Vasyl Makarov
Vasyl Makarov has a total of 31 co-authors. Here are the top co-authors by number of shared publications:
- Mykola Korzh
Sytenko Institute of Spine and Joint Pathology National Academy of Medical Sciences of Ukraine, Kharkiv, Ukraine
8 shared publications - Igor Boyko4 shared publications
Dmitriy Shcherbakov
3 shared publications- Gleb Lazarenko3 shared publications
- Ninel V. Dedukh
D.F. Chebotarev Institute of Gerontology of the National Academy of Medical Sciences of Ukraine, Kyiv, Ukraine
3 shared publications Olga Pidgaiska
ДУ «Інститут патології хребта та суглобів ім. проф. М. І. Ситенка НАМН України», Харків
3 shared publications
Latest Publications
- Open Access
- 29 June 2025
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 2,p. 29-37
SHORT-TERM OUTCOMES OF USING CUSTOM 3D PRINTED BASE PLATES IN REVERSE SHOULDER ARTHROPLASTY FOR PATIENTS WITH GLENOID CAVITY DEFECTS
Objective. To conduct a retrospective analysis of the short-term clinical and radiographic outcomes of reverse total shoulder arthroplasty using custom glenoid base plates in patients with glenoid cavity defects. Methods. We retrospectively studied the surgical outcomes of 10 patients with defects of the glenoid cavity who underwent reverse total shoulder arthroplasty using individual glenoid base plates. The average follow-up period postsurgery was (2.6 ± 1.6) years. The mean age of the patients was (62.4 ± 5.6) years, including 7 women (70 %) and 3 men (30 %). Two patients (one woman and one man) underwent RTSA on both shoulders, resulting in a total of 12 RTSA procedures performed on 10 patients. All patients underwent shoulder joint imaging using spiral computed tomography, modeling of the individual base plate implant for the glenoid part of the endoprosthesis, and fabrication of the implant using 3D printing with titanium powder. The function of the shoulder joint was evaluated using the Constant-Murley Shoulder Score (CMS). Results. The mean cortical index was 0.38 ± 0.06. Lateralization and distalization angles were measured at 80° ± 5.6° and 55° ± 8.2°, respectively. The average active range of motion for external rotation was 60° ± 5.5°, flexion and elevation of the upper limb at the shoulder joint (including the scapula) was 135° ± 8.4°, internal rotation was 85° ± 3.4°, and abduction of the shoulder joint (including the scapula) was 145° ± 10.2°. The mean score on the CMS scale was 85. Conclusion. The retrospective analysis demonstrates a significant reduction or complete absence of pain syndrome along with improved functional outcomes in patients after RTSA with glenoid cavity defects when using custom base plates for the glenoid part of the reverse shoulder endoprosthesis.
- 29 June 2025
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 2,p. 29-37
Open AccessSHORT-TERM OUTCOMES OF USING CUSTOM 3D PRINTED BASE PLATES IN REVERSE SHOULDER ARTHROPLASTY FOR PATIENTS WITH GLENOID CAVITY DEFECTS
Objective. To conduct a retrospective analysis of the short-term clinical and radiographic outcomes of reverse total shoulder arthroplasty using custom glenoid base plates in patients with glenoid cavity defects. Methods. We retrospectively studied the surgical outcomes of 10 patients with defects of the glenoid cavity who underwent reverse total shoulder arthroplasty using individual glenoid base plates. The average follow-up period postsurgery was (2.6 ± 1.6) years. The mean age of the patients was (62.4 ± 5.6) years, including 7 women (70 %) and 3 men (30 %). Two patients (one woman and one man) underwent RTSA on both shoulders, resulting in a total of 12 RTSA procedures performed on 10 patients. All patients underwent shoulder joint imaging using spiral computed tomography, modeling of the individual base plate implant for the glenoid part of the endoprosthesis, and fabrication of the implant using 3D printing with titanium powder. The function of the shoulder joint was evaluated using the Constant-Murley Shoulder Score (CMS). Results. The mean cortical index was 0.38 ± 0.06. Lateralization and distalization angles were measured at 80° ± 5.6° and 55° ± 8.2°, respectively. The average active range of motion for external rotation was 60° ± 5.5°, flexion and elevation of the upper limb at the shoulder joint (including the scapula) was 135° ± 8.4°, internal rotation was 85° ± 3.4°, and abduction of the shoulder joint (including the scapula) was 145° ± 10.2°. The mean score on the CMS scale was 85. Conclusion. The retrospective analysis demonstrates a significant reduction or complete absence of pain syndrome along with improved functional outcomes in patients after RTSA with glenoid cavity defects when using custom base plates for the glenoid part of the reverse shoulder endoprosthesis.
