HBHeiner von Boetticher

Heiner von Boetticher

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Heiner von Boetticher has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Albert Nienhaus

    Competence Center for Epidemiology and Health Services Research for Healthcare Professionals (CVcare), Institute for Health Services Research in Dermatology and Nursing (IVDP), University Medical Center Hamburg-Eppendorf (UKE), 20246 Hamburg, Germany

    1 shared publication
  • Björn Poppe

    Department of Medical Radiation Physics, Pius-Hospital, Carl von Ossietzky University Oldenburg, 26133 Oldenburg, Germany

    1 shared publication
  • Christiane Behr-Meenen

    Competence Centre for Epidemiology and Health Services Research for Healthcare Professionals (CVcare), Institute for Health Services Research in Dermatology and Nursing (IVDP), University Medical Centre Hamburg-Eppendorf (UKE), 20246 Hamburg, Germany

    1 shared publication
  • Jan Felix Kersten

    Institute for Health Services Research in Dermatology and Nursing, University Medical Center Hamburg-Eppendorf, 20251 Hamburg, Germany

    1 shared publication
  • Kerstin Weitmann

    Affiliation Institute for Community Medicine, Section Epidemiology of Health Care and Community Health, University Medicine Greifswald, Greifswald, Germany

    1 shared publication
  • Mario Liebmann

    Klinikum Links der Weser, Senator-Wessling-Str. 1, D-28277 Bremen, Germany

    1 shared publication

Latest Publications

  • Open Access

    Radiation Protection in Interventional Radiology/Cardiology—Is State-of-the-Art Equipment Used?

    by Christiane Behr-Meenen, Heiner von Boetticher, Jan Felix Kersten, Albert Nienhaus

    Interventional radiology/cardiology is one of the fields with the highest radiation doses for workers. For this reason, the International Commission on Radiological Protection (ICRP) published new recommendations in 2018 to shield staff from radiation. This study sets out to establish the extent to which these recommendations are observed in Germany. For the study, areas were selected which are known to have relatively high radiation exposure along with good conditions for radiological protection—interventional cardiology, radiology and vascular surgery. The study was advertised with the aid of an information flyer which was distributed via organisations including the German Cardiac Society (Deutsche Gesellschaft für Kardiologie- Herz- und Kreislaufforschung e. V.). Everyone who participated in our study received a questionnaire to record their occupational medical history, dosimetry, working practices, existing interventional installations and personal protective equipment. The results were compared with international recommendations, especially those of the ICRP, based on state-of-the-art equipment. A total of 104 respondents from eight German clinics took part in the survey. Four participants had been medically diagnosed with cataracts. None of the participants had previously worn an additional dosimeter over their apron to determine partial-body doses. The interventional installations recommended by the ICRP have not been fitted in all examination rooms and, where they have been put in place, they are not always used consistently. Just 31 participants (36.6%) stated that they “always” wore protective lead glasses or a visor. This study revealed considerable deficits in radiological protection—especially in connection with shielding measures and dosimetric practices pertaining to the head and neck—during a range of interventions. Examination rooms without the recommended interventional installations should be upgraded in the future. According to the principle of dose minimization, there is considerable potential for improving radiation protection. Temporary measurements should be taken over the apron to determine the organ-specific equivalent dose to the lens of the eye and the head.


  • Open Access

    Tables for effective dose assessment from diagnostic radiology (period 1946–1995) in epidemiologic studies

    by Merle Friederike Meiboom, Wolfgang Hoffmann, Kerstin Weitmann, Heiner von Boetticher

    Diagnostic radiology is a leading cause of man-made radiation exposure to the population. It is an important factor in many epidemiological studies as variable of interest or as potential confounder. The effective dose as a risk related quantity is the most often stated patient dose. Nevertheless, there exists no comprehensive quantification model for retrospective analysis for this quantity. This paper gives a catalog of effective dose values for common and rare examinations and demonstrates how to modify the dose values to adapt them to different calendar years using a quantification concept already used for retrospective analysis of the red bone marrow dose. It covers the time period of 1946 to 1995 and allows considering technical development and different practical standards over time. For an individual dose assessment, if the dose area product is known, factors are given for most examinations to convert the dose area product into the effective dose. Additionally factors are stated for converting the effective dose into the red bone marrow dose or vice versa.


  • Open Access

    A new method for effective dose calculation based on the ambient dose height distribution

    by Mario Liebmann, Niroojiny Sangarapillai, Björn Poppe, Heiner von Boetticher

    The realistic determination of effective dose of the staff in diagnostic radiology has been a challenge both for personal dosimetry and ambient dose measurement. A model for dosimetry of occupational exposure is presented that allows direct determination of effective dose from measured or even manufacturer given ambient dose distribution in front of the personnel. This model considers a wide range of radiation energies, different radiation protection situations, and gender effects.