Kei Wagatsuma
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Kei Wagatsuma has a total of 67 co-authors. Here are the top co-authors by number of shared publications:
Kenji Ishii
Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, Itabashi-ku, Japan
12 shared publicationsKenta Miwa
Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan
10 shared publicationsYuto Kamitaka
Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, Itabashi-ku, Japan
8 shared publicationsKenji Ishibashi
Research Team for Neuroimaging, Tokyo Metropolitan Institute for Geriatrics and Gerontology, 35-2, Sakae-cho, Itabashi-ku, Tokyo 173-0015, Japan
6 shared publications- Kenji Ishii
Tokyo Metropolitan Institute of Geriatrics and Gerontology, Tokyo Japan
5 shared publications - Kenta Miwa
Department of Radiological Sciences, School of Health Sciences, Fukushima Medical University, Fukushima, Japan
5 shared publications
Latest Publications
- 29 August 2024
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 39 (1) , 21-30
Phantom test procedures for a new neuro-oncological amino acid PET tracer: [18F]fluciclovine
Objective Amino acid positron emission tomography (PET) examinations using anti-1-amino-3-[18F]-fluorocyclobutane-1-carboxylic acid ([18F]FACBC) were allowed for routine clinical use in July 2024. However, phantom test procedures for [18F]FACBC reconstruction parameters have not yet been established. The present study aimed to establish new phantom test procedures for [18F]FACBC brain PET imaging to determine optimal reconstruction parameters. Methods Background (BG) activity as well as hot sphere and target-to-background ratios (TBRs) of [18F]FACBC were estimated based on brain activity and tumor-to-normal tissue ratios (TNR) in a Japanese clinical trial of [18F]FACBC. Phantom experiments proceeded under [18F]FACBC or L-[methyl-11C]-methionine ([11C]MET) conditions. The number of iterations and the Gaussian filter parameters were determined from the reconstruction parameters %contrastmean and coefficients of variation (CVs) in ordered subset expectation maximization (OSEM) and time-of-flight (TOF) with or without point-spread-function (PSF) correction. Results The amounts of activity in the hot spheres and BG were 1.1 and 5.5 kBq/mL, respectively, and the TBR was 5.0 at the start of acquisition. The %contrastmean of all hot spheres was higher with [18F]FACBC than [11C]MET, and %contrastmean converged between 4 and 6 iterations in hot spheres with diameters < 10 mm. We used four iterations for OSEM + TOF and five for OSEM + TOF + PSF correction for [18F]FACBC and [11C]MET images. The CV was higher for [18F]FACBC than [11C]MET. The optimal sizes of Gaussian filters for OSEM + TOF and OSEM + TOF + PSF correction of image reconstruction were 5 mm for [18F]FACBC, and 4 and 3 mm, respectively, for [11C]MET images. Conclusions We estimated phantom activity and TBR based on brain activity in a Japanese clinical trial and established new phantom test procedures for [18F]FACBC. We recommend that the optimal reconstruction parameters for [18F]FACBC should be set to the same number of iterations as [11C]MET and that the FWHM of Gaussian filter should have a few mm higher than [11C]MET to reduce image noise from brain normal tissue.
