Amanda M. Lines
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Amanda M. Lines has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Samuel A. Bryan
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
17 shared publications - Heather M. Felmy
Pacific Northwest National Laboratory
7 shared publications Amanda J. Casella
Energy and Environment Directorate, Pacific Northwest National Laboratory , Richland, Washington 99352, United States
5 shared publicationsHope E. Lackey
Pacific Northwest National Laboratory
5 shared publications- Nathan P. Bessen
Pacific Northwest National Laboratory
5 shared publications Gilbert L. Nelson
Department of Chemistry
4 shared publications
Latest Publications
- Open Access
- 30 April 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (18) , 18238-18250
Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement
- 30 April 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (18) , 18238-18250
Open AccessReal-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement
- Open Access
- 20 March 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (12) , 11796-11805
Spectroscopic Online Monitoring: Using a Multi-Track Visible Spectrometer to Facilitate a Mass Balance Study in a Simulated TALSPEAK Process
Nuclear energy is a promising low-carbon energy candidate to meet the increased demand for green energy, where the integration of fuel recycling can have significant benefits for material usage and waste reduction. Utilizing in situ monitoring tools can provide ample opportunities to better control and safeguard nuclear material recycle processes while also offering knowledge and insight into real-time solution properties. The simultaneous measurement of analytical targets in multiple process locations can enable real-time mass balance and material accountancy calculations. This is demonstrated here with a mass balance study of Nd3+ on countercurrent aqueous/organic metal extraction within a single centrifugal contactor. The Nd3+ concentration was simultaneously monitored at the inlets and outlets of both aqueous and organic phases using a visible absorbance detector that allowed for the simultaneous measurement of up to six locations. The Nd3+ concentration was calculated by using chemical data science algorithms, where model training sets were collected on a single track of the detector. The discussion includes addressing the challenges of using a model collected on a single track and applying it as a model across the other tracks on the detector. Each track of the detector corresponds to one measurement location on the contactor. The difference in the integrated moles of Nd3+ between the inlet and outlet at the end of the experiment was near zero, indicating that the mass balance of this experiment was maintained. Overall, the online spectroscopic monitoring was able to follow changing solution conditions and accurately measure the concentration of Nd3+ in different locations within the contactor system.
- 20 March 2025
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 10 (12) , 11796-11805
Open AccessSpectroscopic Online Monitoring: Using a Multi-Track Visible Spectrometer to Facilitate a Mass Balance Study in a Simulated TALSPEAK Process
Nuclear energy is a promising low-carbon energy candidate to meet the increased demand for green energy, where the integration of fuel recycling can have significant benefits for material usage and waste reduction. Utilizing in situ monitoring tools can provide ample opportunities to better control and safeguard nuclear material recycle processes while also offering knowledge and insight into real-time solution properties. The simultaneous measurement of analytical targets in multiple process locations can enable real-time mass balance and material accountancy calculations. This is demonstrated here with a mass balance study of Nd3+ on countercurrent aqueous/organic metal extraction within a single centrifugal contactor. The Nd3+ concentration was simultaneously monitored at the inlets and outlets of both aqueous and organic phases using a visible absorbance detector that allowed for the simultaneous measurement of up to six locations. The Nd3+ concentration was calculated by using chemical data science algorithms, where model training sets were collected on a single track of the detector. The discussion includes addressing the challenges of using a model collected on a single track and applying it as a model across the other tracks on the detector. Each track of the detector corresponds to one measurement location on the contactor. The difference in the integrated moles of Nd3+ between the inlet and outlet at the end of the experiment was near zero, indicating that the mass balance of this experiment was maintained. Overall, the online spectroscopic monitoring was able to follow changing solution conditions and accurately measure the concentration of Nd3+ in different locations within the contactor system.
