Yixiang Hu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yixiang Hu has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Jiangtao Zeng
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Xi'an 710024, China
10 shared publicationsFengju Sun
Northwest Institute of Nuclear Technology, P.O. box 69-10, Xi'an 710024, China
9 shared publicationsPeitian Cong
Northwest Institute of Nuclear Technology, P.O. box 69-10, Xi'an 710024, China
8 shared publicationsAici Qiu
5 shared publicationsTianxue Liang
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Xi'an 710049, China, and also with the Northwest Institute of Nuclear Technology, Xi'an 710024, China
5 shared publicationsXinjun Zhang
Northwest Institute of Nuclear Technology, P.O. box 69-10, Xi'an 710024, China
5 shared publications
Latest Publications
- 23 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (8) , 2810-2815
Studies on Principal Igniting Factors of the Initial Breakdown of Trigatron Switches
Investigations have been carried out into the mechanisms leading the initial breakdown of trigatron switches. The experimental work identifying effects of two different igniting factors are described and carried out in detail. One mechanism is when only the UV radiation generated from the ignition gap (gaps between the pin and adjacent electrodes) is applied to the main gap (gaps between the adjacent and opposite electrodes). The UV radiation is believed to produce free electrons through either photoionization or photodetachment in the main gap which in turn leads to the initial breakdown of the main gap. The second mechanism is when both the electron cloud and the UV radiation generated from the ignition gap are applied to the main gap. It is believed that both the electron cloud and the UV radiation result in the free electron in the main gap. Experimental results show that both the UV radiation and the electron cloud resulting from the ignition gap have obvious effects on the initial breakdown of the main gaps. Under conditions here, it seems that the electron cloud plays a more important role on the ignition of the initial breakdown.
- 23 July 2020
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 48 (8) , 2810-2815
Studies on Principal Igniting Factors of the Initial Breakdown of Trigatron Switches
Investigations have been carried out into the mechanisms leading the initial breakdown of trigatron switches. The experimental work identifying effects of two different igniting factors are described and carried out in detail. One mechanism is when only the UV radiation generated from the ignition gap (gaps between the pin and adjacent electrodes) is applied to the main gap (gaps between the adjacent and opposite electrodes). The UV radiation is believed to produce free electrons through either photoionization or photodetachment in the main gap which in turn leads to the initial breakdown of the main gap. The second mechanism is when both the electron cloud and the UV radiation generated from the ignition gap are applied to the main gap. It is believed that both the electron cloud and the UV radiation result in the free electron in the main gap. Experimental results show that both the UV radiation and the electron cloud resulting from the ignition gap have obvious effects on the initial breakdown of the main gaps. Under conditions here, it seems that the electron cloud plays a more important role on the ignition of the initial breakdown.
- 13 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 24 (4) , 1978-1984
Engineering design and primary experiment study of a 2.6-MV field-distortion oil switch
A 2.6-MV field-distortion oil switch was developed and tested. Engineering design theories of this switch, including electrode areas, oil anode-cathode (A-K) gaps, insulator-surface electric field, and A-K gaps of the pre-gas switch, were described in detail. Structure designs of the switch were presented. Electric-field distributions of the oil A-K gap and insulator surface were analyzed and discussed. Also, switch breakdown processes were estimated. Finally, performances of this switch were tested on the “JianGuang-I” facility (2.3MV/350ns). Preliminary experiment results show that with a 250kV trigger voltage, the switch-breakdown time delay is about 132ns and its jitter (the standard deviation) is less than 4.4ns.
- 13 September 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 24 (4) , 1978-1984
Engineering design and primary experiment study of a 2.6-MV field-distortion oil switch
A 2.6-MV field-distortion oil switch was developed and tested. Engineering design theories of this switch, including electrode areas, oil anode-cathode (A-K) gaps, insulator-surface electric field, and A-K gaps of the pre-gas switch, were described in detail. Structure designs of the switch were presented. Electric-field distributions of the oil A-K gap and insulator surface were analyzed and discussed. Also, switch breakdown processes were estimated. Finally, performances of this switch were tested on the “JianGuang-I” facility (2.3MV/350ns). Preliminary experiment results show that with a 250kV trigger voltage, the switch-breakdown time delay is about 132ns and its jitter (the standard deviation) is less than 4.4ns.
