Felix Güttler
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Felix Güttler has a total of 75 co-authors. Here are the top co-authors by number of shared publications:
- Ulf Teichgräber
Department of Radiology, Jena University Hospital, Friedrich Schiller University Jena, Jena, Germany
13 shared publications - Andreas Heinrich
Department of Radiology, Jena University Hospital – Friedrich Schiller University, Jena, Germany
9 shared publications - Martin Krämer
Medical Physics Group, Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, Germany; Institute of Diagnostic and Interventional Radiology, Jena University Hospital, Friedrich Schiller University Jena, Germany
4 shared publications - Alexander Pfeil
Rheumazentrum (G-BA-Regeln) sowie Sektion Rheumatologie und Osteologie, Klinik für Innere Medizin III, Universitätsklinikum Jena, Friedrich-Schiller-Universität Jena, Jena, Deutschland
2 shared publications - Bianca Lassen-Schmidt
Fraunhofer Institute for Digital Medicine MEVIS, Bremen, Germany
2 shared publications - Diane Miriam Renz
Institut für Diagnostische und Interventionelle Radiologie, Arbeitsbereich Kinderradiologie, Medizinische Hochschule Hannover, Hannover, Deutschland
2 shared publications
Latest Publications
- Open Access
- 12 August 2025
- Published by Springer Nature in Rheumatology International
- Vol. 45 (9) , 1-12
The association of symptoms, pulmonary function test and computed tomography in interstitial lung disease at the onset of connective tissue disease: an observational study with artificial intelligence analysis of high-resolution computed tomography
Interstitial lung disease (ILD) is a common and serious organ manifestation in patients with connective tissue disease (CTD), but it is uncertain whether there is a difference in ILD between symptomatic and asymptomatic patients. Therefore, we conducted a study to evaluate differences in the extent of ILD based on radiological findings between symptomatic/asymptomatic patients, using an artificial intelligence (AI)-based quantification of pulmonary high-resolution computed tomography (AIpqHRCT). Within the study, 67 cross-sectional HRCT datasets and clinical data (including pulmonary function test) of consecutively patients (mean age: 57.1 ± 14.7 years, woman n = 45; 67.2%) with both, initial diagnosis of CTD, with systemic sclerosis being the most frequent (n = 21, 31.3%), and ILD (all without immunosuppressive therapy), were analysed using AIqpHRCT. 25.4% (n = 17) of the patients with ILD at initial diagnosis of CTD had no pulmonary symptoms. Regarding the baseline characteristics (age, gender, disease), there were no significant difference between the symptomatic and asymptomatic group. The pulmonary function test (PFT) revealed the following mean values (%predicted) in the symptomatic and asymptomatic group, respectively: Forced vital capacity (FVC) 69.4 ± 17.4% versus 86.1 ± 15.8% (p = 0.001), and diffusing capacity of the lung for carbon monoxide (DLCO) 49.7 ± 17.9% versus 60.0 ± 15.8% (p = 0.043). AIqpHRCT data showed a significant higher amount of high attenuated volume (HAV) (14.8 ± 11.0% versus 8.9 ± 3.9%; p = 0.021) and reticulations (5.4 ± 8.7% versus 1.4 ± 1.5%; p = 0.035) in symptomatic patients. A quarter of patients with ILD at the time of initial CTD diagnosis had no pulmonary symptoms, showing DLCO were reduced in both groups. Also, AIqpHRCT demonstrated clinically relevant ILD in asymptomatic patients. These results underline the importance of an early risk adapted screening for ILD also in asymptomatic CTD patients, as ILD is associated with increased mortality.
