Matej Cenký
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Matej Cenký has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
- Jozef Bendík
Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 81 219 Bratislava, Slovakia
17 shared publications - Peter Janiga
Department of Power and Applied Electrical Engineering, Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 841 04 Bratislava, Slovakia
9 shared publications - Anton Beláň
Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 81 219 Bratislava, Slovakia
7 shared publications - Žaneta Eleschová
Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 81 219 Bratislava, Slovakia
7 shared publications - Boris Cintula
Faculty of Electrical Engineering and Information Technology, Slovak University of Technology in Bratislava, Ilkovičova 3, 81 219 Bratislava, Slovakia
5 shared publications Žaneta Eleschová
Slovak University of Technology in Bratislava, Institute of Power and Applied Electrical Engineering, Bratislava, Slovakia
3 shared publications
Latest Publications
- Open Access
- 14 October 2026
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 32
From observed deployment to national potential: A revealed-siting assessment of agrivoltaics in Slovakia
- 14 October 2026
- Published by Elsevier in Energy Conversion and Management: X
- Vol. 32
Open AccessFrom observed deployment to national potential: A revealed-siting assessment of agrivoltaics in Slovakia
- Open Access
- 3 August 2026
- Published by MDPI AG in Urban Science
- Vol. 10 (8) , 445
From Hourly Irradiance Discrepancy to Day-Ahead Photovoltaic Energy: Evaluating Free Weather APIs for Urban Energy Management
Freely accessible weather APIs are an attractive input for photovoltaic (PV) power prediction, yet how their reference-based error carries through—under temporal aggregation—into day-ahead PV energy is rarely quantified before model development. This study audits eight freely accessible weather-data services—seven forecast services and the Meteostat observational archive—and finds that, for the endpoints, subscription tiers, and collection period evaluated here, only two of the forecast services expose hourly global horizontal irradiance (GHI), while a third advertised irradiance field returns empty—itself a material result for municipal integrators. The two irradiance-capable services are propagated through a common physical PV model of the 548 kWp east–west rooftop plant being built on a university campus in Bratislava, Slovakia, against independent references (CAMS irradiance; NASA POWER temperature and wind). Throughout, “error” denotes discrepancy against the reference, not measurement truth. Over a common 62-day spring–summer window, the day-ahead daily-energy mean absolute error (MAE, relative to mean reference daily energy) is 10–11% for both sources; Open-Meteo’s winter-inclusive own window raises its value to about 13%. On the matched window, Open-Meteo has the lower hourly GHI RMSE (121 vs. 128 W·m−2), yet this advantage does not carry through to day-ahead energy—the point-estimate ordering even changes—and neither matched-window difference is statistically resolved. Because daily aggregation rewards low bias over low scatter, this ordering change is already present in daily GHI energy—before the PV conversion—so hourly irradiance accuracy alone does not determine day-ahead energy. Propagated input-data auditing is therefore an advisable step before ML-based PV forecasting and day-ahead scheduling of urban distributed PV.
- 3 August 2026
- Published by MDPI AG in Urban Science
- Vol. 10 (8) , 445
Open AccessFrom Hourly Irradiance Discrepancy to Day-Ahead Photovoltaic Energy: Evaluating Free Weather APIs for Urban Energy Management
Freely accessible weather APIs are an attractive input for photovoltaic (PV) power prediction, yet how their reference-based error carries through—under temporal aggregation—into day-ahead PV energy is rarely quantified before model development. This study audits eight freely accessible weather-data services—seven forecast services and the Meteostat observational archive—and finds that, for the endpoints, subscription tiers, and collection period evaluated here, only two of the forecast services expose hourly global horizontal irradiance (GHI), while a third advertised irradiance field returns empty—itself a material result for municipal integrators. The two irradiance-capable services are propagated through a common physical PV model of the 548 kWp east–west rooftop plant being built on a university campus in Bratislava, Slovakia, against independent references (CAMS irradiance; NASA POWER temperature and wind). Throughout, “error” denotes discrepancy against the reference, not measurement truth. Over a common 62-day spring–summer window, the day-ahead daily-energy mean absolute error (MAE, relative to mean reference daily energy) is 10–11% for both sources; Open-Meteo’s winter-inclusive own window raises its value to about 13%. On the matched window, Open-Meteo has the lower hourly GHI RMSE (121 vs. 128 W·m−2), yet this advantage does not carry through to day-ahead energy—the point-estimate ordering even changes—and neither matched-window difference is statistically resolved. Because daily aggregation rewards low bias over low scatter, this ordering change is already present in daily GHI energy—before the PV conversion—so hourly irradiance accuracy alone does not determine day-ahead energy. Propagated input-data auditing is therefore an advisable step before ML-based PV forecasting and day-ahead scheduling of urban distributed PV.
