Dongkyu Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dongkyu Lee has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Kang-Ho Lee
Daegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea
4 shared publications Ohwon Kwon
Department of Diagnostic Sensors, Korea Institute of Machinery and Materials (KIMM), Daegu, 42994, Republic of Korea
4 shared publications- Ohwon Kwon
Daegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea
4 shared publications Kang-Ho Lee
3 shared publications- Byungkyu Kim
Department of Mechanical and Aerospace Engineering Korea Aerospace University Goyang 10540 Republic of Korea
2 shared publications - Hyukjin Lee
Daegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea
2 shared publications
Latest Publications
- 2 December 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1385, 344980
Miniaturized volatile organic compound sensor platform for the real-time monitoring of bacterial growth and antibiotic susceptibility
- 2 December 2025
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1385, 344980
Miniaturized volatile organic compound sensor platform for the real-time monitoring of bacterial growth and antibiotic susceptibility
- Open Access
- 30 November 2022
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 31 (6) , 433-440
Smart Helmet for Vital Sign-Based Heatstroke Detection Using Support Vector Machine
- 30 November 2022
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 31 (6) , 433-440
Open AccessSmart Helmet for Vital Sign-Based Heatstroke Detection Using Support Vector Machine
- Open Access
A Prosthetic Socket with Active Volume Compensation for Amputated Lower Limb
Typically, the actual volume of the residual limb changes over time. This causes the prosthesis to not fit, and then pain and skin disease. In this study, a prosthetic socket was developed to compensate for the volume change of the residual limb. Using an inflatable air bladder, the proposed socket monitors the pressure in the socket and keeps the pressure distribution uniform and constant while walking. The socket has three air bladders on anterior and posterior tibia areas, a latching type 3-way pneumatic valve and a portable control device. In the paper, the mechanical properties of the air bladder were investigated, and the electromagnetic analysis was performed to design the pneumatic valve. The controller is based on a hysteresis control algorithm with a closed loop, which keeps the pressure in the socket close to the initial set point over a long period of time. In experiments, the proposed prosthesis was tested through the gait simulator that can imitate a human’s gait cycle. The active volume compensation of the socket was successfully verified during repetitive gait cycle using the weight loads of 50, 70, and 90 kg and the residual limb model with a variety of volumes. It was confirmed that the pressure of the residual limb recovered to the initial state through the active control. The pressure inside the socket had a steady state error of less than 0.75% even if the volume of the residual limb was changed from −7% to +7%.
Open AccessA Prosthetic Socket with Active Volume Compensation for Amputated Lower Limb
Typically, the actual volume of the residual limb changes over time. This causes the prosthesis to not fit, and then pain and skin disease. In this study, a prosthetic socket was developed to compensate for the volume change of the residual limb. Using an inflatable air bladder, the proposed socket monitors the pressure in the socket and keeps the pressure distribution uniform and constant while walking. The socket has three air bladders on anterior and posterior tibia areas, a latching type 3-way pneumatic valve and a portable control device. In the paper, the mechanical properties of the air bladder were investigated, and the electromagnetic analysis was performed to design the pneumatic valve. The controller is based on a hysteresis control algorithm with a closed loop, which keeps the pressure in the socket close to the initial set point over a long period of time. In experiments, the proposed prosthesis was tested through the gait simulator that can imitate a human’s gait cycle. The active volume compensation of the socket was successfully verified during repetitive gait cycle using the weight loads of 50, 70, and 90 kg and the residual limb model with a variety of volumes. It was confirmed that the pressure of the residual limb recovered to the initial state through the active control. The pressure inside the socket had a steady state error of less than 0.75% even if the volume of the residual limb was changed from −7% to +7%.
- Open Access
Integrated, Automated, Fast PCR System for Point-Of-Care Molecular Diagnosis of Bacterial Infection
We developed an integrated PCR system that performs automated sample preparation and fast polymerase chain reaction (PCR) for application in point-of care (POC) testing. This system is assembled from inexpensive 3D-printing parts, off-the-shelf electronics and motors. Molecular detection requires a series of procedures including sample preparation, amplification, and fluorescence intensity analysis. The system can perform automated DNA sample preparation (extraction, separation and purification) in ≤5 min. The variance of the automated sample preparation was clearly lower than that achieved using manual DNA extraction. Fast thermal ramp cycles were generated by a customized thermocycler designed to automatically transport samples between heating and cooling blocks. Despite the large sample volume (50 μL), rapid two-step PCR amplification completed 40 cycles in ≤13.8 min. Variations in fluorescence intensity were measured by analyzing fluorescence images. As proof of concept of this system, we demonstrated the rapid DNA detection of pathogenic bacteria. We also compared the sensitivity of this system with that of a commercial device during the automated extraction and fast PCR of Salmonella bacteria.