- 12 August 2025
- Published by Springer Nature in Rheumatology International
- Vol. 45 (9) , 1-12
Open AccessThe association of symptoms, pulmonary function test and computed tomography in interstitial lung disease at the onset of connective tissue disease: an observational study with artificial intelligence analysis of high-resolution computed tomography
Interstitial lung disease (ILD) is a common and serious organ manifestation in patients with connective tissue disease (CTD), but it is uncertain whether there is a difference in ILD between symptomatic and asymptomatic patients. Therefore, we conducted a study to evaluate differences in the extent of ILD based on radiological findings between symptomatic/asymptomatic patients, using an artificial intelligence (AI)-based quantification of pulmonary high-resolution computed tomography (AIpqHRCT). Within the study, 67 cross-sectional HRCT datasets and clinical data (including pulmonary function test) of consecutively patients (mean age: 57.1 ± 14.7 years, woman n = 45; 67.2%) with both, initial diagnosis of CTD, with systemic sclerosis being the most frequent (n = 21, 31.3%), and ILD (all without immunosuppressive therapy), were analysed using AIqpHRCT. 25.4% (n = 17) of the patients with ILD at initial diagnosis of CTD had no pulmonary symptoms. Regarding the baseline characteristics (age, gender, disease), there were no significant difference between the symptomatic and asymptomatic group. The pulmonary function test (PFT) revealed the following mean values (%predicted) in the symptomatic and asymptomatic group, respectively: Forced vital capacity (FVC) 69.4 ± 17.4% versus 86.1 ± 15.8% (p = 0.001), and diffusing capacity of the lung for carbon monoxide (DLCO) 49.7 ± 17.9% versus 60.0 ± 15.8% (p = 0.043). AIqpHRCT data showed a significant higher amount of high attenuated volume (HAV) (14.8 ± 11.0% versus 8.9 ± 3.9%; p = 0.021) and reticulations (5.4 ± 8.7% versus 1.4 ± 1.5%; p = 0.035) in symptomatic patients. A quarter of patients with ILD at the time of initial CTD diagnosis had no pulmonary symptoms, showing DLCO were reduced in both groups. Also, AIqpHRCT demonstrated clinically relevant ILD in asymptomatic patients. These results underline the importance of an early risk adapted screening for ILD also in asymptomatic CTD patients, as ILD is associated with increased mortality.
- Open Access
- 25 October 2024
- Published by Elsevier in European Journal of Radiology
- Vol. 181, 111806
Image quality of virtual monochromatic and material density iodine images for evaluation of head and neck neoplasms using deep learning-based CT image reconstruction – A retrospective observational study
- 25 October 2024
- Published by Elsevier in European Journal of Radiology
- Vol. 181, 111806
Open AccessImage quality of virtual monochromatic and material density iodine images for evaluation of head and neck neoplasms using deep learning-based CT image reconstruction – A retrospective observational study
- Open Access
- 9 September 2024
- Published by Springer Nature in Rheumatology International
- Vol. 44 (11) , 2483-2496
Artificial intelligence-based quantification of pulmonary HRCT (AIqpHRCT) for the evaluation of interstitial lung disease in patients with inflammatory rheumatic diseases
High-resolution computed tomography (HRCT) is important for diagnosing interstitial lung disease (ILD) in inflammatory rheumatic disease (IRD) patients. However, visual ILD assessment via HRCT often has high inter-reader variability. Artificial intelligence (AI)-based techniques for quantitative image analysis promise more accurate diagnostic and prognostic information. This study evaluated the reliability of artificial intelligence-based quantification of pulmonary HRCT (AIqpHRCT) in IRD-ILD patients and verified IRD-ILD quantification using AIqpHRCT in the clinical setting. Reproducibility of AIqpHRCT was verified for each typical HRCT pattern (ground-glass opacity [GGO], non-specific interstitial pneumonia [NSIP], usual interstitial pneumonia [UIP], granuloma). Additional, 50 HRCT datasets from 50 IRD-ILD patients using AIqpHRCT were analysed and correlated with clinical data and pulmonary lung function parameters. AIqpHRCT presented 100% agreement (coefficient of variation = 0.00%, intraclass correlation coefficient = 1.000) regarding the detection of the different HRCT pattern. Furthermore, AIqpHRCT data showed an increase of ILD from 10.7 ± 28.3% (median = 1.3%) in GGO to 18.9 ± 12.4% (median = 18.0%) in UIP pattern. The extent of fibrosis negatively correlated with FVC (ρ=-0.501), TLC (ρ=-0.622), and DLCO (ρ=-0.693) (p < 0.001). GGO measured by AIqpHRCT also significant negatively correlated with DLCO (ρ=-0.699), TLC (ρ=-0.580) and FVC (ρ=-0.423). For the first time, the study demonstrates that AIpqHRCT provides a highly reliable method for quantifying lung parenchymal changes in HRCT images of IRD-ILD patients. Further, the AIqpHRCT method revealed significant correlations between the extent of ILD and lung function parameters. This highlights the potential of AIpqHRCT in enhancing the accuracy of ILD diagnosis and prognosis in clinical settings, ultimately improving patient management and outcomes.