- Open Access
- 29 August 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (37) , 38548-38556
Quantification of Lanthanides on a PMMA Microfluidic Device with Three Optical Pathlengths Using PCR of UV–Visible, NIR, and Raman Spectroscopy
Microfluidic devices (MFDs) offer customizable, low-cost, and low-waste platforms for performing chemical analyses. Optical spectroscopy techniques provide nondestructive monitoring of small sample volumes within microfluidic channels. Optical spectroscopy can probe speciation, oxidation state, and concentration of analytes as well as detect counterions and provide information about matrix composition. Here, ultraviolet-visible (UV-vis) absorbance, near-infrared (NIR) absorbance, and Raman spectroscopy are utilized on a custom poly(methyl methacrylate) (PMMA) MFD for the detection of three lanthanide nitrates in solution. Absorbance spectroscopies are conducted across three pathlengths using three portions of a contiguous channel within the MFD. Univariate and chemometric multivariate modeling, specifically Beer's law regression and principal component regression (PCR), respectively, are utilized to quantify the three lanthanides and the nitrate counterion. Models are composed of spectra from one or multiple pathlengths. Models are also constructed from multiblock spectra composed of UV-vis, NIR, and Raman spectra at one or multiple pathlengths. Root-mean-square errors (RMSE), limit of detection (LOD), and residual predictive deviation (RPD) values are compared for univariate, multivariate, multi-pathlength, and multiblock models. Univariate modeling produces acceptable results for analytes with a simple signal, such as samarium cations, producing an LOD of 5.49 mM. Multivariate and multiblock models produce enhanced quantification for analytes that experience spectral overlap and interfering nonanalyte signals, such as holmium, which had an LOD reduction from 7.21 mM for the univariate model down to 3.96 mM for the multiblock model. Multi-pathlength models are developed that maintain model errors in line with single-pathlength models. Multi-pathlength models have RPDs from 9.18 to 46.4, while incorporating absorbance spectra collected at optical paths of up to 10-fold difference in length.
- 29 August 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (37) , 38548-38556
Open AccessQuantification of Lanthanides on a PMMA Microfluidic Device with Three Optical Pathlengths Using PCR of UV–Visible, NIR, and Raman Spectroscopy
Microfluidic devices (MFDs) offer customizable, low-cost, and low-waste platforms for performing chemical analyses. Optical spectroscopy techniques provide nondestructive monitoring of small sample volumes within microfluidic channels. Optical spectroscopy can probe speciation, oxidation state, and concentration of analytes as well as detect counterions and provide information about matrix composition. Here, ultraviolet-visible (UV-vis) absorbance, near-infrared (NIR) absorbance, and Raman spectroscopy are utilized on a custom poly(methyl methacrylate) (PMMA) MFD for the detection of three lanthanide nitrates in solution. Absorbance spectroscopies are conducted across three pathlengths using three portions of a contiguous channel within the MFD. Univariate and chemometric multivariate modeling, specifically Beer's law regression and principal component regression (PCR), respectively, are utilized to quantify the three lanthanides and the nitrate counterion. Models are composed of spectra from one or multiple pathlengths. Models are also constructed from multiblock spectra composed of UV-vis, NIR, and Raman spectra at one or multiple pathlengths. Root-mean-square errors (RMSE), limit of detection (LOD), and residual predictive deviation (RPD) values are compared for univariate, multivariate, multi-pathlength, and multiblock models. Univariate modeling produces acceptable results for analytes with a simple signal, such as samarium cations, producing an LOD of 5.49 mM. Multivariate and multiblock models produce enhanced quantification for analytes that experience spectral overlap and interfering nonanalyte signals, such as holmium, which had an LOD reduction from 7.21 mM for the univariate model down to 3.96 mM for the multiblock model. Multi-pathlength models are developed that maintain model errors in line with single-pathlength models. Multi-pathlength models have RPDs from 9.18 to 46.4, while incorporating absorbance spectra collected at optical paths of up to 10-fold difference in length.
- Open Access
- 1 August 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (8)
Analytical capabilities for iodine detection: Review of possibilities for different applications
This Review summarizes a range of analytical techniques that can be used to detect, quantify, and/or distinguish between isotopes of iodine (e.g., long-lived 129I, short-lived 131I, stable 127I). One reason this is of interest is that understanding potential radioiodine release from nuclear processes is crucial to prevent environmental contamination and to protect human health as it can incorporate into the thyroid leading to cancer. It is also of interest for evaluating iodine retention performances of next-generation iodine off-gas capture materials and long-term waste forms for immobilizing radioiodine for disposal in geologic repositories. Depending upon the form of iodine (e.g., molecules, elemental, and ionic) and the matter state (i.e., solid, liquid, and gaseous), the available options can vary. In addition, several other key parameters vary between the methods discussed herein, including the destructive vs nondestructive nature of the measurement process (including in situ vs ex situ measurement options), the analytical data collection times, and the amount of sample required for analysis.