- 29 August 2024
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 39 (1) , 21-30
Phantom test procedures for a new neuro-oncological amino acid PET tracer: [18F]fluciclovine
Objective Amino acid positron emission tomography (PET) examinations using anti-1-amino-3-[18F]-fluorocyclobutane-1-carboxylic acid ([18F]FACBC) were allowed for routine clinical use in July 2024. However, phantom test procedures for [18F]FACBC reconstruction parameters have not yet been established. The present study aimed to establish new phantom test procedures for [18F]FACBC brain PET imaging to determine optimal reconstruction parameters. Methods Background (BG) activity as well as hot sphere and target-to-background ratios (TBRs) of [18F]FACBC were estimated based on brain activity and tumor-to-normal tissue ratios (TNR) in a Japanese clinical trial of [18F]FACBC. Phantom experiments proceeded under [18F]FACBC or L-[methyl-11C]-methionine ([11C]MET) conditions. The number of iterations and the Gaussian filter parameters were determined from the reconstruction parameters %contrastmean and coefficients of variation (CVs) in ordered subset expectation maximization (OSEM) and time-of-flight (TOF) with or without point-spread-function (PSF) correction. Results The amounts of activity in the hot spheres and BG were 1.1 and 5.5 kBq/mL, respectively, and the TBR was 5.0 at the start of acquisition. The %contrastmean of all hot spheres was higher with [18F]FACBC than [11C]MET, and %contrastmean converged between 4 and 6 iterations in hot spheres with diameters < 10 mm. We used four iterations for OSEM + TOF and five for OSEM + TOF + PSF correction for [18F]FACBC and [11C]MET images. The CV was higher for [18F]FACBC than [11C]MET. The optimal sizes of Gaussian filters for OSEM + TOF and OSEM + TOF + PSF correction of image reconstruction were 5 mm for [18F]FACBC, and 4 and 3 mm, respectively, for [11C]MET images. Conclusions We estimated phantom activity and TBR based on brain activity in a Japanese clinical trial and established new phantom test procedures for [18F]FACBC. We recommend that the optimal reconstruction parameters for [18F]FACBC should be set to the same number of iterations as [11C]MET and that the FWHM of Gaussian filter should have a few mm higher than [11C]MET to reduce image noise from brain normal tissue.
- 12 August 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (4) , 1627-1637
Optimization of penalization function in Bayesian penalized likelihood reconstruction algorithm for [18F]flutemetamol amyloid PET images
Point-spread-function (PSF) correction is not recommended for amyloid PET images due to Gibbs artifacts. Q.Clear™, a Bayesian Penalized Likelihood (BPL) reconstruction method without incorporating PSF correction reduces these artifacts but degrades image contrast by our previous findings. The present study aimed to recover lost contrast by optimizing reconstruction parameters in time-of-flight (TOF) BPL reconstruction of amyloid PET images without PSF correction. We selected candidate conditions based on a phantom study and then determined which were optimal in a clinical study. Phantom images were reconstructed under conditions of 1‒9 iterations, β 300–1000 and γ factors from 2 to 10 in TOF-BPL without PSF correction. We evaluated the %contrast and the coefficients of variation (CV, %). Standardized uptake value ratios (SUVr) and Centiloid scales (CL) were calculated from PET images acquired from 71 participants after an [18F]flutemetamol injection. Both %contrast and CV were independent of iterations, whereas a trade-off was found between γ factors and β. We selected a γ factors of 5 without PSF correction (iterations, 1; β, 500) and of 10 without PSF correction (iterations, 1; β, 800) as candidates for clinical investigation. The SUVr and CL remained stable across various conditions, and CL scales effectively discriminated amyloid PET using measured values. The optimal reconstruction parameters of TOF-BPL for [18F]flutemetamol PET images were γ factor 10, iterations 1 and β 800, without PSF correction.
- 12 August 2024
- Published by Springer Nature in Physical and Engineering Sciences in Medicine
- Vol. 47 (4) , 1627-1637
Optimization of penalization function in Bayesian penalized likelihood reconstruction algorithm for [18F]flutemetamol amyloid PET images
Point-spread-function (PSF) correction is not recommended for amyloid PET images due to Gibbs artifacts. Q.Clear™, a Bayesian Penalized Likelihood (BPL) reconstruction method without incorporating PSF correction reduces these artifacts but degrades image contrast by our previous findings. The present study aimed to recover lost contrast by optimizing reconstruction parameters in time-of-flight (TOF) BPL reconstruction of amyloid PET images without PSF correction. We selected candidate conditions based on a phantom study and then determined which were optimal in a clinical study. Phantom images were reconstructed under conditions of 1‒9 iterations, β 300–1000 and γ factors from 2 to 10 in TOF-BPL without PSF correction. We evaluated the %contrast and the coefficients of variation (CV, %). Standardized uptake value ratios (SUVr) and Centiloid scales (CL) were calculated from PET images acquired from 71 participants after an [18F]flutemetamol injection. Both %contrast and CV were independent of iterations, whereas a trade-off was found between γ factors and β. We selected a γ factors of 5 without PSF correction (iterations, 1; β, 500) and of 10 without PSF correction (iterations, 1; β, 800) as candidates for clinical investigation. The SUVr and CL remained stable across various conditions, and CL scales effectively discriminated amyloid PET using measured values. The optimal reconstruction parameters of TOF-BPL for [18F]flutemetamol PET images were γ factor 10, iterations 1 and β 800, without PSF correction.