- 9 September 2024
- Published by Springer Nature in Rheumatology International
- Vol. 44 (11) , 2483-2496
Open AccessArtificial intelligence-based quantification of pulmonary HRCT (AIqpHRCT) for the evaluation of interstitial lung disease in patients with inflammatory rheumatic diseases
High-resolution computed tomography (HRCT) is important for diagnosing interstitial lung disease (ILD) in inflammatory rheumatic disease (IRD) patients. However, visual ILD assessment via HRCT often has high inter-reader variability. Artificial intelligence (AI)-based techniques for quantitative image analysis promise more accurate diagnostic and prognostic information. This study evaluated the reliability of artificial intelligence-based quantification of pulmonary HRCT (AIqpHRCT) in IRD-ILD patients and verified IRD-ILD quantification using AIqpHRCT in the clinical setting. Reproducibility of AIqpHRCT was verified for each typical HRCT pattern (ground-glass opacity [GGO], non-specific interstitial pneumonia [NSIP], usual interstitial pneumonia [UIP], granuloma). Additional, 50 HRCT datasets from 50 IRD-ILD patients using AIqpHRCT were analysed and correlated with clinical data and pulmonary lung function parameters. AIqpHRCT presented 100% agreement (coefficient of variation = 0.00%, intraclass correlation coefficient = 1.000) regarding the detection of the different HRCT pattern. Furthermore, AIqpHRCT data showed an increase of ILD from 10.7 ± 28.3% (median = 1.3%) in GGO to 18.9 ± 12.4% (median = 18.0%) in UIP pattern. The extent of fibrosis negatively correlated with FVC (ρ=-0.501), TLC (ρ=-0.622), and DLCO (ρ=-0.693) (p < 0.001). GGO measured by AIqpHRCT also significant negatively correlated with DLCO (ρ=-0.699), TLC (ρ=-0.580) and FVC (ρ=-0.423). For the first time, the study demonstrates that AIpqHRCT provides a highly reliable method for quantifying lung parenchymal changes in HRCT images of IRD-ILD patients. Further, the AIqpHRCT method revealed significant correlations between the extent of ILD and lung function parameters. This highlights the potential of AIpqHRCT in enhancing the accuracy of ILD diagnosis and prognosis in clinical settings, ultimately improving patient management and outcomes.
- Open Access
- 22 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 207
Standardization of a CT Protocol for Imaging Patients with Suspected COVID-19—A RACOON Project
CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contrast protocols were evaluated. For this purpose, CT protocol parameters, IQ ratings, radiation exposure (CTDIvol), and central patient diameters were sampled. Eventually, the data from 14 sites and 534 CT acquisitions were analyzed. IQ was rated good for 81% of the evaluated examinations. Motion, beam-hardening artefacts, or image noise were reasons for a suboptimal IQ. The tube potential ranged between 80 and 140 kVp, with the majority between 100 and 120 kVp. CTDIvol was 3.7 ± 3.4 mGy. Most healthcare facilities included did not have a specific non-contrast CT protocol. Furthermore, CT protocols for chest imaging varied in their settings and radiation exposure. In future, it will be necessary to make recommendations regarding the required IQ and protocol parameters for the majority of CT scanners to enable comparable IQ as well as radiation exposure for different sites but identical diagnostic questions.
- 22 February 2024
- Published by MDPI AG in Bioengineering
- Vol. 11 (3) , 207
Open AccessStandardization of a CT Protocol for Imaging Patients with Suspected COVID-19—A RACOON Project
CT protocols that diagnose COVID-19 vary in regard to the associated radiation exposure and the desired image quality (IQ). This study aims to evaluate CT protocols of hospitals participating in the RACOON (Radiological Cooperative Network) project, consolidating CT protocols to provide recommendations and strategies for future pandemics. In this retrospective study, CT acquisitions of COVID-19 patients scanned between March 2020 and October 2020 (RACOON phase 1) were included, and all non-contrast protocols were evaluated. For this purpose, CT protocol parameters, IQ ratings, radiation exposure (CTDIvol), and central patient diameters were sampled. Eventually, the data from 14 sites and 534 CT acquisitions were analyzed. IQ was rated good for 81% of the evaluated examinations. Motion, beam-hardening artefacts, or image noise were reasons for a suboptimal IQ. The tube potential ranged between 80 and 140 kVp, with the majority between 100 and 120 kVp. CTDIvol was 3.7 ± 3.4 mGy. Most healthcare facilities included did not have a specific non-contrast CT protocol. Furthermore, CT protocols for chest imaging varied in their settings and radiation exposure. In future, it will be necessary to make recommendations regarding the required IQ and protocol parameters for the majority of CT scanners to enable comparable IQ as well as radiation exposure for different sites but identical diagnostic questions.