- Open Access
- 20 June 2025
- Published by Danylo Halytskyi Lviv National Medical University in Proceeding of the Shevchenko Scientific Society. Medical Sciences
- Vol. 77 (1)
SHORT-TERM OUTCOMES OF REVERSE SHOULDER ARTHROPLASTY
Introduction. Recent studies highlight the growing concern regarding the increasing number of proximal humerus fractures, the severity of which escalates with age due to the progressive decline in bone mineral density. Recommendations from the European Society for Trauma and Emergency Surgery emphasize a growing trend toward reverse shoulder arthroplasty in elderly patients. Objective. To analyze the short-term functional outcomes of implementing an original modular reverse total shoulder prosthesis in the surgical treatment of patients with proximal humerus fractures or their sequelae in the context of reduced bone mineral density. Methods. A prospective study was conducted on a group of 14 patients who met the following inclusion criteria: age ≥ 50 years; proximal humerus fracture type 11-B or 11-C according to AO/OTA classification; significantly reduced bone mineral density with a cortical index ≤ 0.4. Surgical intervention was performed using an original modular reverse total shoulder prosthesis based on additive manufacturing technologies. Shoulder joint function was evaluated using the Constant-Murley Shoulder Score at 3, 6, and 12 months postoperatively. Differences in functional outcomes were assessed using Tukey’s test at a significance level of p < 0.05 based on one-way analysis of variance. Results. The mean age of patients was (65.0 ± 7.8) years. All patients had significantly reduced bone mineral density, and more than half (8 individuals, 57.1%) had a cortical index in the range of 0.30–0.38. The mean time from injury to surgery was (82.3 ± 70.5) days. The developed modular prosthesis was used in patients with substantial proximal humerus defects on the background of reduced bone mineral density, as well as following failed open reduction and internal fixation. Conclusions. A statistically significant (p < 0.05) improvement in the functional outcomes of patients in the study group at 12 months postoperatively confirmed the feasibility of using a porous titanium modular reverse shoulder prosthesis manufactured with additive 3D technologies in type 11-B and 11-C fractures with reduced bone mineral density in patients over 50 years of age with proximal humerus defects. The complication rate of 28.6% in the study group did not exceed the average values reported in comparable studies by other authors.
- 20 June 2025
- Published by Danylo Halytskyi Lviv National Medical University in Proceeding of the Shevchenko Scientific Society. Medical Sciences
- Vol. 77 (1)
Open AccessSHORT-TERM OUTCOMES OF REVERSE SHOULDER ARTHROPLASTY
Introduction. Recent studies highlight the growing concern regarding the increasing number of proximal humerus fractures, the severity of which escalates with age due to the progressive decline in bone mineral density. Recommendations from the European Society for Trauma and Emergency Surgery emphasize a growing trend toward reverse shoulder arthroplasty in elderly patients. Objective. To analyze the short-term functional outcomes of implementing an original modular reverse total shoulder prosthesis in the surgical treatment of patients with proximal humerus fractures or their sequelae in the context of reduced bone mineral density. Methods. A prospective study was conducted on a group of 14 patients who met the following inclusion criteria: age ≥ 50 years; proximal humerus fracture type 11-B or 11-C according to AO/OTA classification; significantly reduced bone mineral density with a cortical index ≤ 0.4. Surgical intervention was performed using an original modular reverse total shoulder prosthesis based on additive manufacturing technologies. Shoulder joint function was evaluated using the Constant-Murley Shoulder Score at 3, 6, and 12 months postoperatively. Differences in functional outcomes were assessed using Tukey’s test at a significance level of p < 0.05 based on one-way analysis of variance. Results. The mean age of patients was (65.0 ± 7.8) years. All patients had significantly reduced bone mineral density, and more than half (8 individuals, 57.1%) had a cortical index in the range of 0.30–0.38. The mean time from injury to surgery was (82.3 ± 70.5) days. The developed modular prosthesis was used in patients with substantial proximal humerus defects on the background of reduced bone mineral density, as well as following failed open reduction and internal fixation. Conclusions. A statistically significant (p < 0.05) improvement in the functional outcomes of patients in the study group at 12 months postoperatively confirmed the feasibility of using a porous titanium modular reverse shoulder prosthesis manufactured with additive 3D technologies in type 11-B and 11-C fractures with reduced bone mineral density in patients over 50 years of age with proximal humerus defects. The complication rate of 28.6% in the study group did not exceed the average values reported in comparable studies by other authors.
- Open Access
- 2 April 2025
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 1,p. 37-44
ANALYSIS OF POSTOPERATIVE COMPLICATIONS IN THE SURGICAL TREATMENT OF PROXIMAL HUMERAL FRACTURES IN PATIENTS WITH DECREASED MINERAL BONE DENSITY
Objective. To conduct a comparative retrospective analysis of the impact of postoperative complications on functional outcomes following different surgical treatment methods for proximal humeral fractures of AO/OTA types 11-B and 11-C in patients over 45 years old with decreased bone mineral density. Methods. The study analyzed the surgical treatment outcomes and postoperative complications in 102 patients aged (61.1 ± 8.1) years, who were divided into three groups based on the treatment method: (1) open reduction and internal fixation (ORIF) using a PHILOS plate (n = 50); (2) ORIF with a PHILOS plate combined with 3D-printed PLA implants (n = 44); (3) primary reverse total shoulder arthroplasty (RTSA) using a newly developed total reverse endoprosthesis (n = 8). Functional outcomes in patients with complications were assessed using the Constant-Murley Score at 3, 6, and 12 months postoperatively and analyzed based on individual preoperative parameters and treatment methods. Results. A total of 30 postoperative complications were recorded, the most common being superficial infection (7.8 % of the total population), secondary displacement (6.9 %), varus malalignment of fragments (6.9 %), and avascular necrosis of the humeral head (3.9 %). The highest number of complications was observed in Group (1), with 19 patients affected, accounting for 38 % . For all complications except avascular necrosis, a significant improvement in functional outcomes was observed between 3 and 12 months postoperatively. The mean Constant-Murley Score in patients with complications at 12 months postoperatively was (78.7 ± 8.5). Conclusions A retrospective analysis of postoperative complications following different surgical treatment methods established that, compared to other options, reverse total shoulder arthroplasty (RTSA) is a modern and optimal surgical treatment option for proximal humeral fractures of AO/OTA types 11-B or 11-C in the context of severe bone mineral density reduction, particularly in elderly patients.