- Open Access
An Invertible Extended Sequence Transform for Untransposed Three-Phase Overhead Lines
The classical Fortescue symmetrical-component transform remains fully invertible as a similarity transform when the complete sequence-domain matrix is retained. In practice, however, untransposed three-phase overhead lines are often summarized by the diagonal sequence quantities and , while the asymmetry appears through coupled off-diagonal terms that are less convenient for compact parameterization and measurement-based interpretation. This paper presents an Extended Sequence Transform that reorganizes the six independent entries of the phase-domain impedance matrix into six structured parameters by means of a lossless, invertible linear mapping. The first two parameters are identical to the classical zero- and positive-sequence impedances, which preserves backward compatibility. The remaining four parameters isolate asymmetry information in a form from which all entries of the classical sequence matrix can be recovered exactly, and from which the full phase-domain matrix is reconstructed to machine precision. The proposed representation does not diagonalize an untransposed line; rather, it provides a compact and explicit six-scalar parameterization that separates the classical sequence pair from four asymmetry descriptors. Numerical validation on a 50 km untransposed overhead line confirms exact round-trip reconstruction and exact agreement of the unbalance factors obtained from the classical and extended representations. A stochastic perturbation study further shows that round-trip reconstruction remains at numerical precision and that, within the tested perturbation grid, the factor is more sensitive than . Line-constant calculations performed in OpenDSS for two typical 400 kV tower geometries link the four asymmetry parameters to specific geometric features, a worked offline measurement example recovers them from simulated three-phase terminal tests, and a distributed-model study confirms that the lumped-parameter description of the asymmetry remains accurate to within about 0.6% up to 150 km.Open AccessAn Invertible Extended Sequence Transform for Untransposed Three-Phase Overhead Lines
The classical Fortescue symmetrical-component transform remains fully invertible as a similarity transform when the complete sequence-domain matrix is retained. In practice, however, untransposed three-phase overhead lines are often summarized by the diagonal sequence quantities and , while the asymmetry appears through coupled off-diagonal terms that are less convenient for compact parameterization and measurement-based interpretation. This paper presents an Extended Sequence Transform that reorganizes the six independent entries of the phase-domain impedance matrix into six structured parameters by means of a lossless, invertible linear mapping. The first two parameters are identical to the classical zero- and positive-sequence impedances, which preserves backward compatibility. The remaining four parameters isolate asymmetry information in a form from which all entries of the classical sequence matrix can be recovered exactly, and from which the full phase-domain matrix is reconstructed to machine precision. The proposed representation does not diagonalize an untransposed line; rather, it provides a compact and explicit six-scalar parameterization that separates the classical sequence pair from four asymmetry descriptors. Numerical validation on a 50 km untransposed overhead line confirms exact round-trip reconstruction and exact agreement of the unbalance factors obtained from the classical and extended representations. A stochastic perturbation study further shows that round-trip reconstruction remains at numerical precision and that, within the tested perturbation grid, the factor is more sensitive than . Line-constant calculations performed in OpenDSS for two typical 400 kV tower geometries link the four asymmetry parameters to specific geometric features, a worked offline measurement example recovers them from simulated three-phase terminal tests, and a distributed-model study confirms that the lumped-parameter description of the asymmetry remains accurate to within about 0.6% up to 150 km. - Open Access
- 1 May 2026
- Published by MDPI AG in Electricity
- Vol. 7 (2) , 39
Determination of Ground Clearance for EHV 400 kV Overhead Power Lines Based on Electromagnetic Field Limits
The planning and design of Extra-High Voltage (EHV) overhead power lines require strict adherence to electromagnetic field exposure limits to ensure public safety. This paper presents a comprehensive analysis of the minimum ground clearance required for standard 400 kV transmission towers to comply with international safety guidelines. A review of legislative frameworks across 37 countries indicates a widespread consensus on limiting values of 5 kV/m for the electric field and 100 T for magnetic flux density. Using analytical methods, the electric and magnetic fields were calculated for four common tower geometries (Cat, Portal, Danube, and Barrel) under varying ground clearances and phase configurations. The results demonstrate that the magnetic flux density is not a limiting factor, as it remains well below safety thresholds even at standard technical clearances. Conversely, the electric field intensity proves to be the critical design constraint, often requiring clearances significantly higher than those dictated by insulation coordination. The study identifies that optimizing the phase sequence in double-circuit towers can reduce the required ground clearance by up to 28%, offering a cost-effective mitigation strategy. These findings provide power line designers with essential decision-making data for the preliminary design phase, enabling the optimization of tower geometry and phase arrangement without the need for computationally intensive simulations.- 1 May 2026
