RMRobert Moss

Robert Moss

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Robert Moss has a total of 41 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Tomographic quality evaluation of flexible x-ray scintillating imaging skins

    by Rozenn Raffaut, Robert Moss, Agostino Stilli, Danail Stoyanov

    Objective. Detecting abnormal tissue in minimally invasive surgery is challenging due to the lack of direct palpation for the surgeon, with visualisation often being limited to white light endoscope images of the tissue surface, providing no information about inner structures. Imaging skins are being explored as a novel method of surgical image guidance: they are flexible and stretchable scintillating films that can act as indirect x-ray detectors when placed directly on the organ surface. Approach. Tomographic imaging of a custom quality evaluation phantom was performed using the imaging skin system. Image quality metrics, including spatial resolution, contrast, and uniformity, were obtained and compared to a conventional flat-panel micro-CT system. Main results. The imaging skin scan achieved a spatial resolution of 3.11 lp mm − 1 at 10% contrast. While these results were worse than that of the micro-CT system, the imaging skin system still met the requirements for clinical CT, demonstrating its clinical suitability. Significance. The feasibility of 3D x-ray imaging using imaging skins directly placed onto the imaged object has been demonstrated, achieving high resolution, comparable to clinical CT. Future work will involve artefact corrections and more advanced reconstruction techniques for the intended application of imaging skins for real-time surgical guidance.

  • Open Access

    Imaging skins: stretchable Gd2O2S:Tb X-ray detectors for image-guided surgery

    by Rozenn Raffaut, Robert Moss, Agostino Stilli, Danail Stoyanov

    Purpose:: With the growing demands for diverse X-ray imaging applications, there is a need for the development of flexible X-ray detectors to enable conformity to curved surfaces, improving spatial resolution, reducing X-ray exposure, and extending the potential of X-ray imaging to fields such as minimally invasive surgery, which would not be achievable using conventional rigid flat-panel detectors. Methods:: In this paper, we fabricate imaging skins—flexible and stretchable Gd2O2S:Tb-elastomer scintillator films—and integrate them into an indirect X-ray imaging system. We characterise X-ray imaging performance and mechanical properties of the imaging skins, investigating the impact of varying film fabrication parameters such as thickness and concentration. Results:: The results demonstrate the clinical suitability of the imaging skin system, achieving 1.05 to 2.18 lp/mm at 10% contrast despite the low X-ray energy used, which is comparable to clinical CT. Additionally, the high stretchability (255%) from the elastomer component was maintained in imaging skins with up to 50% Gd2O2S:Tb loading. Conclusion:: This work provides a basis for the integration of imaging skins in clinical settings, where they have the potential to be used for real-time intraoperative image guidance. Future work will investigate dynamic and tomographic imaging methods, determine effective deployment strategies of the imaging skins onto organ surfaces, and investigate the effects of imaging skin deformation on image quality.

  • Open Access

    Perovskite Quantum Dots: A New Generation of Promising Scintillator Materials

    by Daihao Li, Tianming Sun, Stephen Kearney, Robert Moss, Mingqing Wang

    Scintillator materials are essential parts of X-ray imaging/detection for medical diagnostics, non-destructive detection, security inspection, and space exploration. Traditional commercial scintillators are limited by low luminescence efficiency and afterglow effect. Perovskite (ABX3) quantum dots (PQDs), with the ability to convert X-ray radiation into multi-color visible light, has emerged as a new class of competitive scintillators, based on the advantages of high X-ray absorption coefficients, fast luminescence, high luminescence efficiency, and low-cost wet chemical facile synthesis on various substrates. Understanding the relationship between the structure and luminescence of PQDs is essential for scintillator discovery and optimization. This chapter first reviewed the work principle, materials selection, and key parameters of indirect X-ray detectors, followed by the basic crystal structure, optoelectronic properties, and synthesis methods for PQDs. Then the recent advances in perovskite scintillators are comprehensively reviewed. Finally, we summarize the current challenge in perovskite scintillators with promising solutions and provide a perspective on the future direction of this emerging scintillator.


  • Open Access

    First Study of a HEXITEC Detector for Secondary Particle Characterisation during Proton Beam Therapy

    by Maria L. Perez-Lara, Jia C. Khong, Matthew D. Wilson, Ben D. Cline, Robert M. Moss

    Online proton range verification is a rapidly emerging field characterised by its ability to reduce the error margins during proton beam therapy, as it is patient-specific and in vivo. In particular, secondary prompt gamma detection is a promising tool to monitor the dose delivery. The present research evaluates the capability of a HEXITEC detector to identify the prompt gammas produced during proton beam therapy, and assesses its potential for online range verification. To achieve this, the detector is placed at one side of a water phantom, which is irradiated at different proton energies in the University College London Hospital Proton Centre. For further analysis, Monte Carlo simulations are performed using Geant4 and the same geometry as the experiment. The results show that HEXITEC has the potential to be part of a detection system that could identify secondary prompt gammas within the secondary field produced inside the target, allowing for the in-detector discrimination of these particles via cluster size analysis. The comparison between data sets shows that there is a high level of accuracy between the model and the experimental measurements in terms of secondary flux and charge diffusion inside the detector, which poses the model as a fundamental tool for future optimisation studies.


