LALahsen Assoufid

Lahsen Assoufid

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lahsen Assoufid has a total of 56 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Reducing heat load density with asymmetric and inclined double-crystal monochromators: principles and requirements revisited

    by XianRong Huang, Lahsen Assoufid, Albert T. Macrander

    Asymmetric double-crystal monochromators (aDCMs) and inclined DCMs (iDCMs) can significantly expand the X-ray beam footprint and consequently reduce the heat load density and gradient. Based on rigorous dynamical theory calculations, the major principles and properties of aDCMs and iDCMs are presented to guide their design and development, particularly for fourth-generation synchrotrons. In addition to the large beam footprint, aDCMs have very large bandwidths (up to ∼10 eV) and angular acceptance, but the narrow angular acceptance of the second crystal requires precise control of the relative orientations and strains. Based on Fourier coupled-wave diffraction theory calculations, it is rigorously proved that the iDCM has almost the same properties as the conventional symmetric DCM, including the efficiency, angular acceptance, bandwidth, tuning energy range and sensitivity to misalignment. The exception is that, for the extremely inclined geometry that can achieve very large footprint expansion, the iDCM has (beneficially) a larger bandwidth and wider angular acceptance. Inclined diffraction has the `rho-kick effect' that can be cancelled by the second reflection of the iDCM (even with misalignment), except that inhomogeneous strains may cause non-uniform rho-kick angles. At present, fabrication/mounting-induced strains pose low risk since they can be controlled to <0.5 µrad over large areas. The only uncertain challenge is the thermally induced strains, yet it is estimated that these strains are naturally lowered by the large footprint and may be further mitigated by optimized cryogenic cooling to the 1–2 µrad level. Overall, aDCMs and iDCMs have more stringent requirements than normal DCMs, but they are feasible schemes in practice.


  • Open Access

    X-ray optics for the cavity-based X-ray free-electron laser

    by Peifan Liu, Paresh Pradhan, Xianbo Shi, Deming Shu, Keshab Kauchha, Zhi Qiao, Kenji Tamasaku, Taito Osaka, Diling Zhu, Takahiro Sato, et al.

    A cavity-based X-ray free-electron laser (CBXFEL) is a possible future direction in the development of fully coherent X-ray sources. CBXFELs consist of a low-emittance electron source, a magnet system with several undulators and chicanes, and an X-ray cavity. The X-ray cavity stores and circulates X-ray pulses for repeated FEL interactions with electron pulses until the FEL reaches saturation. CBXFEL cavities require low-loss wavefront-preserving optical components: near-100%-reflectivity X-ray diamond Bragg-reflecting crystals, outcoupling devices such as thin diamond membranes or X-ray gratings, and aberration-free focusing elements. In the framework of the collaborative CBXFEL research and development project of Argonne National Laboratory, SLAC National Accelerator Laboratory and SPring-8, we report here the design, manufacturing and characterization of X-ray optical components for the CBXFEL cavity, which include high-reflectivity diamond crystal mirrors, a diamond drumhead crystal with thin membranes, beryllium refractive lenses and channel-cut Si monochromators. All the designed optical components have been fully characterized at the Advanced Photon Source to demonstrate their suitability for the CBXFEL cavity application.


  • Open Access

    Increased spatial coherence length from an asymmetric crystal reflection at grazing exit

    by Albert Macrander, Xianbo Shi, Walan Grizzoli, Xianrong Huang, Nino Pereira, Michael Wojcik, Lahsen Assoufid

    Coherent X-ray imaging is an active field at synchrotron sources. The images rely on the available coherent flux over a limited field of view. At many synchrotron beamlines a double-crystal monochromator (DCM) is employed in a standard nondispersive arrangement. For coherent diffraction imaging it is advantageous to increase the available field of view by increasing the spatial coherence length (SCL) of a beam exiting such a DCM. Here, Talbot interferometry data together with ray-tracing simulations for a (+ − − +) four-reflection experimental arrangement are presented, wherein the first two reflections are in the DCM and the final fourth reflection is asymmetric at grazing exit. Analyses of the interferometry data combined with the simulations show that compared with the beam exiting the DCM a gain of 76% in the SCL was achieved, albeit with a factor of 20 reduction in flux density, which may not be a severe penalty at a synchrotron beamline. Previous efforts reported in the literature to increase the SCL that employed asymmetric crystal diffraction at grazing incidence are also discussed. A much reduced SCL is found presently in simulations wherein the same asymmetric crystal is set for grazing incidence instead of grazing exit. In addition, the present study is compared and contrasted with two other means of increasing the SCL. These are (i) focusing the beam onto an aperture to act as a secondary source, and (ii) allowing the beam to propagate in vacuum an additional distance along the beamline.