- Published by MDPI AG in Electricity
- Vol. 7 (2) , 39
Open AccessDetermination of Ground Clearance for EHV 400 kV Overhead Power Lines Based on Electromagnetic Field Limits
The planning and design of Extra-High Voltage (EHV) overhead power lines require strict adherence to electromagnetic field exposure limits to ensure public safety. This paper presents a comprehensive analysis of the minimum ground clearance required for standard 400 kV transmission towers to comply with international safety guidelines. A review of legislative frameworks across 37 countries indicates a widespread consensus on limiting values of 5 kV/m for the electric field and 100 T for magnetic flux density. Using analytical methods, the electric and magnetic fields were calculated for four common tower geometries (Cat, Portal, Danube, and Barrel) under varying ground clearances and phase configurations. The results demonstrate that the magnetic flux density is not a limiting factor, as it remains well below safety thresholds even at standard technical clearances. Conversely, the electric field intensity proves to be the critical design constraint, often requiring clearances significantly higher than those dictated by insulation coordination. The study identifies that optimizing the phase sequence in double-circuit towers can reduce the required ground clearance by up to 28%, offering a cost-effective mitigation strategy. These findings provide power line designers with essential decision-making data for the preliminary design phase, enabling the optimization of tower geometry and phase arrangement without the need for computationally intensive simulations. - Open Access
- 28 March 2026
- Published by Elsevier in SSRN Electronic Journal
An Invertible Extended Sequence Transform for Untransposed Three-Phase Overhead Lines
The classical Fortescue symmetrical-component transform cannot be inverted to recover the full phase-domain impedance matrix of an untransposed three-phase overhead line. This paper presents the Extended Sequence Transform that is a lossless, invertible 6x6 linear mapping from the six independent entries of the phase-domain impedance matrix to six extended sequence parameters. The first two parameters are identical to the classical zero- and positive-sequence impedances, ensuring full backward compatibility. The four new asymmetry parameters encode the off-diagonal coupling structure without loss of information, and the exact inverse recovers all six phase-domain entries to machine precision. All entries of the classical sequence matrix are expressible as linear combinations of the extended parameters, and the standard inductive unbalance factors are completely determined by the four asymmetry parameters. A structural property of the transform is that five of the six parameters are immune to uniform common-mode perturbations of the phase-domain matrix, independently of line geometry. Numerical validation on a 50~km untransposed overhead line confirms lossless round-trip reconstruction and exact agreement of the unbalance factors via both routes.
- 28 March 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessAn Invertible Extended Sequence Transform for Untransposed Three-Phase Overhead Lines
The classical Fortescue symmetrical-component transform cannot be inverted to recover the full phase-domain impedance matrix of an untransposed three-phase overhead line. This paper presents the Extended Sequence Transform that is a lossless, invertible 6x6 linear mapping from the six independent entries of the phase-domain impedance matrix to six extended sequence parameters. The first two parameters are identical to the classical zero- and positive-sequence impedances, ensuring full backward compatibility. The four new asymmetry parameters encode the off-diagonal coupling structure without loss of information, and the exact inverse recovers all six phase-domain entries to machine precision. All entries of the classical sequence matrix are expressible as linear combinations of the extended parameters, and the standard inductive unbalance factors are completely determined by the four asymmetry parameters. A structural property of the transform is that five of the six parameters are immune to uniform common-mode perturbations of the phase-domain matrix, independently of line geometry. Numerical validation on a 50~km untransposed overhead line confirms lossless round-trip reconstruction and exact agreement of the unbalance factors via both routes.