- 8 June 2024
- Published by Elsevier in Physica Medica
- Vol. 123, 103399
Development of a novel phantom for tau PET imaging
- 8 June 2024
- Published by Elsevier in Physica Medica
- Vol. 123, 103399
Development of a novel phantom for tau PET imaging
- Open Access
- 22 April 2024
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-16
Phantom and clinical evaluation of the Bayesian penalised likelihood reconstruction algorithm Q.Clear without PSF correction in amyloid PET images
Purpose: Bayesian penalised likelihood (BPL) reconstruction, which incorporates point-spread-function (PSF) correction, provides higher signal-to-noise ratios and more accurate quantitation than conventional ordered subset expectation maximization (OSEM) reconstruction. However, applying PSF correction to brain PET imaging is controversial due to Gibbs artefacts that manifest as unpredicted cortical uptake enhancement. The present study aimed to validate whether BPL without PSF would be useful for amyloid PET imaging. Methods: Images were acquired from Hoffman 3D brain and cylindrical phantoms for phantom study and 71 patients administered with [18F]flutemetamol in clinical study using a Discovery MI. All images were reconstructed using OSEM, BPL with PSF correction, and BPL without PSF correction. Count profile, %contrast, recovery coefficients (RCs), and image noise were calculated from the images acquired from the phantoms. Amyloid β deposition in patients was visually assessed by two physicians and quantified based on the standardised uptake value ratio (SUVR). Results: The overestimated radioactivity in profile curves was eliminated using BPL without PSF correction. The %contrast and image noise decreased with increasing β values in phantom images. Image quality and RCs were better using BPL with, than without PSF correction or OSEM. An optimal β value of 600 was determined for BPL without PSF correction. Visual evaluation almost agreed perfectly (κ = 0.91–0.97), without depending on reconstruction methods. Composite SUVRs did not significantly differ between reconstruction methods. Conclusion: Gibbs artefacts disappeared from phantom images using the BPL without PSF correction. Visual and quantitative evaluation of [18F]flutemetamol imaging was independent of the reconstruction method. The BPL without PSF correction could be the standard reconstruction method for amyloid PET imaging, despite being qualitatively inferior to BPL with PSF correction for [18F]flutemetamol amyloid PET imaging.
- 22 April 2024
- Published by Springer Nature in EJNMMI Physics
- Vol. 11 (1) , 1-16
Open AccessPhantom and clinical evaluation of the Bayesian penalised likelihood reconstruction algorithm Q.Clear without PSF correction in amyloid PET images
Purpose: Bayesian penalised likelihood (BPL) reconstruction, which incorporates point-spread-function (PSF) correction, provides higher signal-to-noise ratios and more accurate quantitation than conventional ordered subset expectation maximization (OSEM) reconstruction. However, applying PSF correction to brain PET imaging is controversial due to Gibbs artefacts that manifest as unpredicted cortical uptake enhancement. The present study aimed to validate whether BPL without PSF would be useful for amyloid PET imaging. Methods: Images were acquired from Hoffman 3D brain and cylindrical phantoms for phantom study and 71 patients administered with [18F]flutemetamol in clinical study using a Discovery MI. All images were reconstructed using OSEM, BPL with PSF correction, and BPL without PSF correction. Count profile, %contrast, recovery coefficients (RCs), and image noise were calculated from the images acquired from the phantoms. Amyloid β deposition in patients was visually assessed by two physicians and quantified based on the standardised uptake value ratio (SUVR). Results: The overestimated radioactivity in profile curves was eliminated using BPL without PSF correction. The %contrast and image noise decreased with increasing β values in phantom images. Image quality and RCs were better using BPL with, than without PSF correction or OSEM. An optimal β value of 600 was determined for BPL without PSF correction. Visual evaluation almost agreed perfectly (κ = 0.91–0.97), without depending on reconstruction methods. Composite SUVRs did not significantly differ between reconstruction methods. Conclusion: Gibbs artefacts disappeared from phantom images using the BPL without PSF correction. Visual and quantitative evaluation of [18F]flutemetamol imaging was independent of the reconstruction method. The BPL without PSF correction could be the standard reconstruction method for amyloid PET imaging, despite being qualitatively inferior to BPL with PSF correction for [18F]flutemetamol amyloid PET imaging.
