Bital Savir-Baruch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Bital Savir-Baruch has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
Robert H. Wagner
Department of Radiology, Loyola University Medical Center, Maywood, USA
3 shared publications- Lovrec Petra
Loyola University Medical Center, United States
2 shared publications Abhishek A. Solanki
Department of Radiation Oncology, Loyola University Medical Center, Maywood, USA
1 shared publicationAndrea Varrone
1 shared publication- Ari Goldberg
Department of Radiology, Loyola University Medical Center, 2160, South 1st Avenue, Maywood, IL 60153, United States of America
1 shared publication - Carla Martins Abreu
B's Research Group, I3Bs ‐ Research Institute on Biomaterials, Biodegradables and Biomimetics University of Minho, Headquarters of the European Institute of Excellence on Tissue Engineering and Regenerative Medicine, AvePark, Parque de Ciência e Tecnologia, Zona Industrial da Gandra Guimarães Portugal
1 shared publication
Latest Publications
- 1 December 2024
- Published by European Association of Nuclear Medicine
PET tracers beyond [18F]FDG
- 3 September 2021
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 24 (1) , 42-49
Positivity Rate of [18F]Fluciclovine PET/CT in Patients with Suspected Prostate Cancer Recurrence at PSA Levels Below 1 ng/mL
Purpose Early and precise localization of recurrent prostate cancer lesions after local therapy facilitates optimal disease management. Here, we present results from a single-center study to evaluate the utility of [18F]fluciclovine PET/CT to localize prostate cancer recurrence in patients with PSA 18F]fluciclovine PET/CT (August 2016–March 2020) for suspected recurrent prostate cancer and who had a PSA value n=3) and a perirectal mass implant (n=1). Conclusions Despite low PSA values, more than half of patients had positive [18F]fluciclovine PET/CT findings. Patients with low PSA levels may demonstrate suspicious findings outside of the pelvis, including abdominal lymph nodes and metastatic disease to bones and lungs.
- 3 September 2021
- Published by Springer Nature in Molecular Imaging and Biology
- Vol. 24 (1) , 42-49
Positivity Rate of [18F]Fluciclovine PET/CT in Patients with Suspected Prostate Cancer Recurrence at PSA Levels Below 1 ng/mL
Purpose Early and precise localization of recurrent prostate cancer lesions after local therapy facilitates optimal disease management. Here, we present results from a single-center study to evaluate the utility of [18F]fluciclovine PET/CT to localize prostate cancer recurrence in patients with PSA 18F]fluciclovine PET/CT (August 2016–March 2020) for suspected recurrent prostate cancer and who had a PSA value n=3) and a perirectal mass implant (n=1). Conclusions Despite low PSA values, more than half of patients had positive [18F]fluciclovine PET/CT findings. Patients with low PSA levels may demonstrate suspicious findings outside of the pelvis, including abdominal lymph nodes and metastatic disease to bones and lungs.
- Open Access
- 11 October 2019
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 48 (1) , 24-29
Characterizing and Mitigating Bladder Radioactivity on 18F-Fluciclovine PET/CT
Purpose: F-18-fluciclovine PET is approved for prostate cancer recurrence imaging. According to the radiopharmaceutical package insert only 3% of the tracer is expected to be excreted in the urine over the first four hours. Yet, in clinical practice we noticed a higher percentage of bladder excretion. We sought to evaluate and quantify early fluciclovine bladder radioactivity and determine if refraining from voiding before fluciclovine injection would mitigate it. Materials and Methods: 159 patients underwent fluciclovine PET/CT imaging as part of their clinical workup. The first 36 patients were instructed to void just before fluciclovine injection, the subsequent 123 patients were not requested to void. The SUVmax and SUVmean of the bladder, aorta, marrow, liver, and bladder volumes were collected. Comparing SUVmean of bladder to background, we characterized bladder radioactivity as: "Insignificant" (bladder < aorta), "Mild" (bladder > aorta, < marrow), "Moderate" (bladder > marrow, < liver) and "Intense" (bladder > liver). Differences between the protocols were investigated. Results: Overall, 22% (35/159) of patients had moderate, and 8.8% (14/159) had intense bladder activity. A negative association was found between bladder volumes and SUVmean. A significant difference was found between voiding and non-voiding protocol groups, with 38.9% (14/36) vs. 17.1% (21/123) of patients having moderate, and 22.2% (8/36) vs. 4.9% (6/123) of patients having intense bladder activity, respectively. Conclusion: Refraining from voiding prior to F-18-fluciclovine injection results in significantly lower urinary bladder radioactivity compared to purposeful voiding pre-injection. We have modified our practice accordingly, particularly as moderate and intense bladder activity may mask/mimic local prostate cancer recurrence. Mechanisms underlying this phenomenon should be further investigated.
