496
Comparing the effects of different dynamic sitting strategies in wheelchair seating on lumbar-pelvic angle
Prolonged static sitting in a wheelchair is associated with an increased risk of lower back pain. The wheelchair seating system is a key factor of this risk because it affects spinal loading in the sitting position. In this study, 7 dynamic sitting strategies (DSSs) are examined: lumbar prominent dynamic sitting (LPDS), back reclined dynamic sitting (BRDS), femur upward dynamic sitting (FUDS), lumbar prominent with back reclined dynamic sitting (LBDS), lumbar prominent with femur upward dynamic sitting (LFDS), back reclined with femur upward dynamic sitting (BFDS), and lumbar prominent with back reclined with femur upward dynamic sitting (LBFDS). The objective of this study was to analyze the biomechanical effects of these sitting strategies on lumbar-pelvic angles. Twenty able-bodied participants were recruited for the study. All participants performed LPDS, BRDS, FUDS, LBDS, LFDS, BFDS, and LBFDS in a random order. All lumbar-pelvic angle parameters, including the static lumbar angle, static pelvic angle, lumbar range of motion, and pelvic range of motion were measured and compared. Results show that LBDS and LBFDS enabled the most beneficial lumbar movements, although the difference between the 2 strategies was nonsignificant. BRDS and BFDS enabled the most beneficial pelvic movements, although the difference between the 2 strategies was nonsignificant. Among all the upright DSSs, LPDS and LFDS enabled the most beneficial lumbar and pelvic movements, although no significant difference was observed between these 2 strategies. We identified the effects and differences among 7 DSSs on lumbar-pelvic angles. Wheelchair users can choose the most suitable DSS that meets their needs. These findings may serve as a reference for practicing physicians or wheelchair users to choose an appropriate dynamic wheelchair seating system. ISRCTN12389808 , 18th November 2016, retrospectively registered.
- 9 December 2016
- Published by Springer Nature in BMC Musculoskeletal Disorders
- Vol. 17 (1) , 496
Open AccessComparing the effects of different dynamic sitting strategies in wheelchair seating on lumbar-pelvic angle
Prolonged static sitting in a wheelchair is associated with an increased risk of lower back pain. The wheelchair seating system is a key factor of this risk because it affects spinal loading in the sitting position. In this study, 7 dynamic sitting strategies (DSSs) are examined: lumbar prominent dynamic sitting (LPDS), back reclined dynamic sitting (BRDS), femur upward dynamic sitting (FUDS), lumbar prominent with back reclined dynamic sitting (LBDS), lumbar prominent with femur upward dynamic sitting (LFDS), back reclined with femur upward dynamic sitting (BFDS), and lumbar prominent with back reclined with femur upward dynamic sitting (LBFDS). The objective of this study was to analyze the biomechanical effects of these sitting strategies on lumbar-pelvic angles. Twenty able-bodied participants were recruited for the study. All participants performed LPDS, BRDS, FUDS, LBDS, LFDS, BFDS, and LBFDS in a random order. All lumbar-pelvic angle parameters, including the static lumbar angle, static pelvic angle, lumbar range of motion, and pelvic range of motion were measured and compared. Results show that LBDS and LBFDS enabled the most beneficial lumbar movements, although the difference between the 2 strategies was nonsignificant. BRDS and BFDS enabled the most beneficial pelvic movements, although the difference between the 2 strategies was nonsignificant. Among all the upright DSSs, LPDS and LFDS enabled the most beneficial lumbar and pelvic movements, although no significant difference was observed between these 2 strategies. We identified the effects and differences among 7 DSSs on lumbar-pelvic angles. Wheelchair users can choose the most suitable DSS that meets their needs. These findings may serve as a reference for practicing physicians or wheelchair users to choose an appropriate dynamic wheelchair seating system. ISRCTN12389808 , 18th November 2016, retrospectively registered.