JWJoris Wuts

Joris Wuts

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Joris Wuts has a total of 13 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Clinically aligned whole-body MRI segmentation of skeletal metastases via Supervised Anatomical Pretraining

    by Joris Wuts, Jakub Ceranka, Nicolas Michoux, Frédéric Lecouvet, Jef Vandemeulebroucke


  • Instance-Balanced Patch Sampling for Whole-Body Lesion Segmentation

    by Joris Wuts, Jakub Ceranka, Jef Vandemeulebroucke, Frédéric Lecouvet

  • Open Access

    Learning from Anatomy: Supervised Anatomical Pretraining (SAP) for Improved Metastatic Bone Disease Segmentation in Whole-Body MRI

    by Joris Wuts, Jakub Ceranka, Nicolas Michoux, Frédéric Lecouvet, Jef Vandemeulebroucke

    The segmentation of metastatic bone disease (MBD) in whole-body MRI (WB-MRI) is a challenging problem. Due to varying appearances and anatomical locations of lesions, ambiguous boundaries, and severe class imbalance, obtaining reliable segmentations requires large, well-annotated datasets capturing lesion variability. Generating such datasets requires substantial time and expertise, and is prone to error. While self-supervised learning (SSL) can leverage large unlabeled datasets, learned generic representations often fail to capture the nuanced features needed for accurate lesion detection. In this work, we propose a Supervised Anatomical Pretraining (SAP) method that learns from a limited dataset of anatomical labels. First, an MRI-based skeletal segmentation model is developed and trained on WB-MRI scans from healthy individuals for high-quality skeletal delineation. Then, we compare its downstream efficacy in segmenting MBD on a cohort of 44 patients with metastatic prostate cancer, against both a baseline random initialization and a state-of-the-art SSL method. SAP significantly outperforms both the baseline and SSL-pretrained models, achieving a normalized surface Dice of 0.76 and a Dice coefficient of 0.64. The method achieved a lesion detection F2 score of 0.44, improving on 0.24 (baseline) and 0.31 (SSL). When considering only clinically relevant lesions larger than 1~ml, SAP achieves a detection sensitivity of 100% in 28 out of 32 patients. Learning bone morphology from anatomy yields an effective and domain-relevant inductive bias that can be leveraged for the downstream segmentation task of bone lesions. All code and models are made publicly available.

  • Open Access

    Modality redundancy for MRI-based glioblastoma segmentation

    by Selene De Sutter, Joris Wuts, Wietse Geens, Anne-Marie Vanbinst, Johnny Duerinck, Jef Vandemeulebroucke

    Purpose: Automated glioblastoma segmentation from magnetic resonance imaging is generally performed on a four-modality input, including T1, contrast T1, T2 and FLAIR. We hypothesize that information redundancy is present within these image combinations, which can possibly reduce a model’s performance. Moreover, for clinical applications, the risk of encountering missing data rises as the number of required input modalities increases. Therefore, this study aimed to explore the relevance and influence of the different modalities used for MRI-based glioblastoma segmentation. Methods: After the training of multiple segmentation models based on nnU-Net and SwinUNETR architectures, differing only in their amount and combinations of input modalities, each model was evaluated with regard to segmentation accuracy and epistemic uncertainty. Results: Results show that T1CE-based segmentation (for enhanced tumor and tumor core) and T1CE-FLAIR-based segmentation (for whole tumor and overall segmentation) can reach segmentation accuracies comparable to the full-input version. Notably, the highest segmentation accuracy for nnU-Net was found for a three-input configuration of T1CE-FLAIR-T1, suggesting the confounding effect of redundant input modalities. The SwinUNETR architecture appears to suffer less from this, where said three-input and the full-input model yielded statistically equal results. Conclusion: The T1CE-FLAIR-based model can therefore be considered as a minimal-input alternative to the full-input configuration. Addition of modalities beyond this does not statistically improve and can even deteriorate accuracy, but does lower the segmentation uncertainty.


  • Computer-aided diagnosis of skeletal metastases in multi-parametric whole-body MRI

    by Jakub Ceranka, Joris Wuts, Ophélye Chiabai, Frédéric Lecouvet, Jef Vandemeulebroucke