- 1 August 2024
- Published by AIP Publishing in AIP Advances
- Vol. 14 (8)
Open AccessAnalytical capabilities for iodine detection: Review of possibilities for different applications
This Review summarizes a range of analytical techniques that can be used to detect, quantify, and/or distinguish between isotopes of iodine (e.g., long-lived 129I, short-lived 131I, stable 127I). One reason this is of interest is that understanding potential radioiodine release from nuclear processes is crucial to prevent environmental contamination and to protect human health as it can incorporate into the thyroid leading to cancer. It is also of interest for evaluating iodine retention performances of next-generation iodine off-gas capture materials and long-term waste forms for immobilizing radioiodine for disposal in geologic repositories. Depending upon the form of iodine (e.g., molecules, elemental, and ionic) and the matter state (i.e., solid, liquid, and gaseous), the available options can vary. In addition, several other key parameters vary between the methods discussed herein, including the destructive vs nondestructive nature of the measurement process (including in situ vs ex situ measurement options), the analytical data collection times, and the amount of sample required for analysis.
- Open Access
- 23 July 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (31) , 33662-33670
PCA and PLS Analysis of Lanthanides Using Absorbance and Single-Beam Visible Spectra
During process monitoring applications, referenced optical spectroscopy, such as absorbance spectroscopy, can suffer from environmental and instrumental fluctuations that alter the intensity of irradiance reaching the spectrometer's detector at each detected frequency. Temperature, vibration, light source aging, instrument damage, detector aging, detector registry shifts, sampling cell degradation, and similar perturbations create situations in which a previously collected reference spectrum may no longer be valid for the current state of the system. This can lead to the calculation of poor-quality absorbance spectra that are unsuitable for qualitative or quantitative analysis based on prior calibration models. The use of single-beam spectra in the creation of multivariate calibration models circumvents the need for collecting and maintaining a stable reference spectrum throughout an ongoing chemical process. However, unlike absorbance spectra, which typically have a zero baseline, single-beam spectra contain a high background signal relative to an analyte signal, and they may also contain intense peaks from the light source. Here, multivariate principal component analysis (PCA) and partial least squares (PLS) regression models are built using single-beam and absorbance spectra to compare the efficacy of both types of spectra for qualitative and quantitative analyses of lanthanide solutions. A multileg fiber optic UV-visible spectrometer is utilized to collect samples under three distinct wavelength registries in three unique sampling cells and under lighting conditions spanning 0.2 to 2.0 relative transmittance. Under these conditions, single-beam spectral PCA models produced enhanced discrimination between sampling conditions, allowing spectra to be grouped by the instrumental conditions under which they were collected. Absorbance and single-beam PLS models produced equivalent quantitations of the lanthanide concentrations.
- 23 July 2024
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 9 (31) , 33662-33670
Open AccessPCA and PLS Analysis of Lanthanides Using Absorbance and Single-Beam Visible Spectra
During process monitoring applications, referenced optical spectroscopy, such as absorbance spectroscopy, can suffer from environmental and instrumental fluctuations that alter the intensity of irradiance reaching the spectrometer's detector at each detected frequency. Temperature, vibration, light source aging, instrument damage, detector aging, detector registry shifts, sampling cell degradation, and similar perturbations create situations in which a previously collected reference spectrum may no longer be valid for the current state of the system. This can lead to the calculation of poor-quality absorbance spectra that are unsuitable for qualitative or quantitative analysis based on prior calibration models. The use of single-beam spectra in the creation of multivariate calibration models circumvents the need for collecting and maintaining a stable reference spectrum throughout an ongoing chemical process. However, unlike absorbance spectra, which typically have a zero baseline, single-beam spectra contain a high background signal relative to an analyte signal, and they may also contain intense peaks from the light source. Here, multivariate principal component analysis (PCA) and partial least squares (PLS) regression models are built using single-beam and absorbance spectra to compare the efficacy of both types of spectra for qualitative and quantitative analyses of lanthanide solutions. A multileg fiber optic UV-visible spectrometer is utilized to collect samples under three distinct wavelength registries in three unique sampling cells and under lighting conditions spanning 0.2 to 2.0 relative transmittance. Under these conditions, single-beam spectral PCA models produced enhanced discrimination between sampling conditions, allowing spectra to be grouped by the instrumental conditions under which they were collected. Absorbance and single-beam PLS models produced equivalent quantitations of the lanthanide concentrations.
