  • Transpedicular Approach on a Novel Spine Simulator: A Validation Study

    by David Fürst, Marianne Hollensteiner, Stefan Gabauer, Benjamin Esterer, Klemens Trieb, Felix Eckstein, Andreas Schrempf


  • Procedure-Specific Validation of Artificial Vertebrae

    by Marianne Hollensteiner, David Fürst, Peter Augat, Benjamin Esterer, Falk Schrödl, Stefan Gabauer, Klaus Püschel, Andreas Schrempf

    Objective: The development of a novel hybrid patient simulator was initiated to provide a safe training possibility for novice surgeons. Integrated artificial vertebrae should be able to realistically mimic the haptics of transpedicular Vertebroplasty instrument insertion and pedicle screw placement. Therefore, new open-celled material compositions were developed, tested and validated with reference to elderly human vertebrae. Methods: Vertebroplasty tool insertion force and pedicle screw torque measurements were performed. To validate the new bone surrogates for transpedicular tool insertion, a novel parametric model of the procedure was developed identifying three characteristic insertion parameters (weighting factors, cutting and clamping forces). Furthermore, the slope of the insertion torque was used to validate the new materials against the human vertebrae for pedicle screw placement. Results: A relative error less than 6% confirmed the suitability of the parametric model for validation. The weighting factors ($28.8 \pm 10.6$) and the clamping forces ($3.7 \pm 1.5\ N/mm$) of the human reference were met by the bone surrogate with 1.25% of blowing agent ($22.3\pm 7.6$ and $3.0\pm 0.3\ N/mm$, respectively). However, no material was able to reflect the instrument cutting forces. The slope obtained during pedicle screw placement in human vertebrae was $96.0\pm 12.4\ Nm/m$. The material composition with 1% blowing agent achieved similar results ($97.6\pm 14.3\ Nm/m$). Conclusion: Two suitable materials which deliver realistic haptics during both instrument insertions were validated. The parametric model suitably modeled the transpedicular instrument insertion. Significance: These newly developed models provide a realistic haptic feedback during transpedicular instrument insertions with the potential of cement application during surgical skill training.


  • Characterization of synthetic foam structures used to manufacture artificial vertebral trabecular bone

    by David Fürst, Sascha Senck, Marianne Hollensteiner, Benjamin Esterer, Peter Augat, Felix Eckstein, Andreas Schrempf


  • Open Access

    Development of parietal bone surrogates for parietal graft lift training

    by Marianne Hollensteiner, David Fürst, Benjamin Esterer, Stefan Hunger, Michael Malek, Peter Augat, Falk Schrödl, Daniel Stephan, Andreas Schrempf

    Currently the surgical training of parietal bone graft techniques is performed on patients or specimens. Commercially available bone models do not deliver realistic haptic feedback. Thus customized parietal skull surrogates were developed for surgical training purposes. Two human parietal bones were used as reference. Based on the measurement of insertion forces of drilling, milling and saw procedures suitable material compositions for molding cortical and cancellous calvarial layers were found. Artificial skull caps were manufactured and tested. Additionally microtomograpy images of human and artificial parietal bones were performed to analyze outer table and diploe thicknesses. Significant differences between human and artificial skulls were not detected with the mechanical procedures tested. Highly significant differences were found for the diploe thickness values. In conclusion, an artificial bone has been created, mimicking the properties of human parietal bone thus being suitable for tabula externa graft lift training.