- 2 April 2025
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 1,p. 37-44
Open AccessANALYSIS OF POSTOPERATIVE COMPLICATIONS IN THE SURGICAL TREATMENT OF PROXIMAL HUMERAL FRACTURES IN PATIENTS WITH DECREASED MINERAL BONE DENSITY
Objective. To conduct a comparative retrospective analysis of the impact of postoperative complications on functional outcomes following different surgical treatment methods for proximal humeral fractures of AO/OTA types 11-B and 11-C in patients over 45 years old with decreased bone mineral density. Methods. The study analyzed the surgical treatment outcomes and postoperative complications in 102 patients aged (61.1 ± 8.1) years, who were divided into three groups based on the treatment method: (1) open reduction and internal fixation (ORIF) using a PHILOS plate (n = 50); (2) ORIF with a PHILOS plate combined with 3D-printed PLA implants (n = 44); (3) primary reverse total shoulder arthroplasty (RTSA) using a newly developed total reverse endoprosthesis (n = 8). Functional outcomes in patients with complications were assessed using the Constant-Murley Score at 3, 6, and 12 months postoperatively and analyzed based on individual preoperative parameters and treatment methods. Results. A total of 30 postoperative complications were recorded, the most common being superficial infection (7.8 % of the total population), secondary displacement (6.9 %), varus malalignment of fragments (6.9 %), and avascular necrosis of the humeral head (3.9 %). The highest number of complications was observed in Group (1), with 19 patients affected, accounting for 38 % . For all complications except avascular necrosis, a significant improvement in functional outcomes was observed between 3 and 12 months postoperatively. The mean Constant-Murley Score in patients with complications at 12 months postoperatively was (78.7 ± 8.5). Conclusions A retrospective analysis of postoperative complications following different surgical treatment methods established that, compared to other options, reverse total shoulder arthroplasty (RTSA) is a modern and optimal surgical treatment option for proximal humeral fractures of AO/OTA types 11-B or 11-C in the context of severe bone mineral density reduction, particularly in elderly patients.
- Open Access
- 18 October 2023
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 3,p. 36-42
FINITE ELEMENT ANALYSIS OF THE STRESS-STRAIN STATE OF 3D COMPUTER GENERATED IMAGING OF REVERSE TOTAL SHOULDER ENDOPROSTHESES
Objective. To conduct a finite element analysis of the stress-strain state (STS) of the elements of the shoulder joint after implantation reverse shoulder endoprostheses. Material and methods. After 3Dscanning of the composite model of the scapula and humerus, geometric models of the shoulder joint were built in the SolidWorks 2019 SP 1.0 program, followed by mathematical modeling and FEA. For the comparative analysis of the STS of the «bone – reverse endoprosthesis» s ystem, t hree-dimensional m odels o f two types of reverse shoulder endoprostheses were created, which were then transformed into a finite-element model and implanted into the developed three-dimensional mathematical model of the shoulder joint without cement. The STS calculations of the elements of endoprostheses were carried out for two positions: abduction 90° and flexion 90° with a load of 5 kg. Results. Compared to the healthy shoulder joint, models with reverse shoulder endoprosthesis have significantly different contact stresses and contact areas. It was established that the maximum stress in the details of the contact parts of the endoprosthesis when retracted at an angle of 90° did not exceed +1.78 MPa, when bending +5.8 MPa. The maximum stresses on the liner during shoulder abduction are +8.6 MPa, the minimum –7.38 MPa, during flexion +2.3 MPa and –2.45 MPa, respectively. It has been proven that the contact areas of the hemisphere and inserts of both reverse endoprostheses during abduction and flexion of the limb by 90° are significantly larger (573 mm2 vs. 1809–2081 mm2) when compared with a healthy shoulder joint, while changes in the area between the endoprostheses are insignificant and equal to 2...3 %. Conclusions. Analysis of the STS load of elements of reverse shoulder endoprosthesis showed that the greatest stresses occur in the contact zones. It has been proven that the maximum stresses on the contact structures of endoprostheses are less than on the head of a healthy joint, but the contact area during implantation of a reversible endoprosthesis of the shoulder joint increases significantly (more than 3 times).