- Open Access
- 21 April 2024
- Published by MDPI AG in Brain Sciences
- Vol. 14 (4) , 406
Deep Learning-Driven Estimation of Centiloid Scales from Amyloid PET Images with 11C-PiB and 18F-Labeled Tracers in Alzheimer’s Disease
Background: Standard methods for deriving Centiloid scales from amyloid PET images are time-consuming and require considerable expert knowledge. We aimed to develop a deep learning method of automating Centiloid scale calculations from amyloid PET images with 11C-Pittsburgh Compound-B (PiB) tracer and assess its applicability to 18F-labeled tracers without retraining. Methods: We trained models on 231 11C-PiB amyloid PET images using a 50-layer 3D ResNet architecture. The models predicted the Centiloid scale, and accuracy was assessed using mean absolute error (MAE), linear regression analysis, and Bland–Altman plots. Results: The MAEs for Alzheimer’s disease (AD) and young controls (YC) were 8.54 and 2.61, respectively, using 11C-PiB, and 8.66 and 3.56, respectively, using 18F-NAV4694. The MAEs for AD and YC were higher with 18F-florbetaben (39.8 and 7.13, respectively) and 18F-florbetapir (40.5 and 12.4, respectively), and the error rate was moderate for 18F-flutemetamol (21.3 and 4.03, respectively). Linear regression yielded a slope of 1.00, intercept of 1.26, and R2 of 0.956, with a mean bias of −1.31 in the Centiloid scale prediction. Conclusions: We propose a deep learning means of directly predicting the Centiloid scale from amyloid PET images in a native space. Transferring the model trained on 11C-PiB directly to 18F-NAV4694 without retraining was feasible.
- 21 April 2024
- Published by MDPI AG in Brain Sciences
- Vol. 14 (4) , 406
Open AccessDeep Learning-Driven Estimation of Centiloid Scales from Amyloid PET Images with 11C-PiB and 18F-Labeled Tracers in Alzheimer’s Disease
Background: Standard methods for deriving Centiloid scales from amyloid PET images are time-consuming and require considerable expert knowledge. We aimed to develop a deep learning method of automating Centiloid scale calculations from amyloid PET images with 11C-Pittsburgh Compound-B (PiB) tracer and assess its applicability to 18F-labeled tracers without retraining. Methods: We trained models on 231 11C-PiB amyloid PET images using a 50-layer 3D ResNet architecture. The models predicted the Centiloid scale, and accuracy was assessed using mean absolute error (MAE), linear regression analysis, and Bland–Altman plots. Results: The MAEs for Alzheimer’s disease (AD) and young controls (YC) were 8.54 and 2.61, respectively, using 11C-PiB, and 8.66 and 3.56, respectively, using 18F-NAV4694. The MAEs for AD and YC were higher with 18F-florbetaben (39.8 and 7.13, respectively) and 18F-florbetapir (40.5 and 12.4, respectively), and the error rate was moderate for 18F-flutemetamol (21.3 and 4.03, respectively). Linear regression yielded a slope of 1.00, intercept of 1.26, and R2 of 0.956, with a mean bias of −1.31 in the Centiloid scale prediction. Conclusions: We propose a deep learning means of directly predicting the Centiloid scale from amyloid PET images in a native space. Transferring the model trained on 11C-PiB directly to 18F-NAV4694 without retraining was feasible.