- Open Access
- 12 December 2024
- Published by MDPI AG in Smart Cities
- Vol. 7 (6) , 3962-3982
Urban-Scale Rooftop Photovoltaic Potential Estimation Using Open-Source Software and Public GIS Datasets
This paper aims to effectively estimate urban-scale rooftop photovoltaic potential using strictly open-source software and publicly available GIS data. This approach is often neglected; however, its importance is significant regarding technology transfer and general commercial or academic ease of use. A complete methodology is introduced, including the building shadow analysis. Although many papers are published in similar areas, very few reveal the specific steps and functions in the software used, or the computational core of some part of the estimation is a “black box” of a commercial service. Detailed irradiation parameters can be obtained using the proposed methodologies, and the maximum photovoltaic (PV) power output in the area can be estimated. The great advantage of this model is its scalability and the easy way of modifying every computational parameter. The results and limitations of the proposed methodology are discussed, and further development is suggested. The presented model is based on a sample location in Bratislava, Slovakia, with an area of circa 2.5 km2.
- 12 December 2024
- Published by MDPI AG in Smart Cities
- Vol. 7 (6) , 3962-3982
Open AccessUrban-Scale Rooftop Photovoltaic Potential Estimation Using Open-Source Software and Public GIS Datasets
This paper aims to effectively estimate urban-scale rooftop photovoltaic potential using strictly open-source software and publicly available GIS data. This approach is often neglected; however, its importance is significant regarding technology transfer and general commercial or academic ease of use. A complete methodology is introduced, including the building shadow analysis. Although many papers are published in similar areas, very few reveal the specific steps and functions in the software used, or the computational core of some part of the estimation is a “black box” of a commercial service. Detailed irradiation parameters can be obtained using the proposed methodologies, and the maximum photovoltaic (PV) power output in the area can be estimated. The great advantage of this model is its scalability and the easy way of modifying every computational parameter. The results and limitations of the proposed methodology are discussed, and further development is suggested. The presented model is based on a sample location in Bratislava, Slovakia, with an area of circa 2.5 km2.
- Open Access
The Influence of Harmonic Content on the RMS Value of Electromagnetic Fields Emitted by Overhead Power Lines
This paper investigates the influence of harmonic content on the root mean square value of electromagnetic fields emitted by overhead power lines. The paper presents a methodology to assess the intensity of electric field and magnetic flux density, incorporating both fundamental frequencies and harmonics. The results of our calculations indicate that harmonic distortion in current waveforms can significantly increase the RMS value of magnetic flux density but its effect on electric field intensity is minimal. Additionally, our findings highlight a potential increase in induced voltages on buried or overhead steel pipelines in the vicinity of OPLs, which could pose risks such as pipeline damage and increased corrosion. This underscores the importance of considering harmonic content in EMF exposure evaluations to address both health risks and potential infrastructure impacts comprehensively. Effective harmonic management and rigorous infrastructure monitoring are essential to prevent potential hazards and ensure the reliability of protective systems.
Open AccessThe Influence of Harmonic Content on the RMS Value of Electromagnetic Fields Emitted by Overhead Power Lines
This paper investigates the influence of harmonic content on the root mean square value of electromagnetic fields emitted by overhead power lines. The paper presents a methodology to assess the intensity of electric field and magnetic flux density, incorporating both fundamental frequencies and harmonics. The results of our calculations indicate that harmonic distortion in current waveforms can significantly increase the RMS value of magnetic flux density but its effect on electric field intensity is minimal. Additionally, our findings highlight a potential increase in induced voltages on buried or overhead steel pipelines in the vicinity of OPLs, which could pose risks such as pipeline damage and increased corrosion. This underscores the importance of considering harmonic content in EMF exposure evaluations to address both health risks and potential infrastructure impacts comprehensively. Effective harmonic management and rigorous infrastructure monitoring are essential to prevent potential hazards and ensure the reliability of protective systems.
