Shuan Dong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Shuan Dong has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Jin Tan
National Laboratory of the Rockies (NLR), Golden, CO (United States)
4 shared publications - Yu Christine Chen
The University of British Columbia
4 shared publications - Andy Hoke
National Laboratory of the Rockies (NLR), Golden, CO (United States)
3 shared publications - Xiaonan Lu
Purdue University, West Lafayette, IN, USA
3 shared publications Yu Christine Chen
Department of Electrical and Computer Engineering, The University of British Columbia, Vancouver, BC, Canada
3 shared publicationsLizhi Ding
Purdue University, West Lafayette, IN, USA
2 shared publications
Latest Publications
- Open Access
- 30 March 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 258
Analytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation
- 30 March 2026
- Published by Elsevier in Electric Power Systems Research
- Vol. 258
Open AccessAnalytical small-signal stability analysis of low-inertia power system frequency response considering secondary frequency regulation
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 72 (9) , 5256-5269
A Twin Circuit Theory-Based Framework for Oscillation Event Analysis in Inverter-Dominated Power Systems With Case Study for Kaua‘i System
This paper proposes a real-world oscillation event analysis framework for power systems that include inverter-based resources together with synchronous generators. Specifically, the proposed framework combines both measurement- and model-based techniques to readily identify potential oscillation sources, replay the oscillation event with numerical simulation, unveil the underlying oscillation mechanism, and suggest mitigation methods for a wide range of oscillation events. To strengthen the theoretical foundation of our analysis framework, this paper proposes a twin circuit theory that provides theoretical support for one key utilized but not well-proven measurement-based oscillation source identification method—Dissipating Energy Flow. Our twin circuit theory also shows that adopting well-tuned grid-forming inverters can be a potential mitigation method for oscillation events. Finally, the effectiveness of our proposed oscillation event analysis framework is demonstrated by addressing a real-world 18–20 Hz oscillation event in Kaua‘i’s power system on November 21, 2021.
- 9 January 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Circuits and Systems I: Regular Papers
- Vol. 72 (9) , 5256-5269
A Twin Circuit Theory-Based Framework for Oscillation Event Analysis in Inverter-Dominated Power Systems With Case Study for Kaua‘i System
This paper proposes a real-world oscillation event analysis framework for power systems that include inverter-based resources together with synchronous generators. Specifically, the proposed framework combines both measurement- and model-based techniques to readily identify potential oscillation sources, replay the oscillation event with numerical simulation, unveil the underlying oscillation mechanism, and suggest mitigation methods for a wide range of oscillation events. To strengthen the theoretical foundation of our analysis framework, this paper proposes a twin circuit theory that provides theoretical support for one key utilized but not well-proven measurement-based oscillation source identification method—Dissipating Energy Flow. Our twin circuit theory also shows that adopting well-tuned grid-forming inverters can be a potential mitigation method for oscillation events. Finally, the effectiveness of our proposed oscillation event analysis framework is demonstrated by addressing a real-world 18–20 Hz oscillation event in Kaua‘i’s power system on November 21, 2021.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (1) , 1131-1147
Holistic Small-Signal Stability Analysis for Large-Scale Inverter-Intensive Power Systems With Coupled and Full-Order Dynamics From Control Systems and Power Networks
The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. In this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.
- 16 October 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industry Applications
- Vol. 61 (1) , 1131-1147
Holistic Small-Signal Stability Analysis for Large-Scale Inverter-Intensive Power Systems With Coupled and Full-Order Dynamics From Control Systems and Power Networks
The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. In this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.
- 24 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (6) , 6053-6065
Inverter Intensive Hybrid Power Plant Modeling With Small-Signal Stability Augmentation Through Flexible Operation Mode Transition
Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.
