Samia Ahmed Abdelrahman Aly
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Samia Ahmed Abdelrahman Aly has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Mai Fayed
Sanitary Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, Egypt
2 shared publicationsPeter M. Huck
Department of Civil & Environmental Engineering, University of Waterloo, Waterloo, ON N2 L 3G1, Canada
2 shared publications- Alaa M. Metwally1 shared publication
- Amr Mohamed Sayed-Ahmed Abdelkader
Sanitary Eng. Dept., Faculty of Eng., Alexandria University, Alexandria, Egypt
1 shared publication Medhat Moustafa
1 shared publicationMennat-Allah A. M. Neama
Sanitary Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, Egypt
1 shared publication
Latest Publications
- Open Access
- 26 December 2025
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 134, 610-620
Performance enhancement and hydraulic optimization of water treatment processes: A case study of Kafr El-Sheikh Water Purification Plant, Egypt
- 26 December 2025
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 134, 610-620
Open AccessPerformance enhancement and hydraulic optimization of water treatment processes: A case study of Kafr El-Sheikh Water Purification Plant, Egypt
- Open Access
- 11 September 2025
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 130, 115-138
Biosorption of methylene blue from industrial wastewater using silicon dioxide nanoparticles and Cladophora glomerata
- 11 September 2025
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 130, 115-138
Open AccessBiosorption of methylene blue from industrial wastewater using silicon dioxide nanoparticles and Cladophora glomerata
- Open Access
- 25 November 2024
- Published by IWA Publishing in Water Practice & Technology
- Vol. 19 (12) , 4754-4772
Upgrading the eastern wastewater treatment plant effluent quality in Egypt for reuse by means of in-line coagulation followed by ultrafiltration
Providing clean water to Egyptian citizens is one target of the 2030 sustainable development goals. Ultrafiltration (UF) has been investigated as an advanced treatment of the largest treatment plant in Alexandria. Although UF membranes have been widely used to treat secondary effluent, fouling remains a major challenge. The effects of green and conventional coagulants on controlling ultrafiltration fouling were examined. Two different dosages of each coagulant and a combination of ferric chloride and sodium ferrate were studied in a bench-scale setup that was built and operated under identical circumstances. The results showed that the combined ferrate and ferric chloride pretreatment had the highest performance in terms of the removal of organics and turbidity as well as the reduction of membrane fouling. Fouling can be managed in terms of the normalized flux drop with only 0.5 mg/L of ferrate, which performs similarly to 2.5 mg/L of ferric chloride. The higher the dosage of alum used, the lesser the fouling control observed. The green coagulant, when used as an in-line coagulant aid/oxidant with ferric chloride at very low doses, has a favorable potential to reduce membrane fouling and improve permeated wastewater quality, making it suitable for Grade A for reuse purposes.
- 25 November 2024
- Published by IWA Publishing in Water Practice & Technology
- Vol. 19 (12) , 4754-4772
Open AccessUpgrading the eastern wastewater treatment plant effluent quality in Egypt for reuse by means of in-line coagulation followed by ultrafiltration
Providing clean water to Egyptian citizens is one target of the 2030 sustainable development goals. Ultrafiltration (UF) has been investigated as an advanced treatment of the largest treatment plant in Alexandria. Although UF membranes have been widely used to treat secondary effluent, fouling remains a major challenge. The effects of green and conventional coagulants on controlling ultrafiltration fouling were examined. Two different dosages of each coagulant and a combination of ferric chloride and sodium ferrate were studied in a bench-scale setup that was built and operated under identical circumstances. The results showed that the combined ferrate and ferric chloride pretreatment had the highest performance in terms of the removal of organics and turbidity as well as the reduction of membrane fouling. Fouling can be managed in terms of the normalized flux drop with only 0.5 mg/L of ferrate, which performs similarly to 2.5 mg/L of ferric chloride. The higher the dosage of alum used, the lesser the fouling control observed. The green coagulant, when used as an in-line coagulant aid/oxidant with ferric chloride at very low doses, has a favorable potential to reduce membrane fouling and improve permeated wastewater quality, making it suitable for Grade A for reuse purposes.
