JCJakub Ceranka

Jakub Ceranka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jakub Ceranka has a total of 36 co-authors. Here are the top co-authors by number of shared publications:

  • Jef Vandemeulebroucke

    Department of Electronics and Informatics (ETRO) Vrije Universiteit Brussel Brussels Belgium

    9 shared publications
  • Frédéric Lecouvet

    Cliniques universitaires Saint Luc, Institut de Recherche Expérimentale et Clinique (IREC), Université catholique de Louvain (UCLouvain), Brussels, Belgium

    4 shared publications
  • Johan de Mey

    Universitair Ziekenhuis Brussel, Department of Radiology, Brussels, Belgium

    4 shared publications
  • Frederic E. Lecouvet

    Department of Medical Imaging, Institut de Recherche Expérimentale et Clinique (IREC), Institut du Cancer Roi Albert II, Cliniques Universitaires Saint Luc, Université Catholique de Louvain (UCL), Brussels, Belgium

    3 shared publications
  • Joris Wuts

    Vrije Universiteit Brussel, Department of Electronics and Informatics, Pleinlaan 2, Brussels, 1050, Belgium

    3 shared publications
  • Nicolas Michoux

    Cliniques universitaires Saint Luc, Institut de Recherche Expérimentale et Clinique (IREC), Université catholique de Louvain (UCLouvain), Brussels, Belgium

    3 shared publications

Latest Publications

  • Open Access

    Clinically aligned whole-body MRI segmentation of skeletal metastases via Supervised Anatomical Pretraining

    by Joris Wuts, Jakub Ceranka, Nicolas Michoux, Frédéric Lecouvet, Jef Vandemeulebroucke


  • Instance-Balanced Patch Sampling for Whole-Body Lesion Segmentation

    by Joris Wuts, Jakub Ceranka, Jef Vandemeulebroucke, Frédéric Lecouvet

  • Computer-Assisted Surgical Planning for DIEP Flap Breast Reconstruction Surgery

    by Jakub Ceranka, Diego Lamtenzan, Pieter Boonen, Ayush Kapila, Carola Brussaard, Moustapha Hamdi, Jef Vandemeulebroucke

  • Open Access

    Computer-vision based analysis of the neurosurgical scene – A systematic review

    by Félix Buyck, Jef Vandemeulebroucke, Jakub Ceranka, Frederick Van Gestel, Jan Frederick Cornelius, Johnny Duerinck, Michaël Bruneau


  • Computer-aided diagnosis of skeletal metastases in multi-parametric whole-body MRI

    by Jakub Ceranka, Joris Wuts, Ophélye Chiabai, Frédéric Lecouvet, Jef Vandemeulebroucke


  • Comparison of intra- and inter-patient intensity standardization methods for multi-parametric whole-body MRI

    by Jakub Ceranka, Frédéric Lecouvet, Nicolas Michoux, Johan de Mey, Hubert Raeymaekers, Thierry Metens, Jef Vandemeulebroucke

    Objective. To test and compare different intensity standardization approaches for whole-body multi-parametric MR images, aiming to compensate voxel intensity differences between scans. These differences, common for magnetic resonance imaging, pose problems in image quantification, assessment of changes between a baseline and follow-up scan, and hinder performance of image processing and machine learning algorithms. Approach. In this work, we present a comparison on the accuracy of intensity standardization approaches with increasing complexity, for intra- and inter-patient multi-parametric whole-body MRI. Several approaches were used: z-scoring of the intensities, piecewise linear mapping and deformable mapping of intensity distributions into established reference intensity space. For each method, the impact on standardization algorithm on the use of single image or average population distribution reference; as well as, whole image and region of interest were additionally investigated. All methods were validated on a data set of 18 whole-body anatomical and diffusion-weighted MR scans consisting of baseline and follow-up examinations acquired from advanced prostate cancer patients and healthy volunteers. Main results. The piecewise linear intensity standardisation approach provided the best compromise between standardization accuracy and method stability, with average deviations in intensity profile of 0.011-0.027 and mean absolute difference of 0.29-0.37 standard score (intra-patient) and 0.014-0.056 (inter-patient), depending on the type of used MR modality. Significance. Linear piecewise approaches showed the overall best performance across multiple validation metrics, mostly because of its robustness. The inter-patient standardization proved to perform better when using population average reference image; in contrary to intra-patient approach, where the best results were achieved by standardizing towards a reference image taken as the baseline scan.


  • Open Access

    Automated Motion Analysis of Bony Joint Structures from Dynamic Computer Tomography Images: A Multi-Atlas Approach

    by Benyameen Keelson, Luca Buzzatti, Jakub Ceranka, Adrián Gutiérrez, Simone Battista, Thierry Scheerlinck, Gert Van Gompel, Johan De Mey, Erik Cattrysse, Nico Buls, et al.

