Aici Qiu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China
6 shared publicationsFengju Sun
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China
6 shared publicationsHao Wei
4 shared publicationsTianxue Liang
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology, Xi'an 710024, China
4 shared publications- Yixiang Hu
State Key Laboratory of Electrical Insulation and Power Equipment, Xi'an Jiaotong University, Xi'an 710049, China
3 shared publications Jiangtao Zeng
2 shared publications
Latest Publications
- 1 July 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (7) , 076102
Note: Novel trigger pulse feed method for mega-volt gas switch
It is difficult to feed the trigger pulse into an electrically triggered mega-volt switch, and the present note presents a novel trigger pulse feed method. The trigger pulse is introduced via a damping resistor, which is mounted between the inner and outer cylindrical electrodes of the pulse transmission line. The mega-volt pulse is damped because the voltage is resistively divided by the resistor and trigger cable arrangement. Both the complex breakdown processes of the switch and its insulation issues are experimentally studied. The function and the beneficial effects of the damping resistor, installed together with an additional inductor, are discussed. Finally, the parameters of these two damping components are set to 500 Ω and 2 μH values for which the switch has been demonstrated to work successfully at over 2.3 MV.
- 1 July 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (7) , 076102
Note: Novel trigger pulse feed method for mega-volt gas switch
It is difficult to feed the trigger pulse into an electrically triggered mega-volt switch, and the present note presents a novel trigger pulse feed method. The trigger pulse is introduced via a damping resistor, which is mounted between the inner and outer cylindrical electrodes of the pulse transmission line. The mega-volt pulse is damped because the voltage is resistively divided by the resistor and trigger cable arrangement. Both the complex breakdown processes of the switch and its insulation issues are experimentally studied. The function and the beneficial effects of the damping resistor, installed together with an additional inductor, are discussed. Finally, the parameters of these two damping components are set to 500 Ω and 2 μH values for which the switch has been demonstrated to work successfully at over 2.3 MV.
- 1 March 2015
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 17 (3) , 235-240
Numerical Simulation of Azimuthal Uniformity of Injection Currents in Single-Point-Feed Induction Voltage Adders
- 1 March 2015
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 17 (3) , 235-240
Numerical Simulation of Azimuthal Uniformity of Injection Currents in Single-Point-Feed Induction Voltage Adders
- 1 September 2014
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 16 (9) , 873-877
Modeling Methods for the Main Switch of High Pulsed-Power Facilities Based on Transmission Line Code
- 1 September 2014
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 16 (9) , 873-877
Modeling Methods for the Main Switch of High Pulsed-Power Facilities Based on Transmission Line Code
- 30 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 41 (8) , 2421-2426
Optimized Design of Azimuthal Transmission Lines for the Cell Driven by Two PFLs in Induction Voltage Adders
In this paper, a full-size 3-D electromagnetic model (without electrons) and an equivalent circuit model of a single cell in magnetically insulated induction voltage adders has been established. The simulation results of these two models agree well with each other. On the basis of these two models, azimuthal transmission lines for a cell driven by two pulse forming lines (PFLs) have been optimized. The optimization process aims at matching the impedance to the feed PFLs, ensuring uniform potential distribution along the insulator-stack, maximizing the symmetric current flow around the bore, and minimizing the waveform distortion of the injected pulse. A formula is presented to estimate the azimuthal impedance and an asymmetric coefficient is also defined to quantify the asymmetric extent of the feed pulses. The profiles of the total four candidate azimuthal lines have been simulated and analyzed. The simulation results indicate a relatively low feed asymmetry for all the four profiles. However, considering the waveform quality of the cell output voltage, the azimuthal line profiles with four points connected or wholly connected to the cathode plate are the most suitable for induction cells with two PFL feeding. And the corresponding coefficients $\delta$ are 3.1% and 7.6%, respectively. It is concluded that, when optimizing azimuthal lines for cells with two PFL feeding, the principal consideration should be matching the impedance instead of symmetrizing the current flow.- 30 July 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 41 (8) , 2421-2426
Optimized Design of Azimuthal Transmission Lines for the Cell Driven by Two PFLs in Induction Voltage Adders
