Amr Mohamed Sayed-Ahmed Abdelkader
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Amr Mohamed Sayed-Ahmed Abdelkader has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Ahmed Elreedy
1 shared publication- Alaa M. Metwally1 shared publication
Elbarqi Walid
1 shared publicationMedhat A. E. Moustafa
1 shared publication- Samia Ahmed Abdelrahman Aly
Sanitary Engineering Department, Faculty of Engineering, Alexandria University, Alexandria, Egypt
1 shared publication - Sarah Osama Makled
Oceanography Department, Faculty of Science, Alexandria University, Alexandria, Egypt
1 shared publication
Latest Publications
- Open Access
- 11 September 2025
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 130, 115-138
Biosorption of methylene blue from industrial wastewater using silicon dioxide nanoparticles and Cladophora glomerata
- 11 September 2025
- Published by Elsevier in Alexandria Engineering Journal
- Vol. 130, 115-138
Open AccessBiosorption of methylene blue from industrial wastewater using silicon dioxide nanoparticles and Cladophora glomerata
- Open Access
- 1 January 2021
- Published by EJournal Publishing in International Journal of Environmental Science and Development
- Vol. 12 (4) , 107-111
Comparative Study between Membrane Bioreactor MBR and Rotating Biological Contactors RBC for Greywater Treatment
Greywater is the major part of water consumption in houses. Greywater should be treated to complying with the specifications for several purposes such as toilet flush, landscaping irrigation, and agriculture. The treatment efficiency of both MBR and RBC systems was investigated by using a verified mathematical model. The simulation program GPS-X (version 6.0) was used to simulate both MBR and RBC systems. The simulation model for biological treatment for both MBR and RBC systems is based on Activated Sludge Model 1 (ASM1). The experimental data for model calibration and verification for the MBR system were taken from experimental work done at Tubitak, Marmara Research Center, Turkey ATASOY. As well as the RBC proposed model was verified also by using RBC experimental results for a pilot plant according to BABAN. The RBC pilot plant consists of three units, The first is the RBC unit, the second unit is the settling tank and the last unit is the disinfection tank. The results of the MBR plant showed that the removal efficiencies of the greywater were: 95% for COD; 95% for BOD5; 96% for TKN; 92% for NH4+ and 99% for TSS. Whereas, the results of the RBC show that, The BOD efficiency removal was ranged between about 93.0 to 96.0 %, and for the total SS removal was ranged between 84.0 to 95.0 %. The MBR system provides complete nitrification and suspended solid removal. The RBC system provides less nitrification process and suspended solid removal. The effluent of the rotating biological contactors units for the greywater could be reused after filtration and disinfection with minimal cost of operation. The effluent of the membrane bioreactor unit needs only disinfection before reuse.
- 1 January 2021
- Published by EJournal Publishing in International Journal of Environmental Science and Development
- Vol. 12 (4) , 107-111
Open AccessComparative Study between Membrane Bioreactor MBR and Rotating Biological Contactors RBC for Greywater Treatment
Greywater is the major part of water consumption in houses. Greywater should be treated to complying with the specifications for several purposes such as toilet flush, landscaping irrigation, and agriculture. The treatment efficiency of both MBR and RBC systems was investigated by using a verified mathematical model. The simulation program GPS-X (version 6.0) was used to simulate both MBR and RBC systems. The simulation model for biological treatment for both MBR and RBC systems is based on Activated Sludge Model 1 (ASM1). The experimental data for model calibration and verification for the MBR system were taken from experimental work done at Tubitak, Marmara Research Center, Turkey ATASOY. As well as the RBC proposed model was verified also by using RBC experimental results for a pilot plant according to BABAN. The RBC pilot plant consists of three units, The first is the RBC unit, the second unit is the settling tank and the last unit is the disinfection tank. The results of the MBR plant showed that the removal efficiencies of the greywater were: 95% for COD; 95% for BOD5; 96% for TKN; 92% for NH4+ and 99% for TSS. Whereas, the results of the RBC show that, The BOD efficiency removal was ranged between about 93.0 to 96.0 %, and for the total SS removal was ranged between 84.0 to 95.0 %. The MBR system provides complete nitrification and suspended solid removal. The RBC system provides less nitrification process and suspended solid removal. The effluent of the rotating biological contactors units for the greywater could be reused after filtration and disinfection with minimal cost of operation. The effluent of the membrane bioreactor unit needs only disinfection before reuse.