- Open Access
- 7 April 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 163, 110827
Added value of chest CT in a machine learning-based prediction model to rule out COVID-19 before inpatient admission: A retrospective university network study
- 7 April 2023
- Published by Elsevier in European Journal of Radiology
- Vol. 163, 110827
Open AccessAdded value of chest CT in a machine learning-based prediction model to rule out COVID-19 before inpatient admission: A retrospective university network study
- Open Access
Design of Reliable Remobilisation Finger Implants with Geometry Elements of a Triple Periodic Minimal Surface Structure via Additive Manufacturing of Silicon Nitride
When finger joints become immobile due to an accident during sports or a widespread disease such as rheumatoid arthritis, customised finger joint implants are to be created. In an automated process chain, implants will be produced from ceramic or metallic materials. Artificial intelligence-supported software is used to calculate three-dimensional models of the finger bones from two-dimensional X-ray images. Then, the individual implant design is derived from the finger model and 3D printed. The 3D printing process and the structures used are evaluated via model tests and the final implant design via a reliability calculation in a way to ensure that this is also possible via an AI process in the future. Using additive manufacturing with silicon nitride-based ceramics, model specimens and implants are produced via the lithography-based ceramic vat photopolymerisation process with full geometry or elements of triple periodic minimal surfaces structure. The model specimens are tested experimentally, and the loads are matched with a characteristic strength assuming a Weibull distribution of defects in the volume to generate and match failure probabilities. Calculated fracture forces of the silicon nitride-based ceramic structure was validated by comparison of simulation and tests, and the calculation can be used as a quality index for training of artificial intelligence in the future. The proposed method for individualized finger implant design and manufacturing may allow for correction of potential malpositions of the fingers in the future.
Open AccessDesign of Reliable Remobilisation Finger Implants with Geometry Elements of a Triple Periodic Minimal Surface Structure via Additive Manufacturing of Silicon Nitride
When finger joints become immobile due to an accident during sports or a widespread disease such as rheumatoid arthritis, customised finger joint implants are to be created. In an automated process chain, implants will be produced from ceramic or metallic materials. Artificial intelligence-supported software is used to calculate three-dimensional models of the finger bones from two-dimensional X-ray images. Then, the individual implant design is derived from the finger model and 3D printed. The 3D printing process and the structures used are evaluated via model tests and the final implant design via a reliability calculation in a way to ensure that this is also possible via an AI process in the future. Using additive manufacturing with silicon nitride-based ceramics, model specimens and implants are produced via the lithography-based ceramic vat photopolymerisation process with full geometry or elements of triple periodic minimal surfaces structure. The model specimens are tested experimentally, and the loads are matched with a characteristic strength assuming a Weibull distribution of defects in the volume to generate and match failure probabilities. Calculated fracture forces of the silicon nitride-based ceramic structure was validated by comparison of simulation and tests, and the calculation can be used as a quality index for training of artificial intelligence in the future. The proposed method for individualized finger implant design and manufacturing may allow for correction of potential malpositions of the fingers in the future.
- Open Access
- 10 March 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1
Author Correction: Systematic evaluation of particle loss during handling in the percutaneous transluminal angioplasty for eight different drug-coated balloons
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 10 March 2021
- Published by Springer Nature in Scientific Reports
- Vol. 11 (1) , 1
Open AccessAuthor Correction: Systematic evaluation of particle loss during handling in the percutaneous transluminal angioplasty for eight different drug-coated balloons
An amendment to this paper has been published and can be accessed via a link at the top of the paper.
- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (12) , 3420-3425
Development of an Apparatus for Digital Measurement of Magnetically Induced Torque on Medical Implants to Facilitate the Application of the ASTM F2213 Standard
Objective: The ASTM F2213 standard describes the measurement of the magnetically induced torques by means of a torsional spring method. As this method is highly complex, it has been rarely ever employed. The purpose was to develop an easy-to-handle measuring setup for the reproducible, fast and precise measurement of magnetically induced torques, following ASTM F2213, at a static magnetic field $(B_0)$ of 1.5 T and 3 T. Methods: An MR-safe measuring platform was developed according to the ASTM F2213 standard and combined with a precision balance. The evaluation was performed with 10 test objects, e.g. a steel screw (length 60 mm) and a neurostimulator, at 1.5 T and 3 T. The torque was measured at 10-degree increments as the test object was rotated relative to $B_0$ . Results: The measurement setup allows fast and reproducible measurements. The maximum magnetically induced torque measured was $\rm 397 \pm 2 N\cdot mm$ for the steel screw and $\rm 63 \pm 1 N\cdot mm$ for the neurostimulator. The maximum torque on a test object is insensitive to $B_0$ if the magnetization of the object has reached saturation. Conclusion: Ferromagnetic implants may exhibit strong magnetically induced torques during MRI examination. For analyzing these magnetically induced torques, we developed a digital measuring device that allows simplified and accelerated application of the ASTM F2213 standard test method. Significance: In a $B_0$ , ferromagnetic implants may exert considerable torques on the surrounding tissue. These forces may affect the functionality of the implant and inflict severe injuries on a patient.- 15 March 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 66 (12) , 3420-3425
Development of an Apparatus for Digital Measurement of Magnetically Induced Torque on Medical Implants to Facilitate the Application of the ASTM F2213 Standard
Objective: The ASTM F2213 standard describes the measurement of the magnetically induced torques by means of a torsional spring method. As this method is highly complex, it has been rarely ever employed. The purpose was to develop an easy-to-handle measuring setup for the reproducible, fast and precise measurement of magnetically induced torques, following ASTM F2213, at a static magnetic field $(B_0)$ of 1.5 T and 3 T. Methods: An MR-safe measuring platform was developed according to the ASTM F2213 standard and combined with a precision balance. The evaluation was performed with 10 test objects, e.g. a steel screw (length 60 mm) and a neurostimulator, at 1.5 T and 3 T. The torque was measured at 10-degree increments as the test object was rotated relative to $B_0$ . Results: The measurement setup allows fast and reproducible measurements. The maximum magnetically induced torque measured was $\rm 397 \pm 2 N\cdot mm$ for the steel screw and $\rm 63 \pm 1 N\cdot mm$ for the neurostimulator. The maximum torque on a test object is insensitive to $B_0$ if the magnetization of the object has reached saturation. Conclusion: Ferromagnetic implants may exhibit strong magnetically induced torques during MRI examination. For analyzing these magnetically induced torques, we developed a digital measuring device that allows simplified and accelerated application of the ASTM F2213 standard test method. Significance: In a $B_0$ , ferromagnetic implants may exert considerable torques on the surrounding tissue. These forces may affect the functionality of the implant and inflict severe injuries on a patient.- 27 June 2017
- Published by ASME International in Journal of Medical Devices
- Vol. 11 (3)
RFID-Based Real-Time Navigation for Interventional Magnetic Resonance Imaging: Development and Evaluation of a Novel Tracking System
The purpose of this study was to evaluate the suitability of a novel radio-frequency identification (RFID)-based tracking system for intraoperative magnetic resonance imaging (MRI). A RFID tracking system was modified to fulfill MRI-compatibility and tested according to ASTM and NEMA. The influence of the RFID tracking system on MRI was analyzed in a phantom study using a half-Fourier acquisition single-shot turbospin echo (HASTE) and true fast imaging with steady-state precession sequence (TrueFISP) sequence. The RFID antenna was gradually moved closer to the isocenter of the MR scanner from 90 to 210 cm to investigate the influence of the distance. Furthermore, the RF was gradually changed between 865 and 869 MHz for a distance of 90 cm, 150 cm, and 210 cm to the isocenter of the magnet to investigate the influence of the frequency. The specific spatial resolution was measured with and without a permanent line of sight (LOS). After the modification of the reader, no significant change of the signal-to-noise ratio (SNR) could be observed with increasing distance of the RFID tracking system to the isocenter of the MR scanner. Also, different radio frequencies of the RFID tracking system did not influence the SNR of the MR-images significantly. The specific spatial resolution deviated on average by 8.97 ± 7.33 mm with LOS and 11.23 ± 12.03 mm without LOS from the reference system. The RFID tracking system had no relevant influence on the MR-image quality. RFID tracking solved the LOS problem. However, the spatial accuracy of the RFID tracking system has to be improved for medical usage.
