RBRébecca Bonnaire

Rébecca Bonnaire

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Rébecca Bonnaire has a total of 29 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Caractérisation mécanique des orthèses : Application aux ceintures de soutien lombaire dans le cadre de la lombalgie

    by Rébecca Bonnaire

    La lombalgie est une douleur de la région lombaire du rachis. Un des moyens communément utilisés pour soulager cette douleur est le port d’orthèses lombaires. Bien que l’efficacité de ces orthèses soit démontrée, leur mode d’action reste mal connu. L’objectif de ce projet est d’analyser ce mode d’action dans le cas de ceintures de soutien lombaire.En lien avec des médecins et un industriel, trois approches ont été mises en œuvre. Premièrement, une approche expérimentale a permis de déterminer les propriétés mécaniques des ceintures de soutien lombaire et d’évaluer la pression appliquée suivant ces propriétés. Secondairement, la pression appliquée par les ceintures a été mesurée par une approche clinique. Cette pression a été liée à la diminution de la douleur engendrée par les ceintures, au bien-être ressenti, à la modification de la posture et à la déformation de la ceinture. Troisièmement, une approche numérique a servi à montrer les paramètres influents sur le soulagement de la douleur.Un des modes d’action des ceintures de soutien lombaire, mis en évidence dans ce projet, est la pression appliquée sur le tronc qui engendre une variation des pressions abdominale et intradiscale, ainsi qu’une modification de la posture. La pression appliquée dépend, entre autres, des caractéristiques mécaniques des ceintures. Les résultats mettent en évidence l’importance de maitriser cette pression appliquée ainsi que la spécificité du patient sur les effets mécaniques des ceintures.Les différentes approches sont complémentaires ; elles sont des moyens de caractérisation des orthèses qui pourraient être utilisés pour d’autres orthèses et également aider au développement de produits.

  • Reduced mechanical models of trunk–lumbar belt interaction for design-oriented in-silico clinical trials

    by Aicha Errabity, Fanette Chassagne, Paul Calmels, Woo-Suck Han, Romain Pannetier, Rébecca Bonnaire, Jérôme Molimard


  • Polypropylene/bis(benzoxazolyl)stilbene mechanochromic blends, an attractive feature for colorimetric strain detection

    by Céline Goni-Lizoain, Rébecca Bonnaire, Jean-Charles Fontanier, Etienne Copin, Rémi Gilblas, Carole Aubry-Meneveau, Pascal Rumeau, Yannick Le Maoult


  • Open Access

    Feasibility of a Full-Field Measurements-Based Protocol for the Biomechanical Study of a Lumbar Belt: A Case Study

    by Rébecca Bonnaire, Woo Suck Han, Reynald Convert, Paul Calmels, Jérôme Molimard

    Low back pain represents a major economic and societal challenge due to its high prevalence. Lumbar orthoses are one of the recommended treatments. Even if previous results showed their clinical effects, the detailed mode of action is still poorly known, making the device design difficult. A renewed instrumentation and experimental protocol should bring better insight into the lumbar brace–trunk mechanical interaction. This instrumentation should give detailed information on the basic physical or geometrical parameters: the pressure applied on the trunk, the body shape and the strain in the belt. The principal objective of this study was to propose and validate a new measurement protocol, based on pressure mapping systems and full-field shape and strain measurement. The feasibility of the protocol was tested along with its validity and repeatability. The influence of various parameters, which could cause changes in the measurements, was tested with six different belt configurations on one subject. Measurements were also performed to study the impact of posture on pressure and strain. Both pressure and strain appeared to be asymmetric from left to right. The pressure applied by the lumbar belt on the back varies with breathing and with posture. This study showed that full-field measurements were necessary to render the high variability of pressure or strain around the trunk, under recommendations of their use to guarantee a satisfying repeatability.