- Open Access
- 27 October 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (44) , 41696-41707
Quantification of Uranium in Complex Acid Media: Understanding Speciation and Mitigating for Band Shifts
In situ and real-time analysis of chemical systems, or online monitoring, has numerous benefits in all fields of chemistry. A common challenge can be found in matrix effects, where the addition of a new chemical species causes chemical interactions and changes the fingerprints of other chemical species in the system. This is demonstrated here by looking at the Raman and visible spectra of the uranyl ion within combined nitric acid and hydrofluoric acid media. This system is not only highly important to nuclear energy, a green and reliable option for energy portfolios, but also provides a clear chemistry example that can be applied to other chemical systems. The application of optical spectroscopy is discussed, along with the application and comparison of both multivariate curve resolution and HypSpec to deconvolute and understand speciation. Finally, the use of chemical data science in the form of chemometric modeling is used to demonstrate robust quantification of uranium within a complex chemical system where potential matrix effects are not known a priori.
- 27 October 2023
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 8 (44) , 41696-41707
Open AccessQuantification of Uranium in Complex Acid Media: Understanding Speciation and Mitigating for Band Shifts
In situ and real-time analysis of chemical systems, or online monitoring, has numerous benefits in all fields of chemistry. A common challenge can be found in matrix effects, where the addition of a new chemical species causes chemical interactions and changes the fingerprints of other chemical species in the system. This is demonstrated here by looking at the Raman and visible spectra of the uranyl ion within combined nitric acid and hydrofluoric acid media. This system is not only highly important to nuclear energy, a green and reliable option for energy portfolios, but also provides a clear chemistry example that can be applied to other chemical systems. The application of optical spectroscopy is discussed, along with the application and comparison of both multivariate curve resolution and HypSpec to deconvolute and understand speciation. Finally, the use of chemical data science in the form of chemometric modeling is used to demonstrate robust quantification of uranium within a complex chemical system where potential matrix effects are not known a priori.
- Open Access
- 28 October 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (44) , 40456-40465
Iodine and Carbonate Species Monitoring in Molten NaOH–KOH Eutectic Scrubber via Dual-Phase In Situ Raman Spectroscopy
Molten hydroxide scrubbing of off-gas vapors is a potential process to improve safety during the operation of generation IV molten salt nuclear reactors (MSRs). MSRs produce off-gases that can be vented by the reactor core and treated via off-gas scrubbers. Molten hydroxide scrubbers focus on capturing volatile iodine radionuclides, and they can also be used to capture aerosols and particulates and to neutralize acidic species. The performance of these scrubbers depends on the chemical interactions of the scrubbing medium with the off-gas species. Knowledge of the concentration and speciation of scrubbed or target species, as well as process and environmental interferents, can enable advanced operation of MSR off-gas treatment systems. Optical online monitoring is an excellent technology to provide this information in real time, while limiting the need for operators to interact with radioactive samples through hands-on interrogation. Raman spectroscopy can provide crucial chemical information on the state of the molten eutectic during treatment in the molten phase, as well as the gas phase. In this work, Raman spectroscopy is used to detect iodine species, specifically iodate, in the molten phase of a NaOH-KOH eutectic and to construct a calibration curve of the Raman signal of those species. Additionally, a carbonate interferent is followed from the gas phase to the liquid phase as a basis for reaching a Raman-aided mass balance of the molten hydroxide eutectic scrubber system.
- 28 October 2022
- Published by American Chemical Society (ACS) in ACS Omega
- Vol. 7 (44) , 40456-40465
Open AccessIodine and Carbonate Species Monitoring in Molten NaOH–KOH Eutectic Scrubber via Dual-Phase In Situ Raman Spectroscopy
Molten hydroxide scrubbing of off-gas vapors is a potential process to improve safety during the operation of generation IV molten salt nuclear reactors (MSRs). MSRs produce off-gases that can be vented by the reactor core and treated via off-gas scrubbers. Molten hydroxide scrubbers focus on capturing volatile iodine radionuclides, and they can also be used to capture aerosols and particulates and to neutralize acidic species. The performance of these scrubbers depends on the chemical interactions of the scrubbing medium with the off-gas species. Knowledge of the concentration and speciation of scrubbed or target species, as well as process and environmental interferents, can enable advanced operation of MSR off-gas treatment systems. Optical online monitoring is an excellent technology to provide this information in real time, while limiting the need for operators to interact with radioactive samples through hands-on interrogation. Raman spectroscopy can provide crucial chemical information on the state of the molten eutectic during treatment in the molten phase, as well as the gas phase. In this work, Raman spectroscopy is used to detect iodine species, specifically iodate, in the molten phase of a NaOH-KOH eutectic and to construct a calibration curve of the Raman signal of those species. Additionally, a carbonate interferent is followed from the gas phase to the liquid phase as a basis for reaching a Raman-aided mass balance of the molten hydroxide eutectic scrubber system.