- 24 July 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Emerging and Selected Topics in Power Electronics
- Vol. 12 (6) , 6053-6065
Inverter Intensive Hybrid Power Plant Modeling With Small-Signal Stability Augmentation Through Flexible Operation Mode Transition
Hybrid power plants (HPPs) prompt the penetration of inverter-based renewable energy sources (RES) in transmission systems; however, given their low-inertia nature, HPPs are dominated by power electronic inverters, so there are inevitable challenges in system stability when increasing numbers of HPPs are integrated into the modern power grids. To boost the penetration level of HPPs without jeopardizing system stability, it is desirable to equip them with operational characteristics (i.e., grid-forming capabilities) that are comparable to those of conventional power plants dominated by synchronous generators (SGs). In this paper, a holistic model of inverter intensive HPP is derived and a bi-level hierarchical control is developed to allow HPPs to flexibly switch among the designed operation modes (i.e., P-Q, P-V, and isochronous modes). Compared to SGs, which have limited controllability, the operation mode of each HPP could vary as requested. Such flexible mode transitions could be integrated into the secondary plant-level control and be leveraged as an additional control degree to further augment system stability. Further, the system small-signal stability margin is quantified with varying HPP operation modes. More importantly, modal analysis is thereby conducted to quantify the impacts of mode transition on the system oscillatory modes. The effectiveness of the proposed HPP bi-level hierarchical control is verified using extensive case studies based on the simplified real-world island power grid, and the results validate that the system small-signal stability margin can be enhanced with the additional degree of control flexibility enabled by HPP operation mode transition. The real-time hardware-in-the-loop (HIL) results are also provided to verify the proposed method.
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2782-2793
Analysis of Feasible Synchronverter Pole-Placement Region to Facilitate Parameter Tuning
This paper derives in analytical closed form the feasible pole-placement region of the synchronverter active-power loop (APL) so as to eliminate all trial-and-error effort in parameter tuning. We consider the well-established setting of a reduced third-order APL model with two controller parameters that can be tuned freely. Thus, only two of the three APL poles can be specified independently in hopes of achieving desired system dynamics. Central to the presented derivation is the realization that the two specified poles must represent the dominant mode of the system. Otherwise the actual system dynamics may be dictated by the third unspecified pole, leading to unexpected or undesired dynamic behaviour. Numerical simulations involving the full-order synchronverter dynamical model and a modified IEEE 39-bus test system validate the analysis and the resulting region within which poles must be placed for actual system dynamics to match desired ones.
- 24 March 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 36 (4) , 2782-2793
Analysis of Feasible Synchronverter Pole-Placement Region to Facilitate Parameter Tuning
This paper derives in analytical closed form the feasible pole-placement region of the synchronverter active-power loop (APL) so as to eliminate all trial-and-error effort in parameter tuning. We consider the well-established setting of a reduced third-order APL model with two controller parameters that can be tuned freely. Thus, only two of the three APL poles can be specified independently in hopes of achieving desired system dynamics. Central to the presented derivation is the realization that the two specified poles must represent the dominant mode of the system. Otherwise the actual system dynamics may be dictated by the third unspecified pole, leading to unexpected or undesired dynamic behaviour. Numerical simulations involving the full-order synchronverter dynamical model and a modified IEEE 39-bus test system validate the analysis and the resulting region within which poles must be placed for actual system dynamics to match desired ones.
- 7 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (1) , 11-23
Analysis of Synchronverter Self-Synchronization Dynamics to Facilitate Parameter Tuning
This paper proposes a self-synchronizing synchronverter controller design that leverages the addition of a virtual resistance (along with a suitable coordinate transformation) to compute feedback signals during self synchronization prior to grid connection. With respect to analysis, we exploit separation-of-time-scales arguments and develop appropriate reduced-order models, which are well-suited for studying phase-angle and voltage-magnitude self-synchronization dynamics independently. Our work provides analytical justification for the effects of pertinent controller parameters and system initial conditions on self-synchronization dynamics observed empirically in time-domain simulations. As such, it offers practical guidance on favourable parameter-value settings to achieve fast self synchronization, and it yields accurate estimates for self-synchronization times with well-tuned parameters. Through numerical simulations and experiments, we illustrate the efficacy of the proposed controller design and verify the validity of subsequent analyses.
