MDMartin Dirisamer

Martin Dirisamer

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Martin Dirisamer has a total of 24 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Impact of Iris Color and Laterality on Lenticule Extraction Time in Keratorefractive Lenticule Extraction (KLEx)

    by Paul Emesz, Lukas Feldhaus, Barbara Sophie Brunner, Lukas Neuhann, Jascha Wendelstein, Martin Dirisamer, Siegfried Georg Priglinger, Stefan Kassumeh, Nikolaus Luft

    Purpose: This study aims to evaluate the effects of iris color and laterality on keratorefractive lenticule extraction (KLEx) surgery time. Setting: A retrospective analysis was conducted on 656 eyes of 328 patients undergoing small incision lenticule extraction (SMILE). Mean patient age was 32 ± 7 years. Methods: Preoperative parameters, including manifest refraction spherical equivalent (MRSE), refractive cylinder, and corrected distance visual acuity (CDVA), were measured. Iris color was classified as “light” (n = 390) or “dark” (n = 266) by a senior ophthalmologist as the grader. Surgical time was determined from video recordings, defined as the time between opening of the KLEx incision and extraction of the lenticule. The surgery was performed by a single highly experienced, right-handed refractive surgeon. Results: Eyes with light irides showed significantly shorter lenticule extraction times than those with dark irides (75 ± 22 s vs. 90 ± 31 s, p < 0.0001). No statistically significant differences were found between eyes with light and dark irides in terms of postoperative MRSE, refractive cylinder, uncorrected distance visual acuity (UDVA), CDVA, safety and efficacy index, respectively (p > 0.05 for all). Surgical time was significantly shorter in right eyes compared to left eyes (74 ± 25 s vs. 89 ± 27 s, p < 0.0001). When analyzing laterality and iris color, surgery was shortest in right eyes with light irides (68 ± 19 s) and longest in left eyes with dark irides (97 ± 31 s; p < 0.0001). Conclusions: SMILE surgery took significantly less time in patients with light irides and in the right eyes compared to dark irides and the left eyes. These findings suggest that patients’ iris color and laterality in relation to surgeon handedness may influence the ease of surgical lenticule extraction to a comparable extent.

  • Open Access

    Feasibility and Postoperative Outcome After Duet Procedure for Reversible Multifocality in Eyes with Co-Pathologies

    by Barbara S. Brunner, Martin Dirisamer, Nikolaus Luft, Stefan Kassumeh, Siegfried G. Priglinger

    Objectives: To evaluate the safety and efficacy of the simultaneous implantation of a monofocal capsular bag-fixated and a trifocal supplementary sulcus-fixated intraocular lens (duet procedure) in eyes with co-existing pathologies undergoing cataract or refractive lens surgery. Methods: In total, 80 eyes of 40 consecutive patients, who underwent refractive lens exchange or cataract surgery and received the duet procedure due to minor co-pathologies, were included in this retrospective case series. Preoperative assessment comprised slit-lamp biomicroscopy, optical biometry, posterior-segment optical coherence tomography, corneal endothelial specular microscopy, corneal tomography, manifest refraction and distance and near visual acuity testing. Three months postoperatively, uncorrected distance (UDVA) and uncorrected near visual acuity (UNVA) were recorded. Results: The preoperative manifest refractive spherical equivalent (MRSE) was −0.31 ± 4.29 diopters (D), with a mean refractive astigmatism of −0.80 ± 0.60 D. At three months postoperatively, monocular UDVA and binocular UNVA significantly improved from 0.52 ± 0.42 logMAR and 0.32 ± 0.27 logMAR to 0.05 ± 0.09 logMAR and −0.03 ± 0.10 logMAR, respectively (both p < 0.0001). Conclusions: Reversible multifocality provided by the duet procedure appears to be a feasible option in eyes with mild co-existing pathologies, as it yields satisfactory visual and refractive outcomes with high safety.


  • Open Access

    Corneal Epithelial Wavefront Error as a Novel Diagnostic Marker for Epithelial Basement Membrane Dystrophy

    by Vitus Grauvogl, Wolfgang J. Mayer, Jakob Siedlecki, Niklas Mohr, Martin Dirisamer, Siegfried G. Priglinger, Stefan Kassumeh, Nikolaus Luft

