Gleb Lazarenko
Gleb Lazarenko has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Igor Boyko3 shared publications
- Vasyl Makarov
КНП «Міська клінічна лікарня № 16» ДМР, Дніпро. Україна
3 shared publications Dmitriy Shcherbakov
2 shared publications- Alexander Sabsay1 shared publication
- Igor Maliy1 shared publication
Volodymyr Lipovskiy
1 shared publication
Latest Publications
- Open Access
- 23 January 2019
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 4,p. 115-121
Experimental study of stiffness fixation of a three-part fracture of the proximal humerus
Experimental study of stiffness fixation of a three-part fracture of the proximal humerus
- 23 January 2019
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 4,p. 115-121
Open AccessExperimental study of stiffness fixation of a three-part fracture of the proximal humerus
Experimental study of stiffness fixation of a three-part fracture of the proximal humerus
- Open Access
- 4 April 2018
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 1,p. 72-78
Radial head arthroplasty with bipolar uncemented endoprothesis with metal – metal bearing
Objective: to review technical peculiarities of designed uncemented modular radial head endoprothesis and to analyze it clinical application in patients with fractures and dislocations of the radial head ІІІ–IV types by Mason-Hotchkiss. Methods: we studied clinical application of modular uncemented bipolar endoprothesis with metal-on metal bearing in 14 patients, age 43–74 years old. The follow-up was 6–24 months. Indications for arthroplasty were multifragments fractures and fractures with dislocation of ІІІ–IV types by Mason-Hotchkiss. Efficacy of treatment was assessed by Mayo Elbow Performance Score. Results: flexion in elbow joint in average was 130° (from 110° to 140°), average value of extension deficit — 3,2° (from 0° tо 10°), pronation — 77,86° (from 70° tо 90°), supination — 76,07° (from 80° tо 70°), flexion/extension — 127° (from 100° tо 140°), prosupination movements— 153° (from 140° tо 170°). We compared the volume of movements in elbow joint of operated site with contra lateral joint in 12 months of follow-up. Positive correlative connection of increased volume of movements was observed. The signs of elbow joint instability and significant complications during follow-up period were not find. According to Mayo Elbow Performance Score there were excellent results — 7 patients, good — 5, satisfactory result — 2, average score was 88,5. Conclusion: application of the new designed modular uncemented bipolar radial head endoprothesis allowed us to obtain positive results in term of 2 years of follow-up.
- 4 April 2018
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 1,p. 72-78
Open AccessRadial head arthroplasty with bipolar uncemented endoprothesis with metal – metal bearing
Objective: to review technical peculiarities of designed uncemented modular radial head endoprothesis and to analyze it clinical application in patients with fractures and dislocations of the radial head ІІІ–IV types by Mason-Hotchkiss. Methods: we studied clinical application of modular uncemented bipolar endoprothesis with metal-on metal bearing in 14 patients, age 43–74 years old. The follow-up was 6–24 months. Indications for arthroplasty were multifragments fractures and fractures with dislocation of ІІІ–IV types by Mason-Hotchkiss. Efficacy of treatment was assessed by Mayo Elbow Performance Score. Results: flexion in elbow joint in average was 130° (from 110° to 140°), average value of extension deficit — 3,2° (from 0° tо 10°), pronation — 77,86° (from 70° tо 90°), supination — 76,07° (from 80° tо 70°), flexion/extension — 127° (from 100° tо 140°), prosupination movements— 153° (from 140° tо 170°). We compared the volume of movements in elbow joint of operated site with contra lateral joint in 12 months of follow-up. Positive correlative connection of increased volume of movements was observed. The signs of elbow joint instability and significant complications during follow-up period were not find. According to Mayo Elbow Performance Score there were excellent results — 7 patients, good — 5, satisfactory result — 2, average score was 88,5. Conclusion: application of the new designed modular uncemented bipolar radial head endoprothesis allowed us to obtain positive results in term of 2 years of follow-up.
- Open Access
- 2 January 2018
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 4,p. 90-98
Radial head replacement (literature review)
On the basis of the literature analysis, various variants of the radial head endoprostheses, which were used earlier and are now used in clinical practice, are considered: monobloc, individual monobloc, sectional modular monobloc, bipolar modular. The generally accepted classification of endoprostheses does not exist for the radial head — today they are distributed by design to monoblocal and bipolar. Monoblocal endoprosthesis can be either modular or sectional. Bipolar radial head endoprosthesis has joint between the implant head and the leg of the hinge node, an additional degree of freedom in which provides the maximum congruent location of the head of the endoprosthesis during flexsion, extension and rotation of the radius in the elbow joint. The biomechanical peculiarities of the functioning of different types of endoprostheses are determined, sort-term and long-term clinical results of their application are shown. The indications for radial head replacement are: the lack of technical ability to perform internal fixation of Mason-Hotchkiss types III and IV injuries, as well as in the case of additional destabilizing disorders of the capsule-ligamentous apparatus, Essex-Loprest type injury, and instability of the elbow and/or pain in the arm after radial head resection, its unsatisfactory osteosynthesis, tumors of the proximal radius. The authors claim that in case of use of metallic endoprostheses, the radial head restores the valgus stability of the elbow to the normal level. From the first radial head replacement has passed over than 75 years, and the search for an ideal endoprosthesis is relevant. Despite the large number of designs and types of endoprosthesis, there is currently no implant that works as a natural radial head. All technological improvements are aimed at increasing the life of implants and minimizing injuries to the cartilage and soft tissues both during installation and in the process of work.
- 2 January 2018
- Published by Orthopaedica, Traumatology, and Prosthetics in ORTHOPAEDICS TRAUMATOLOGY and PROSTHETICS
- No. 4,p. 90-98
Open AccessRadial head replacement (literature review)
On the basis of the literature analysis, various variants of the radial head endoprostheses, which were used earlier and are now used in clinical practice, are considered: monobloc, individual monobloc, sectional modular monobloc, bipolar modular. The generally accepted classification of endoprostheses does not exist for the radial head — today they are distributed by design to monoblocal and bipolar. Monoblocal endoprosthesis can be either modular or sectional. Bipolar radial head endoprosthesis has joint between the implant head and the leg of the hinge node, an additional degree of freedom in which provides the maximum congruent location of the head of the endoprosthesis during flexsion, extension and rotation of the radius in the elbow joint. The biomechanical peculiarities of the functioning of different types of endoprostheses are determined, sort-term and long-term clinical results of their application are shown. The indications for radial head replacement are: the lack of technical ability to perform internal fixation of Mason-Hotchkiss types III and IV injuries, as well as in the case of additional destabilizing disorders of the capsule-ligamentous apparatus, Essex-Loprest type injury, and instability of the elbow and/or pain in the arm after radial head resection, its unsatisfactory osteosynthesis, tumors of the proximal radius. The authors claim that in case of use of metallic endoprostheses, the radial head restores the valgus stability of the elbow to the normal level. From the first radial head replacement has passed over than 75 years, and the search for an ideal endoprosthesis is relevant. Despite the large number of designs and types of endoprosthesis, there is currently no implant that works as a natural radial head. All technological improvements are aimed at increasing the life of implants and minimizing injuries to the cartilage and soft tissues both during installation and in the process of work.