  • Open Access

    At-wavelength characterization of X-ray wavefronts in Bragg diffraction from crystals

    by Xianbo Shi, Zhi Qiao, Paresh Pradhan, Peifan Liu, Lahsen Assoufid, Kwang-Je Kim, Yuri Shvyd'KO

    The advent of next-generation synchrotron radiation sources and X-ray free-electron lasers calls for high-quality Bragg-diffraction crystal optics to preserve the X-ray beam coherence and wavefront. This requirement brings new challenges in characterizing crystals in Bragg diffraction in terms of Bragg-plane height errors and wavefront phase distortions. Here, a quantitative methodology to characterize crystal optics using a state-of-the-art at-wavelength wavefront sensing technique and statistical analysis is proposed. The method was tested at the 1-BM-B optics testing beamline at the Advanced Photon Source for measuring silicon and diamond crystals in a self-referencing single-crystal mode and an absolute double-crystal mode. The phase error sensitivity of the technique is demonstrated to be at the λ/100 level required by most applications, such as the characterization of diamond crystals for cavity-based X-ray free-electron lasers.


  • Open Access

    Data-driven modeling and control of an X-ray bimorph adaptive mirror

    by Gautam Gunjala, Antoine Wojdyla, Kenneth A. Goldberg, Zhi Qiao, Xianbo Shi, Lahsen Assoufid, Laura Waller

    Adaptive X-ray mirrors are being adopted on high-coherent-flux synchrotron and X-ray free-electron laser beamlines where dynamic phase control and aberration compensation are necessary to preserve wavefront quality from source to sample, yet challenging to achieve. Additional difficulties arise from the inability to continuously probe the wavefront in this context, which demands methods of control that require little to no feedback. In this work, a data-driven approach to the control of adaptive X-ray optics with piezo-bimorph actuators is demonstrated. This approach approximates the non-linear system dynamics with a discrete-time model using random mirror shapes and interferometric measurements as training data. For mirrors of this type, prior states and voltage inputs affect the shape-change trajectory, and therefore must be included in the model. Without the need for assumed physical models of the mirror's behavior, the generality of the neural network structure accommodates drift, creep and hysteresis, and enables a control algorithm that achieves shape control and stability below 2 nm RMS. Using a prototype mirror and ex situ metrology, it is shown that the accuracy of our trained model enables open-loop shape control across a diverse set of states and that the control algorithm achieves shape error magnitudes that fall within diffraction-limited performance.


  • Quantitative analysis of dislocations in 4H-SiC wafers using synchrotron X-ray topography with ultra-high angular resolution

    by Hongyu Peng, Zeyu Chen, Yafei Liu, Balaji Raghothamachar, Xianrong Huang, Lahsen Assoufid, Michael Dudley

    Utilization of an Si(331) beam conditioner together with an Si(111) double-crystal monochromator (DCM) enables the angular resolution of synchrotron X-ray topography to be increased by an order of magnitude compared with grazing-incidence topography or back-reflection topography conducted with the DCM alone. This improved technique with extremely small beam divergence is referred to as synchrotron X-ray plane-wave topography (SXPWT). This study demonstrates that the rocking curve width of 4H-SiC 0008 in PWT is only 2.5′′ and thus the lattice distortion at the scale of 1′′ will significantly affect the diffracted intensity. This work reports the ultra-high angular resolution in SXPWT which enables detailed probing of the lattice distortion outside the dislocation core in 4H-SiC, where the sign of the Burgers vector can be readily determined through comparison with ray-tracing simulations.