  • Speckle pattern creation methods for two‐dimensional digital image correlation strain measurements applied to mechanical tensile tests up to 700°C

    by Phuong Luong, Rébecca Bonnaire, Jean‐Noel Périé, Quentin Sirvin, Luc Penazzi

    The purpose of this study is to develop novel speckle pattern techniques for digital image correlation (DIC) kinematic measurements of mechanical tests at high temperatures, typically from 400 to 700°C. In this context, the speckle pattern should not only meet morphological criteria (size, density, distance) in order to improve spatial resolution, but it should also present a high contrast and resist high temperature and strain levels. To find a speckle pattern matching these specifications, a comparison was performed on six types of speckle made using different techniques. First, a computer‐generated speckle pattern that meets DIC criteria was numerically designed to produce six types of speckle pattern. Next, the speckle patterns produced using these six techniques were compared in terms of speckle morphology, image quality and adherence to titanium alloy TA6V material at high temperatures. From 25 to 600°C, the speckle pattern made by the technique combining anodisation and laser engraving named M5 technique gave the best contrast (highest value of mean intensity gradient [MIG] and Shannon entropy value) and the adherence of 200% of strain measurements to the TA6V material. At 700°C, speckle image quality is considerably reduced due to oxidation of the titanium alloy, and this may not be suitable for DIC measurements. Only the speckles produced by painting in which the paint plays a protective role provide with a better speckle contrast compared with other techniques. However, these speckle patterns enable only a strain measurement of 22% by the DIC method. This article concludes with guidelines for producing a speckle pattern suitable for high‐temperature mechanical tests.


  • Influence of the forming process on the mechanical behavior of a commingled carbon PPS composite part

    by J. Patou, E. De Luycker, R. Bonnaire, T. Cutard, G. Bernhart

    In this research work, the influence of the forming process on commingled thermoplastic composite parts mechanical behavior was investigated. The aim of this work is to evaluate the influence of fabric shearing on the mechanical response of composite laminate. Different sheets with a given shear angle are manufactured. Tensile experimental results are compared with the properties obtained from a simple model based on the laminate plate theory for various off angles. Later, the link with a tetrahedron shape 3D part manufactured by punch deep drawing will be made.


  • Mechanical behavior and modelisation of Ti-6Al-4V titanium sheet under hot stamping conditions

    by Q. Sirvin, V. Velay, R. Bonnaire, L. Penazzi

    The Ti-6Al-4V titanium alloy is widely used for the manufacture of aeronautical and automotive parts (solid parts). In aeronautics, this alloy is employed for its excellent mechanical behavior associated with low density, outstanding corrosion resistance and good mechanical properties up to 600°C. It is especially used for the manufacture of fuselage frames, on the pylon for carrying out the primary structure (machining forged blocks) and the secondary structure in sheet form. In this last case, the sheet metal forming can be done through various methods: at room temperature by drawing operation, at very high temperature (≃900°C) by superplastic forming (SPF) and at intermediate temperature (≥750°C) by hot forming (HF). In order to reduce production costs and environmental troubles, the cycle times reduction associated with a decrease of temperature levels are relevant. This study focuses on the behavior modelling of Ti-6Al-4V alloy at temperatures above room temperature to obtained greater formability and below SPF condition to reduce tools workshop and energy costs. The displacement field measurement obtained by Digital Image Correlation (DIC) is based on innovative surface preparation pattern adapted to high temperature exposures. Different material parameters are identified to define a model able to predict the mechanical behavior of Ti-6Al-4V alloy under hot stamping conditions. The hardening plastic model identified is introduced in FEM to simulate an omega shape forming operation.


  • Open Access

    Characterization of a pressure measuring system for the evaluation of medical devices

    by Rébecca Bonnaire, Marion Verhaeghe, Jérôme Molimard, Paul Calmels, Reynald Convert

    The purpose of this study is to evaluate the possible use of four “FSA” thin and flexible resistive pressure mapping systems, designed by Vista Medical (Winnipeg, Manitoba, Canada), for the measurement of interface pressure exerted by lumbar belts onto the trunk. These sensors were originally designed for the measurement of low pressure applied by medical devices on the skin. Two types of tests were performed: standard metrology tests such as linearity, hysteresis, repeatability, reproducibility and drift, and specific tests for this application such as curvature, surface condition and mapping system superposition. The linear regression coefficient is between 0.86 and 0.98; hysteresis is between 6.29% and 9.41%. Measurements are repeatable. The location, time and operator, measurement surface condition and mapping system superposition have a statistically significant influence on the results. A stable measure is verified over the period defined in the calibration procedure, but unacceptable drift is observed afterward. The measurement stays suitable on a curved surface for an applied pressure above 50 mmHg. To conclude, the sensor has acceptable linearity, hysteresis and repeatability. Calibration must be adapted to avoid drift. Moreover, when comparing different measurements with this sensor, the location, the time, the operator and the measurement surface condition should not change; the mapping system must not be superimposed.