Kang-Ho Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Kang-Ho Lee has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Dongkyu Lee
Daegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea
4 shared publications - Ohwon Kwon
Daegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea
4 shared publications Dongkyu Lee
2 shared publications- Hyukjin Lee
Daegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea
2 shared publications - JaeJong Lee
Korea Institute of Machinery and Materials (KIMM), 156 Gajeongbuk-ro, Yuseong-gu, Daejeon 34103, Republic of Korea
2 shared publications - Jongsu Yoon
Daegu Research Center for Medical Devices, Korea institute of Machinery and Materials, Daegu 42994, Korea
2 shared publications
Latest Publications
- Open Access
A Pneumatically Controlled Prosthetic Socket for Transfemoral Amputees
Amputees typically experience changes in residual limb volume in their daily lives. It causes an uncomfortable fit of the socket by applying high pressure on the sensitive area of the residual limb or by loosening the socket. In this study, we developed a transfemoral prosthetic socket for above-the-knee amputees that ensures a good socket fit by maintaining uniform and constant contact pressure despite volume changes in the residual limb. The socket has two air bladders in the posterior femoral region, and the pneumatic controller is located on the tibia of the prosthesis. The pneumatic system aims to minimize unstable fitting of the socket and improve walking performance by inflating or deflating the air bladder. The developed socket autonomously maintains the air pressure inside the prosthetic socket at a steady-state error of 3 mmHg or less by adjusting the amount of air in the air bladder via closed-loop control. In the clinical trial, amputee participants walked on flat and inclined surfaces. The displacement between the residual limb and socket during the gait cycle was reduced by up to 33.4% after air injection into the socket. The inflatable bladder increased the knee flexion angle on the affected side, resulting in increased stride length and gait velocity. The pneumatic socket provides a stable and comfortable walking experience not only when walking on flat ground but also on slopes.
Open AccessA Pneumatically Controlled Prosthetic Socket for Transfemoral Amputees
Amputees typically experience changes in residual limb volume in their daily lives. It causes an uncomfortable fit of the socket by applying high pressure on the sensitive area of the residual limb or by loosening the socket. In this study, we developed a transfemoral prosthetic socket for above-the-knee amputees that ensures a good socket fit by maintaining uniform and constant contact pressure despite volume changes in the residual limb. The socket has two air bladders in the posterior femoral region, and the pneumatic controller is located on the tibia of the prosthesis. The pneumatic system aims to minimize unstable fitting of the socket and improve walking performance by inflating or deflating the air bladder. The developed socket autonomously maintains the air pressure inside the prosthetic socket at a steady-state error of 3 mmHg or less by adjusting the amount of air in the air bladder via closed-loop control. In the clinical trial, amputee participants walked on flat and inclined surfaces. The displacement between the residual limb and socket during the gait cycle was reduced by up to 33.4% after air injection into the socket. The inflatable bladder increased the knee flexion angle on the affected side, resulting in increased stride length and gait velocity. The pneumatic socket provides a stable and comfortable walking experience not only when walking on flat ground but also on slopes.
- Open Access
- 31 March 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (2) , 67-70
Sewing-enabled electric button for smart fabric
- 31 March 2021
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 30 (2) , 67-70
Open AccessSewing-enabled electric button for smart fabric
- Open Access
A Prosthetic Socket with Active Volume Compensation for Amputated Lower Limb
Typically, the actual volume of the residual limb changes over time. This causes the prosthesis to not fit, and then pain and skin disease. In this study, a prosthetic socket was developed to compensate for the volume change of the residual limb. Using an inflatable air bladder, the proposed socket monitors the pressure in the socket and keeps the pressure distribution uniform and constant while walking. The socket has three air bladders on anterior and posterior tibia areas, a latching type 3-way pneumatic valve and a portable control device. In the paper, the mechanical properties of the air bladder were investigated, and the electromagnetic analysis was performed to design the pneumatic valve. The controller is based on a hysteresis control algorithm with a closed loop, which keeps the pressure in the socket close to the initial set point over a long period of time. In experiments, the proposed prosthesis was tested through the gait simulator that can imitate a human’s gait cycle. The active volume compensation of the socket was successfully verified during repetitive gait cycle using the weight loads of 50, 70, and 90 kg and the residual limb model with a variety of volumes. It was confirmed that the pressure of the residual limb recovered to the initial state through the active control. The pressure inside the socket had a steady state error of less than 0.75% even if the volume of the residual limb was changed from −7% to +7%.