- 18 October 2023
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 3,p. 36-42
Open AccessFINITE ELEMENT ANALYSIS OF THE STRESS-STRAIN STATE OF 3D COMPUTER GENERATED IMAGING OF REVERSE TOTAL SHOULDER ENDOPROSTHESES
Objective. To conduct a finite element analysis of the stress-strain state (STS) of the elements of the shoulder joint after implantation reverse shoulder endoprostheses. Material and methods. After 3Dscanning of the composite model of the scapula and humerus, geometric models of the shoulder joint were built in the SolidWorks 2019 SP 1.0 program, followed by mathematical modeling and FEA. For the comparative analysis of the STS of the «bone – reverse endoprosthesis» s ystem, t hree-dimensional m odels o f two types of reverse shoulder endoprostheses were created, which were then transformed into a finite-element model and implanted into the developed three-dimensional mathematical model of the shoulder joint without cement. The STS calculations of the elements of endoprostheses were carried out for two positions: abduction 90° and flexion 90° with a load of 5 kg. Results. Compared to the healthy shoulder joint, models with reverse shoulder endoprosthesis have significantly different contact stresses and contact areas. It was established that the maximum stress in the details of the contact parts of the endoprosthesis when retracted at an angle of 90° did not exceed +1.78 MPa, when bending +5.8 MPa. The maximum stresses on the liner during shoulder abduction are +8.6 MPa, the minimum –7.38 MPa, during flexion +2.3 MPa and –2.45 MPa, respectively. It has been proven that the contact areas of the hemisphere and inserts of both reverse endoprostheses during abduction and flexion of the limb by 90° are significantly larger (573 mm2 vs. 1809–2081 mm2) when compared with a healthy shoulder joint, while changes in the area between the endoprostheses are insignificant and equal to 2...3 %. Conclusions. Analysis of the STS load of elements of reverse shoulder endoprosthesis showed that the greatest stresses occur in the contact zones. It has been proven that the maximum stresses on the contact structures of endoprostheses are less than on the head of a healthy joint, but the contact area during implantation of a reversible endoprosthesis of the shoulder joint increases significantly (more than 3 times).
- Open Access
- 12 June 2023
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 1,p. 86-99
SURGICAL TREATMENT OF THE PROXIMAL HUMERUS FRACTURES IN PATIENTS WITH OSTEOPOROSIS. PROBLEMATIC ISSUES AND DEVELOPMENT PROSPECTS
Fractures of the proximal part of the humerus (FPPH) are the third most common in the elderly after fractures of the femur and radius. Objective. On the basis of analysis of the literature to identify problematic issues of surgical treatment of patients with FPPH and osteoporosis and prospects for improving implants and algorithms treatment. Methods. The material of the study was the scientific papers available in Google search engines, PubMed,Medline, published in specialized sources. Results. It is shown that are used today there are Neer and AO/OTA classifications of FPPH. Conservatively manage of FPPH in 80 % of patients with two-fragmentary fractures according to Neer or type A2/A3 according to AO/OTA. The remaining 20 % patients have threeand four-segment FPPH (types B and C according to AO/OTA), the conservative treatment of which consists of problem, especiallyin patients with osteopenia and osteoporosis. Surgical treatment of FPPH is recommended in case of fractures types 11B2-3, 11C2-3 in young patients or in the elderly age that requires significantfunctionality of the upper extremity. Positive results of treatment of FPPH types 11B3, 11C2-3 on the background of osteoporosis obtained after installation LCP-plates with allo- or autograftfrom the fibula bones, as well as support screws, filling of cavities in the humerus head fragments with bone cement, or using free bone implants are most often used. These methods achieve andsupport to enable stable repositioning of even complex type fractures 11C2-3. Blocked intramedullary nails of the third generationhave improved mechanisms for attaching proximal screws and specific fixation of bone fragments, as well as straight geometry. Primary reverse shoulder arthroplasty in case of type 11С2, 11С3fractures according to AO/OTA enables to obtain positive results in most patients. Conclusions. Surgical treatment of patients with FPPH is advisable for active patients, it is possible to improvefunctional results compared to conservative manage and avoid the most complications of it.
- 12 June 2023
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 1,p. 86-99
Open AccessSURGICAL TREATMENT OF THE PROXIMAL HUMERUS FRACTURES IN PATIENTS WITH OSTEOPOROSIS. PROBLEMATIC ISSUES AND DEVELOPMENT PROSPECTS
Fractures of the proximal part of the humerus (FPPH) are the third most common in the elderly after fractures of the femur and radius. Objective. On the basis of analysis of the literature to identify problematic issues of surgical treatment of patients with FPPH and osteoporosis and prospects for improving implants and algorithms treatment. Methods. The material of the study was the scientific papers available in Google search engines, PubMed,Medline, published in specialized sources. Results. It is shown that are used today there are Neer and AO/OTA classifications of FPPH. Conservatively manage of FPPH in 80 % of patients with two-fragmentary fractures according to Neer or type A2/A3 according to AO/OTA. The remaining 20 % patients have threeand four-segment FPPH (types B and C according to AO/OTA), the conservative treatment of which consists of problem, especiallyin patients with osteopenia and osteoporosis. Surgical treatment of FPPH is recommended in case of fractures types 11B2-3, 11C2-3 in young patients or in the elderly age that requires significantfunctionality of the upper extremity. Positive results of treatment of FPPH types 11B3, 11C2-3 on the background of osteoporosis obtained after installation LCP-plates with allo- or autograftfrom the fibula bones, as well as support screws, filling of cavities in the humerus head fragments with bone cement, or using free bone implants are most often used. These methods achieve andsupport to enable stable repositioning of even complex type fractures 11C2-3. Blocked intramedullary nails of the third generationhave improved mechanisms for attaching proximal screws and specific fixation of bone fragments, as well as straight geometry. Primary reverse shoulder arthroplasty in case of type 11С2, 11С3fractures according to AO/OTA enables to obtain positive results in most patients. Conclusions. Surgical treatment of patients with FPPH is advisable for active patients, it is possible to improvefunctional results compared to conservative manage and avoid the most complications of it.
