An Invertible Extended Sequence Transform for Untransposed Three-Phase Overhead Lines
Open Access
Abstract
The classical Fortescue symmetrical-component transform remains fully invertible as a similarity transform when the complete sequence-domain matrix is retained. In practice, however, untransposed three-phase overhead lines are often summarized by the diagonal sequence quantities and , while the asymmetry appears through coupled off-diagonal terms that are less convenient for compact parameterization and measurement-based interpretation. This paper presents an Extended Sequence Transform that reorganizes the six independent entries of the phase-domain impedance matrix into six structured parameters by means of a lossless, invertible linear mapping. The first two parameters are identical to the classical zero- and positive-sequence impedances, which preserves backward compatibility. The remaining four parameters isolate asymmetry information in a form from which all entries of the classical sequence matrix can be recovered exactly, and from which the full phase-domain matrix is reconstructed to machine precision. The proposed representation does not diagonalize an untransposed line; rather, it provides a compact and explicit six-scalar parameterization that separates the classical sequence pair from four asymmetry descriptors. Numerical validation on a 50 km untransposed overhead line confirms exact round-trip reconstruction and exact agreement of the unbalance factors obtained from the classical and extended representations. A stochastic perturbation study further shows that round-trip reconstruction remains at numerical precision and that, within the tested perturbation grid, the factor is more sensitive than . Line-constant calculations performed in OpenDSS for two typical 400 kV tower geometries link the four asymmetry parameters to specific geometric features, a worked offline measurement example recovers them from simulated three-phase terminal tests, and a distributed-model study confirms that the lumped-parameter description of the asymmetry remains accurate to within about 0.6% up to 150 km.
Keywords
Funding Information
- The Scientific Grant Agency (1/0380/26)
This publication has 14 references indexed in Scilit:
- Clarke Transform Based Fast Assessment of Switching Overvoltages in an MV Distribution NetworkElectric Power Systems Research, 2022
- Parameter Estimation of Three-Phase Untransposed Short Transmission Lines From Synchrophasor MeasurementsIEEE Transactions on Instrumentation and Measurement, 2020
- Symmetrical components analysis of faulted three-phase networks containing voltage and current sources2019
- Analyzing faulted transmission lines: Phase components as an alternative to symmetrical components2018
- Modal decoupling of overhead transmission lines using real and constant matrices: Influence of the line lengthInternational Journal of Electrical Power & Energy Systems, 2017
- A Method for Accurate Transmission Line Impedance Parameter EstimationIEEE Transactions on Instrumentation and Measurement, 2016
- Overhead Power Lines2003
- Evaluation of modal transformation matrices for overhead transmission lines and underground cables by optimization methodIEEE Transactions on Power Delivery, 2002
- On the modal analysis of asymmetrical three-phase transmission lines using standard transformation matricesIEEE Transactions on Power Delivery, 1997
- Method of Symmetrical Co-Ordinates Applied to the Solution of Polyphase NetworksTransactions of the American Institute of Electrical Engineers, 1918