    Dynamic computer tomography (CT) is an emerging modality to analyze in-vivo joint kinematics at the bone level, but it requires manual bone segmentation and, in some instances, landmark identification. The objective of this study is to present an automated workflow for the assessment of three-dimensional in vivo joint kinematics from dynamic musculoskeletal CT images. The proposed method relies on a multi-atlas, multi-label segmentation and landmark propagation framework to extract bony structures and detect anatomical landmarks on the CT dataset. The segmented structures serve as regions of interest for the subsequent motion estimation across the dynamic sequence. The landmarks are propagated across the dynamic sequence for the construction of bone embedded reference frames from which kinematic parameters are estimated. We applied our workflow on dynamic CT images obtained from 15 healthy subjects on two different joints: thumb base (n = 5) and knee (n = 10). The proposed method resulted in segmentation accuracies of 0.90 ± 0.01 for the thumb dataset and 0.94 ± 0.02 for the knee as measured by the Dice score coefficient. In terms of motion estimation, mean differences in cardan angles between the automated algorithm and manual segmentation, and landmark identification performed by an expert were below 1°. Intraclass correlation (ICC) between cardan angles from the algorithm and results from expert manual landmarks ranged from 0.72 to 0.99 for all joints across all axes. The proposed automated method resulted in reproducible and reliable measurements, enabling the assessment of joint kinematics using 4DCT in clinical routine.


  • Multi‐atlas segmentation of the skeleton from whole‐body MRI—Impact of iterative background masking

    by Jakub Ceranka, Sabrina Verga, Maryna Kvasnytsia, Frédéric Lecouvet, Nicolas Michoux, Johan de Mey, Hubert Raeymaekers, Thierry Metens, Julie Absil, Jef Vandemeulebroucke

    Purpose: To improve multi‐atlas segmentation of the skeleton from whole‐body MRI. In particular, we study the effect of employing the atlas segmentations to iteratively mask tissues outside of the region of interest to improve the atlas alignment and subsequent segmentation.Methods: An improved atlas registration scheme is proposed. Starting from a suitable initial alignment, the alignment is refined by introducing additional stages of deformable registration during which the image sampling is limited to the dilated atlas segmentation label mask. The performance of the method was demonstrated using leave‐one‐out cross‐validation using atlases of 10 whole‐body 3D‐T1 images of prostate cancer patients with bone metastases and healthy male volunteers, and compared to existing state of the art. Both registration accuracy and resulting segmentation quality, using four commonly used label fusion strategies, were evaluated.Results: The proposed method showed significant improvement in registration and segmentation accuracy with respect to the state of the art for all validation criteria and label fusion strategies, resulting in a Dice coefficient of 0.887 (STEPS label fusion). The average Dice coefficient for the multi‐atlas segmentation showed over 11% improvement with a decrease of false positive rate from 28.3% to 13.2%. For this application, repeated application of the background masking did not lead to significant improvement of the segmentation result.Conclusions: A registration strategy, relying on the use of atlas segmentations as mask during image registration was proposed and evaluated for multi‐atlas segmentation of whole‐body MRI. The approach significantly improved registration and final segmentation accuracy and may be applicable to other structures of interest.


  • Intensity Standardization of Skeleton in Follow-Up Whole-Body MRI

    by Jakub Ceranka, Sabrina Verga, Frédéric Lecouvet, Thierry Metens, Johan de Mey, Jef Vandemeulebroucke


  • Registration strategies for multi‐modal whole‐body MRI mosaicing

    by Jakub Ceranka, Mathias Polfliet, Frédéric Lecouvet, Nicolas Michoux, Johan de Mey, Jef Vandemeulebroucke

    To test and compare different registration approaches for performing whole-body diffusion-weighted (wbDWI) image station mosaicing, and its alignment to corresponding anatomical T1 whole-body image. Four different registration strategies aiming at mosaicing of diffusion-weighted image stations, and their alignment to the corresponding whole-body anatomical image, were proposed and evaluated. These included two-step approaches, where diffusion-weighted stations are first combined in a pairwise (Strategy 1) or groupwise (Strategy 2) manner and later non-rigidly aligned to the anatomical image; a direct pairwise mapping of DWI stations onto the anatomical image (Strategy 3); and simultaneous mosaicing of DWI and alignment to the anatomical image (Strategy 4). Additionally, different images driving the registration were investigated. Experiments were performed for 20 whole-body images of patients with bone metastases. Strategies 1 and 2 showed significant improvement in mosaicing accuracy with respect to the non-registered images (P < 0.006). Strategy 2 based on ADC images increased the alignment accuracy between DWI stations and the T1 whole-body image (P = 0.0009). A two-step registration strategy, relying on groupwise mosaicing of the ADC stations and subsequent registration to T1, provided the best compromise between whole-body DWI image quality and multi-modal alignment. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine.