Paulo Márcio Pitrez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Paulo Márcio Pitrez has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
A A da Cunha
Infant Center, Institute of Biomedical Research, Instituto de Pesquisas Biomedicas, Lab. 13, Pontifical Catholic University of Rio Grande do Sul, Av. Ipiranga, 6690, 2º floor, ZIP: 90610-000, Porto Alegre-RS, Brazil
1 shared publication- Aline Andrea da Cunha
Laboratory of Pediatric Respirology, Infant Center, Institute of Biomedical Research, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Brazil
1 shared publication - Cristian Roncada
Centro Infant, Biomedical Research Institute, Pontifícia Universidade Católica do Rio Grande (PUCRS), Porto Alegre, Brazil
1 shared publication - Henrique Takachi Moriya
Biomedical Engineering Laboratory, Escola Politécnica, University of Sao Paulo, Sao Paulo, Brazil
1 shared publication M H M Vargas
Infant Center, Institute of Biomedical Research, Instituto de Pesquisas Biomedicas, Lab. 13, Pontifical Catholic University of Rio Grande do Sul, Av. Ipiranga, 6690, 2º floor, ZIP: 90610-000, Porto Alegre-RS, Brazil
1 shared publication- Maria A. Oliveira
Departament of Pharmacology, Institute of Biomedical Sciences, Universidade de São Paulo, São Paulo 05508-000, Brazil
1 shared publication
Latest Publications
- 4 May 2017
- Published by IOP Publishing in Physiological Measurement
- Vol. 38 (6) , 992-1005
Input respiratory impedance in mice: comparison between the flow-based and the wavetube method to perform the forced oscillation technique
Objective and approach: In this study, we estimated the constant phase model (CPM) parameters from the respiratory impedance of male BALB/c mice by performing the forced oscillation technique (FOT) in a control group (n = 8) and in a murine model of asthma (OVA) (n = 10). Then, we compared the results obtained by two different methods, using a commercial equipment (flexiVent-flexiWare 7.X; SCIREQ, Montreal, Canada) (FXV) and a wavetube method equipment (Sly et al 2003 J. Appl. Physiol. 94 1460–6) (WVT). We believe that the results from different methods may not be comparable. First, we compared the results performing a two-way analysis of variance (ANOVA) for the resistance, elastance and tissue damping. Main results: We found statistically significant differences in all CPM parameters, except for resistance, when comparing Control and OVA groups. When comparing devices, we found statistically significant differences in resistance, while differences in elastance were not observed. For tissue damping, the results from WVT were observed to be higher than those from FXV. Finally, when comparing the relative variation between the CPM parameters of the Control and OVA groups in both devices, no significant differences were observed for all parameters. Significance: We then conclude that this assessment can compensate the effect of using different cannulas. Furthermore, tissue damping differences between groups can be compensated, since bronchoconstrictors were not used. Therefore, we believe that relative variations in the results between groups can be a comparing parameter when using different equipment without bronchoconstrictor administration.
- 4 May 2017
- Published by IOP Publishing in Physiological Measurement
- Vol. 38 (6) , 992-1005
Input respiratory impedance in mice: comparison between the flow-based and the wavetube method to perform the forced oscillation technique
Objective and approach: In this study, we estimated the constant phase model (CPM) parameters from the respiratory impedance of male BALB/c mice by performing the forced oscillation technique (FOT) in a control group (n = 8) and in a murine model of asthma (OVA) (n = 10). Then, we compared the results obtained by two different methods, using a commercial equipment (flexiVent-flexiWare 7.X; SCIREQ, Montreal, Canada) (FXV) and a wavetube method equipment (Sly et al 2003 J. Appl. Physiol. 94 1460–6) (WVT). We believe that the results from different methods may not be comparable. First, we compared the results performing a two-way analysis of variance (ANOVA) for the resistance, elastance and tissue damping. Main results: We found statistically significant differences in all CPM parameters, except for resistance, when comparing Control and OVA groups. When comparing devices, we found statistically significant differences in resistance, while differences in elastance were not observed. For tissue damping, the results from WVT were observed to be higher than those from FXV. Finally, when comparing the relative variation between the CPM parameters of the Control and OVA groups in both devices, no significant differences were observed for all parameters. Significance: We then conclude that this assessment can compensate the effect of using different cannulas. Furthermore, tissue damping differences between groups can be compensated, since bronchoconstrictors were not used. Therefore, we believe that relative variations in the results between groups can be a comparing parameter when using different equipment without bronchoconstrictor administration.
- 1 January 2017
- Published by Tikinet Edicao Ltda. - EPP in Clinical and Biomedical Research
- Vol. 37 (2) , 132-139
REVISÃO SISTEMÁTICA SOBRE MODELOS EXPERIMENTAIS DE ASMA AGUDA E CRÔNICA INDUZIDOS COM EXTRATO DE ÁCARO DA POEIRA DOMÉSTICA
- 1 January 2017
- Published by Tikinet Edicao Ltda. - EPP in Clinical and Biomedical Research
- Vol. 37 (2) , 132-139
REVISÃO SISTEMÁTICA SOBRE MODELOS EXPERIMENTAIS DE ASMA AGUDA E CRÔNICA INDUZIDOS COM EXTRATO DE ÁCARO DA POEIRA DOMÉSTICA