- Open Access
- 25 June 2024
- Published by IWA Publishing in Water Science & Technology
- Vol. 90 (1) , 61-74
Ferrate as a coagulant prior to sand filters treating secondary wastewater effluent for reuse
Wastewater reuse is one of the crucial water resources in Egypt due to the ongoing need to increase water resources and close the supply-demand gap. In this study, a new coagulant has been investigated before sand filters as an advanced wastewater treatment method. The sand filter pilot was run at a hydraulic loading rate of 0.75 m/h and two different dosages of three coagulants (Alum, FeCl3, and Ferrate VI) were selected using the jar tests. The sand filter without coagulant removed 12% of BOD5 and 70% of turbidity. Applying in-line coagulation before the sand filter provided effluents with better quality, especially for turbidity, organics, and microorganisms. Ferrate provided the highest removal of turbidity (90%) and BOD5 (93%) at very low dosages and lower costs compared with other coagulants, however, it adversely impacted both conductivity and dissolved solids. A significant effect on reducing bacteria was obtained with 40.0 mg/L of alum. According to the study's findings, the ferrate coagulant enhanced the sand filter's performance producing effluents with high quality, enabling it to meet strict water reuse regulations as well as aquatic environmental and health preservations.
- 25 June 2024
- Published by IWA Publishing in Water Science & Technology
- Vol. 90 (1) , 61-74
Open AccessFerrate as a coagulant prior to sand filters treating secondary wastewater effluent for reuse
Wastewater reuse is one of the crucial water resources in Egypt due to the ongoing need to increase water resources and close the supply-demand gap. In this study, a new coagulant has been investigated before sand filters as an advanced wastewater treatment method. The sand filter pilot was run at a hydraulic loading rate of 0.75 m/h and two different dosages of three coagulants (Alum, FeCl3, and Ferrate VI) were selected using the jar tests. The sand filter without coagulant removed 12% of BOD5 and 70% of turbidity. Applying in-line coagulation before the sand filter provided effluents with better quality, especially for turbidity, organics, and microorganisms. Ferrate provided the highest removal of turbidity (90%) and BOD5 (93%) at very low dosages and lower costs compared with other coagulants, however, it adversely impacted both conductivity and dissolved solids. A significant effect on reducing bacteria was obtained with 40.0 mg/L of alum. According to the study's findings, the ferrate coagulant enhanced the sand filter's performance producing effluents with high quality, enabling it to meet strict water reuse regulations as well as aquatic environmental and health preservations.
- Open Access
- 13 December 2021
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 71 (1) , 179-192
Design and assessment of water source alternatives for Mariout 2 water treatment plant extension
Factors such as population increase and industrialization, coupled with the establishment of touristic villages, have necessitated an upgradation of water treatment plants (WTPs) in Egypt. In this study, three different water source alternatives were designed and compared with a simple decision matrix to select the most appropriate one for upgrading and extending the Mariout 2 WTP. The first two alternatives are located on the k-40 Alex-Cairo desert road and k-77 EL Nasr canal, respectively, where the water source is obtained from the Nile River. The third alternative is located at the k-51 Alex-Matrouh coastal road and a non-conventional seawater source is used. The design results showed that the required energy power of the first, second, and third alternatives were 0.31, 0.066, and 0.72 kw/purified m3, respectively. The operational costs of the first, second, and third alternatives were 0.665, 0.426, and 6.621 EGP/m3, respectively. The cost of the intake pipes was found to be the lowest for the third alternative, whereas it was found to be the highest for the first one. Based on the results obtained from the decision matrix, the third alternative was found to be the most appropriate alternative followed by the second one. This study may assist in making decisions regarding the water source selection and treatment methods for the extension of the fourth stage of the Mariout 2 WTP.
- 13 December 2021
- Published by IWA Publishing in Journal of Water Supply: Research and Technology—AQUA
- Vol. 71 (1) , 179-192
Open AccessDesign and assessment of water source alternatives for Mariout 2 water treatment plant extension
Factors such as population increase and industrialization, coupled with the establishment of touristic villages, have necessitated an upgradation of water treatment plants (WTPs) in Egypt. In this study, three different water source alternatives were designed and compared with a simple decision matrix to select the most appropriate one for upgrading and extending the Mariout 2 WTP. The first two alternatives are located on the k-40 Alex-Cairo desert road and k-77 EL Nasr canal, respectively, where the water source is obtained from the Nile River. The third alternative is located at the k-51 Alex-Matrouh coastal road and a non-conventional seawater source is used. The design results showed that the required energy power of the first, second, and third alternatives were 0.31, 0.066, and 0.72 kw/purified m3, respectively. The operational costs of the first, second, and third alternatives were 0.665, 0.426, and 6.621 EGP/m3, respectively. The cost of the intake pipes was found to be the lowest for the third alternative, whereas it was found to be the highest for the first one. Based on the results obtained from the decision matrix, the third alternative was found to be the most appropriate alternative followed by the second one. This study may assist in making decisions regarding the water source selection and treatment methods for the extension of the fourth stage of the Mariout 2 WTP.