- 1 April 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (4) , 046521
Electrochemical Oxidation and Speciation of Lanthanides in Potassium Carbonate Solution
Increasing lanthanide demand to support clean energy goals drives the need to develop more efficient approaches to separate adjacent lanthanides. Most approaches for lanthanide separations are not very selective and are based on small differences in lanthanide ionic radii. Concentrated potassium carbonate media has shown some potential to enable oxidation of praseodymium (Pr) and terbium (Tb) to their tetravalent states, which could ultimately enable a separation based on differences in oxidation states, but very little is known regarding the system’s chemistry. This work completes a detailed examination of cerium (Ce) redox chemistry in concentrated carbonate media to support the development of Pr and Tb oxidation studies. The half-wave potential (E 1/2 ) of the Ce(III)/(IV) redox couple is evaluated under various solution conditions and computational modeling of carbonate coordination environments is discussed. Cyclic voltammetry shows higher carbonate concentrations and temperatures can lower the potential required to oxidize Ce(III) by 54 mV (3.5 to 5.5 M) and 39 mV (from 10 °C to 70 °C). Chronoabsorptometry shows Ce(III) and Ce(IV) carbonate complexes are chemically stable and reversible. Computational modelling suggests the most likely coordination environment for the Ce(IV) complex is Ce(CO 3 ) 4 (OH) 5− which is less entropically favorable than the lowest energy Ce(III) complex, Ce(CO 3 ) 4 5− .
- 1 April 2022
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 169 (4) , 046521
Electrochemical Oxidation and Speciation of Lanthanides in Potassium Carbonate Solution
Increasing lanthanide demand to support clean energy goals drives the need to develop more efficient approaches to separate adjacent lanthanides. Most approaches for lanthanide separations are not very selective and are based on small differences in lanthanide ionic radii. Concentrated potassium carbonate media has shown some potential to enable oxidation of praseodymium (Pr) and terbium (Tb) to their tetravalent states, which could ultimately enable a separation based on differences in oxidation states, but very little is known regarding the system’s chemistry. This work completes a detailed examination of cerium (Ce) redox chemistry in concentrated carbonate media to support the development of Pr and Tb oxidation studies. The half-wave potential (E 1/2 ) of the Ce(III)/(IV) redox couple is evaluated under various solution conditions and computational modeling of carbonate coordination environments is discussed. Cyclic voltammetry shows higher carbonate concentrations and temperatures can lower the potential required to oxidize Ce(III) by 54 mV (3.5 to 5.5 M) and 39 mV (from 10 °C to 70 °C). Chronoabsorptometry shows Ce(III) and Ce(IV) carbonate complexes are chemically stable and reversible. Computational modelling suggests the most likely coordination environment for the Ce(IV) complex is Ce(CO 3 ) 4 (OH) 5− which is less entropically favorable than the lowest energy Ce(III) complex, Ce(CO 3 ) 4 5− .
- 23 February 2022
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 2 (3) , 465-473
Leveraging Multiple Raman Excitation Wavelength Systems for Process Monitoring of Nuclear Waste Streams
- 23 February 2022
- Published by American Chemical Society (ACS) in ACS ES&T Water
- Vol. 2 (3) , 465-473
Leveraging Multiple Raman Excitation Wavelength Systems for Process Monitoring of Nuclear Waste Streams
- 1 November 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1137, 11-18
A versatile and low-cost chip-to-world interface: Enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device
- 1 November 2020
- Published by Elsevier in Analytica Chimica Acta
- Vol. 1137, 11-18
A versatile and low-cost chip-to-world interface: Enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device