Open AccessA Prosthetic Socket with Active Volume Compensation for Amputated Lower Limb
Typically, the actual volume of the residual limb changes over time. This causes the prosthesis to not fit, and then pain and skin disease. In this study, a prosthetic socket was developed to compensate for the volume change of the residual limb. Using an inflatable air bladder, the proposed socket monitors the pressure in the socket and keeps the pressure distribution uniform and constant while walking. The socket has three air bladders on anterior and posterior tibia areas, a latching type 3-way pneumatic valve and a portable control device. In the paper, the mechanical properties of the air bladder were investigated, and the electromagnetic analysis was performed to design the pneumatic valve. The controller is based on a hysteresis control algorithm with a closed loop, which keeps the pressure in the socket close to the initial set point over a long period of time. In experiments, the proposed prosthesis was tested through the gait simulator that can imitate a human’s gait cycle. The active volume compensation of the socket was successfully verified during repetitive gait cycle using the weight loads of 50, 70, and 90 kg and the residual limb model with a variety of volumes. It was confirmed that the pressure of the residual limb recovered to the initial state through the active control. The pressure inside the socket had a steady state error of less than 0.75% even if the volume of the residual limb was changed from −7% to +7%.
- Open Access
Integrated, Automated, Fast PCR System for Point-Of-Care Molecular Diagnosis of Bacterial Infection
We developed an integrated PCR system that performs automated sample preparation and fast polymerase chain reaction (PCR) for application in point-of care (POC) testing. This system is assembled from inexpensive 3D-printing parts, off-the-shelf electronics and motors. Molecular detection requires a series of procedures including sample preparation, amplification, and fluorescence intensity analysis. The system can perform automated DNA sample preparation (extraction, separation and purification) in ≤5 min. The variance of the automated sample preparation was clearly lower than that achieved using manual DNA extraction. Fast thermal ramp cycles were generated by a customized thermocycler designed to automatically transport samples between heating and cooling blocks. Despite the large sample volume (50 μL), rapid two-step PCR amplification completed 40 cycles in ≤13.8 min. Variations in fluorescence intensity were measured by analyzing fluorescence images. As proof of concept of this system, we demonstrated the rapid DNA detection of pathogenic bacteria. We also compared the sensitivity of this system with that of a commercial device during the automated extraction and fast PCR of Salmonella bacteria.
Open AccessIntegrated, Automated, Fast PCR System for Point-Of-Care Molecular Diagnosis of Bacterial Infection
We developed an integrated PCR system that performs automated sample preparation and fast polymerase chain reaction (PCR) for application in point-of care (POC) testing. This system is assembled from inexpensive 3D-printing parts, off-the-shelf electronics and motors. Molecular detection requires a series of procedures including sample preparation, amplification, and fluorescence intensity analysis. The system can perform automated DNA sample preparation (extraction, separation and purification) in ≤5 min. The variance of the automated sample preparation was clearly lower than that achieved using manual DNA extraction. Fast thermal ramp cycles were generated by a customized thermocycler designed to automatically transport samples between heating and cooling blocks. Despite the large sample volume (50 μL), rapid two-step PCR amplification completed 40 cycles in ≤13.8 min. Variations in fluorescence intensity were measured by analyzing fluorescence images. As proof of concept of this system, we demonstrated the rapid DNA detection of pathogenic bacteria. We also compared the sensitivity of this system with that of a commercial device during the automated extraction and fast PCR of Salmonella bacteria.
