Veronika Silliková
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Veronika Silliková has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Jana Jakubčinová
Department of Chemistry, Faculty of Natural Sciences and Informatics, Constantine The Philosopher University in Nitra, Nitra, Slovakia
4 shared publicationsSilvia Dulanská
Slovak Medical University, Bratislava, Slovakia
4 shared publicationsMiroslav Horník
Department of Ecochemistry and Radioecology, Faculty of Natural Sciences, University of SS. Cyril and Methodius in Trnava, Trnava, Slovakia
3 shared publicationsIgor Gomola
Slovak Medical University, Bratislava, Slovakia
2 shared publications- Silvia Dulanská
Slovak Medical University, Bratislava, Slovakia
2 shared publications - Ambati Ramu
Institute of Inorganic Chemistry, Slovak Academy of Sciences, Dubravska cesta 9, 854 36 Bratislava, Slovakia
1 shared publication
Latest Publications
- Open Access
- 3 August 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (12)
Strontium-90 determination in milk ash by cherenkov and gas-flow proportional counting: A comparison of three radiochemical separations
- 3 August 2026
- Published by Elsevier in Nuclear Engineering and Technology
- Vol. 58 (12)
Open AccessStrontium-90 determination in milk ash by cherenkov and gas-flow proportional counting: A comparison of three radiochemical separations
- Open Access
- 14 September 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (10) , 4335-4341
Fly ash sorbent modified with KMnO4 for the separation of important radionuclides
The main aim of this work was to develop a suitable sorbent for the separation and determination of 226Ra through 133Ba (radio tracer) in water samples using fly ash sorbent. After the modification with KMnO4 the effects of pH, competing ions, the possibility of elution, and the effect of water volume were tested. As a suitable eluent 6 mol/L HCl was chosen, while the sorbent worked best at pH 6–8. The developed method is advantageous for minimizing the time required for separation, the volume of chemicals used, and the waste generated after separation.
- 14 September 2023
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (10) , 4335-4341
Open AccessFly ash sorbent modified with KMnO4 for the separation of important radionuclides
The main aim of this work was to develop a suitable sorbent for the separation and determination of 226Ra through 133Ba (radio tracer) in water samples using fly ash sorbent. After the modification with KMnO4 the effects of pH, competing ions, the possibility of elution, and the effect of water volume were tested. As a suitable eluent 6 mol/L HCl was chosen, while the sorbent worked best at pH 6–8. The developed method is advantageous for minimizing the time required for separation, the volume of chemicals used, and the waste generated after separation.
- Open Access
Corrosion Behavior of Incoloy®800H, Hastelloy®G35® and 316L Stainless Steel in the Molten Eutectic Fluoride Mixture FLiNaK and Its Vapors
This paper discusses the findings of a corrosion experiment which investigates a transition area which is between the lower area and upper area of the sample. In this experiment, the lower half of the sample surface is exposed to molten salt and the upper half of the sample surface is exposed to the vapors generated by molten FLiNak salt. Incoloy®800H and Hastelloy®G35® alloys and 316L stainless steel were selected for the corrosion experiment on the basis of their Cr content. The experiment was conducted at 600 °C for a period of 100 h. The results of the experiment show that, in the transition area, no abrupt change in corrosion mechanism takes place; the experiments also give us information on how the degree of degradation varies across the three areas of the samples. The experiment also showed two distinct corrosion mechanisms operating in the test samples: intergranular corrosion in the SS316L stainless steel test sample and continuous corrosion in Hastelloy®G35®. The results also show a progressive reduction in the concentrations of F, K and Na in the upper areas compared to the lower areas for Hastelloy©G35®. Cr is shown to have a critical role in the corrosion process, even when the sample surface is not in direct contact with the molten salt and is only in contact with the vapors generated by the molten salt.
Open AccessCorrosion Behavior of Incoloy®800H, Hastelloy®G35® and 316L Stainless Steel in the Molten Eutectic Fluoride Mixture FLiNaK and Its Vapors
This paper discusses the findings of a corrosion experiment which investigates a transition area which is between the lower area and upper area of the sample. In this experiment, the lower half of the sample surface is exposed to molten salt and the upper half of the sample surface is exposed to the vapors generated by molten FLiNak salt. Incoloy®800H and Hastelloy®G35® alloys and 316L stainless steel were selected for the corrosion experiment on the basis of their Cr content. The experiment was conducted at 600 °C for a period of 100 h. The results of the experiment show that, in the transition area, no abrupt change in corrosion mechanism takes place; the experiments also give us information on how the degree of degradation varies across the three areas of the samples. The experiment also showed two distinct corrosion mechanisms operating in the test samples: intergranular corrosion in the SS316L stainless steel test sample and continuous corrosion in Hastelloy®G35®. The results also show a progressive reduction in the concentrations of F, K and Na in the upper areas compared to the lower areas for Hastelloy©G35®. Cr is shown to have a critical role in the corrosion process, even when the sample surface is not in direct contact with the molten salt and is only in contact with the vapors generated by the molten salt.