- Open Access
- 26 November 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (23) , 13125
Cost Analysis and Health Risk Assessment of Wastewater Reuse from Secondary and Tertiary Wastewater Treatment Plants
Irrigation with reclaimed water is a widespread solution to coping with water scarcity, especially in the Middle East and North Africa (MENA) region. This paper presents a systematic evaluation approach of six treatment alternatives proposed for Alexandria WWTP in Egypt as an applied example. This approach evaluates the effluent quality and cubic meter price from the proposed treatment alternatives while managing the health risks associated with reclaimed water irrigation. Rotavirus, Salmonella, Giardia duodenalis, and Ascaris were studied as waterborne pathogens. A quantitative microbial risk assessment model was used for the estimation of annual infection risks. The exposure scenarios include farmers and vegetable consumers. Activated sludge provided the lowest costs; however, it gave the lowest efficiencies and highest health risks. On the other hand, the highest efficiency and lowest health risks were obtained by the membrane bioreactor. The resulting price of a cubic meter of treated wastewater, used in irrigation, ranged from 0.082 to 0.133 USD. Irrigation using tertiary-treated wastewater achieved the target infection risk for unrestricted irrigation without using advanced treatment facilities. The results of this study could give a comprehensive view of reusing wastewater to decision-makers to address both water and food poverty not only in Egypt but also in other countries in MENA with similar economic and agro-ecological conditions.
- 26 November 2021
- Published by MDPI AG in Sustainability
- Vol. 13 (23) , 13125
Open AccessCost Analysis and Health Risk Assessment of Wastewater Reuse from Secondary and Tertiary Wastewater Treatment Plants
Irrigation with reclaimed water is a widespread solution to coping with water scarcity, especially in the Middle East and North Africa (MENA) region. This paper presents a systematic evaluation approach of six treatment alternatives proposed for Alexandria WWTP in Egypt as an applied example. This approach evaluates the effluent quality and cubic meter price from the proposed treatment alternatives while managing the health risks associated with reclaimed water irrigation. Rotavirus, Salmonella, Giardia duodenalis, and Ascaris were studied as waterborne pathogens. A quantitative microbial risk assessment model was used for the estimation of annual infection risks. The exposure scenarios include farmers and vegetable consumers. Activated sludge provided the lowest costs; however, it gave the lowest efficiencies and highest health risks. On the other hand, the highest efficiency and lowest health risks were obtained by the membrane bioreactor. The resulting price of a cubic meter of treated wastewater, used in irrigation, ranged from 0.082 to 0.133 USD. Irrigation using tertiary-treated wastewater achieved the target infection risk for unrestricted irrigation without using advanced treatment facilities. The results of this study could give a comprehensive view of reusing wastewater to decision-makers to address both water and food poverty not only in Egypt but also in other countries in MENA with similar economic and agro-ecological conditions.
- 30 November 2020
- Published by IWA Publishing in Water Science & Technology
- Vol. 83 (2) , 284-296
In-line coagulation assessment for ultrafiltration fouling reduction to treat secondary effluent for water reuse
Low pressure membranes are attracting attention for their potential to improve secondary effluent quality, but membrane fouling can limit their widespread applicability. In this study, in-line coagulation as pre-treatment to ultrafiltration was investigated using a bench-scale hollow fiber membrane at a constant flux of 33 L/m2 h (LMH). Membrane fouling was monitored by observing change in trans-membrane pressure (TMP) when the membrane was fed with secondary effluent and in-line coagulated secondary effluent over a 24 h period. The impact of four coagulants at different dosages on reversible and irreversible membrane fouling and permeate quality was studied. It was found that in-line coagulation improved UF performance to varying degrees depending on coagulant type and dosage. Generally, higher reduction of fouling was achieved by increasing coagulant dosage within the 0.5–5.0 mg/L range investigated. Ferric-based coagulants were better than aluminum-based coagulants with respect to improving membrane performance for the secondary effluent investigated, even at low dosages (0.5 mg/L). Further investigations are required to determine how in-line coagulation affects removal of organic compounds through ultrafiltration membranes.