Open AccessIntegrated, Automated, Fast PCR System for Point-Of-Care Molecular Diagnosis of Bacterial Infection
We developed an integrated PCR system that performs automated sample preparation and fast polymerase chain reaction (PCR) for application in point-of care (POC) testing. This system is assembled from inexpensive 3D-printing parts, off-the-shelf electronics and motors. Molecular detection requires a series of procedures including sample preparation, amplification, and fluorescence intensity analysis. The system can perform automated DNA sample preparation (extraction, separation and purification) in ≤5 min. The variance of the automated sample preparation was clearly lower than that achieved using manual DNA extraction. Fast thermal ramp cycles were generated by a customized thermocycler designed to automatically transport samples between heating and cooling blocks. Despite the large sample volume (50 μL), rapid two-step PCR amplification completed 40 cycles in ≤13.8 min. Variations in fluorescence intensity were measured by analyzing fluorescence images. As proof of concept of this system, we demonstrated the rapid DNA detection of pathogenic bacteria. We also compared the sensitivity of this system with that of a commercial device during the automated extraction and fast PCR of Salmonella bacteria.
- Open Access
Active Body Pressure Relief System with Time-of-Flight Optical Pressure Sensors for Pressure Ulcer Prevention
A body pressure relief system was newly developed with optical pressure sensors for pressure ulcer prevention. Unlike a conventional alternating pressure air mattress (APAM), this system automatically regulates air flow into a body supporting mattress with adaptive inflation (or deflation) duration in response to the pressure level in order to reduce skin stress due to prolonged high pressures. The system continuously quantifies the body pressure distribution using time-of-flight (ToF) optical sensors. The proposed pressure sensor, a ToF optical sensor in the air-filled cell, measures changes in surface height of mattress when pressed under body weight, thereby indirectly indicating the interface pressure. Non-contact measurement of optical sensor usually improves the durability and repeatability of the system. The pressure sensor was successfully identified the 4 different-predefined postures, and quantitatively measured the body pressure distribution of them. Duty cycle of switches in solenoid valves was adjusted to 0–50% for pressure relief, which shows that the interface pressure was lower than 32 mmHg for pressure ulcer prevention.
Open AccessActive Body Pressure Relief System with Time-of-Flight Optical Pressure Sensors for Pressure Ulcer Prevention
A body pressure relief system was newly developed with optical pressure sensors for pressure ulcer prevention. Unlike a conventional alternating pressure air mattress (APAM), this system automatically regulates air flow into a body supporting mattress with adaptive inflation (or deflation) duration in response to the pressure level in order to reduce skin stress due to prolonged high pressures. The system continuously quantifies the body pressure distribution using time-of-flight (ToF) optical sensors. The proposed pressure sensor, a ToF optical sensor in the air-filled cell, measures changes in surface height of mattress when pressed under body weight, thereby indirectly indicating the interface pressure. Non-contact measurement of optical sensor usually improves the durability and repeatability of the system. The pressure sensor was successfully identified the 4 different-predefined postures, and quantitatively measured the body pressure distribution of them. Duty cycle of switches in solenoid valves was adjusted to 0–50% for pressure relief, which shows that the interface pressure was lower than 32 mmHg for pressure ulcer prevention.
- Open Access
A Sensitive Potentiometric Sensor for Isothermal Amplification-Coupled Detection of Nucleic Acids
A disposable potentiometric sensor was newly developed for the amplification-coupled detection of nucleic acids. The hydrogen-ion is generally released during isothermal amplification of nucleic acids. The surface potential on the oxide-functionalized electrode of the extended gate was directly measured using full electrical circuits with the commercial metal-oxide semiconductor field-effect transistors (MOSFETs) and ring oscillator components, which resulted in cost-effective, portable and scalable real-time nucleic acid analysis. The current-starved ring oscillator changes surface potential to its frequency depending on the square of the variation in pH with a high signal-to-noise ratio during isothermal amplification. The device achieves a conversion rate of 20.5 kHz/mV and a detection resolution of 200 µV for the surface potential. It is demonstrated that the sensor successfully monitors in real-time isothermal amplification of the extracted nucleic acids from Salmonella pathogenic bacteria. The in situ variations in the frequency of the pH-sensitive sensor were compared with the results of both a conventional optical device and pH-meter during isothermal amplification.