- 11 October 2019
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 48 (1) , 24-29
Open AccessCharacterizing and Mitigating Bladder Radioactivity on 18F-Fluciclovine PET/CT
Purpose: F-18-fluciclovine PET is approved for prostate cancer recurrence imaging. According to the radiopharmaceutical package insert only 3% of the tracer is expected to be excreted in the urine over the first four hours. Yet, in clinical practice we noticed a higher percentage of bladder excretion. We sought to evaluate and quantify early fluciclovine bladder radioactivity and determine if refraining from voiding before fluciclovine injection would mitigate it. Materials and Methods: 159 patients underwent fluciclovine PET/CT imaging as part of their clinical workup. The first 36 patients were instructed to void just before fluciclovine injection, the subsequent 123 patients were not requested to void. The SUVmax and SUVmean of the bladder, aorta, marrow, liver, and bladder volumes were collected. Comparing SUVmean of bladder to background, we characterized bladder radioactivity as: "Insignificant" (bladder < aorta), "Mild" (bladder > aorta, < marrow), "Moderate" (bladder > marrow, < liver) and "Intense" (bladder > liver). Differences between the protocols were investigated. Results: Overall, 22% (35/159) of patients had moderate, and 8.8% (14/159) had intense bladder activity. A negative association was found between bladder volumes and SUVmean. A significant difference was found between voiding and non-voiding protocol groups, with 38.9% (14/36) vs. 17.1% (21/123) of patients having moderate, and 22.2% (8/36) vs. 4.9% (6/123) of patients having intense bladder activity, respectively. Conclusion: Refraining from voiding prior to F-18-fluciclovine injection results in significantly lower urinary bladder radioactivity compared to purposeful voiding pre-injection. We have modified our practice accordingly, particularly as moderate and intense bladder activity may mask/mimic local prostate cancer recurrence. Mechanisms underlying this phenomenon should be further investigated.
- Open Access
- 10 June 2019
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 47 (4) , 282-287
Best Practices for 18F-Fluciclovine PET/CT Imaging of Recurrent Prostate Cancer: A Guide for Technologists
F-18-fluciclovine is a Food and Drug Administration-approved PET tracer indicated for patients suspected to have recurrent prostate cancer based on a prostate-specific antigen rise after prior therapy. F-18-fluciclovine PET/CT is performed significantly differently from F-18-FDG PET/CT and requires special attention to patient preparation, injection technique, and imaging time. This article aims to provide nuclear medicine technologists with the best-practice guidelines for the F-18-fluciclovine PET/CT protocol.
- 10 June 2019
- Published by Society of Nuclear Medicine in Journal of Nuclear Medicine Technology
- Vol. 47 (4) , 282-287
Open AccessBest Practices for 18F-Fluciclovine PET/CT Imaging of Recurrent Prostate Cancer: A Guide for Technologists
F-18-fluciclovine is a Food and Drug Administration-approved PET tracer indicated for patients suspected to have recurrent prostate cancer based on a prostate-specific antigen rise after prior therapy. F-18-fluciclovine PET/CT is performed significantly differently from F-18-FDG PET/CT and requires special attention to patient preparation, injection technique, and imaging time. This article aims to provide nuclear medicine technologists with the best-practice guidelines for the F-18-fluciclovine PET/CT protocol.
- 13 April 2019
- Published by Springer Nature in Current Radiology Reports
- Vol. 7 (6) , 1-11
Emerging Role of Fluciclovine and Other Next Generation PET Imaging Agents in Prostate Cancer Management
- 13 April 2019
- Published by Springer Nature in Current Radiology Reports
- Vol. 7 (6) , 1-11
Emerging Role of Fluciclovine and Other Next Generation PET Imaging Agents in Prostate Cancer Management
- 1 April 2017
- Published by Elsevier in PET Clinics
- Vol. 12 (2) , 145-157
Imaging of Prostate Cancer Using Fluciclovine
- 1 April 2017
- Published by Elsevier in PET Clinics
- Vol. 12 (2) , 145-157
Imaging of Prostate Cancer Using Fluciclovine