- 27 June 2017
- Published by ASME International in Journal of Medical Devices
- Vol. 11 (3)
RFID-Based Real-Time Navigation for Interventional Magnetic Resonance Imaging: Development and Evaluation of a Novel Tracking System
The purpose of this study was to evaluate the suitability of a novel radio-frequency identification (RFID)-based tracking system for intraoperative magnetic resonance imaging (MRI). A RFID tracking system was modified to fulfill MRI-compatibility and tested according to ASTM and NEMA. The influence of the RFID tracking system on MRI was analyzed in a phantom study using a half-Fourier acquisition single-shot turbospin echo (HASTE) and true fast imaging with steady-state precession sequence (TrueFISP) sequence. The RFID antenna was gradually moved closer to the isocenter of the MR scanner from 90 to 210 cm to investigate the influence of the distance. Furthermore, the RF was gradually changed between 865 and 869 MHz for a distance of 90 cm, 150 cm, and 210 cm to the isocenter of the magnet to investigate the influence of the frequency. The specific spatial resolution was measured with and without a permanent line of sight (LOS). After the modification of the reader, no significant change of the signal-to-noise ratio (SNR) could be observed with increasing distance of the RFID tracking system to the isocenter of the MR scanner. Also, different radio frequencies of the RFID tracking system did not influence the SNR of the MR-images significantly. The specific spatial resolution deviated on average by 8.97 ± 7.33 mm with LOS and 11.23 ± 12.03 mm without LOS from the reference system. The RFID tracking system had no relevant influence on the MR-image quality. RFID tracking solved the LOS problem. However, the spatial accuracy of the RFID tracking system has to be improved for medical usage.
- 7 August 2015
- Published by Springer Nature in Der Radiologe
- Vol. 55 (8) , 649-653
Ganzkörperferrodetektorsysteme in der klinischen MRT
Klinisches/methodisches Problem Trotz organisatorischer und technischer Vorkehrungen haben ferromagnetische Gegenstände im MRT-Raum bis heute immer wieder teilweise schwere Unfälle verursacht. Radiologische Standardverfahren Eine umfangreiche Patientenaufklärung und ein MRT-Sicherheitstraining für die Mitarbeiter sollen durch ferromagnetische Objekte hervorgerufene Zwischenfälle, verhindern. Methodische Innovationen Aktive Sicherheitssysteme zur Detektion ferromagnetischer Metalle sollen die Sicherheit von Patienten und Personal verbessern und Sachschäden am Gerät verhindern. Leistungsfähigkeit In einer klinischen MRT-Umgebung identifizierte ein Ganzkörperferrodetektorsystem als separater Messplatz bei 2 % der stationären und ambulanten Patienten (n = 400) unbekannte ferromagnetische Objekte. Davon besaßen 2 Patienten unbekannte ferromagnetische Fremdkörper. Ein weiterer Ferrodetektor als Durchgangskontrollsystem identifizierte, bei ausschließlich ambulanten Patienten (n = 2500) in 0,3 % der Fälle unbekannte ferromagnetische Objekte. Bewertung Die Zahl der ferromagnetischen Objekte, welche unbewusst in den Magnetraum gelangen, können mit dem Einsatz eines Ganzkörperferrodetektorsystems verringert werden. Der optimale Nutzen des Systems kann nur erreicht werden, wenn das medizinische Personal und die Untersuchungsumgebung vollständig frei von beweglichen ferromagnetischen Materialien sind. In der klinischen Routine bestehen insbesondere praktische Einschränkungen des potenziellen Nutzens für liegende Patienten. Empfehlung für die Praxis Ein Ganzkörperferrodetektorsystem kann die Patientenaufklärung und das MRT-Sicherheitstraining nicht ersetzen, jedoch sinnvoll ergänzen. Clinical/methodical issue In spite of technical and organizational measures, ferromagnetic objects still find their way into the magnetic resonance imaging (MRI) room and can cause severe injuries. Standard radiological methods A detailed patient education and MRI safety training for personnel are necessary to avoid MRI incidents with ferromagnetic objects. Methodical innovations Whole body ferromagnetic detection systems should increase patient safety and minimize risks for personnel and MRI equipment in the clinical routine. Performance In a clinical MRI setting, a screener system used for outpatients and inpatients (n = 400) identified unknown ferrous objects in 2 % of the cases. In two of these cases patients were found to be in possession of unknown foreign ferrous objects. Furthermore, a door guard system only used for outpatients (n = 2500) detected unknown ferromagnetic objects in 0.3 % of the cases. Achievements The number of ferrous objects that are unknowingly brought into the scanner room can be reduced with a whole body ferromagnetic detection system. For an optimal benefit of the system a ferrous-free environment and perfectly ferrous-free clothing for the medical personnel are necessary. In the clinical routine, the benefit of the system is limited particularly for immobile patients who have to remain in a horizontal position. Practical recommendations A whole body ferromagnetic detection system can complement but not replace patient education and MRI safety training.