Open AccessA Sensitive Potentiometric Sensor for Isothermal Amplification-Coupled Detection of Nucleic Acids
A disposable potentiometric sensor was newly developed for the amplification-coupled detection of nucleic acids. The hydrogen-ion is generally released during isothermal amplification of nucleic acids. The surface potential on the oxide-functionalized electrode of the extended gate was directly measured using full electrical circuits with the commercial metal-oxide semiconductor field-effect transistors (MOSFETs) and ring oscillator components, which resulted in cost-effective, portable and scalable real-time nucleic acid analysis. The current-starved ring oscillator changes surface potential to its frequency depending on the square of the variation in pH with a high signal-to-noise ratio during isothermal amplification. The device achieves a conversion rate of 20.5 kHz/mV and a detection resolution of 200 µV for the surface potential. It is demonstrated that the sensor successfully monitors in real-time isothermal amplification of the extracted nucleic acids from Salmonella pathogenic bacteria. The in situ variations in the frequency of the pH-sensitive sensor were compared with the results of both a conventional optical device and pH-meter during isothermal amplification.
- 9 March 2017
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 18 (3) , 461-465
Input signal effects on the locomotion of a robotic colonoscope activated by a flexible shaft
- 9 March 2017
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 18 (3) , 461-465
Input signal effects on the locomotion of a robotic colonoscope activated by a flexible shaft
- 2 January 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 110 (1)
Plasmonic absorbers with optical cavity for the enhancement of photothermal/opto-calorimetric infrared spectroscopy
Plasmonic absorbers with optical cavity are fabricated using deposition of thin gold films on both sides of nanoporous anodic aluminum oxide (AAO) microcantilevers. Photothermal/opto-calorimetric responses of the microcantilevers are investigated with respect to various pore sizes and gold coating thicknesses. Photothermal/opto-calorimetric response of the AAO cantilever is significantly amplified when the thickness of the gold layer is at 40 nm due to scattering and trapping of infrared (IR) radiation in the gold nanomesh/AAO nanochannels/gold layer structure. Unlike previous photothermal IR spectroscopy of adsorbed molecules with a bimetallic AAO cantilever, the reversed IR spectra are obtained due to significantly amplified baseline photothermal signal and IR absorption of free molecules. Molecular detection sensitivity is enhanced by an order of magnitude compared with the previous photothermal IR spectroscopy of adsorbed molecules on a bimetallic AAO cantilever. The acetone vapor molecules are selectively recognized using the reversed IR spectra.
- 2 January 2017
- Published by AIP Publishing in Applied Physics Letters
- Vol. 110 (1)
Plasmonic absorbers with optical cavity for the enhancement of photothermal/opto-calorimetric infrared spectroscopy
Plasmonic absorbers with optical cavity are fabricated using deposition of thin gold films on both sides of nanoporous anodic aluminum oxide (AAO) microcantilevers. Photothermal/opto-calorimetric responses of the microcantilevers are investigated with respect to various pore sizes and gold coating thicknesses. Photothermal/opto-calorimetric response of the AAO cantilever is significantly amplified when the thickness of the gold layer is at 40 nm due to scattering and trapping of infrared (IR) radiation in the gold nanomesh/AAO nanochannels/gold layer structure. Unlike previous photothermal IR spectroscopy of adsorbed molecules with a bimetallic AAO cantilever, the reversed IR spectra are obtained due to significantly amplified baseline photothermal signal and IR absorption of free molecules. Molecular detection sensitivity is enhanced by an order of magnitude compared with the previous photothermal IR spectroscopy of adsorbed molecules on a bimetallic AAO cantilever. The acetone vapor molecules are selectively recognized using the reversed IR spectra.
- 12 May 2016
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 17 (5) , 597-601
Fully automated molecular diagnosis by a novel cartridge-based platform
- 12 May 2016
- Published by Springer Nature in International Journal of Precision Engineering and Manufacturing
- Vol. 17 (5) , 597-601
Fully automated molecular diagnosis by a novel cartridge-based platform
- 1 November 2014
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 28 (11) , 4673-4679
Numerical simulation and channel configuration design for a negative dielectrophoresis based high efficiency cell sorting platform
- 1 November 2014
- Published by Springer Nature in Journal of Mechanical Science and Technology
- Vol. 28 (11) , 4673-4679
Numerical simulation and channel configuration design for a negative dielectrophoresis based high efficiency cell sorting platform