- 7 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 35 (1) , 11-23
Analysis of Synchronverter Self-Synchronization Dynamics to Facilitate Parameter Tuning
This paper proposes a self-synchronizing synchronverter controller design that leverages the addition of a virtual resistance (along with a suitable coordinate transformation) to compute feedback signals during self synchronization prior to grid connection. With respect to analysis, we exploit separation-of-time-scales arguments and develop appropriate reduced-order models, which are well-suited for studying phase-angle and voltage-magnitude self-synchronization dynamics independently. Our work provides analytical justification for the effects of pertinent controller parameters and system initial conditions on self-synchronization dynamics observed empirically in time-domain simulations. As such, it offers practical guidance on favourable parameter-value settings to achieve fast self synchronization, and it yields accurate estimates for self-synchronization times with well-tuned parameters. Through numerical simulations and experiments, we illustrate the efficacy of the proposed controller design and verify the validity of subsequent analyses.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1090-1095
Reducing Transient Active- and Reactive-power Coupling in Virtual Synchronous Generators
The virtual synchronous generator is a controller that regulates both active- and reactive-power outputs from a power-electronic converter. In order to vary its output active-power response speed freely, recent research has augmented this controller with the damping correction loop or the transient droop function. By combining these, this paper presents a virtual synchronous generator design that reduces the coupling between its active- and reactive-power outputs while allowing the response speed to be tuned freely. We provide analytical justification for the active- and reactive-power coupling by studying the system transfer function. Closed-form expressions for parameter values are derived to facilitate controller tuning. Finally, we verify the effectiveness of the proposed design via numerical simulations.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1090-1095
Reducing Transient Active- and Reactive-power Coupling in Virtual Synchronous Generators
The virtual synchronous generator is a controller that regulates both active- and reactive-power outputs from a power-electronic converter. In order to vary its output active-power response speed freely, recent research has augmented this controller with the damping correction loop or the transient droop function. By combining these, this paper presents a virtual synchronous generator design that reduces the coupling between its active- and reactive-power outputs while allowing the response speed to be tuned freely. We provide analytical justification for the active- and reactive-power coupling by studying the system transfer function. Closed-form expressions for parameter values are derived to facilitate controller tuning. Finally, we verify the effectiveness of the proposed design via numerical simulations.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Improving Active-power Transfer Capacity of Virtual Synchronous Generator in Weak Grid
The virtual synchronous generator (VSG) is a power-electronic controller that mimics the dynamic behaviour of synchronous generators. It is a promising technology to enable integration of renewable energy conversion systems under weak-grid conditions. By providing virtual inertia, the VSG improves system stability. However, under weak-grid conditions, system stability may also be adversely affected by the VSG exceeding its active-power transfer capacity, leading to a phenomenon known as voltage instability. In this paper, we highlight this problem via simulations conducted for a microgrid test system. Then, we offer analytical justification for the mechanism and root cause of the observed voltage instability. We further propose two countermeasures to improve the active-power transfer capacity. The first is based on existing VSG capabilities so that no new components are needed in the controller, and the second requires additional components but enables full use of the VSG capacity.