- 7 August 2015
- Published by Springer Nature in Der Radiologe
- Vol. 55 (8) , 649-653
Ganzkörperferrodetektorsysteme in der klinischen MRT
Klinisches/methodisches Problem Trotz organisatorischer und technischer Vorkehrungen haben ferromagnetische Gegenstände im MRT-Raum bis heute immer wieder teilweise schwere Unfälle verursacht. Radiologische Standardverfahren Eine umfangreiche Patientenaufklärung und ein MRT-Sicherheitstraining für die Mitarbeiter sollen durch ferromagnetische Objekte hervorgerufene Zwischenfälle, verhindern. Methodische Innovationen Aktive Sicherheitssysteme zur Detektion ferromagnetischer Metalle sollen die Sicherheit von Patienten und Personal verbessern und Sachschäden am Gerät verhindern. Leistungsfähigkeit In einer klinischen MRT-Umgebung identifizierte ein Ganzkörperferrodetektorsystem als separater Messplatz bei 2 % der stationären und ambulanten Patienten (n = 400) unbekannte ferromagnetische Objekte. Davon besaßen 2 Patienten unbekannte ferromagnetische Fremdkörper. Ein weiterer Ferrodetektor als Durchgangskontrollsystem identifizierte, bei ausschließlich ambulanten Patienten (n = 2500) in 0,3 % der Fälle unbekannte ferromagnetische Objekte. Bewertung Die Zahl der ferromagnetischen Objekte, welche unbewusst in den Magnetraum gelangen, können mit dem Einsatz eines Ganzkörperferrodetektorsystems verringert werden. Der optimale Nutzen des Systems kann nur erreicht werden, wenn das medizinische Personal und die Untersuchungsumgebung vollständig frei von beweglichen ferromagnetischen Materialien sind. In der klinischen Routine bestehen insbesondere praktische Einschränkungen des potenziellen Nutzens für liegende Patienten. Empfehlung für die Praxis Ein Ganzkörperferrodetektorsystem kann die Patientenaufklärung und das MRT-Sicherheitstraining nicht ersetzen, jedoch sinnvoll ergänzen. Clinical/methodical issue In spite of technical and organizational measures, ferromagnetic objects still find their way into the magnetic resonance imaging (MRI) room and can cause severe injuries. Standard radiological methods A detailed patient education and MRI safety training for personnel are necessary to avoid MRI incidents with ferromagnetic objects. Methodical innovations Whole body ferromagnetic detection systems should increase patient safety and minimize risks for personnel and MRI equipment in the clinical routine. Performance In a clinical MRI setting, a screener system used for outpatients and inpatients (n = 400) identified unknown ferrous objects in 2 % of the cases. In two of these cases patients were found to be in possession of unknown foreign ferrous objects. Furthermore, a door guard system only used for outpatients (n = 2500) detected unknown ferromagnetic objects in 0.3 % of the cases. Achievements The number of ferrous objects that are unknowingly brought into the scanner room can be reduced with a whole body ferromagnetic detection system. For an optimal benefit of the system a ferrous-free environment and perfectly ferrous-free clothing for the medical personnel are necessary. In the clinical routine, the benefit of the system is limited particularly for immobile patients who have to remain in a horizontal position. Practical recommendations A whole body ferromagnetic detection system can complement but not replace patient education and MRI safety training.