- 11 March 2024
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 38 (5) , 400-407
Impact of [11C]methionine PET with Bayesian penalized likelihood reconstruction on glioma grades based on new WHO 2021 classification
Objective The uptake of [11C]methionine in positron emission tomography (PET) imaging overlapped in earlier images of tumors. Bayesian penalized likelihood (BPL) reconstruction increases the quantitative values of tumors compared with conventional ordered subset-expectation maximization (OSEM). The present study aimed to grade glioma malignancy based on the new WHO 2021 classification using [11C]methionine PET images reconstructed using BPL. Methods We categorized 32 gliomas in 28 patients as grades 2/3 (n = 15) and 4 (n = 17) based on the WHO 2021 classification. All [11C]methionine images were reconstructed using OSEM + time-of-flight (TOF) and BPL + TOF (β = 200). Maximum standardized uptake value (SUVmax) and tumor-to-normal tissue ratio (T/Nmax) were measured at each lesion. Results The mean SUVmax was 4.65 and 4.93 in grade 2/3 and 6.38 and 7.11 in grade 4, and the mean T/Nmax was 7.08 and 7.22 in grade 2/3 and 9.30 and 10.19 in grade 4 for OSEM and BPL, respectively. The BPL significantly increased these values in grade 4 gliomas. The area under the receiver operator characteristic (ROC) curve (AUC) for SUVmax was the highest (0.792) using BPL. Conclusions The BPL increased mean SUVmax and mean T/Nmax in lesions with higher contrast such as grade 4 glioma. The discrimination power between grades 2/3 and 4 in SUVmax was also increased using [11C]methionine PET images reconstructed with BPL.
- 11 March 2024
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 38 (5) , 400-407
Impact of [11C]methionine PET with Bayesian penalized likelihood reconstruction on glioma grades based on new WHO 2021 classification
Objective The uptake of [11C]methionine in positron emission tomography (PET) imaging overlapped in earlier images of tumors. Bayesian penalized likelihood (BPL) reconstruction increases the quantitative values of tumors compared with conventional ordered subset-expectation maximization (OSEM). The present study aimed to grade glioma malignancy based on the new WHO 2021 classification using [11C]methionine PET images reconstructed using BPL. Methods We categorized 32 gliomas in 28 patients as grades 2/3 (n = 15) and 4 (n = 17) based on the WHO 2021 classification. All [11C]methionine images were reconstructed using OSEM + time-of-flight (TOF) and BPL + TOF (β = 200). Maximum standardized uptake value (SUVmax) and tumor-to-normal tissue ratio (T/Nmax) were measured at each lesion. Results The mean SUVmax was 4.65 and 4.93 in grade 2/3 and 6.38 and 7.11 in grade 4, and the mean T/Nmax was 7.08 and 7.22 in grade 2/3 and 9.30 and 10.19 in grade 4 for OSEM and BPL, respectively. The BPL significantly increased these values in grade 4 gliomas. The area under the receiver operator characteristic (ROC) curve (AUC) for SUVmax was the highest (0.792) using BPL. Conclusions The BPL increased mean SUVmax and mean T/Nmax in lesions with higher contrast such as grade 4 glioma. The discrimination power between grades 2/3 and 4 in SUVmax was also increased using [11C]methionine PET images reconstructed with BPL.
- 27 May 2023
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 37 (9) , 494-503
Toward standardization of tau PET imaging corresponding to various tau PET tracers: a multicenter phantom study
Objective Tau positron emission tomography (PET) imaging is a recently developed non-invasive tool that can detect the density and extension of tau neurofibrillary tangles. Tau PET tracers have been validated to harmonize and accelerate their development and implementation in clinical practice. Whereas standard protocols including injected dose, uptake time, and duration have been determined for tau PET tracers, reconstruction parameters have not been standardized. The present study conducted phantom experiments based on tau pathology to standardize quantitative tau PET imaging parameters and optimize reconstruction conditions of PET scanners at four Japanese sites according to the results of phantom experiments. Methods The activity of 4.0 and 2.0 kBq/mL for Hoffman 3D brain and cylindrical phantoms, respectively, was estimated from published studies of brain activity using [18F]flortaucipir, [18F]THK5351, and [18F]MK6240. We developed an original tau-specific volume of interest template for the brain based on pathophysiological tau distribution in the brain defined as Braak stages. We acquired brain and cylindrical phantom images using four PET scanners. Iteration numbers were determined as contrast and recover coefficients (RCs) in gray (GM) and white (WM) matter, and the magnitude of the Gaussian filter was determined from image noise. Results Contrast and RC converged at ≥ 4 iterations, the error rates of RC for GM and WM were < 15% and 1%, respectively, and noise was < 10% in Gaussian filters of 2–4 mm in images acquired using the four scanners. Optimizing the reconstruction conditions for phantom tau PET images acquired by each scanner improved contrast and image noise. Conclusions The phantom activity was comprehensive for first- and second-generation tau PET tracers. The mid-range activity that we determined could be applied to later tau PET tracers. We propose an analytical tau-specific VOI template based on tau pathophysiological changes in patients with AD to standardize tau PET imaging. Phantom images reconstructed under the optimized conditions for tau PET imaging achieved excellent image quality and quantitative accuracy.