- 16 June 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (3) , 849-850
Answer to comments of Dr. Berek on the paper: Veronika Silliková, Jana Jakubčinová, Miroslav Horník, Igor Gomola, Silvia Dulanská, „ Determination of caesium-137 in water samples using modified carbon microfibers “, J. Radioanal. Nuclear Chem. (2022) 331:1275–1284, https://doi.org/10.1007/s10967-022–08212-5
- 16 June 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 332 (3) , 849-850
Answer to comments of Dr. Berek on the paper: Veronika Silliková, Jana Jakubčinová, Miroslav Horník, Igor Gomola, Silvia Dulanská, „ Determination of caesium-137 in water samples using modified carbon microfibers “, J. Radioanal. Nuclear Chem. (2022) 331:1275–1284, https://doi.org/10.1007/s10967-022–08212-5
- 31 January 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (3) , 1275-1284
Determination of caesium-137 in water samples using modified carbon microfibers
- 31 January 2022
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 331 (3) , 1275-1284
Determination of caesium-137 in water samples using modified carbon microfibers
- 9 April 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 324 (3) , 1225-1236
Impregnated fly ash sorbent for cesium-137 removal from water samples
- 9 April 2020
- Published by Springer Nature in Journal of Radioanalytical and Nuclear Chemistry
- Vol. 324 (3) , 1225-1236
Impregnated fly ash sorbent for cesium-137 removal from water samples
- Open Access
- 25 April 2017
- Published by Walter de Gruyter GmbH in Acta Chimica Slovaca
- Vol. 10 (1) , 61-64
Sequential determination of 99Tc and 126Sn in radioactive concentrate
This paper describes a new sequential method using anion exchange resin, which is commercially available from Eichrom Technologies, Inc., for the determination of 99Tc and 126Sn in nuclear waste samples. For the determination of non-actinide radionuclides in radioactive wastes, several methods have been recently introduced. This method is suitable for the separation of radionuclides 99Tc and 126Sn from acidic solutions. Samples after digestion were directly loaded in 2 mol·dm-3 HCl acid on a cation exchange resin and then on an anion exchange. They were eluted with HNO3. After elution, the eluted fractions were measured either by gamma spectrometry on an HPGe detector or liquid scintillation counter with high chemical recoveries for a short period of time. Activity concentrations of 126Sn were below minimum detectable activity (MDA) for each experiment. A new radioanalytical method for the sequential determination of 99Tc and 126Sn in radioactive concentrates has been developed and successfully applied. The main advantage of the method was the time required for the separation of radionuclides, which was only five hours, and single column separation for the determination of these radionuclides, which makes the method very effective and cheap.
- 25 April 2017
- Published by Walter de Gruyter GmbH in Acta Chimica Slovaca
- Vol. 10 (1) , 61-64
Open AccessSequential determination of 99Tc and 126Sn in radioactive concentrate
This paper describes a new sequential method using anion exchange resin, which is commercially available from Eichrom Technologies, Inc., for the determination of 99Tc and 126Sn in nuclear waste samples. For the determination of non-actinide radionuclides in radioactive wastes, several methods have been recently introduced. This method is suitable for the separation of radionuclides 99Tc and 126Sn from acidic solutions. Samples after digestion were directly loaded in 2 mol·dm-3 HCl acid on a cation exchange resin and then on an anion exchange. They were eluted with HNO3. After elution, the eluted fractions were measured either by gamma spectrometry on an HPGe detector or liquid scintillation counter with high chemical recoveries for a short period of time. Activity concentrations of 126Sn were below minimum detectable activity (MDA) for each experiment. A new radioanalytical method for the sequential determination of 99Tc and 126Sn in radioactive concentrates has been developed and successfully applied. The main advantage of the method was the time required for the separation of radionuclides, which was only five hours, and single column separation for the determination of these radionuclides, which makes the method very effective and cheap.