CFChristopher P. Favazza

Christopher P. Favazza

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Christopher P. Favazza has a total of 42 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Photon counting detector CTA for prostate arterial evaluation during the workup for prostate artery embolization

    by Forrest Linch, Prabhakar Rajiah, Michael Jundt, Alison Bashier, Kevin Wymer, Meghan Cooper, Derek Lomas, Andrea Ferrero, Christopher Favazza, Thomas Foley, et al.

    Purpose To evaluate small field of view (FOV) ultra-high spatial resolution pelvic photon-counting detector prostate CT angiograms (UHR PCD CTA) for identifying prostate arterial anatomy and extraprostatic anastomoses in patients undergoing workup for prostate artery embolization (PAE). Methods IRB-approved retrospective imaging and electronic medical record review of men who consecutively underwent UHR PCD CTA for PAE workup at our institution from 8/1/2022 to 12/1/2024. UHR PCD CTAs were evaluated by two vascular and interventional radiologists for main and accessory candidate prostatic arteries (PA/s) and anastomoses to penile, bladder, or rectal arteries. A main PA was defined as supplying the central gland and an accessory PA was defined as supplying the peripheral zone. PAs were categorized using the Carnevale classification. In patients who proceeded to PAE, digital subtraction angiograms (DSA) were retrospectively compared with UHR PCD CTA findings. Results UHR PCD CTA was obtained prior to PAE consultation for 50 men. We evaluated 100 pelvic sides, identifying 180 candidate PAs with a median of 3 candidate PAs per patient (mean, 3.6; range, 2–7). Overall, 56% (101/180) of candidate PAs were main and 44% (79/180) were accessory. Abridged Carnevale classifications: Type 5–21% (38/180). Eight accessory candidate PAs arose from the superior rectal artery. At least one candidate anastomosis arose from 40% (72/180) of candidate PAs. Of 95 total candidate anastomoses, 69 were extraprostatic (30 rectal, 20 bladder, 19 penile) and 26 were intraprostatic collaterals; 56% (53/95) arose from accessory and 44% (42/95) from main candidate PAs. Twenty-eight of 50 (56%) men underwent PAE, during which 72% (74/103) of available candidate PAs were selected, and prostatic supply was confirmed by DSA in 100% (74/74) of selected vessels. Conclusion Small FOV UHR PCD CTA is useful in identifying candidate PA supply, as well as potential extraprostatic anastomoses, providing an arterial roadmap for PAE planning. Candidate PA supply was confirmed by DSA in all selected vessels among patients who proceeded to PAE.

  • In Vivo Temperature Mapping during CT-Guided Thermal Ablations: Proof of Feasibility Using Spectral CT

    by Andrea Ferrero, Thomas D. Atwell, Brian T. Welch, A. Nicholas Kurup, Matthew R. Callstrom, Christopher P. Favazza


  • Open Access

    Thermometry mapping during CT-guided thermal ablations: proof of feasibility and internal validation using spectral CT

    by Kuan Zhang, Andrea Ferrero, Myung-Ho In, Christopher P Favazza

    Objective . Conventional computed tomography (CT) imaging does not provide quantitative information on local thermal changes during percutaneous ablative therapy of cancerous and benign tumors, aside from few qualitative, visual cues. In this study, we have investigated changes in CT signal across a wide range of temperatures and two physical phases for two different tissue mimicking materials, each. Approach . A series of experiments were conducted using an anthropomorphic phantom filled with water-based gel and olive oil, respectively. Multiple, clinically used ablation devices were applied to locally cool or heat the phantom material and were arranged in a configuration that produced thermal changes in regions with inconsequential amounts of metal artifact. Eight fiber optic thermal sensors were positioned in the region absent of metal artifact and were used to record local temperatures throughout the experiments. A spectral CT scanner was used to periodically acquire and generate electron density weighted images. Average electron density weighted values in 1 mm 3 volumes of interest near the temperature sensors were computed and these data were then used to calculate thermal volumetric expansion coefficients for each material and phase. Main results . The experimentally determined expansion coefficients well-matched existing published values and variations with temperature—maximally differing by 5% of the known value. As a proof of concept, a CT-generated temperature map was produced during a heating time point of the water-based gel phantom, demonstrating the capability to map changes in electron density weighted signal to temperature. Significance . This study has demonstrated that spectral CT can be used to estimate local temperature changes for different materials and phases across temperature ranges produced by thermal ablations.


