Dmitry Kosterev
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Dmitry Kosterev has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Anthony Faris
Bonneville Power Administration, 17201 Portland, Oregon United States
1 shared publication - Baj Agrawal
IEEE Fellow, Professional Engineer, Arizona Public Service, Phoenix, AZ 85072 USA
1 shared publication - Daniel Douglas
ECSE, Rensselaer Polytechnic Institute, 8024 Troy, New York United States
1 shared publication Don Scoffield
Bonneville Power Administration Pacific Northwest National Laboratory Idaho National Laboratory Lawrence Berkeley National Laboratory
1 shared publication- Eric Heredia
Bonneville Power Administration, 17201 Portland, Oregon United States
1 shared publication - Francis K. Tuffner
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
1 shared publication
Latest Publications
- Open Access
- 1 January 2025
- Published by HICSS Conference Office
Distribution-Level Impacts of Plug-in Electric Vehicle Charging on the Transmission System during Fault Conditions
Transmission planners must identify and plan for the potential impacts of widespread EV charging on the reliability of the grid. This paper examines how the addition of significant EV charging loads would affect regions of the grid that are susceptible to fault induced delayed voltage recovery (or FIDVR). We find that EV chargers that cease drawing current at the onset of faults and that delay drawing current until sometime after a fault has cleared will not exacerbate FIDVR and label this behavior grid friendly. We find that EV chargers that do not cease drawing current at the onset of these faults or that resume drawing current immediately after the fault has cleared will exacerbate FIDVR and label this behavior grid unfriendly. We emphasize that modeling and information on EV charging behaviors is currently limited and recommend engagement by the transmission planning community with the EV manufacturing community to improve this situation.
- 1 January 2025
- Published by HICSS Conference Office
Open AccessDistribution-Level Impacts of Plug-in Electric Vehicle Charging on the Transmission System during Fault Conditions
Transmission planners must identify and plan for the potential impacts of widespread EV charging on the reliability of the grid. This paper examines how the addition of significant EV charging loads would affect regions of the grid that are susceptible to fault induced delayed voltage recovery (or FIDVR). We find that EV chargers that cease drawing current at the onset of faults and that delay drawing current until sometime after a fault has cleared will not exacerbate FIDVR and label this behavior grid friendly. We find that EV chargers that do not cease drawing current at the onset of these faults or that resume drawing current immediately after the fault has cleared will exacerbate FIDVR and label this behavior grid unfriendly. We emphasize that modeling and information on EV charging behaviors is currently limited and recommend engagement by the transmission planning community with the EV manufacturing community to improve this situation.
- 30 May 2018
- Published by Springer Nature
- p. 77-127
Synchrophasor Technology at BPA
- Open Access
- 24 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (4) , 3644-3652
An Optimal Thévenin Equivalent Estimation Method and its Application to the Voltage Stability Analysis of a Wind Hub
A simplified voltage stability analysis method is to use a static Thévenin equivalent to represent the electrical connection to a load center. Assuming fixed values of the Thévenin voltage and reactance, a power-voltage (PV) curve analysis can be performed to find the voltage collapse point and stability margin. This paper proposes a method to compute the static Thévenin equivalent voltage and reactance of a power system using measured data. The method is validated with simulated PMU data and with 24-hour SCADA data at a wind hub on a medium voltage transmission system in the US western system. For the wind hub, the Thévenin equivalent parameters are used to compute the maximum power transfer capability of the wind hub as constrained by voltage stability. Then the method is extended to online application by using short data windows and forgetting factors.
- 24 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (4) , 3644-3652
Open AccessAn Optimal Thévenin Equivalent Estimation Method and its Application to the Voltage Stability Analysis of a Wind Hub
A simplified voltage stability analysis method is to use a static Thévenin equivalent to represent the electrical connection to a load center. Assuming fixed values of the Thévenin voltage and reactance, a power-voltage (PV) curve analysis can be performed to find the voltage collapse point and stability margin. This paper proposes a method to compute the static Thévenin equivalent voltage and reactance of a power system using measured data. The method is validated with simulated PMU data and with 24-hour SCADA data at a wind hub on a medium voltage transmission system in the US western system. For the wind hub, the Thévenin equivalent parameters are used to compute the maximum power transfer capability of the wind hub as constrained by voltage stability. Then the method is extended to online application by using short data windows and forgetting factors.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1-5
Model Validation Studies for a Disturbance Event That Occurred on June 14 2004 in the Western Interconnection
The reliable operation of the interconnected electric system heavily depends upon the accuracy of the dynamic simulation studies. The simulation studies contain models of complex components such as generators, exciter, governors, loads, etc. Many of these models are at best approximate. Hence, the simulation studies must be validated against actual system disturbance from time to time to have confidence in the study results. Such model validation was conducted for a very complex event in WECC interconnected system. It was found necessary to adjust generator saturation and over-excitation models of the units in a large nuclear power plant to achieve a satisfactory correlation. The validated data was then used to run several what if scenarios.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- p. 1-5
Model Validation Studies for a Disturbance Event That Occurred on June 14 2004 in the Western Interconnection
The reliable operation of the interconnected electric system heavily depends upon the accuracy of the dynamic simulation studies. The simulation studies contain models of complex components such as generators, exciter, governors, loads, etc. Many of these models are at best approximate. Hence, the simulation studies must be validated against actual system disturbance from time to time to have confidence in the study results. Such model validation was conducted for a very complex event in WECC interconnected system. It was found necessary to adjust generator saturation and over-excitation models of the units in a large nuclear power plant to achieve a satisfactory correlation. The validated data was then used to run several what if scenarios.