- 27 May 2023
- Published by Springer Nature in Annals of Nuclear Medicine
- Vol. 37 (9) , 494-503
Toward standardization of tau PET imaging corresponding to various tau PET tracers: a multicenter phantom study
Objective Tau positron emission tomography (PET) imaging is a recently developed non-invasive tool that can detect the density and extension of tau neurofibrillary tangles. Tau PET tracers have been validated to harmonize and accelerate their development and implementation in clinical practice. Whereas standard protocols including injected dose, uptake time, and duration have been determined for tau PET tracers, reconstruction parameters have not been standardized. The present study conducted phantom experiments based on tau pathology to standardize quantitative tau PET imaging parameters and optimize reconstruction conditions of PET scanners at four Japanese sites according to the results of phantom experiments. Methods The activity of 4.0 and 2.0 kBq/mL for Hoffman 3D brain and cylindrical phantoms, respectively, was estimated from published studies of brain activity using [18F]flortaucipir, [18F]THK5351, and [18F]MK6240. We developed an original tau-specific volume of interest template for the brain based on pathophysiological tau distribution in the brain defined as Braak stages. We acquired brain and cylindrical phantom images using four PET scanners. Iteration numbers were determined as contrast and recover coefficients (RCs) in gray (GM) and white (WM) matter, and the magnitude of the Gaussian filter was determined from image noise. Results Contrast and RC converged at ≥ 4 iterations, the error rates of RC for GM and WM were < 15% and 1%, respectively, and noise was < 10% in Gaussian filters of 2–4 mm in images acquired using the four scanners. Optimizing the reconstruction conditions for phantom tau PET images acquired by each scanner improved contrast and image noise. Conclusions The phantom activity was comprehensive for first- and second-generation tau PET tracers. The mid-range activity that we determined could be applied to later tau PET tracers. We propose an analytical tau-specific VOI template based on tau pathophysiological changes in patients with AD to standardize tau PET imaging. Phantom images reconstructed under the optimized conditions for tau PET imaging achieved excellent image quality and quantitative accuracy.
- Open Access
- 24 March 2023
- Published by Springer Nature in Research Square
Towards standardization of tau PET imaging corresponding to various tau PET tracer: multi-center phantom study
Objective: Tau positron emission tomography (PET) imaging is a recently developed non-invasive tool that can detect the density and extension of tau neurofibrillary tangles. Tau PET tracers have been validated to harmonize and accelerate their development and implementation in clinical practice. Whereas standard protocols including injected dose, uptake time, and duration have been determined for tau PET tracers, reconstruction parameters have not been standardized. The present study conducted phantom experiments based on tau pathology to standardize quantitative tau PET imaging parameters and optimize reconstruction conditions of PET scanners at four Japanese sites according to the results of phantom experiments. Methods: The activity of 4.0 and 2.0 kBq/mL for 3D Hoffman brain and cylindrical phantoms, respectively was estimated from published studies of brain activity using [18F]flortaucipir, [18F]THK5351, and [18F]MK6240. We developed an original tau-specific volume of interest (VOI) template for the brain based on pathophysiological tau distribution in the brain defined as Braak stages. We acquired brain and cylindrical phantom images using four PET scanners. Iteration numbers were determined as contrast and recover coefficients (RCs) in grey (GM) and white (WM) matter, and the magnitude of the Gaussian filter was determined from image noise. Results: Contrast and RC converged at ≥ 4 iterations, the error rates of RC for GM and WM were < 15% and 1%, respectively, and noise was < 10% in Gaussian filters of 2–4 mm in images acquired using the four scanners. Optimizing the reconstruction conditions for phantom tau PET images acquired by each scanner, improved contrast and image noise. Conclusions: The phantom activity was comprehensive for first- and second-generation tau PET tracers. The mid-range activity that we determined could be applied to later tau PET tracers. We propose an analytical tau-specific VOI template based on tau pathophysiological changes in patients with AD to standardize tau PET imaging. Phantom images reconstructed under the optimized conditions for tau PET imaging achieved excellent image quality and quantitative accuracy.