  • Open Access

    Framework of metal insertion in the projection domain for image quality optimization in interventional computed tomography

    by Liqiang Ren, Andrea Ferrero, Christopher P. Favazza

    Percutaneous ablation has achieved broad clinical applications in locally treating metastatic lesions over the past decade.1 In part due to wide availability and excellent ability to delineate tumors from surrounding materials, computed tomography (CT) image guidance is routinely relied upon for treatment planning, intraprocedural guidance and monitoring, and post-treatment assessment of interventional oncology (IO) procedures.2,3 One drawback of CT imaging during these ablation procedures, however, is the potentially severe artifacts introduced by the metallic probes and devices used for treatment. These metal artifacts degrade the image quality in the anatomical region of interest (ROI). As a result, the interventional radiologist’s confidence in placement accuracy of the probe(s) relative to the tumor and sensitive tissues may be substantially reduced.4,5 Additionally, probe-induced artifacts may limit treatment zone evaluation during treatment monitoring. The artifacts generated by these probes vary greatly with their type, number, and relative orientation. As a result, CT protocol optimization for interventional procedures has been shown to be challenging and complex.5


  • Evaluation of Shimming Techniques on MRI Breast Image Quality at 1.5T

    by Wei Zhou, Christopher P Favazza, Jessica A Axmacher, Joshua D Trzasko, Jennifer R Geske, Christine U Lee

    The quality of all clinical MRI is dependent on B0 homogeneity, which is optimized during the shimming part of a prescan or preparatory phase before image acquisition. The purpose of this study was to assess shimming techniques clinically employed for breast MRI across our practice, and to determine factors that correlate with higher image quality for contrast-enhanced breast MRI at 1.5T. One hundred consecutive female patients were retrospectively collected with Institutional Review Board approval. Shimming-related parameters, including shim-box placement and shimming gradient offsets were extracted from prior contrast-enhanced 3D fat-suppressed T1-weighted gradient echo image acquisitions. Three breast radiologists evaluated these images for fat saturation, breast density, overall image quality, and artifacts. Technologist experience was also evaluated for variability of shimming. Generalized linear mixed models were used to compare acquisition parameters between fat saturation. P < 0.05 was considered as statistical significance. The percentage of soft tissue inside the field of view (FOV) (ie, Tissue/FOV) in the good fat-saturation group (0.37 ± 0.06) was significantly lower (P < 0.01) than that in the poor fat-saturation group (0.39 ± 0.06). Other shimming-related parameters were found not significantly affecting the fat-saturation outcomes. Technologists with more experience tended to have less variable shimming performance than junior technologists did. The quality of clinical MRI and especially breast MRI is highly dependent on shimming. Decreasing Tissue/FOV was associated with good image quality (good fat saturation). Optimization of shimming may require manual shimming or higher-order field-correction strategies.


  • Open Access

    Development of a robust MRI fiducial system for automated fusion of MR‐US abdominal images

    by Christopher P. Favazza, Krzysztof R. Gorny, Matthew R. Callstrom, Anil N. Kurup, Michael Washburn, Pamela S. Trester, Charles L. Fowler, Nicholas J. Hangiandreou