- Open Access
- 26 May 2023
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 3-4,p. 13-21
Results of a differential approach to surgical treatment of proximal humerus fractures in patients with osteoporosis
Objective. To conduct a comparative retrospective analysis of the anatomical and functional results of surgical treatment of proximal humerus fractures AO/OTA 11-B, 11-C using different methods in patients over 50 years old with osteoporosis to justify a differential approach. Methods. The study included 102 patients aged 50 years and older with osteoporosis and proximal humerus fractures AO/OTA 11-B, 11-C. The patients were divided into three groups: I — 50 (16 men, 34 women) whom were performed open reduction and internal fixation (ORIF) with the PHILOS plate; II — 44 (8 men, 36 women) — ORIF with the PHILOS plate and using 3D polylactide (PLA) porous implants were applied; III — 8 (2 men, 6 women) whom were performed primary reversed total shoulder arthroplasty (RTSA) with developed total reversible endoprosthesis. The results of treatment were evaluated according to the Constant-Murley Shoulder Score system after 3, 6, 12 months. The results. Positive results in the first group were obtained in 72.0 % of patients (the average Constant-Murley Shoulder Score after 12 months was 78.4 points); in the second — in 81.8 % (88.0 points); in the third — 75.0 % (82.0 points). A differentiated approach to the choice of surgical treatment of patients aged 50 years and older with fractures AO/OTA 11-B, 11-C is proposed. The clinical trial of the reverse total modular shoulder endoprosthesis developed by us using porous 3D titanium parts, manufactured by additive technologies, showed positive short-term results. The design features of the device increase the reliability and durability of proposed endoprosthesis. Conclusions. RTSA in the case of unstable proximal humerus fracture or in the case of metal structure migration after primary ORIF in patients with low bone mineral density is the effective surgical intervention that allows to achieve satisfactory functional results in up to 3 years.
- 26 May 2023
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 3-4,p. 13-21
Open AccessResults of a differential approach to surgical treatment of proximal humerus fractures in patients with osteoporosis
Objective. To conduct a comparative retrospective analysis of the anatomical and functional results of surgical treatment of proximal humerus fractures AO/OTA 11-B, 11-C using different methods in patients over 50 years old with osteoporosis to justify a differential approach. Methods. The study included 102 patients aged 50 years and older with osteoporosis and proximal humerus fractures AO/OTA 11-B, 11-C. The patients were divided into three groups: I — 50 (16 men, 34 women) whom were performed open reduction and internal fixation (ORIF) with the PHILOS plate; II — 44 (8 men, 36 women) — ORIF with the PHILOS plate and using 3D polylactide (PLA) porous implants were applied; III — 8 (2 men, 6 women) whom were performed primary reversed total shoulder arthroplasty (RTSA) with developed total reversible endoprosthesis. The results of treatment were evaluated according to the Constant-Murley Shoulder Score system after 3, 6, 12 months. The results. Positive results in the first group were obtained in 72.0 % of patients (the average Constant-Murley Shoulder Score after 12 months was 78.4 points); in the second — in 81.8 % (88.0 points); in the third — 75.0 % (82.0 points). A differentiated approach to the choice of surgical treatment of patients aged 50 years and older with fractures AO/OTA 11-B, 11-C is proposed. The clinical trial of the reverse total modular shoulder endoprosthesis developed by us using porous 3D titanium parts, manufactured by additive technologies, showed positive short-term results. The design features of the device increase the reliability and durability of proposed endoprosthesis. Conclusions. RTSA in the case of unstable proximal humerus fracture or in the case of metal structure migration after primary ORIF in patients with low bone mineral density is the effective surgical intervention that allows to achieve satisfactory functional results in up to 3 years.