- 24 March 2023
- Published by Springer Nature in Research Square
Open AccessTowards standardization of tau PET imaging corresponding to various tau PET tracer: multi-center phantom study
Objective: Tau positron emission tomography (PET) imaging is a recently developed non-invasive tool that can detect the density and extension of tau neurofibrillary tangles. Tau PET tracers have been validated to harmonize and accelerate their development and implementation in clinical practice. Whereas standard protocols including injected dose, uptake time, and duration have been determined for tau PET tracers, reconstruction parameters have not been standardized. The present study conducted phantom experiments based on tau pathology to standardize quantitative tau PET imaging parameters and optimize reconstruction conditions of PET scanners at four Japanese sites according to the results of phantom experiments. Methods: The activity of 4.0 and 2.0 kBq/mL for 3D Hoffman brain and cylindrical phantoms, respectively was estimated from published studies of brain activity using [18F]flortaucipir, [18F]THK5351, and [18F]MK6240. We developed an original tau-specific volume of interest (VOI) template for the brain based on pathophysiological tau distribution in the brain defined as Braak stages. We acquired brain and cylindrical phantom images using four PET scanners. Iteration numbers were determined as contrast and recover coefficients (RCs) in grey (GM) and white (WM) matter, and the magnitude of the Gaussian filter was determined from image noise. Results: Contrast and RC converged at ≥ 4 iterations, the error rates of RC for GM and WM were < 15% and 1%, respectively, and noise was < 10% in Gaussian filters of 2–4 mm in images acquired using the four scanners. Optimizing the reconstruction conditions for phantom tau PET images acquired by each scanner, improved contrast and image noise. Conclusions: The phantom activity was comprehensive for first- and second-generation tau PET tracers. The mid-range activity that we determined could be applied to later tau PET tracers. We propose an analytical tau-specific VOI template based on tau pathophysiological changes in patients with AD to standardize tau PET imaging. Phantom images reconstructed under the optimized conditions for tau PET imaging achieved excellent image quality and quantitative accuracy.
- 3 March 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (2) , 116-124
Decreased imaging time of amyloid PET using [18F]florbetapir can maintain quantitative accuracy
Shortening the amount of time required to acquire amyloid positron emission tomography (PET) brain images while maintaining the accuracy of quantitative evaluation would help to overcome motion artifacts associated with Alzheimer’s disease patients. The present study aimed to validate the quantitative accuracy of [18F]florbetapir ([18F]FBP) imaging over a shorter acquisition duration. Forty participants were injected with [18F]FBP, and PET images were acquired for 50–55, 50–60, and 50–70 min after injection. Three physicians visually assessed the reprocessed [18F]FBP images using a binary scale to classify them as amyloid β (Aβ) negative or positive. A mean composite standard uptake value ratio (cSUVR) > 1.075 was defined as Aβ-positive based on receiver operating characteristic curves. Inter-reader and inter-acquisition duration agreements with visual assessment were evaluated using Cohen’s kappa (κ). Binary visual discrimination of 102 for the 120 [18F]FBP images, was consistent among the three readers. Sixteen, sixteen, and fourteen of the 40 [18F]FBP images acquired for 50–55, 50–60, and 50–70 min after injection, respectively, were deemed Aβ-positive by visual assessment. The inter-rater agreement was high, and the inter-acquisition duration agreement was almost perfect. The cSUVR did not change significantly among the acquisition durations, and the acquisition duration did not affect the outcome of discrimination based on the cSUVR cutoff. A shorter acquisition duration changed the visual assessment outcomes. Stable quantitative values were derived from [18F]FBP images acquired within 5 min. cSUVR helped to improve the performance and confidence in the outcomes of visual assessment.
