Katharina Loot
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Katharina Loot has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Andreas Block
Institut für Medizinische Strahlenphysik und Strahlenschutz, Klinikum Dortmund, D-44137, Dortmund, Germany
1 shared publication- Andreas Block
Klinikum Dortmund gGmbH, Department of Medical Physics and Radiation Protection, Beurhausstr. 40, 44137 Dortmund, Germany
1 shared publication - Bernhard Spaan
Technische Universität Dortmund, Experimentelle Physik 5, Germany
1 shared publication Oliver Waletzko
Praxis für Strahlentherapie am Klinikum Dortmund, Germany
1 shared publication- Ralf Rohn
Praxis für Strahlentherapie am Klinikum Dortmund, Germany
1 shared publication
Latest Publications
- Open Access
- 3 October 2019
- Published by Wiley in Medical Physics
- Vol. 46 (12) , 5685-5689
Technical Note: Accuracy of MTF measurements with an edge phantom at megavoltage x‐ray energies
Purpose Measurement of the modulation transfer function (MTF) is performed by evaluating the response of an imaging system to a predefined input. To obtain accurate results when using an edge phantom, the detector input signal must resemble an ideal step function. The MTF of megavoltage (MV) imagers used in radiotherapy has been measured with highly absorbing edge phantoms fabricated from thick metal blocks. This study investigates the influence of the edge phantom design on the accuracy of the resulting MTF. Methods The MTF of an electronic portal imaging device (EPID) was measured at 6 MV beam quality with four edge phantoms made of lead with 1.3 cm, 3.3 cm, 5.0 cm and 10.0 cm thickness. Monte Carlo simulations were carried out for these and a selection of tungsten phantoms to determine the photon fluence at the imaging plane and quantify the systematic error in the MTF introduced by the edge phantom design. Results The measured MTF depends on the design of the edge phantom. The detector input signal of a thin phantom is affected by secondary radiation from the phantom itself, causing an overestimation of the MTF. The amount of secondary radiation can be reduced by increasing the phantom thickness or introducing an air gap between the phantom and the detector. Both methods introduce geometric unsharpness, which can result in an underestimation of the true MTF. Edge phantoms made from 4.0 cm thick tungsten or 5.0 cm thick lead induce comparatively small systematic errors of below 3 % or 5 %, respectively. Conclusions When MTF measurements are conducted at MV energies, even a highly absorbing edge phantom will introduce a systematic error of several percent. Direct comparison of MTFs obtained with different edge phantoms should therefore be treated with caution.
- 3 October 2019
- Published by Wiley in Medical Physics
- Vol. 46 (12) , 5685-5689
Open AccessTechnical Note: Accuracy of MTF measurements with an edge phantom at megavoltage x‐ray energies
Purpose Measurement of the modulation transfer function (MTF) is performed by evaluating the response of an imaging system to a predefined input. To obtain accurate results when using an edge phantom, the detector input signal must resemble an ideal step function. The MTF of megavoltage (MV) imagers used in radiotherapy has been measured with highly absorbing edge phantoms fabricated from thick metal blocks. This study investigates the influence of the edge phantom design on the accuracy of the resulting MTF. Methods The MTF of an electronic portal imaging device (EPID) was measured at 6 MV beam quality with four edge phantoms made of lead with 1.3 cm, 3.3 cm, 5.0 cm and 10.0 cm thickness. Monte Carlo simulations were carried out for these and a selection of tungsten phantoms to determine the photon fluence at the imaging plane and quantify the systematic error in the MTF introduced by the edge phantom design. Results The measured MTF depends on the design of the edge phantom. The detector input signal of a thin phantom is affected by secondary radiation from the phantom itself, causing an overestimation of the MTF. The amount of secondary radiation can be reduced by increasing the phantom thickness or introducing an air gap between the phantom and the detector. Both methods introduce geometric unsharpness, which can result in an underestimation of the true MTF. Edge phantoms made from 4.0 cm thick tungsten or 5.0 cm thick lead induce comparatively small systematic errors of below 3 % or 5 %, respectively. Conclusions When MTF measurements are conducted at MV energies, even a highly absorbing edge phantom will introduce a systematic error of several percent. Direct comparison of MTFs obtained with different edge phantoms should therefore be treated with caution.
- Open Access
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 661-663
Analysis of resolution properties for three generations of MV imagers in radiation therapy using the modulation transfer function
Imaging in radiation therapy has become an important part of clinical routine. In order to evaluate and compare the image quality of verification images from different imaging modalities, one needs objective criteria like the modulation transfer function (MTF). The aim of our study was to compare the resolution properties of three generations of electronic portal imaging devices (EPIDs), namely one fluoroscopic-optical system and two different flat-panel imaging systems.
- 7 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 661-663
Open AccessAnalysis of resolution properties for three generations of MV imagers in radiation therapy using the modulation transfer function
Imaging in radiation therapy has become an important part of clinical routine. In order to evaluate and compare the image quality of verification images from different imaging modalities, one needs objective criteria like the modulation transfer function (MTF). The aim of our study was to compare the resolution properties of three generations of electronic portal imaging devices (EPIDs), namely one fluoroscopic-optical system and two different flat-panel imaging systems.