    Synopsis: Corneal epithelial wavefront error and epithelial thickness variance qualify as highly sensitive and specific biomarkers for epithelial basement membrane dystrophy (EBMD). The biomarkers show a normalization after treatment of EBMD with phototherapeutic keratectomy. Purpose: To gauge the diagnostic value of epithelial basement membrane dystrophy (EBMD), a novel spectral-domain optical coherence tomography (SD-OCT)-based imaging modality for simultaneous morphological (thickness profile) and refractive (optical wavefront) assessment of the corneal epithelial layer in one of the most common but often underdiagnosed corneal dystrophies. Methods: In this prospective observational study, a total of 32 eyes of 32 patients diagnosed with EBMD and 32 eyes of 32 healthy control subjects were examined with high-resolution anterior segment SD-OCT (MS-39; CSO, Florence, Italy). Various epithelial thickness and epithelial wavefront-derived terms were compared between groups and receiver operating characteristic (ROC) curves were computed to analyze the diagnostic capacity of the respective parameters. A total of 17 of 32 EBMD patients underwent treatment with phototherapeutic keratectomy (PTK) and were followed up for 3 months. Results: Epithelial thickness variance (60.4 ± 56.7 µm versus 7.6 ± 6.1 µm) and interquartile range (11.0 ± 6.9 versus 3.3 ± 1.9 µm) were markedly elevated in EBMD patients as compared with healthy controls (both with p < 0.001). Epithelial wavefront analysis showed a highly statistically significant excess in all examined aberration terms in EBMD patients (all with p < 0.001). Significantly greater areas under the curve (AUCs) were yielded by the epithelial wavefront-derived parameters (e.g., total epithelial wavefront error: AUC = 0.966; 95% confidence interval (CI) 0.932–1) than by the epithelial thickness-derived parameters (e.g., variance: AUC = 0.919; 95% CI 0.848–0.990). Conclusions: Corneal epithelial wavefront aberrometry proved valuable as an objective biomarker for EBMD, with high sensitivity and specificity. PTK resulted in a reduction of morphological and refractive epithelial irregularities in EBMD.


  • Open Access

    Corneal Epithelial Wavefront Error as a Novel Objective Biomarker Diagnostic Marker for Epithelial Basement Membrane Dystrophy

    by Vitus Grauvogl, Wolfgang J. Mayer, Jakob Siedlecki, Niklas Mohr, Martin Dirisamer, Siegfried Georg Priglinger, Stefan Kassumeh, Nikolaus Luft

    Synopsis Corneal epithelial wavefront error and epithelial thickness variance qualify as highly sensitive and specific biomarkers for epithelial basement membrane dystrophy (EBMD). The biomarkers show a normalization after treatment of EBMD with phototherapeutic keratectomy. Purpose: To gauge the diagnostic value of a novel spectral-domain optical coherence tomography (SD-OCT) based imaging modality for simultaneous morphological (thickness profile) and refractive (optical wavefront) assessment of the corneal epithelial layer in one of the most common but often underdiagnosed corneal dystrophies: epithelial basement membrane dystrophy (EBMD). Methods: In this prospective observational study, a total of 32 eyes of 32 patients diagnosed with EBMD and 32 eyes of 32 healthy control subjects were examined with high-resolution anterior segment SD-OCT (MS-39; CSO, Florence, Italy). Various epithelial thickness and epithelial wavefront derived terms were compared between groups and receiver operating characteristic (ROC) curves were computed to analyze the diagnostic capacity of the respective parameters. A total of 17 of 32 EBMD patients underwent treatment with phototherapeutic keratectomy (PTK) and were followed up for 3 months. Results: Epithelial thickness variance (60.4 ± 56.7 µm versus 7.6 ± 6.1 µm) and interquartile range (11.0±6.9 versus 3.3±1.9 µm) were markedly elevated in EBMD patients as compared with healthy controls (both with p < 0.001). Epithelial wavefront analysis showed a highly statistically significant excess in all examined aberration terms in EBMD patients (all with p < 0.001). Significantly greater areas under the curve (AUC) were yielded by the epithelial wavefront derived parameters (e.g. total epithelial wavefront error: AUC = 0.966; 95% confidence interval (CI) 0.932 – 1) than by the epithelial thickness-derived parameters (e.g., variance: AUC = 0.919; 95% CI 0.848 – 0.990). Conclusion: Corneal epithelial wavefront aberrometry proved valuable as an objective biomarker for EBMD with high sensitivity and specificity. PTK resulted in a reduction of morphological and refractive epithelial irregularities in EBMD.


  • Open Access

    Epithelial Remodeling and Epithelial Wavefront Aberrometry after Spherical vs. Cylindrical Myopic Small Incision Lenticule Extraction (SMILE)

    by Barbara S. Brunner, Lukas Feldhaus, Wolfgang J. Mayer, Jakob Siedlecki, Martin Dirisamer, Siegfried G. Priglinger, Stefan Kassumeh, Nikolaus Luft