- 3 March 2022
- Published by Springer Nature in Radiological Physics and Technology
- Vol. 15 (2) , 116-124
Decreased imaging time of amyloid PET using [18F]florbetapir can maintain quantitative accuracy
Shortening the amount of time required to acquire amyloid positron emission tomography (PET) brain images while maintaining the accuracy of quantitative evaluation would help to overcome motion artifacts associated with Alzheimer’s disease patients. The present study aimed to validate the quantitative accuracy of [18F]florbetapir ([18F]FBP) imaging over a shorter acquisition duration. Forty participants were injected with [18F]FBP, and PET images were acquired for 50–55, 50–60, and 50–70 min after injection. Three physicians visually assessed the reprocessed [18F]FBP images using a binary scale to classify them as amyloid β (Aβ) negative or positive. A mean composite standard uptake value ratio (cSUVR) > 1.075 was defined as Aβ-positive based on receiver operating characteristic curves. Inter-reader and inter-acquisition duration agreements with visual assessment were evaluated using Cohen’s kappa (κ). Binary visual discrimination of 102 for the 120 [18F]FBP images, was consistent among the three readers. Sixteen, sixteen, and fourteen of the 40 [18F]FBP images acquired for 50–55, 50–60, and 50–70 min after injection, respectively, were deemed Aβ-positive by visual assessment. The inter-rater agreement was high, and the inter-acquisition duration agreement was almost perfect. The cSUVR did not change significantly among the acquisition durations, and the acquisition duration did not affect the outcome of discrimination based on the cSUVR cutoff. A shorter acquisition duration changed the visual assessment outcomes. Stable quantitative values were derived from [18F]FBP images acquired within 5 min. cSUVR helped to improve the performance and confidence in the outcomes of visual assessment.
- Open Access
- 9 January 2022
- Published by Wiley in Movement Disorders
- Vol. 37 (4) , 853-857
Adenosine A2A Receptor Occupancy by Caffeine After Coffee Intake in Parkinson's Disease
Background: Coffee intake can decrease the risk for Parkinson's disease (PD). Its beneficial effects are allegedly mediated by caffeine through adenosine A2A receptor (A2AR) antagonist action.Objective: We aimed to calculate occupancy rates of striatal A2ARs by caffeine after coffee intake in PD.Methods: Five patients with PD underwent 11C‐preladenant positron emission tomography scanning at baseline and after intake of coffee containing 129.5 mg (n = 3) or 259 mg (n = 2) of caffeine. Concurrently, serum caffeine levels were measured.Results: The mean serum caffeine level (μg/mL) was 0.374 at baseline and increased to 4.48 and 8.92 by 129.5 and 259 mg of caffeine, respectively. The mean occupancy rates of striatal A2ARs by 129.5 and 259 mg of caffeine were 54.2% and 65.1%, respectively.Conclusions: A sufficient A2AR occupancy can be obtained by drinking a cup of coffee, which is equivalent to approximately 100 mg of caffeine. © 2022 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.
- 9 January 2022
- Published by Wiley in Movement Disorders
- Vol. 37 (4) , 853-857
Open AccessAdenosine A2A Receptor Occupancy by Caffeine After Coffee Intake in Parkinson's Disease
Background: Coffee intake can decrease the risk for Parkinson's disease (PD). Its beneficial effects are allegedly mediated by caffeine through adenosine A2A receptor (A2AR) antagonist action.Objective: We aimed to calculate occupancy rates of striatal A2ARs by caffeine after coffee intake in PD.Methods: Five patients with PD underwent 11C‐preladenant positron emission tomography scanning at baseline and after intake of coffee containing 129.5 mg (n = 3) or 259 mg (n = 2) of caffeine. Concurrently, serum caffeine levels were measured.Results: The mean serum caffeine level (μg/mL) was 0.374 at baseline and increased to 4.48 and 8.92 by 129.5 and 259 mg of caffeine, respectively. The mean occupancy rates of striatal A2ARs by 129.5 and 259 mg of caffeine were 54.2% and 65.1%, respectively.Conclusions: A sufficient A2AR occupancy can be obtained by drinking a cup of coffee, which is equivalent to approximately 100 mg of caffeine. © 2022 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society.