- Open Access
- 19 August 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 64-69
Analytical solution of conductor tensile force in asymmetrical spans used in overhead power lines and substations with influence of tension insulators
Introduction. Designing electrical substations involves analyzing the horizontal tensile force in flexible tension conductors under varying temperatures. These temperature changes affect the conductor’s length and forces. Problem. Existing methods for calculating horizontal tensile force in conductors often focus on symmetric spans or require complex finite element modeling (FEM), which is impractical for routine substation design. Asymmetric spans with tension insulators present a more complex challenge that current solutions do not adequately address. Purpose. Universal analytical solution and algorithm for calculating the horizontal tensile forces in conductors in asymmetric spans with tension insulators used in power substations or short overhead power line spans. The solution is designed to be easily implementable in software without requiring complex tools or extensive FEM. Methodology. The methodology involves deriving an analytical solution based on the catenary curve formed by the conductor between attachment points at different heights. The analysis includes calculating the conductor’s length for a given tensile force and using a state change equation to determine forces under new temperature conditions. Validation is performed using FEM calculations. Results. The proposed solution was validated against FEM models with varying height differences (5 m and 15 m) and conductor temperatures (–30 °C, –5 °C, +80 °C). The results showed a minimal error (less than 0.15 %) between the analytical solution and FEM results, demonstrating high accuracy. Originality. This paper presents a novel analytical solution to the problem of calculating tensile forces in asymmetric spans with tension insulators. Unlike existing methods, our solution is straightforward and easily implementable in any programming language. Practical value. The solution is practical for routine design tasks in electrical substations or short overhead power lines. Especially in power substations, accurate tensile forces are needed not only for mechanical design and sag calculations but also for calculating the dynamic effects of short-circuit currents. References 23, tables 4, figures 3.
- 19 August 2024
- Published by National Technical University Kharkiv Polytechnic Institute in Electrical Engineering & Electromechanics
- No. 5,p. 64-69
Open AccessAnalytical solution of conductor tensile force in asymmetrical spans used in overhead power lines and substations with influence of tension insulators
Introduction. Designing electrical substations involves analyzing the horizontal tensile force in flexible tension conductors under varying temperatures. These temperature changes affect the conductor’s length and forces. Problem. Existing methods for calculating horizontal tensile force in conductors often focus on symmetric spans or require complex finite element modeling (FEM), which is impractical for routine substation design. Asymmetric spans with tension insulators present a more complex challenge that current solutions do not adequately address. Purpose. Universal analytical solution and algorithm for calculating the horizontal tensile forces in conductors in asymmetric spans with tension insulators used in power substations or short overhead power line spans. The solution is designed to be easily implementable in software without requiring complex tools or extensive FEM. Methodology. The methodology involves deriving an analytical solution based on the catenary curve formed by the conductor between attachment points at different heights. The analysis includes calculating the conductor’s length for a given tensile force and using a state change equation to determine forces under new temperature conditions. Validation is performed using FEM calculations. Results. The proposed solution was validated against FEM models with varying height differences (5 m and 15 m) and conductor temperatures (–30 °C, –5 °C, +80 °C). The results showed a minimal error (less than 0.15 %) between the analytical solution and FEM results, demonstrating high accuracy. Originality. This paper presents a novel analytical solution to the problem of calculating tensile forces in asymmetric spans with tension insulators. Unlike existing methods, our solution is straightforward and easily implementable in any programming language. Practical value. The solution is practical for routine design tasks in electrical substations or short overhead power lines. Especially in power substations, accurate tensile forces are needed not only for mechanical design and sag calculations but also for calculating the dynamic effects of short-circuit currents. References 23, tables 4, figures 3.
- Open Access
- 16 September 2023
- Published by Elsevier in Data in Brief
- Vol. 50, 109588
Dataset of 15-minute values of active and reactive power consumption of 1000 households during single year
- 16 September 2023
- Published by Elsevier in Data in Brief
- Vol. 50, 109588
Open AccessDataset of 15-minute values of active and reactive power consumption of 1000 households during single year