    We present the development of a two‐component magnetic resonance (MR) fiducial system, that is, a fiducial marker device combined with an auto‐segmentation algorithm, designed to be paired with existing ultrasound probe tracking and image fusion technology to automatically fuse MR and ultrasound (US) images. The fiducial device consisted of four ~6.4 mL cylindrical wells filled with 1 g/L copper sulfate solution. The algorithm was designed to automatically segment the device in clinical abdominal MR images. The algorithm's detection rate and repeatability were investigated through a phantom study and in human volunteers. The detection rate was 100% in all phantom and human images. The center‐of‐mass of the fiducial device was robustly identified with maximum variations of 2.9 mm in position and 0.9° in angular orientation. In volunteer images, average differences between algorithm‐measured inter‐marker spacings and actual separation distances were 0.53 ± 0.36 mm. “Proof‐of‐concept” automatic MR‐US fusions were conducted with sets of images from both a phantom and volunteer using a commercial prototype system, which was built based on the above findings. Image fusion accuracy was measured to be within 5 mm for breath‐hold scanning. These results demonstrate the capability of this approach to automatically fuse US and MR images acquired across a wide range of clinical abdominal pulse sequences.


  • Evaluation of feasibility of 1.5 Tesla prostate MRI using body coil RF transmit in a patient with an implanted vagus nerve stimulator

    by Christopher P. Favazza, Heidi A. Edmonson, Chi Ma, Yunhong Shu, Joel P. Felmlee, Robert E. Watson, Krzysztof R. Gorny

    To assess risks of RF-heating of a vagus nerve stimulator (VNS) during 1.5 T prostate MRI using body coil transmit and to compare these risks with those associated with MRI head exams using a transmit/receive head coil. Spatial distributions of radio-frequency (RF) B1 fields generated by transmit/receive (T/R) body and head coils were empirically assessed along the long axis of a 1.5 T MRI scanner bore. Measurements were obtained along the center axis of the scanner and laterally offset by 15 cm (body coil) and 7 cm (head coil). RF-field measurements were supplemented with direct measurements of RF-heating of 15 cm long copper wires affixed to and submerged in the “neck” region of the gelled saline-filled (sodium chloride and polyacrylic acid) “head-and-torso” phantom. Temperature elevations at the lead tips were measured using fiber-optic thermometers with the phantom positioned at systematically increased distances from the scanner isocenter. B1 field measurements demonstrated greater than 10 dB reduction in RF power at distances beyond 28 cm and 24 cm from isocenter for body and head coil, respectively. Moreover, RF power from body coil transmit at distances greater than 32 cm from isocenter was found to be lower than from the RF power from head coil transmit measured at locations adjacent to the coil array at its opening. Correspondingly, maximum temperature elevations at the tips of the copper wires decreased with increasing distance from isocenter — from 7.4°C at 0 cm to no appreciable heating at locations beyond 40 cm. For the particular scanner model evaluated in this study, positioning an implanted VNS farther than 32 cm from isocenter (configuration achievable for prostate exams) can reduce risks of RF-heating resulting from the body coil transmit to those associated with using a T/R head coil.

  • Use of a channelized Hotelling observer to assess CT image quality and optimize dose reduction for iteratively reconstructed images

    by Christopher P. Favazza, Andrea Ferrero, Lifeng Yu, Shuai Leng, Kyle L. McMillan, Cynthia H. McCollough

    The use of iterative reconstruction (IR) algorithms in CT generally decreases image noise and enables dose reduction. However, the amount of dose reduction possible using IR without sacrificing diagnostic performance is difficult to assess with conventional image quality metrics. Through this investigation, achievable dose reduction using a commercially available IR algorithm without loss of low contrast spatial resolution was determined with a channelized Hotelling observer (CHO) model and used to optimize a clinical abdomen/pelvis exam protocol. A phantom containing 21 low contrast disks—three different contrast levels and seven different diameters—was imaged at different dose levels. Images were created with filtered backprojection (FBP) and IR. The CHO was tasked with detecting the low contrast disks. CHO performance indicated dose could be reduced by 22% to 25% without compromising low contrast detectability (as compared to full-dose FBP images) whereas 50% or more dose reduction significantly reduced detection performance. Importantly, default settings for the scanner and protocol investigated reduced dose by upward of 75%. Subsequently, CHO-based protocol changes to the default protocol yielded images of higher quality and doses more consistent with values from a larger, dose-optimized scanner fleet. CHO assessment provided objective data to successfully optimize a clinical CT acquisition protocol.