- 1 June 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-7
Improving Active-power Transfer Capacity of Virtual Synchronous Generator in Weak Grid
The virtual synchronous generator (VSG) is a power-electronic controller that mimics the dynamic behaviour of synchronous generators. It is a promising technology to enable integration of renewable energy conversion systems under weak-grid conditions. By providing virtual inertia, the VSG improves system stability. However, under weak-grid conditions, system stability may also be adversely affected by the VSG exceeding its active-power transfer capacity, leading to a phenomenon known as voltage instability. In this paper, we highlight this problem via simulations conducted for a microgrid test system. Then, we offer analytical justification for the mechanism and root cause of the observed voltage instability. We further propose two countermeasures to improve the active-power transfer capacity. The first is based on existing VSG capabilities so that no new components are needed in the controller, and the second requires additional components but enables full use of the VSG capacity.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Fast Self-synchronizing Synchronverter Design with Easily Tuneable Parameters
This paper proposes a fast self-synchronizing synchronverter controller design, which synchronizes the synchronverter inner voltage to the grid-side voltage without needing to measure its phase angle, prior to physical connection to the grid. The proposed design centres on the addition of a virtual resistance branch (along with a suitable coordinate transformation), which provides the controller with virtual active- and reactive-power output feedback signals during self synchronization, even though the actual outputs are zero before grid connection. The virtual resistance branch enables fast self synchronization by avoiding inductance dynamics in prevailing methods that use a virtual impedance branch. At the same time, the parameter tuning process is simplified as fewer parameters require tuning. Moreover, the effects of these parameters on synchronization dynamics are well defined. Time-domain simulations are provided to validate that the proposed controller design self synchronizes quickly and that its parameters are easily tuneable.
- 1 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
A Fast Self-synchronizing Synchronverter Design with Easily Tuneable Parameters
This paper proposes a fast self-synchronizing synchronverter controller design, which synchronizes the synchronverter inner voltage to the grid-side voltage without needing to measure its phase angle, prior to physical connection to the grid. The proposed design centres on the addition of a virtual resistance branch (along with a suitable coordinate transformation), which provides the controller with virtual active- and reactive-power output feedback signals during self synchronization, even though the actual outputs are zero before grid connection. The virtual resistance branch enables fast self synchronization by avoiding inductance dynamics in prevailing methods that use a virtual impedance branch. At the same time, the parameter tuning process is simplified as fewer parameters require tuning. Moreover, the effects of these parameters on synchronization dynamics are well defined. Time-domain simulations are provided to validate that the proposed controller design self synchronizes quickly and that its parameters are easily tuneable.
- 9 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (2) , 814-825
A Method to Directly Compute Synchronverter Parameters for Desired Dynamic Response
This paper proposes a method to directly compute controller parameter values in a synchronverter augmented with a so-called damping correction loop, and in so doing, achieve desired transient and steady-state response. The proposed approach is grounded in a reduced third-order system model that captures pertinent dynamic characteristics of the synchronverter active-power loop (APL), particularly those of the dominant mode. This reduced-order model helps to identify and explain a shortcoming in a previous parameter tuning method. Central to the proposed parameter computation method is to express APL parameters of the original system as closed-form functions of the poles of the reduced-order system. Since the reduced-order model retains dominant-mode dynamic behaviours of the original system, APL parameters can be directly computed according to specified APL dominant mode. Time-domain simulations are provided to validate the accuracy of the reduced-order model and the proposed direct-computation parameter tuning method.
- 9 November 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Energy Conversion
- Vol. 33 (2) , 814-825
A Method to Directly Compute Synchronverter Parameters for Desired Dynamic Response
This paper proposes a method to directly compute controller parameter values in a synchronverter augmented with a so-called damping correction loop, and in so doing, achieve desired transient and steady-state response. The proposed approach is grounded in a reduced third-order system model that captures pertinent dynamic characteristics of the synchronverter active-power loop (APL), particularly those of the dominant mode. This reduced-order model helps to identify and explain a shortcoming in a previous parameter tuning method. Central to the proposed parameter computation method is to express APL parameters of the original system as closed-form functions of the poles of the reduced-order system. Since the reduced-order model retains dominant-mode dynamic behaviours of the original system, APL parameters can be directly computed according to specified APL dominant mode. Time-domain simulations are provided to validate the accuracy of the reduced-order model and the proposed direct-computation parameter tuning method.