- 25 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 45 (6) , 1004-1009
Effects of cell-driving jitters on the output voltage of magnetically insulated induction voltage adders
Based on a 12-cell transmission line code model, the effects of cell-driving jitters on the output voltage (both the rise time and the flat-top waveform) of magnetically insulated induction voltage adders (MIVAs) were analyzed in detail. Simulation results show that the rise time (0.1-0.9) of the MIVA output voltage is a function of σ (the standard deviation of the cell-driving jitters) when N (the number of cells connected in series for an MIVA) is small. When cell-driving jitters follow a normal probability distribution, the rise time of the output voltages also accord well with normal distributions. Parameters of these distributions are analytically deduced and presented. For any experimental shot, there is a fiducial probability that the rise time falls into the analytic solution range (within a certain error range). With the same error range, the fiducial probability decreases as σ increases, while probabilities that the rise time are higher or lower than this range increase synchronously. Simulation results also indicate that cell-driving jitters have fewer effects on the flat-top peak of the MIVA output voltage. However, a series of ripple voltages is added on the flat-top waveform, and the average peak of these ripple voltages increases as σ increases.
- 25 April 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 45 (6) , 1004-1009
Effects of cell-driving jitters on the output voltage of magnetically insulated induction voltage adders
Based on a 12-cell transmission line code model, the effects of cell-driving jitters on the output voltage (both the rise time and the flat-top waveform) of magnetically insulated induction voltage adders (MIVAs) were analyzed in detail. Simulation results show that the rise time (0.1-0.9) of the MIVA output voltage is a function of σ (the standard deviation of the cell-driving jitters) when N (the number of cells connected in series for an MIVA) is small. When cell-driving jitters follow a normal probability distribution, the rise time of the output voltages also accord well with normal distributions. Parameters of these distributions are analytically deduced and presented. For any experimental shot, there is a fiducial probability that the rise time falls into the analytic solution range (within a certain error range). With the same error range, the fiducial probability decreases as σ increases, while probabilities that the rise time are higher or lower than this range increase synchronously. Simulation results also indicate that cell-driving jitters have fewer effects on the flat-top peak of the MIVA output voltage. However, a series of ripple voltages is added on the flat-top waveform, and the average peak of these ripple voltages increases as σ increases.
- 1 January 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (1) , 015106
Design and experiment studies of a 2.6-MV diverter system
Malfunctions of the Marx pre-fire or in the event that the main switch does not close were analyzed. Principles of the diverter system for protection of those events were introduced in detail. A 2.6 MV diverter system, consisting of an oil trigger switch and a Marx-coupled trigger generator, was developed. Based on “JianGuang-I” facility, a diverter-system test stand was established. And experiments with 2.3-MV working voltages were carried out to study the performance of this diverter system. Experiment results show that the time delay of this diverter system (from the beginning of the Marx erection to the time that the diverter-switch closes) is about 320 ns and its jitter (standard deviation) is about 8.9 ns. This diverter system has been tested more than 180 shots, and no problem has been encountered yet.
- 1 January 2017
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 88 (1) , 015106
Design and experiment studies of a 2.6-MV diverter system
Malfunctions of the Marx pre-fire or in the event that the main switch does not close were analyzed. Principles of the diverter system for protection of those events were introduced in detail. A 2.6 MV diverter system, consisting of an oil trigger switch and a Marx-coupled trigger generator, was developed. Based on “JianGuang-I” facility, a diverter-system test stand was established. And experiments with 2.3-MV working voltages were carried out to study the performance of this diverter system. Experiment results show that the time delay of this diverter system (from the beginning of the Marx erection to the time that the diverter-switch closes) is about 320 ns and its jitter (standard deviation) is about 8.9 ns. This diverter system has been tested more than 180 shots, and no problem has been encountered yet.