  • Open Access

    Polycrystalline Formamidinium Lead Bromide X-ray Detectors

    by Suad Alghamdi, Stephanie Bennett, Carol Crean, Joydip Ghosh, Harry Gibbard, Robert Moss, Justin Reiss, Douglas Wolfe, Paul Sellin

    We have investigated the performance of formamidinium lead bromide (FAPbBr3) perovskite X-ray detectors fabricated from polycrystalline material that is pressed into a pellet at high pressures. FAPbBr3 has been shown to exhibit a remarkable combination of electrical and physical properties, such that mechanically-formed polycrystalline pellets exhibit good charge transport properties suitable for use as X-ray detectors. We characterise the morphology and structure of FAPbBr3 pellets using photoluminescence (PL), electron microscopy (SEM) and X-ray diffraction (XRD), and demonstrate an improvement in the microstructure, density, and charge transport performance of the material as the pressure is increased from 12 MPa to 124 MPa. The use of annealing of the pellets after pressing also improves the stability and charge transport performance of the devices. Using a 40 kV X-ray beam, a maximum X-ray sensitivity of 169 µC Gy−1 cm−2 was measured, and the fast time response of the devices was demonstrated using a chopped X-ray beam.


  • Open Access

    A multi-method assessment of 3D printed micromorphological osteological features

    by Rachael M. Carew, Francesco Iacoviello, Carolyn Rando, Robert M. Moss, Robert Speller, James French, Ruth M. Morgan

    The evaluation of 3D printed osteological materials has highlighted the difficulties associated with accurately representing fine surface details on printed bones. Moreover, there is an increasing need for reconstructions to be demonstrably accurate and reliable for use in the criminal justice system. The aim of this study was to assess the surface quality of 3D prints (n = 9) that presented with micromorphological alterations from trauma, taphonomy and pathology processes. The archaeological bones were imaged using micro-CT scanning and 3D printed with selective laser sintering (SLS) printing. A multi-method experimental approach subsequently identified: (1) the 3D printed bones to be metrically accurate to within 1.0 mm; (2) good representation of micromorphological surface features overall, albeit with some loss of intricate details, depths, and fine textures that can be important for visual processing; (3) five of the nine 3D printed bones were quantitatively scored as accurate using the visual comparison method; and, (4) low mesh comparison distances (± 0.2 mm) between the original models and the digitised 3D print models. The findings offer empirical data that can be used to underpin 3D printed reconstructions of exhibits for use in courts of law. In addition, an adaptable pathway was presented that can be used to assess 3D print accuracy in future reconstructions.


  • Use of Photon Scattering Interactions in Diagnosis and Treatment of Disease

    by Robert Moss, Andrea Gutierrez, Amany Amin, Chiaki Crews, Robert Speller, Francesco Iacoviello, Paul Shearing, Sarah Vinnicombe, Selina Kolokytha

  • Open Access

    Correlation of X-ray diffraction signatures of breast tissue and their histopathological classification

    by Robert M. Moss, Amany S. Amin, Chiaki Crews, Colin A. Purdie, Lee B. Jordan, Francesco Iacoviello, Andrew Evans, Robert D. Speller, Sarah J. Vinnicombe

    This pilot study examines the correlation of X-ray diffraction (XRD) measurements with the histopathological analysis of breast tissue. Eight breast cancer samples were investigated. Each sample contained a mixture of normal and cancerous tissues. In total, 522 separate XRD measurements were made at different locations across the samples (8 in total). The resulting XRD spectra were subjected to principal component analysis (PCA) in order to determine if there were any distinguishing features that could be used to identify different tissue components. 99.0% of the variation between the spectra were described by the first two principal components (PC). Comparing the location of points in PC space with the classification determined by histopathology indicated correlation between the shape/magnitude of the XRD spectra and the tissue type. These results are encouraging and suggest that XRD could be used for the intraoperative or postoperative classification of bulk tissue samples.


  • Open Access

    miniPixD: a compact sample analysis system which combines X-ray imaging and diffraction

    by Robert Moss, Chiaki Crews, Matthew Wilson, Robert Speller

    This paper introduces miniPixD: a new, compact system that utilises transmission X-ray imaging and X-ray diffraction (XRD) to locate and identify materials of interest within an otherwise opaque volume. The system and the embodied techniques have utility in security screening, medical diagnostics, non-destructive testing (NDT) and quality assurance (QA). This paper outlines the design of the system including discussion on the choice of components and presents some data from relevant samples which are compared to other energy dispersive and angular dispersive XRD techniques.


  • Open Access

    NXFit: a program for simultaneously fitting X-ray and neutron diffraction pair-distribution functions to provide optimized structural parameters

    by David Pickup, Robert Moss, Robert Newport

    NXFitis a program for obtaining optimized structural parameters from amorphous materials by simultaneously fitting X-ray and neutron pair-distribution functions. Partial correlation functions are generated inQspace, summed and Fourier transformed for comparison with the experimental data inrspace.NXFituses the Nelder–Mead method to vary a set of `best guess' parameters to achieve a fit to experimentally derived data. The output parameters fromNXFitare coordination number, atomic separation and disorder parameter for each atomic correlation used in the fitting process. The use ofNXFithas been demonstrated by fitting both X-ray and neutron diffraction data from two quite different amorphous materials: a melt-quenched (Na2O)0.5(P2O5)0.5glass and a (TiO2)0.18(SiO2)0.82sol–gel.