- Open Access
- 5 October 2021
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 1,p. 51-61
Morphometry of the shoulder joint and justification of new modular reverse shoulder endoprosthesis sizes using computed tomography data
Reverse shoulder arthroplasty is effective surgery because most of patients have positive long-term results. However, the search for the «perfect» endoprosthesis continues. Objective. To justify the dimensions of a new modular reverse shoulder endoprosthesis using additive technologies based on spiral computed tomography data. Methods. Two data sets of healthy shoulder joints (right — R, left — L) of 100 patients obtained on a spiral computed tomography AQUILION 128 sections (Toshiba, Japan) were processed. Each set consisted of 11 morphometric parameters — linear and angular values. For each of them, three data samples (combined, R and L) are calculated: minimum, maximum, mode, median, mean, standard deviation, distribution asymmetry coefficient. Pearson’s correlation coefficient was calculated, cluster analysis was performed. Results. It is proved that most of the parameters of R and L data sets can be considered homogeneous and can be analyzed as a combined group of 200 cases. It was found that the width and height of the glenoid are more homogeneous data sets, and the value of the endosteal diameter of the humerus decreases in the distal direction. The cervical-diaphyseal angle averages 137.4° ± 4.66°. The correlation between different parameters is more pronounced within most clusters than in the sample as a whole. Conclusions. It is necessary to create different sizes of the distal part of the conical stem, to which securely fix a wide proximal part, as well as in different sizes, in the form of a cup for fixing the liner. The height of the proximal part of the reverse shoulder endoprosthesis should be not less than 20 mm, the diameter of the base of the proximal parts of the stem — 38, 40, 42 mm. It is proposed to use a conical stem of the implant with a wider proximal part, to create the angle 135° between the cup of the proximal part and the stem. Three standard sizes of basic glenoid plates with a diameter of 26, 30, 32 mm are defined. Key words. 3D-printing, arthroplasty of the shoulder joint, glenoid, cluster analysis, correlation analysis.
- 5 October 2021
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 1,p. 51-61
Open AccessMorphometry of the shoulder joint and justification of new modular reverse shoulder endoprosthesis sizes using computed tomography data
Reverse shoulder arthroplasty is effective surgery because most of patients have positive long-term results. However, the search for the «perfect» endoprosthesis continues. Objective. To justify the dimensions of a new modular reverse shoulder endoprosthesis using additive technologies based on spiral computed tomography data. Methods. Two data sets of healthy shoulder joints (right — R, left — L) of 100 patients obtained on a spiral computed tomography AQUILION 128 sections (Toshiba, Japan) were processed. Each set consisted of 11 morphometric parameters — linear and angular values. For each of them, three data samples (combined, R and L) are calculated: minimum, maximum, mode, median, mean, standard deviation, distribution asymmetry coefficient. Pearson’s correlation coefficient was calculated, cluster analysis was performed. Results. It is proved that most of the parameters of R and L data sets can be considered homogeneous and can be analyzed as a combined group of 200 cases. It was found that the width and height of the glenoid are more homogeneous data sets, and the value of the endosteal diameter of the humerus decreases in the distal direction. The cervical-diaphyseal angle averages 137.4° ± 4.66°. The correlation between different parameters is more pronounced within most clusters than in the sample as a whole. Conclusions. It is necessary to create different sizes of the distal part of the conical stem, to which securely fix a wide proximal part, as well as in different sizes, in the form of a cup for fixing the liner. The height of the proximal part of the reverse shoulder endoprosthesis should be not less than 20 mm, the diameter of the base of the proximal parts of the stem — 38, 40, 42 mm. It is proposed to use a conical stem of the implant with a wider proximal part, to create the angle 135° between the cup of the proximal part and the stem. Three standard sizes of basic glenoid plates with a diameter of 26, 30, 32 mm are defined. Key words. 3D-printing, arthroplasty of the shoulder joint, glenoid, cluster analysis, correlation analysis.
- 24 December 2020
- Published by Vitebsk State Medical University in Novosti Khirurgii
- Vol. 28 (6) , 617-624
Osseointegration of Implants with A Diamond-Like Carbon Coating in the Experiment
Цель. Изучить в эксперименте на крысах интеграцию с костью металлических имплантатов из нержавеющей стали с алмазоподобным углеродным (DLC) покрытием. Материал и методы. Эксперимент проведен на 48 белых крысах-самцах в возрасте 6 месяцев. Животным имплантировали в метафизарные дефекты бедренной кости (диаметр 2 мм и глубина 3 мм) имплантаты из стали и стальные имплантаты с DLC-покрытием (по 24 крысы в контрольной и опытной группах). На поверхность стального имплантата наносили DLC-покрытие из отфильтрованных потоков вакуумно-дуговой плазмы. Материал покрытия не содержал примесей металлов и водорода. Нанотвердость нанесенного на образец покрытия составляла от 30 до 40 ГПа. Толщина DLC-покрытия составляла не менее 1 мкм. Эвтаназию крыс проводили через 7, 14, 30 и 90 дней после операции путем введения летальной дозы тиопентала натрия (90 мг/кг внутримышечно). Ремоделирование кости вокруг имплантатов исследовали гистологическими методами с морфометрической оценкой остеоинтеграции (контакт костной ткани с имплантатом в процентах). Результаты. Алмазоподобное углеродное покрытие на стальных имплантатах обладает высокими адгезионными качествами, о чем свидетельствует прикрепление клеток к поверхности в течение 7 дней после имплантации и формирование вокруг них костной ткани через 14 дней. Вокруг стальных имплантатов зафиксировано образование прослойки из соединительной ткани с участками костной ткани. Выявлено, что за весь период исследования вокруг имплантатов из стали с DLC-покрытием процент остеоинтеграции был выше по сравнению с имплантатами без покрытия: на 14-й день – в 2,6 раза, на 30-й день – в 2,1 раза, на 90-й день – в 1,5 раза. Заключение. Алмазоподобные углеродные покрытия на стальных имплантатах являются перспективным материалом для использования в ортопедии и травматологии благодаря биосовместимости, остеоинтеграции и отсутствию негативного ремоделирования прилегающей костной ткани. Научная новизна статьи Впервые в эксперименте изучена перестройка кости вокруг имплантатов с разработанным алмазоподобным углеродным покрытием. Установлено, что использованное покрытие обладает биосовместимостью и высокими показателями остеоинтеграции.
