ALAlfredo Lucas

Alfredo Lucas

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Alfredo Lucas has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Image Annotation by Eye Tracking: Accuracy and Precision of Centerlines of Obstructed Small-Bowel Segments Placed Using Eye Trackers

    by Alfredo Lucas, Kang Wang, Cynthia Santillan, Albert Hsiao, Claude B. Sirlin, Paul M. Murphy

    Small-bowel obstruction (SBO) is a common and important disease, for which machine learning tools have yet to be developed. Image annotation is a critical first step for development of such tools. This study assesses whether image annotation by eye tracking is sufficiently accurate and precise to serve as a first step in the development of machine learning tools for detection of SBO on CT. Seven subjects diagnosed with SBO by CT were included in the study. For each subject, an obstructed segment of bowel was chosen. Three observers annotated the centerline of the segment by manual fiducial placement and by visual fiducial placement using a Tobii 4c eye tracker. Each annotation was repeated three times. The distance between centerlines was calculated after alignment using dynamic time warping (DTW) and statistically compared to clinical thresholds for diagnosis of SBO. Intra-observer DTW distance between manual and visual centerlines was calculated as a measure of accuracy. These distances were 1.1 ± 0.2, 1.3 ± 0.4, and 1.8 ± 0.2 cm for the three observers and were less than 1.5 cm for two of three observers (P < 0.01). Intra- and inter-observer DTW distances between centerlines placed with each method were calculated as measures of precision. These distances were 0.6 ± 0.1 and 0.8 ± 0.2 cm for manual centerlines, 1.1 ± 0.4 and 1.9 ± 0.6 cm for visual centerlines, and were less than 3.0 cm in all cases (P < 0.01). Results suggest that eye tracking–based annotation is sufficiently accurate and precise for small-bowel centerline annotation for use in machine learning–based applications.


  • Blood Quality Diagnostic Device Detects Storage Differences Between Donors

    by Vivek P. Jani, Shawn Mailo, Ali Athar, Alfredo Lucas, Alexander T. Williams, Pedro Cabrales

    In 2013, nearly 15 million units of banked blood were transfused in the United States of America alone. Blood shortages are expected to increase globally. Donated blood is not equal due to differences in quality and deterioration rate. There are no methods to detect time-dependent biochemical and biophysical changes of red blood cells (RBCs) or the deterioration rate of donated RBCs. Nine randomly selected RBC units collected by the San Diego Blood Bank were examined for interdonor variability over six weeks of storage. In vitro RBC quality was assessed weekly by conventional biochemical tests including free Hb, K+, ATP, P50, 2,3 DPG, lactate, and pH. Deformability was measured via cell filtration. Briefly, the RBC suspension (10% Hct), was forced through a 5.0- μ m pore membrane (106 mm 2 ) at various flow rates. No interdonor variability in biochemical or mechanical parameters was observed at baseline. Interdonor variability in biochemical properties (free Hb, K+, ATP, P50, 2,3 DPG, lactate, and pH) was observed after 14 days of storage. However, significant differences from baseline in RBC mechanical properties (i.e., filterability) were observed as early as 7 days into storage at the lowest flow rates and after 28 days of storage at all flow rates. There was a net decrease in filterability over time for all donors, but the rate at which filterability decreased (i.e., deterioration rates) was different when comparing individual donors. Changes in all biochemical parameters were significant different between donors. These data suggest that filterability is more sensitive to changes in blood quality than conventional biochemical parameters.