- Open Access
- 30 September 2020
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 29 (5) , 279-282
Quantitative Monitoring of Body Pressure Distribution Using Built-in Optical Sensors
- 30 September 2020
- Published by The Korean Sensors Society in Journal of Sensor Science and Technology
- Vol. 29 (5) , 279-282
Open AccessQuantitative Monitoring of Body Pressure Distribution Using Built-in Optical Sensors
- Open Access
- 4 March 2020
- Published by MDPI AG in Electronics
- Vol. 9 (3) , 431
Inductive Power Transmission for Wearable Textile Heater using Series-None Topology
In this paper, an inductive-power-transmission (IPT) system for a wearable textile heater is proposed to comfortably provide heating to a user’s body. The conductive thread, which has high electrical resistance, was sewn into a receiver (Rx) coil on clothing to generate high temperature with a low current. The proposed wearable heaters are completely washable thanks to their nonmetallic materials, other than conductive threads in the clothing. We introduced series-none (SN) topology to eliminate a resonant capacitor in the wearable textile heater. A single resonant capacitor in a transmitter (Tx) in SN mode was implemented to resonate both Tx and Rx, resulting in increased power delivered to the load (PDL) while maintaining high-power transfer efficiency (PTE), comparable with conventional series-series (SS) topology. When the supply voltage of the power amplifier was 7 V, while the PTE of the SS and SN modes was 85.2% and 75.8%, respectively, the PDL of the SS and SN modes was 2.74 and 4.6 W, respectively.
- 4 March 2020
- Published by MDPI AG in Electronics
- Vol. 9 (3) , 431
Open AccessInductive Power Transmission for Wearable Textile Heater using Series-None Topology
In this paper, an inductive-power-transmission (IPT) system for a wearable textile heater is proposed to comfortably provide heating to a user’s body. The conductive thread, which has high electrical resistance, was sewn into a receiver (Rx) coil on clothing to generate high temperature with a low current. The proposed wearable heaters are completely washable thanks to their nonmetallic materials, other than conductive threads in the clothing. We introduced series-none (SN) topology to eliminate a resonant capacitor in the wearable textile heater. A single resonant capacitor in a transmitter (Tx) in SN mode was implemented to resonate both Tx and Rx, resulting in increased power delivered to the load (PDL) while maintaining high-power transfer efficiency (PTE), comparable with conventional series-series (SS) topology. When the supply voltage of the power amplifier was 7 V, while the PTE of the SS and SN modes was 85.2% and 75.8%, respectively, the PDL of the SS and SN modes was 2.74 and 4.6 W, respectively.
- Open Access
Active Body Pressure Relief System with Time-of-Flight Optical Pressure Sensors for Pressure Ulcer Prevention
A body pressure relief system was newly developed with optical pressure sensors for pressure ulcer prevention. Unlike a conventional alternating pressure air mattress (APAM), this system automatically regulates air flow into a body supporting mattress with adaptive inflation (or deflation) duration in response to the pressure level in order to reduce skin stress due to prolonged high pressures. The system continuously quantifies the body pressure distribution using time-of-flight (ToF) optical sensors. The proposed pressure sensor, a ToF optical sensor in the air-filled cell, measures changes in surface height of mattress when pressed under body weight, thereby indirectly indicating the interface pressure. Non-contact measurement of optical sensor usually improves the durability and repeatability of the system. The pressure sensor was successfully identified the 4 different-predefined postures, and quantitatively measured the body pressure distribution of them. Duty cycle of switches in solenoid valves was adjusted to 0–50% for pressure relief, which shows that the interface pressure was lower than 32 mmHg for pressure ulcer prevention.
Open AccessActive Body Pressure Relief System with Time-of-Flight Optical Pressure Sensors for Pressure Ulcer Prevention
A body pressure relief system was newly developed with optical pressure sensors for pressure ulcer prevention. Unlike a conventional alternating pressure air mattress (APAM), this system automatically regulates air flow into a body supporting mattress with adaptive inflation (or deflation) duration in response to the pressure level in order to reduce skin stress due to prolonged high pressures. The system continuously quantifies the body pressure distribution using time-of-flight (ToF) optical sensors. The proposed pressure sensor, a ToF optical sensor in the air-filled cell, measures changes in surface height of mattress when pressed under body weight, thereby indirectly indicating the interface pressure. Non-contact measurement of optical sensor usually improves the durability and repeatability of the system. The pressure sensor was successfully identified the 4 different-predefined postures, and quantitatively measured the body pressure distribution of them. Duty cycle of switches in solenoid valves was adjusted to 0–50% for pressure relief, which shows that the interface pressure was lower than 32 mmHg for pressure ulcer prevention.