    Background/Objectives: To compare the epithelial thickness changes and the changes in epithelial wavefront aberrometry following spherical versus astigmatic myopic small incision lenticule extraction (SMILE). Methods: Eighty-six eyes of 86 patients who underwent SMILE were included in this retrospective study. A total of 43 eyes underwent myopic spherical correction (spherical group) and 43 eyes underwent myopic cylindrical correction (cylindrical group). The groups were matched according to the spherical equivalent of surgically corrected refraction. Subjective manifest refraction as well as high-resolution anterior segment optical coherence tomography (MS-39; CSO; Florence, Italy) were obtained preoperatively as well as 3 months postoperatively. The latter was utilized for computing epithelial wavefront aberrometry in addition to epithelial thickness mapping. Results: Epithelial thickness increased significantly in both groups after SMILE (p < 0.01). In the cylindrical group, epithelial thickening was more pronounced on the flat meridian compared to the steep meridian (p = 0.04). In both groups, epithelial wavefront aberrometry showed a significant postoperative increase in the epithelium’s spherical refractive power, causing a myopization of −0.24 ± 0.42 diopters (D) in the spherical group (p < 0.01) and −0.41 ± 0.52 D in the cylindrical group (p < 0.0001). While no significant changes in epithelial cylindrical refractive power were observed in the spherical group, a significant increase was noted in the cylindrical group from −0.21 ± 0.24 D to −0.37 ± 0.31 D (p = 0.01). In both groups, epithelial higher-order aberrations increased significantly (p < 0.001). Conclusions: Postoperative epithelial remodeling after SMILE alters lower-order (sphere and cylinder) and higher-order aberrations of the corneal epithelial wavefront and might contribute to refractive undercorrection, especially in astigmatic corrections. Epithelial wavefront aberrometry can be used to quantify the refractive effect of epithelial remodeling processes after keratorefractive surgery.


  • Open Access

    IOL Power Calculations and Cataract Surgery in Eyes with Previous Small Incision Lenticule Extraction

    by Roman Lischke, Walter Sekundo, Rainer Wiltfang, Martin Bechmann, Thomas C. Kreutzer, Siegfried G. Priglinger, Martin Dirisamer, Nikolaus Luft

    Small incision lenticule extraction (SMILE), with over 5 million procedures globally performed, will challenge ophthalmologists in the foreseeable future with accurate intraocular lens power calculations in an ageing population. After more than one decade since the introduction of SMILE, only one case report of cataract surgery with IOL implantation after SMILE is present in the peer-reviewed literature. Hence, the scope of the present multicenter study was to compare the IOL power calculation accuracy in post-SMILE eyes between ray tracing and a range of empirically optimized formulae available in the ASCRS post-keratorefractive surgery IOL power online calculator. In our study of 11 post-SMILE eyes undergoing cataract surgery, ray tracing showed the smallest mean absolute error (0.40 D) and yielded the largest percentage of eyes within ±0.50/±1.00 D (82/91%). The next best conventional formula was the Potvin–Hill formula with a mean absolute error of 0.66 D and an ±0.50/±1.00 D accuracy of 45 and 73%, respectively. Analyzing this first cohort of post-SMILE eyes undergoing cataract surgery and IOL implantation, ray tracing showed superior predictability in IOL power calculation over empirically optimized IOL power calculation formulae that were originally intended for use after Excimer-based keratorefractive procedures.


  • Stromal remodeling and lenticule thickness accuracy in small-incision lenticule extraction: One-year results

    by Nikolaus Luft, Siegfried G. Priglinger, Michael H. Ring, Wolfgang J. Mayer, Anna S. Mursch-Edlmayr, Thomas C. Kreutzer, Matthias Bolz, Martin Dirisamer

    To prospectively characterize the stromal thickness changes during the first year after myopic small-incision lenticule extraction using spectral-domain optical coherence tomography (SD-OCT). Department of Ophthalmology, Kepler University Hospital, Linz, Austria. Prospective case series. This study evaluated eyes that had small-incision lenticule extraction to treat myopia or myopic astigmatism. A high-resolution SD-OCT system (RS 3000 Advance) in conjunction with a custom image-segmentation algorithm was applied to directly measure stromal thickness within the central 5.0 mm corneal zone. Measurements were obtained preoperatively and postoperatively at 1 day, 1 week, 6 weeks, 3 months, 6 months, and 1 year. The study enrolled 42 eyes of 21 patients. The mean surgical refractive correction was -4.94 diopters ± 1.75 (SD). Postoperatively, the stromal thickness showed a significant decrease during the first 6 weeks, which amounted to a mean of 10.4 ± 6.3 μm at the apex (P < .001). Subsequently, the central stroma thickened by a mean of 8.8 ± 5.9 μm up until the 1-year follow-up (P < .001). One year postoperatively, the mean observed central stromal thickness reduction was 18.7 ± 5.7 μm smaller than the planned lenticule thickness. This difference was smallest 6 weeks postoperatively (mean 9.8 ± 7.8 μm). Significant anatomic changes in the corneal stroma were detected during the first year after small-incision lenticule extraction. The achieved lenticule thickness was systematically lower than planned, and the mismatch was more pronounced with higher lenticule thickness. Refractive outcomes did not appear to be influenced by lenticule thickness accuracy.