IOL Power Calculations and Cataract Surgery in Eyes with Previous Small Incision Lenticule Extraction
Open Access
- 29 July 2022
- journal article
- research article
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (15) , 4418
Abstract
Small incision lenticule extraction (SMILE), with over 5 million procedures globally performed, will challenge ophthalmologists in the foreseeable future with accurate intraocular lens power calculations in an ageing population. After more than one decade since the introduction of SMILE, only one case report of cataract surgery with IOL implantation after SMILE is present in the peer-reviewed literature. Hence, the scope of the present multicenter study was to compare the IOL power calculation accuracy in post-SMILE eyes between ray tracing and a range of empirically optimized formulae available in the ASCRS post-keratorefractive surgery IOL power online calculator. In our study of 11 post-SMILE eyes undergoing cataract surgery, ray tracing showed the smallest mean absolute error (0.40 D) and yielded the largest percentage of eyes within ±0.50/±1.00 D (82/91%). The next best conventional formula was the Potvin–Hill formula with a mean absolute error of 0.66 D and an ±0.50/±1.00 D accuracy of 45 and 73%, respectively. Analyzing this first cohort of post-SMILE eyes undergoing cataract surgery and IOL implantation, ray tracing showed superior predictability in IOL power calculation over empirically optimized IOL power calculation formulae that were originally intended for use after Excimer-based keratorefractive procedures.Keywords
All Related Versions
This publication has 32 references indexed in Scilit:
- Accuracy of Intraocular Lens Calculation With Ray TracingJournal of Refractive Surgery, 2012
- Small incision corneal refractive surgery using the small incision lenticule extraction (SMILE) procedure for the correction of myopia and myopic astigmatism: results of a 6 month prospective studyBritish Journal of Ophthalmology, 2010
- Intraocular lens power calculation after previous laser refractive surgeryJournal of Cataract & Refractive Surgery, 2009
- Comparison of ray-tracing method and thin-lens formula in intraocular lens power calculationsJournal of Cataract & Refractive Surgery, 2009
- Intraocular lens calculation after refractive surgery for myopia: Haigis-L formulaJournal of Cataract & Refractive Surgery, 2008
- No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusisJournal of Cataract & Refractive Surgery, 2007
- Estimation of true corneal power after keratorefractive surgery in eyes requiring cataract surgery: BESSt formulaJournal of Cataract & Refractive Surgery, 2006
- Intraocular lens power calculation after laser in situ keratomileusis: Aphakic refraction techniqueJournal of Cataract & Refractive Surgery, 2006
- Intraocular lens power calculation using ray tracing following excimer laser surgeryEye, 2006
- Comparison of intraocular lens power calculation methods in eyes that have undergone LASIKOphthalmology, 2004