- 30 November 2020
- Published by IWA Publishing in Water Science & Technology
- Vol. 83 (2) , 284-296
In-line coagulation assessment for ultrafiltration fouling reduction to treat secondary effluent for water reuse
Low pressure membranes are attracting attention for their potential to improve secondary effluent quality, but membrane fouling can limit their widespread applicability. In this study, in-line coagulation as pre-treatment to ultrafiltration was investigated using a bench-scale hollow fiber membrane at a constant flux of 33 L/m2 h (LMH). Membrane fouling was monitored by observing change in trans-membrane pressure (TMP) when the membrane was fed with secondary effluent and in-line coagulated secondary effluent over a 24 h period. The impact of four coagulants at different dosages on reversible and irreversible membrane fouling and permeate quality was studied. It was found that in-line coagulation improved UF performance to varying degrees depending on coagulant type and dosage. Generally, higher reduction of fouling was achieved by increasing coagulant dosage within the 0.5–5.0 mg/L range investigated. Ferric-based coagulants were better than aluminum-based coagulants with respect to improving membrane performance for the secondary effluent investigated, even at low dosages (0.5 mg/L). Further investigations are required to determine how in-line coagulation affects removal of organic compounds through ultrafiltration membranes.
- Open Access
- 22 February 2017
- Published by IWA Publishing in Journal of Water Reuse and Desalination
- Vol. 8 (2) , 176-191
Biological filtration with and without prior in-line coagulation to reduce UF fouling by secondary effluent
The objectives of this research were to investigate biofiltration prior to ultrafiltration (UF) for treatment of secondary effluent. Biofiltration with and without prior in-line coagulation was assessed for UF membrane fouling reduction. Two parallel pilot-scale biofilters, each with different media (sand vs. anthracite), were operated under identical conditions at a hydraulic loading rate of 0.75 m/h. A component of this investigation included the in-line application of a 1.0 mg/L dose of ferric sulfate prior to an anthracite biofilter. All UF membrane fouling experiments were conducted at bench-scale at a constant flux of 32 L/m2h (LMH). The sand (BF1) and anthracite biofilters (BF2) removed on average 25 and 20%, respectively, of the biopolymer fraction of the effluent organic matter. Humic substances were less well removed at about 10%, while biofilter influent turbidity was reduced by 75 and 70% through BF1 and BF2, respectively. Feeding the UF membrane with biofilter effluent (no prior coagulant addition) substantially reduced both hydraulically reversible and irreversible membrane fouling by up to 60 and 80%, respectively. Hydraulically reversible and irreversible fouling were further reduced (up to 69 and 87%, respectively) by the integration of the in-line coagulation/biofiltration pre-treatment processes compared to biofiltration alone.
- 22 February 2017
- Published by IWA Publishing in Journal of Water Reuse and Desalination
- Vol. 8 (2) , 176-191
Open AccessBiological filtration with and without prior in-line coagulation to reduce UF fouling by secondary effluent
The objectives of this research were to investigate biofiltration prior to ultrafiltration (UF) for treatment of secondary effluent. Biofiltration with and without prior in-line coagulation was assessed for UF membrane fouling reduction. Two parallel pilot-scale biofilters, each with different media (sand vs. anthracite), were operated under identical conditions at a hydraulic loading rate of 0.75 m/h. A component of this investigation included the in-line application of a 1.0 mg/L dose of ferric sulfate prior to an anthracite biofilter. All UF membrane fouling experiments were conducted at bench-scale at a constant flux of 32 L/m2h (LMH). The sand (BF1) and anthracite biofilters (BF2) removed on average 25 and 20%, respectively, of the biopolymer fraction of the effluent organic matter. Humic substances were less well removed at about 10%, while biofilter influent turbidity was reduced by 75 and 70% through BF1 and BF2, respectively. Feeding the UF membrane with biofilter effluent (no prior coagulant addition) substantially reduced both hydraulically reversible and irreversible membrane fouling by up to 60 and 80%, respectively. Hydraulically reversible and irreversible fouling were further reduced (up to 69 and 87%, respectively) by the integration of the in-line coagulation/biofiltration pre-treatment processes compared to biofiltration alone.