- 24 December 2020
- Published by Vitebsk State Medical University in Novosti Khirurgii
- Vol. 28 (6) , 617-624
Osseointegration of Implants with A Diamond-Like Carbon Coating in the Experiment
Цель. Изучить в эксперименте на крысах интеграцию с костью металлических имплантатов из нержавеющей стали с алмазоподобным углеродным (DLC) покрытием. Материал и методы. Эксперимент проведен на 48 белых крысах-самцах в возрасте 6 месяцев. Животным имплантировали в метафизарные дефекты бедренной кости (диаметр 2 мм и глубина 3 мм) имплантаты из стали и стальные имплантаты с DLC-покрытием (по 24 крысы в контрольной и опытной группах). На поверхность стального имплантата наносили DLC-покрытие из отфильтрованных потоков вакуумно-дуговой плазмы. Материал покрытия не содержал примесей металлов и водорода. Нанотвердость нанесенного на образец покрытия составляла от 30 до 40 ГПа. Толщина DLC-покрытия составляла не менее 1 мкм. Эвтаназию крыс проводили через 7, 14, 30 и 90 дней после операции путем введения летальной дозы тиопентала натрия (90 мг/кг внутримышечно). Ремоделирование кости вокруг имплантатов исследовали гистологическими методами с морфометрической оценкой остеоинтеграции (контакт костной ткани с имплантатом в процентах). Результаты. Алмазоподобное углеродное покрытие на стальных имплантатах обладает высокими адгезионными качествами, о чем свидетельствует прикрепление клеток к поверхности в течение 7 дней после имплантации и формирование вокруг них костной ткани через 14 дней. Вокруг стальных имплантатов зафиксировано образование прослойки из соединительной ткани с участками костной ткани. Выявлено, что за весь период исследования вокруг имплантатов из стали с DLC-покрытием процент остеоинтеграции был выше по сравнению с имплантатами без покрытия: на 14-й день – в 2,6 раза, на 30-й день – в 2,1 раза, на 90-й день – в 1,5 раза. Заключение. Алмазоподобные углеродные покрытия на стальных имплантатах являются перспективным материалом для использования в ортопедии и травматологии благодаря биосовместимости, остеоинтеграции и отсутствию негативного ремоделирования прилегающей костной ткани. Научная новизна статьи Впервые в эксперименте изучена перестройка кости вокруг имплантатов с разработанным алмазоподобным углеродным покрытием. Установлено, что использованное покрытие обладает биосовместимостью и высокими показателями остеоинтеграции.
- Open Access
- 27 October 2020
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 3,p. 44-53
The results of open reduction and plate fixation with angular stability of the proximal humerus fractures in patients with osteoporosis
Objective: a retrospective study of anatomical and functional results of open reduction and plate osteosynthesis in patients older than 50 years with of the proximal humerus fractures type AO/OTA 11-B, 11-C and osteoporosis, who were treated with plate PHILOS taking into account the surgical treatment of adverse results with reverse total shoulder arthroplasty (RTSA). Methods: we analyzed case histories of 58 patients (age older 50 years) with osteoporosis and three- and four-fragment fractures of the proximal umerus according to the Neer classification (type AO/OTA 11-B, 11-C). In group I — 20 patients (age from 50 to 76 years, 8 men and 12 women) — we made open reduction, ORIF with plate PHILOS; II — 38 patients (aged 54 to 78 years, all women) — had surgeries ORIF with PHILOS plate and 3D polylactide implants. Results: according to the Constant Murley Shoulder Score system in 11 (55 %) patients of group I excellent and good results were obtained, in 5 (25 %) — satisfactory, in 4 cases (20%) are unsatisfactory. At the last cases we made RTSA in terms from 6 to 12 months after the primary surgery, one of them had revision RTSA due to fracture of the humeral shaft and instability of the stem implant. According to the Constant Murley Shoulder Score system, the average score after 12 months in group I was 78, in II — 87. No signs of avascular necrosis of the humeral head were observed. Conclusions: the use of PHILOS plates with additional reinforcement with 3D polylactide implants allowed us to obtain positive results in 34 (89.5 %) patients after 6–12 months after the surgery with a lower complications rate compare to known techniques. If ORIF method gives an unfavorable result then RTSA gives the possibility to achieve positive results within 3 years after the surgery.
