Stephan Rosendahl
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Stephan Rosendahl has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Ludwig Büermann
Physikalisch-Technische Bundesanstalt Bundesallee 100 38116 Braunschweig Germany
3 shared publications A. Brown
Nikhef and the University of Amsterdam, Science Park, Netherlands
1 shared publicationA. Fieguth
Institut für Kernphysik, Westfälische Wilhelms-Universität Münster, Münster, Germany
1 shared publicationA. Manfredini
Department of Particle Physics and Astrophysics, Weizmann Institute of Science, Rehovot, Israel
1 shared publicationA. Molinario
INFN-Laboratori Nazionali del Gran Sasso and Gran Sasso Science Institute, L’Aquila, Italy
1 shared publicationA. P. Colijn
Nikhef and the University of Amsterdam, Science Park, Netherlands
1 shared publication
Latest Publications
- Open Access
Comprehensive procedure for personalized dosimetry in computed tomography
The purpose of this work is to develop viable procedures for verifying the applicability of personalized dosimetry in computed tomography (CT) using Monte Carlo-based simulations. Mobile equipment together with customized software was developed and used for rapid, non-invasive determination of equivalent source models of CT scanners under clinical conditions. Standard and anthropomorphic CT dose phantoms equipped with real-time CT dose probes at five representative positions were scanned. The accumulated dose was measured during the scan at the five positions. ImpactMC, a Monte Carlo-based CT dose software program, was used to simulate the scan. The necessary inputs were obtained from the scan parameters, from the equivalent source models and from the material-segmented CT images of the phantoms. Post-scan 3D dose distributions in the phantoms were simulated and the dose values calculated at the five positions inside the phantom were compared to measured dose values. Initial results were obtained by means of a General Electric Optima CT 660 and a Toshiba (Canon) Aquilion ONE. In general, the measured and calculated dose values were within relative uncertainties that had been estimated to be less than 10%. The procedures developed, which allow the post-CT scan dose to be measured and calculated at five points inside anthropomorphic phantoms, were found to be viable and rapid. The procedures are applicable to any scanner type under clinical conditions. Results show that the procedures are well suited for verifying the applicability of personalized CT dosimetry based on post-scan Monte Carlo calculations.
Open AccessComprehensive procedure for personalized dosimetry in computed tomography
The purpose of this work is to develop viable procedures for verifying the applicability of personalized dosimetry in computed tomography (CT) using Monte Carlo-based simulations. Mobile equipment together with customized software was developed and used for rapid, non-invasive determination of equivalent source models of CT scanners under clinical conditions. Standard and anthropomorphic CT dose phantoms equipped with real-time CT dose probes at five representative positions were scanned. The accumulated dose was measured during the scan at the five positions. ImpactMC, a Monte Carlo-based CT dose software program, was used to simulate the scan. The necessary inputs were obtained from the scan parameters, from the equivalent source models and from the material-segmented CT images of the phantoms. Post-scan 3D dose distributions in the phantoms were simulated and the dose values calculated at the five positions inside the phantom were compared to measured dose values. Initial results were obtained by means of a General Electric Optima CT 660 and a Toshiba (Canon) Aquilion ONE. In general, the measured and calculated dose values were within relative uncertainties that had been estimated to be less than 10%. The procedures developed, which allow the post-CT scan dose to be measured and calculated at five points inside anthropomorphic phantoms, were found to be viable and rapid. The procedures are applicable to any scanner type under clinical conditions. Results show that the procedures are well suited for verifying the applicability of personalized CT dosimetry based on post-scan Monte Carlo calculations.
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 171
[P252] Energy calibration of semi-conductor detectors for computed tomography
- 1 August 2018
- Published by Elsevier in Physica Medica
- Vol. 52, 171
[P252] Energy calibration of semi-conductor detectors for computed tomography
- Open Access
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 791-794
Dynamic determination of equivalent CT source models for personalized dosimetry
With improvements in CT technology, the need for reliable patient-specific dosimetry increased in the recent years. The accuracy of Monte-Carlo simulations for absolute dose estimation is related to scanner specific information on the X-ray spectra of the scanner as well as the form filter geometries and compositions. In this work a mobile measurement setup is developed, which allows both to determine the X-ray spectra and equivalent form filter of a specific scanner from just one helical scan in less than 2 minutes.
- 1 September 2017
- Published by Walter de Gruyter GmbH in Current Directions in Biomedical Engineering
- Vol. 3 (2) , 791-794
Open AccessDynamic determination of equivalent CT source models for personalized dosimetry
With improvements in CT technology, the need for reliable patient-specific dosimetry increased in the recent years. The accuracy of Monte-Carlo simulations for absolute dose estimation is related to scanner specific information on the X-ray spectra of the scanner as well as the form filter geometries and compositions. In this work a mobile measurement setup is developed, which allows both to determine the X-ray spectra and equivalent form filter of a specific scanner from just one helical scan in less than 2 minutes.
- Open Access
- 2 May 2017
- Published by Springer Nature in The European Physical Journal C
- Vol. 77 (5) , 1-12
Removing krypton from xenon by cryogenic distillation to the ppq level
- 2 May 2017
- Published by Springer Nature in The European Physical Journal C
- Vol. 77 (5) , 1-12
Open AccessRemoving krypton from xenon by cryogenic distillation to the ppq level