- Open Access
- 1 July 2013
- Published by Springer Nature in Journal of King Saud University – Engineering Sciences
- Vol. 25 (2) , 89-95
Studying the efficiency of grey water treatment by using rotating biological contactors system
- 1 July 2013
- Published by Springer Nature in Journal of King Saud University – Engineering Sciences
- Vol. 25 (2) , 89-95
Open AccessStudying the efficiency of grey water treatment by using rotating biological contactors system
- Open Access
- 1 March 2013
- Published by Egyptian Knowledge Bank in Port-Said Engineering Research Journal
- Vol. 17 (1) , 100-105
Assessment Of The MBR System For Segregated Household Wastewater By Using Simulation Mathematical Model
Domestic water recycling for several purposes is regarded as an attractive option for the countries where a water scarcity is prevailing. Two groups of wastewater streams are usually recognized as black and grey water at household level. This study analyses the reliability of an on-site MBR system for segregated household wastewater treatment and reuse. To achieve this goal simulation model was developed based on the IWA Activated Sludge Model 1 (ASM1). The MBR model was adapted to describe biological and physical mechanisms for the MBR system. The GPS-X (version 5.0) simulation program was used in this study to simulate the proposed MBR plant model. The experimental data which used on the model calibration and verification were taken from experimental work done at Tubitak, Marmara Research Center, Turkey. Model results were found to agree well with experimental data from two MBRs pilot plants. The grey and black water originated from lodging houses were used as influent wastewater for the two MBRs pilot plants. The two pilot plants were operated for a period of 50 days with hydraulic retention time (HRT) of 18 and 36h respectively for grey and black water. The average removal efficiencies were, 95% COD, 92% TN, and 99% TSS for grey water and 96% COD, 89% TN, and 99% TSS for black water. The results showed that the effluent quality of grey and black water treated by the MBR complied with the international reuse criteria for different uses. The MBR plant model is powerful tool for optimizing the treatment process and improving the plant operations. Also, the model can be saving significant cost by predicting the outcome of operational changes, as well as, by performing an energy cost analysis.
- 1 March 2013
- Published by Egyptian Knowledge Bank in Port-Said Engineering Research Journal
- Vol. 17 (1) , 100-105
Open AccessAssessment Of The MBR System For Segregated Household Wastewater By Using Simulation Mathematical Model
Domestic water recycling for several purposes is regarded as an attractive option for the countries where a water scarcity is prevailing. Two groups of wastewater streams are usually recognized as black and grey water at household level. This study analyses the reliability of an on-site MBR system for segregated household wastewater treatment and reuse. To achieve this goal simulation model was developed based on the IWA Activated Sludge Model 1 (ASM1). The MBR model was adapted to describe biological and physical mechanisms for the MBR system. The GPS-X (version 5.0) simulation program was used in this study to simulate the proposed MBR plant model. The experimental data which used on the model calibration and verification were taken from experimental work done at Tubitak, Marmara Research Center, Turkey. Model results were found to agree well with experimental data from two MBRs pilot plants. The grey and black water originated from lodging houses were used as influent wastewater for the two MBRs pilot plants. The two pilot plants were operated for a period of 50 days with hydraulic retention time (HRT) of 18 and 36h respectively for grey and black water. The average removal efficiencies were, 95% COD, 92% TN, and 99% TSS for grey water and 96% COD, 89% TN, and 99% TSS for black water. The results showed that the effluent quality of grey and black water treated by the MBR complied with the international reuse criteria for different uses. The MBR plant model is powerful tool for optimizing the treatment process and improving the plant operations. Also, the model can be saving significant cost by predicting the outcome of operational changes, as well as, by performing an energy cost analysis.