Ari Goldberg
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ari Goldberg has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Anugayathri Jawahar
Department of Radiology, Abdominal Imaging Division, Northwestern University-Feinberg School of Medicine, Chicago
1 shared publication - Bital Savir-Baruch
Department of Radiology, Loyola University Medical Center, Maywood, USA
1 shared publication Brian Thomsen
Department of Medicine, GE Healthcare, Waukesha, WI
1 shared publication- Cara Joyce
Department of Medicine, Stritch School of Medicine, Loyola University Chicago, 2160 S 1st Ave, Maywood, IL 60153, USA
1 shared publication - Elizabeth Henry
Division of Hematology/Oncology, Loyola University Medical Center, Maywood, USA
1 shared publication - Funmilayo Tade
Department of Radiology, Loyola University Medical Center, Maywood, USA
1 shared publication
Latest Publications
- 3 September 2022
- Published by Elsevier in Clinical Imaging
- Vol. 91, 126-131
Safety profile of Gadoterate meglumine on the renal function of patients with severe kidney disease
- 3 September 2022
- Published by Elsevier in Clinical Imaging
- Vol. 91, 126-131
Safety profile of Gadoterate meglumine on the renal function of patients with severe kidney disease
- 12 March 2021
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 45 (3) , 403-407
Validation of Second-Generation Motion-Correction Software for Computed Tomography Coronary Angiography With Novel Quantitative Approach
Introduction: Computed tomography of the coronary arteries (CTCA) is an important diagnostic tool. However, motion degradation is sometimes a challenge to interpretation and quantification, particularly with elevated heart rates. Here, a novel quantitative method is presented as part of an evaluation of one particular motion correction algorithm. Methods: Computed tomography of the coronary arteries scans from 49 patients, with heart rates of >70 bpm, were identified with motion artifacts in multiple coronary segments. At these foci (196), an objective measure of motion degradation, defined here by cross-section eccentricity, was determined before and after image processing with second-generation GE SnapShot Freeze software (SSF-2.0). In addition, a subjective scoring was applied by an expert cardiothoracic radiologist both before and after processing. Results: An overall decrease in vessel eccentricity strongly correlated (P < 0.001) with processing of the images by motion-correction software. A concurrent overall increase in subjective vessel clarity correlated (P < 0.001) with application of the software as well. Conclusions: A novel quantitative method (and subjective analysis) for evaluation of CTCA motion has been described and applied to validation of SSF-2.0 motion-correction software. Both the technique and software demonstrate promise for robust clinical utility in CTCA evaluation.
- 12 March 2021
- Published by Wolters Kluwer Health in Journal of Computer Assisted Tomography
- Vol. 45 (3) , 403-407
Validation of Second-Generation Motion-Correction Software for Computed Tomography Coronary Angiography With Novel Quantitative Approach
Introduction: Computed tomography of the coronary arteries (CTCA) is an important diagnostic tool. However, motion degradation is sometimes a challenge to interpretation and quantification, particularly with elevated heart rates. Here, a novel quantitative method is presented as part of an evaluation of one particular motion correction algorithm. Methods: Computed tomography of the coronary arteries scans from 49 patients, with heart rates of >70 bpm, were identified with motion artifacts in multiple coronary segments. At these foci (196), an objective measure of motion degradation, defined here by cross-section eccentricity, was determined before and after image processing with second-generation GE SnapShot Freeze software (SSF-2.0). In addition, a subjective scoring was applied by an expert cardiothoracic radiologist both before and after processing. Results: An overall decrease in vessel eccentricity strongly correlated (P < 0.001) with processing of the images by motion-correction software. A concurrent overall increase in subjective vessel clarity correlated (P < 0.001) with application of the software as well. Conclusions: A novel quantitative method (and subjective analysis) for evaluation of CTCA motion has been described and applied to validation of SSF-2.0 motion-correction software. Both the technique and software demonstrate promise for robust clinical utility in CTCA evaluation.
- 13 April 2019
- Published by Springer Nature in Current Radiology Reports
- Vol. 7 (6) , 1-11
Emerging Role of Fluciclovine and Other Next Generation PET Imaging Agents in Prostate Cancer Management
- 13 April 2019
- Published by Springer Nature in Current Radiology Reports
- Vol. 7 (6) , 1-11
Emerging Role of Fluciclovine and Other Next Generation PET Imaging Agents in Prostate Cancer Management