In this paper, a full-size 3-D electromagnetic model (without electrons) and an equivalent circuit model of a single cell in magnetically insulated induction voltage adders has been established. The simulation results of these two models agree well with each other. On the basis of these two models, azimuthal transmission lines for a cell driven by two pulse forming lines (PFLs) have been optimized. The optimization process aims at matching the impedance to the feed PFLs, ensuring uniform potential distribution along the insulator-stack, maximizing the symmetric current flow around the bore, and minimizing the waveform distortion of the injected pulse. A formula is presented to estimate the azimuthal impedance and an asymmetric coefficient is also defined to quantify the asymmetric extent of the feed pulses. The profiles of the total four candidate azimuthal lines have been simulated and analyzed. The simulation results indicate a relatively low feed asymmetry for all the four profiles. However, considering the waveform quality of the cell output voltage, the azimuthal line profiles with four points connected or wholly connected to the cathode plate are the most suitable for induction cells with two PFL feeding. And the corresponding coefficients $\delta$ are 3.1% and 7.6%, respectively. It is concluded that, when optimizing azimuthal lines for cells with two PFL feeding, the principal consideration should be matching the impedance instead of symmetrizing the current flow.- 12 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 41 (7) , 1760-1766
Trigger Method Based on Secondary Induced Overvoltage for Linear Transformer Drivers
In this paper, a triggering method based on secondary induced overvoltage for a linear transformer driver (LTD) is proposed and investigated by simulation. A detailed circuit model established for the LTD is chosen to study the effect of some factors on the feasibility of this triggering method. The considered factors include the permeability, equivalent resistance of energy loss, saturation of magnetic cores, and the delay of gas switches in LTD cavities. Simulation results indicate that high equivalent resistance and high permeability of magnetic cores are helpful in realizing this trigger method. However, the resistance plays a leading role. An equivalent resistance of more than 1.5 Ω favors the realization of this trigger. However, a relative permeability of even 25 has not produced a fatal menace to this triggering method. The feasibility of this triggering necessitates the available volt-second product of the present magnetic cores to be expanded twice. As for gas switches, the interval given by secondary induced overvoltage would likely be long enough to complete their breakdown. From simulation results, it is shown that LTD switches could be rapidly closed under the action of such an overvoltage pulse with a rise time of less than 10 ns.
- 12 June 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 41 (7) , 1760-1766
Trigger Method Based on Secondary Induced Overvoltage for Linear Transformer Drivers
In this paper, a triggering method based on secondary induced overvoltage for a linear transformer driver (LTD) is proposed and investigated by simulation. A detailed circuit model established for the LTD is chosen to study the effect of some factors on the feasibility of this triggering method. The considered factors include the permeability, equivalent resistance of energy loss, saturation of magnetic cores, and the delay of gas switches in LTD cavities. Simulation results indicate that high equivalent resistance and high permeability of magnetic cores are helpful in realizing this trigger method. However, the resistance plays a leading role. An equivalent resistance of more than 1.5 Ω favors the realization of this trigger. However, a relative permeability of even 25 has not produced a fatal menace to this triggering method. The feasibility of this triggering necessitates the available volt-second product of the present magnetic cores to be expanded twice. As for gas switches, the interval given by secondary induced overvoltage would likely be long enough to complete their breakdown. From simulation results, it is shown that LTD switches could be rapidly closed under the action of such an overvoltage pulse with a rise time of less than 10 ns.
- 18 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 40 (1) , 83-89
Effect Analysis of Switch Prefire in Linear Transformer Drivers
In this paper, the circuit model capable of dealing with magnetizing characteristics of the magnetic cores and switch prefire is established for linear transformer driver (LTD) cavities in PSPICE. Through simulation, the effects of switch prefire on other components in LTD and its output current pulse have been analyzed associated with the variation of energy loss in magnetic cores. Simulation results indicate that a switch prefire in one cavity would produce oscillations added to the charge voltage of the other switches in this cavity and cavities adjacent immediately. The magnitudes of such oscillations have an intimate relation with the magnetic core loss equivalent resistance. The loss equivalent resistances in the range from 4 to 6 have produced moderate voltage oscillations. Experiments on the 300-kA LTD cavity developed by the Northwest Institute of Nuclear Technology proved that such oscillations added to the charge voltage of other switches are likely to increase the breakdown probability of them.
- 18 November 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 40 (1) , 83-89
Effect Analysis of Switch Prefire in Linear Transformer Drivers
In this paper, the circuit model capable of dealing with magnetizing characteristics of the magnetic cores and switch prefire is established for linear transformer driver (LTD) cavities in PSPICE. Through simulation, the effects of switch prefire on other components in LTD and its output current pulse have been analyzed associated with the variation of energy loss in magnetic cores. Simulation results indicate that a switch prefire in one cavity would produce oscillations added to the charge voltage of the other switches in this cavity and cavities adjacent immediately. The magnitudes of such oscillations have an intimate relation with the magnetic core loss equivalent resistance. The loss equivalent resistances in the range from 4 to 6 have produced moderate voltage oscillations. Experiments on the 300-kA LTD cavity developed by the Northwest Institute of Nuclear Technology proved that such oscillations added to the charge voltage of other switches are likely to increase the breakdown probability of them.