  • Open Access

    Diffuse X-ray scattering from polished silicon: application of the distorted wave Born approximation

    by Albert Macrander, Lahsen Assoufid, Suresh Narayanan, Ruben Khachatryan

    Measured diffuse X-ray scattering data for a `smooth' as well as for a `rough' silicon sample were fit to theoretical expressions within the distorted wave Born approximation (DWBA). Data for the power spectral density (PSD) for both samples were also obtained by means of atomic force microscopy and optical interferometry. The Fourier transforms of trial correlation functions were fit to the PSD data and then applied to the DWBA formalism. The net correlation functions needed to fit the PSD data for each sample comprised the sum of two terms with different cutoff lengths and different self-affine fractal exponents. At zero distance these correlation functions added up to yield net values of σ2 = (2)2 and (71)2 Å2 for the smooth and rough samples, respectively. X-ray scattering data were obtained at beamline 1-BM of the Advanced Photon Source. Data and fits at values of q z = 0.05 and 0.10 Å−1 for the smooth sample are reported. Good fits for the smooth sample were obtained at both q z values simultaneously, that is, identical fitting parameters were applied at both values of q z . The smooth sample also exhibited weak Yoneda wings and a clear distinction between the strong specular scattering and the weak diffuse scattering. Data for the rough sample were qualitatively different and exhibited very weak scattering at the specular condition in contrast to extremely large Yoneda wings. Fits for the rough sample are reported for q z = 0.04, 0.05, and 0.06 Å−1. Although the large Yoneda wings could be fit quite well in both position and amplitude, scattering near the specular condition could not be equally well fit by applying the same fitting parameters at all values of q z . Albeit imperfect, best-fitting results at the specular condition were obtained by invoking only diffuse scattering, that is, without including a separate theoretical expression for specular scattering.


  • Open Access

    X-ray beam monitoring and wavelength calibration using four-beam diffraction

    by XianRong Huang, Xianbo Shi, Lahsen Assoufid

    Rigorous dynamical theory calculations show that four-beam diffraction (4BD) can be activated only by a unique photon energy and a unique incidence direction. Thus, 4BD may be used to precisely calibrate X-ray photon energies and beam positions. Based on the principles that the forbidden-reflection 4BD pattern, which is typically an X-shaped cross, can be generated by instant imaging using the divergent beam from a point source without rocking the crystal, a detailed real-time high-resolution beam (and source) position monitoring scheme is illustrated for monitoring two-dimensional beam positions and directions of modern synchrotron light sources, X-ray free-electron lasers and nano-focused X-ray sources.


  • Open Access

    High-Resolution Scanning Coded-Mask-Based X-ray Multi-Contrast Imaging and Tomography

    by Zhi Qiao, Xianbo Shi, Michael Wojcik, Lahsen Assoufid

    Near-field X-ray speckle tracking has been used in phase-contrast imaging and tomography as an emerging technique, providing higher contrast images than traditional absorption radiography. Most reported methods use sandpaper or membrane filters as speckle generators and digital image cross-correlation for phase reconstruction, which has either limited resolution or requires a large number of position scanning steps. Recently, we have proposed a novel coded-mask-based multi-contrast imaging (CMMI) technique for single-shot measurement with superior performance in efficiency and resolution compared with other single-shot methods. We present here a scanning CMMI method for the ultimate imaging resolution and phase sensitivity by using a coded mask as a high-contrast speckle generator, the flexible scanning mode, the adaption of advanced maximum-likelihood optimization to scanning data, and the multi-resolution analysis. Scanning CMMI can outperform other speckle-based imaging methods, such as X-ray speckle vector tracking, providing higher quality absorption, phase, and dark-field images with fewer scanning steps. Scanning CMMI is also successfully demonstrated in multi-contrast tomography, showing great potentials in high-resolution full-field imaging applications, such as in vivo biomedical imaging.


  • Dislocation contrast on X-ray topographs under weak diffraction conditions

    by Hongyu Peng, Tuerxun Ailihumaer, Yafei Liu, Balaji Raghotharmachar, Xianrong Huang, Lahsen Assoufid, Michael Dudley

    The contrast of dislocations in 4H-SiC crystals shows distinctive features on grazing-incidence X-ray topographs for diffraction at different positions on the operative rocking curve. Ray-tracing simulations have previously been successfully applied to describe the dislocation contrast at the peak of a rocking curve.The present work shows that the dislocation images observed under weak diffraction conditions can also be simulated using the ray-tracing method. These simulations indicate that the contrast of the dislocations is dominated by orientation contrast. Analysis of the effective misorientation reveals that the dislocation contrast in weak-beam topography is more sensitive to the local lattice distortion, consequently enabling information to be obtained on the dislocation sense which cannot be obtained from the peak.