- 2 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 45 (1) , 100-105
Experimental Study of a 2.3-MV Field-Distortion Oil Switch
A 2.3-MV field-distortion oil switch was built and experimentally studied. Based on the JianGuang-I facility in China, an experimental stand was established for tests of the switch. Both static and dynamic performances of the switch were studied in detail. Experiment results show that the switch works well at approximately 2.3 MV with a 350-ns rise time. Field-distortion mechanisms worked well. In addition, the requirements of the trigger-voltage peak were not as rigorous as anticipated. With trigger voltages higher than 75 kV, the switch worked well with no problems. As the trigger voltage increased, the switch-breakdown delay and its jitters decreased rapidly. With a 250-kV trigger voltage, the breakdown delay of the switch was approximately 132 ns. Its jitter (the standard deviation) was as low as 4.4 ns. Finally, electrode erosions of the switch are also presented and analyzed.
- 2 December 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 45 (1) , 100-105
Experimental Study of a 2.3-MV Field-Distortion Oil Switch
A 2.3-MV field-distortion oil switch was built and experimentally studied. Based on the JianGuang-I facility in China, an experimental stand was established for tests of the switch. Both static and dynamic performances of the switch were studied in detail. Experiment results show that the switch works well at approximately 2.3 MV with a 350-ns rise time. Field-distortion mechanisms worked well. In addition, the requirements of the trigger-voltage peak were not as rigorous as anticipated. With trigger voltages higher than 75 kV, the switch worked well with no problems. As the trigger voltage increased, the switch-breakdown delay and its jitters decreased rapidly. With a 250-kV trigger voltage, the breakdown delay of the switch was approximately 132 ns. Its jitter (the standard deviation) was as low as 4.4 ns. Finally, electrode erosions of the switch are also presented and analyzed.
- 1 October 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (10) , 104708
Development of a Marx-coupled trigger generator with high voltages and low time delay
Coupled by the Marx of the “JianGuang-I” facility, a high voltage, low time-delay trigger generator was developed. Working principles of this trigger generator and its key issues were described in detail. Structures of this generator were also carefully designed and optimized. Based on the “JianGuang-I” Marx generator, a test stand was established. And a series of experiment tests were carried out to the study performance of this trigger generator. Experiment results show that the output voltage of this trigger generator can be continuously adjusted from 58 kV to 384 kV. The time delay (from the beginning of the Marx-discharging pulse to the time that the output pulse of the trigger generator arises) of this trigger pulse is about 200 ns and its peak time (0%∼100%) is less than 50 ns. Experiment results also indicate that the time-delay jitter of trigger voltages decreases rapidly with the increase in the peak voltage of trigger pulses. When the trigger voltage is higher than 250 kV, the time-delay jitters (the standard deviation) are less than 7.7 ns.
- 1 October 2016
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 87 (10) , 104708
Development of a Marx-coupled trigger generator with high voltages and low time delay
Coupled by the Marx of the “JianGuang-I” facility, a high voltage, low time-delay trigger generator was developed. Working principles of this trigger generator and its key issues were described in detail. Structures of this generator were also carefully designed and optimized. Based on the “JianGuang-I” Marx generator, a test stand was established. And a series of experiment tests were carried out to the study performance of this trigger generator. Experiment results show that the output voltage of this trigger generator can be continuously adjusted from 58 kV to 384 kV. The time delay (from the beginning of the Marx-discharging pulse to the time that the output pulse of the trigger generator arises) of this trigger pulse is about 200 ns and its peak time (0%∼100%) is less than 50 ns. Experiment results also indicate that the time-delay jitter of trigger voltages decreases rapidly with the increase in the peak voltage of trigger pulses. When the trigger voltage is higher than 250 kV, the time-delay jitters (the standard deviation) are less than 7.7 ns.
