Anthony Faris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Anthony Faris has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Douglas
ECSE, Rensselaer Polytechnic Institute, 8024 Troy, New York United States
1 shared publication - Dmitry Kosterev
Bonneville Power Administration Pacific Northwest National Laboratory Idaho National Laboratory Lawrence Berkeley National Laboratory
1 shared publication - Eric Heredia
Bonneville Power Administration, 17201 Portland, Oregon United States
1 shared publication - Gordon H. Matthews
Bonneville Power Administration, 17201 Portland, Oregon United States
1 shared publication Horacio Silva-Saravia
1 shared publication- Ian Dobson
Iowa State University
1 shared publication
Latest Publications
- Open Access
Real-Time Monitoring of Area Angles with Synchrophasor Measurements
This paper develops a comprehensive framework of Area Angle Monitoring (AAM) to monitor the stress of bulk power transfer across an area of a power transmission system in real-time. Area angle is calculated from synchrophasor measurements to provide alert to system operators if the area angle exceeds pre-defined thresholds. This paper proposes general methods to identify these warning and emergency thresholds, and tests a mitigation strategy to relieve the area stress when the area angle exceeds the threshold. In order to handle the limited coverage of synchrophasor measurements, this paper proposes methods to estimate phase angles for boundary buses without synchrophasor measurements, which extends the application of AAM. AAM is verified for a power transmission area in the Western Electricity Coordinating Council system with both simulated data and synchrophasor measurements recorded from real events. A utility deployment to test the framework for monitoring area angle with live-stream and recorded synchrophasor data is described.
Open AccessReal-Time Monitoring of Area Angles with Synchrophasor Measurements
This paper develops a comprehensive framework of Area Angle Monitoring (AAM) to monitor the stress of bulk power transfer across an area of a power transmission system in real-time. Area angle is calculated from synchrophasor measurements to provide alert to system operators if the area angle exceeds pre-defined thresholds. This paper proposes general methods to identify these warning and emergency thresholds, and tests a mitigation strategy to relieve the area stress when the area angle exceeds the threshold. In order to handle the limited coverage of synchrophasor measurements, this paper proposes methods to estimate phase angles for boundary buses without synchrophasor measurements, which extends the application of AAM. AAM is verified for a power transmission area in the Western Electricity Coordinating Council system with both simulated data and synchrophasor measurements recorded from real events. A utility deployment to test the framework for monitoring area angle with live-stream and recorded synchrophasor data is described.
- Open Access
- 24 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (4) , 3644-3652
An Optimal Thévenin Equivalent Estimation Method and its Application to the Voltage Stability Analysis of a Wind Hub
A simplified voltage stability analysis method is to use a static Thévenin equivalent to represent the electrical connection to a load center. Assuming fixed values of the Thévenin voltage and reactance, a power-voltage (PV) curve analysis can be performed to find the voltage collapse point and stability margin. This paper proposes a method to compute the static Thévenin equivalent voltage and reactance of a power system using measured data. The method is validated with simulated PMU data and with 24-hour SCADA data at a wind hub on a medium voltage transmission system in the US western system. For the wind hub, the Thévenin equivalent parameters are used to compute the maximum power transfer capability of the wind hub as constrained by voltage stability. Then the method is extended to online application by using short data windows and forgetting factors.
- 24 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 33 (4) , 3644-3652
Open AccessAn Optimal Thévenin Equivalent Estimation Method and its Application to the Voltage Stability Analysis of a Wind Hub
A simplified voltage stability analysis method is to use a static Thévenin equivalent to represent the electrical connection to a load center. Assuming fixed values of the Thévenin voltage and reactance, a power-voltage (PV) curve analysis can be performed to find the voltage collapse point and stability margin. This paper proposes a method to compute the static Thévenin equivalent voltage and reactance of a power system using measured data. The method is validated with simulated PMU data and with 24-hour SCADA data at a wind hub on a medium voltage transmission system in the US western system. For the wind hub, the Thévenin equivalent parameters are used to compute the maximum power transfer capability of the wind hub as constrained by voltage stability. Then the method is extended to online application by using short data windows and forgetting factors.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-6
PMU Testing and Installation Considerations at the Bonneville Power Administration
BPA has a real-time phasor measurement system with more than 22 PMUs installed in substations feeding data to a control center. To assure the quality and accuracy of the measurement, BPA has developed an extensive test plan for PMUs. From simple beginnings of basic tests, these procedures have continually evolved with both the variety of PMU equipment and applications for which the data was used. Current test methods under development are aimed for more comprehensive characterization of PMU measurement and test process simplification. Basic test procedures assure steady state accuracy of magnitude, phase, and frequency measurement. Dynamic testing includes step changes to magnitude, phase and frequency as well as signals modulated on the power (60 Hz) waveform. These tests characterize speed of response, reproduction of measured values, and rejection of interference. All these effects have an analogy in the actual power system, so the results can be reasonably applied. Developing methods simplify the generation of test signals and analysis of results. A goal is to test for all measurement aspects that may create a problem and correct these before deployment. In addition, determining characteristics that can be used to adjust all measurements to the same basis will enable the performance of precision analysis regardless of the make or model of PMUs that are making the measurements.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2007 IEEE Power Engineering Society General Meeting
- No. 19325517,p. 1-6
PMU Testing and Installation Considerations at the Bonneville Power Administration
BPA has a real-time phasor measurement system with more than 22 PMUs installed in substations feeding data to a control center. To assure the quality and accuracy of the measurement, BPA has developed an extensive test plan for PMUs. From simple beginnings of basic tests, these procedures have continually evolved with both the variety of PMU equipment and applications for which the data was used. Current test methods under development are aimed for more comprehensive characterization of PMU measurement and test process simplification. Basic test procedures assure steady state accuracy of magnitude, phase, and frequency measurement. Dynamic testing includes step changes to magnitude, phase and frequency as well as signals modulated on the power (60 Hz) waveform. These tests characterize speed of response, reproduction of measured values, and rejection of interference. All these effects have an analogy in the actual power system, so the results can be reasonably applied. Developing methods simplify the generation of test signals and analysis of results. A goal is to test for all measurement aspects that may create a problem and correct these before deployment. In addition, determining characteristics that can be used to adjust all measurements to the same basis will enable the performance of precision analysis regardless of the make or model of PMUs that are making the measurements.