- 27 October 2020
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 3,p. 44-53
Open AccessThe results of open reduction and plate fixation with angular stability of the proximal humerus fractures in patients with osteoporosis
Objective: a retrospective study of anatomical and functional results of open reduction and plate osteosynthesis in patients older than 50 years with of the proximal humerus fractures type AO/OTA 11-B, 11-C and osteoporosis, who were treated with plate PHILOS taking into account the surgical treatment of adverse results with reverse total shoulder arthroplasty (RTSA). Methods: we analyzed case histories of 58 patients (age older 50 years) with osteoporosis and three- and four-fragment fractures of the proximal umerus according to the Neer classification (type AO/OTA 11-B, 11-C). In group I — 20 patients (age from 50 to 76 years, 8 men and 12 women) — we made open reduction, ORIF with plate PHILOS; II — 38 patients (aged 54 to 78 years, all women) — had surgeries ORIF with PHILOS plate and 3D polylactide implants. Results: according to the Constant Murley Shoulder Score system in 11 (55 %) patients of group I excellent and good results were obtained, in 5 (25 %) — satisfactory, in 4 cases (20%) are unsatisfactory. At the last cases we made RTSA in terms from 6 to 12 months after the primary surgery, one of them had revision RTSA due to fracture of the humeral shaft and instability of the stem implant. According to the Constant Murley Shoulder Score system, the average score after 12 months in group I was 78, in II — 87. No signs of avascular necrosis of the humeral head were observed. Conclusions: the use of PHILOS plates with additional reinforcement with 3D polylactide implants allowed us to obtain positive results in 34 (89.5 %) patients after 6–12 months after the surgery with a lower complications rate compare to known techniques. If ORIF method gives an unfavorable result then RTSA gives the possibility to achieve positive results within 3 years after the surgery.
- Open Access
- 29 January 2020
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 4,p. 26-36
The results of clinical trial with polylactide implants for osteosynthesis of proximal humerus fractures in patients with osteoporosis
Proximal humerus fractures (AO/OTA 11) occur in 5–6 % of the trauma structure and most often are in people older than 50 years. There is no currently existing universally accepted approach to the treatment of proximal humerus fractures with osteoporosis. Objective: to analyze the results of surgical treatment of patients with multifragments proximal humerus fractures and osteoporosis using PHILOS type plate and polylactide implants. Methods: 38 women with osteoporosis were made surgeries with PHILOS and polylactide implants; their age was from 54 to 78 years, at the period 2015–2019. 32 patients had three-fragment proximal humerus fracture by Neer (AO/OTA 11-B), 6 — four-fragment (AO/OTA 11-C). The results were evaluated by Constant-Murley Shoulder Score in 3, 6, 12 and 24 months after surgery. Results: there was fracture healing in all patients. We did not observe any avascular head necrosis. The average score by Constant-Murley Shoulder Score after 3, 6, 12 and 24 months after surgery was equal to 78.2; 82.1; 87.2 and 87.2 points, respectively. One patient had a perforation by screw; two patients had a superficial infection that was eliminated with antibacterial therapy. There was a secondary displacement of small tubercle of the humeral head up to 8–10 mm in one patient after 3 months without any harm to shoulder joint function. Conclusions. PHILOS plates with reinforcement of polylactide implants allowed to achieve 89.5 % positive results in the period from 6 to 24 months after the surgery in patients with multifragments proximal humerus fractures and osteoporosis. There is low level of complications comparing with other available methods (mean score for Constant-Murley Shoulder Score 87.2).
- 29 January 2020
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 4,p. 26-36
Open AccessThe results of clinical trial with polylactide implants for osteosynthesis of proximal humerus fractures in patients with osteoporosis
Proximal humerus fractures (AO/OTA 11) occur in 5–6 % of the trauma structure and most often are in people older than 50 years. There is no currently existing universally accepted approach to the treatment of proximal humerus fractures with osteoporosis. Objective: to analyze the results of surgical treatment of patients with multifragments proximal humerus fractures and osteoporosis using PHILOS type plate and polylactide implants. Methods: 38 women with osteoporosis were made surgeries with PHILOS and polylactide implants; their age was from 54 to 78 years, at the period 2015–2019. 32 patients had three-fragment proximal humerus fracture by Neer (AO/OTA 11-B), 6 — four-fragment (AO/OTA 11-C). The results were evaluated by Constant-Murley Shoulder Score in 3, 6, 12 and 24 months after surgery. Results: there was fracture healing in all patients. We did not observe any avascular head necrosis. The average score by Constant-Murley Shoulder Score after 3, 6, 12 and 24 months after surgery was equal to 78.2; 82.1; 87.2 and 87.2 points, respectively. One patient had a perforation by screw; two patients had a superficial infection that was eliminated with antibacterial therapy. There was a secondary displacement of small tubercle of the humeral head up to 8–10 mm in one patient after 3 months without any harm to shoulder joint function. Conclusions. PHILOS plates with reinforcement of polylactide implants allowed to achieve 89.5 % positive results in the period from 6 to 24 months after the surgery in patients with multifragments proximal humerus fractures and osteoporosis. There is low level of complications comparing with other available methods (mean score for Constant-Murley Shoulder Score 87.2).