- 7 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 44 (10) , 1984-1988
Influences of cell-driving sequences on performances of magnetically insulated induction voltage adders
Based on the transmission line code model, influences of cell-driving sequences on both cell feedings and load voltages of a 12-stage magnetically insulated induction voltage adder were analyzed. Simulation results show that the cell-feeding voltages are obviously distorted under nonideal IVA sequences. The distortion degree (such as overshoot voltage and reverse voltage) would be greater as the increment in the parameter $n$ (the amount of cells that are synchronously driven per each group). These phenomena were analyzed in detail and well explained on the basis of transmission line theory. Simulation results also show that the rise time (10%–90%) of load voltages increases as the increment in the parameter $n$ , while the flattop time decreases gradually, which leads to longer rise time and shorter flattop time. But the alterations of the load peak and reverse voltages are negligible. These characteristics indicate that a wide variety of voltage-pulse shape can be formed by varying cell-driving sequences.
- 7 June 2016
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Plasma Science
- Vol. 44 (10) , 1984-1988
Influences of cell-driving sequences on performances of magnetically insulated induction voltage adders
Based on the transmission line code model, influences of cell-driving sequences on both cell feedings and load voltages of a 12-stage magnetically insulated induction voltage adder were analyzed. Simulation results show that the cell-feeding voltages are obviously distorted under nonideal IVA sequences. The distortion degree (such as overshoot voltage and reverse voltage) would be greater as the increment in the parameter $n$ (the amount of cells that are synchronously driven per each group). These phenomena were analyzed in detail and well explained on the basis of transmission line theory. Simulation results also show that the rise time (10%–90%) of load voltages increases as the increment in the parameter $n$ , while the flattop time decreases gradually, which leads to longer rise time and shorter flattop time. But the alterations of the load peak and reverse voltages are negligible. These characteristics indicate that a wide variety of voltage-pulse shape can be formed by varying cell-driving sequences.
- 1 March 2015
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 17 (3) , 235-240
Numerical Simulation of Azimuthal Uniformity of Injection Currents in Single-Point-Feed Induction Voltage Adders
- 1 March 2015
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 17 (3) , 235-240
Numerical Simulation of Azimuthal Uniformity of Injection Currents in Single-Point-Feed Induction Voltage Adders
- 1 September 2014
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 16 (9) , 873-877
Modeling Methods for the Main Switch of High Pulsed-Power Facilities Based on Transmission Line Code
- 1 September 2014
- Published by IOP Publishing in Plasma Science and Technology
- Vol. 16 (9) , 873-877
Modeling Methods for the Main Switch of High Pulsed-Power Facilities Based on Transmission Line Code
- 25 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 21 (4) , 1778-1783
Simulation analysis of transformer oil and glycerin as dielectric medium in inductive voltage adders
This paper gives the initial consideration of using glycerin medium to substitute the transformer oil widely used in present cells of magnetically insulated inductive voltage adders (MIVA). The effects of different mediums on MIVA performances such as electric field distribution, feed current uniformity, and cell output voltage, are simulated and compared. The simulation results indicate that, in case of four pulses driving simultaneously, the cells insulated by glycerin would output a pulse with the peak voltage increasing by about 8%. However, in case of four pulses driving separately, as replacing transformer oil with glycerin, the peak voltage of cell outputs decreases by 9%, and risetime increases dramatically from 32 ns to 59 ns. For the encountered issues caused by the glycerin medium, some solution methods are presented, and the feasibility of utilizing glycerin in MIVA cells is discussed.
- 25 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Dielectrics and Electrical Insulation
- Vol. 21 (4) , 1778-1783
Simulation analysis of transformer oil and glycerin as dielectric medium in inductive voltage adders
This paper gives the initial consideration of using glycerin medium to substitute the transformer oil widely used in present cells of magnetically insulated inductive voltage adders (MIVA). The effects of different mediums on MIVA performances such as electric field distribution, feed current uniformity, and cell output voltage, are simulated and compared. The simulation results indicate that, in case of four pulses driving simultaneously, the cells insulated by glycerin would output a pulse with the peak voltage increasing by about 8%. However, in case of four pulses driving separately, as replacing transformer oil with glycerin, the peak voltage of cell outputs decreases by 9%, and risetime increases dramatically from 32 ns to 59 ns. For the encountered issues caused by the glycerin medium, some solution methods are presented, and the feasibility of utilizing glycerin in MIVA cells is discussed.