- Open Access
A Sensitive Potentiometric Sensor for Isothermal Amplification-Coupled Detection of Nucleic Acids
A disposable potentiometric sensor was newly developed for the amplification-coupled detection of nucleic acids. The hydrogen-ion is generally released during isothermal amplification of nucleic acids. The surface potential on the oxide-functionalized electrode of the extended gate was directly measured using full electrical circuits with the commercial metal-oxide semiconductor field-effect transistors (MOSFETs) and ring oscillator components, which resulted in cost-effective, portable and scalable real-time nucleic acid analysis. The current-starved ring oscillator changes surface potential to its frequency depending on the square of the variation in pH with a high signal-to-noise ratio during isothermal amplification. The device achieves a conversion rate of 20.5 kHz/mV and a detection resolution of 200 µV for the surface potential. It is demonstrated that the sensor successfully monitors in real-time isothermal amplification of the extracted nucleic acids from Salmonella pathogenic bacteria. The in situ variations in the frequency of the pH-sensitive sensor were compared with the results of both a conventional optical device and pH-meter during isothermal amplification.
Open AccessA Sensitive Potentiometric Sensor for Isothermal Amplification-Coupled Detection of Nucleic Acids
A disposable potentiometric sensor was newly developed for the amplification-coupled detection of nucleic acids. The hydrogen-ion is generally released during isothermal amplification of nucleic acids. The surface potential on the oxide-functionalized electrode of the extended gate was directly measured using full electrical circuits with the commercial metal-oxide semiconductor field-effect transistors (MOSFETs) and ring oscillator components, which resulted in cost-effective, portable and scalable real-time nucleic acid analysis. The current-starved ring oscillator changes surface potential to its frequency depending on the square of the variation in pH with a high signal-to-noise ratio during isothermal amplification. The device achieves a conversion rate of 20.5 kHz/mV and a detection resolution of 200 µV for the surface potential. It is demonstrated that the sensor successfully monitors in real-time isothermal amplification of the extracted nucleic acids from Salmonella pathogenic bacteria. The in situ variations in the frequency of the pH-sensitive sensor were compared with the results of both a conventional optical device and pH-meter during isothermal amplification.
- Open Access
- 1 February 2017
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 53 (4) , 251-253
Differential pH‐sensitive sensor with DC electrode‐offset compensation
A pH‐sensitive sensor with a differential mode was developed to detect surface charges accumulated on the ion‐sensitive layer. The device accurately monitors the relative pH value using the modified instrumentation amplifier with the DC electrode‐offset compensation. The readout voltage is digitalised with the current‐starved ring oscillator. The sensor achieves the DC offset compensation of 22.5 dB and the oscillating pH sensitivity of 1.3 MHz/pH. The feasibility of the sensor is demonstrated to monitor the hydrogen ion concentration comparing the oscillation frequency at differential mode with that at single mode.
- 1 February 2017
- Published by Institution of Engineering and Technology (IET) in Electronics Letters
- Vol. 53 (4) , 251-253
Open AccessDifferential pH‐sensitive sensor with DC electrode‐offset compensation
A pH‐sensitive sensor with a differential mode was developed to detect surface charges accumulated on the ion‐sensitive layer. The device accurately monitors the relative pH value using the modified instrumentation amplifier with the DC electrode‐offset compensation. The readout voltage is digitalised with the current‐starved ring oscillator. The sensor achieves the DC offset compensation of 22.5 dB and the oscillating pH sensitivity of 1.3 MHz/pH. The feasibility of the sensor is demonstrated to monitor the hydrogen ion concentration comparing the oscillation frequency at differential mode with that at single mode.