Daniel N. Lacroix
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel N. Lacroix has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Ghasan Doudak
Faculty of Civil Engineering, University of Ottawa, Ottawa, Canada
3 shared publications - Christian Viau
Carleton University
1 shared publication - Mathieu Poulin
M.A.Sc. Student, Dept. of Civil Engineering, Univ. of Ottawa, Ottawa, ON, Canada K1N 6N5
1 shared publication
Latest Publications
- 1 September 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (9)
Determining the Dynamic Increase Factor for Glued-Laminated Timber Beams
This paper presents the results from an experimental program that investigated the flexural behavior of glulam beams subjected to dynamic loading. A total of thirty-eight beams consisting of three different cross-sections were tested destructively under both static and dynamic loads. The analysis resulted in a dynamic increase factor (DIF) of 1.14 for strain-rates ranging between 0.14 and , however, the increase was only observed when the outer tension laminate did not include continuous finger-joints (single laminate width) or closely aligned finger-joints (multiple laminates width) in the high moment region causing a straight fracture across the width. No increase due to high strain-rate effects was found when a continuous failure across the width due to finger-joints (FJs) were present in the outer tension laminate, and thus if continuous laminates, uninterrupted by FJs cannot be guaranteed, a dynamic increase factor of unity is suggested for design. Since the beams exhibited little to no ductility, it is recommended that a linear-elastic resistance curve be used to generate the dynamic resistance curve. An equivalent single-degree-of-freedom (SDOF) model accounting for high strain-rate effects using the derived DIF, where appropriate, captured the displacement at failure, time to failure, and displaced shape with reasonable accuracy.- 1 September 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (9)
Determining the Dynamic Increase Factor for Glued-Laminated Timber Beams
This paper presents the results from an experimental program that investigated the flexural behavior of glulam beams subjected to dynamic loading. A total of thirty-eight beams consisting of three different cross-sections were tested destructively under both static and dynamic loads. The analysis resulted in a dynamic increase factor (DIF) of 1.14 for strain-rates ranging between 0.14 and , however, the increase was only observed when the outer tension laminate did not include continuous finger-joints (single laminate width) or closely aligned finger-joints (multiple laminates width) in the high moment region causing a straight fracture across the width. No increase due to high strain-rate effects was found when a continuous failure across the width due to finger-joints (FJs) were present in the outer tension laminate, and thus if continuous laminates, uninterrupted by FJs cannot be guaranteed, a dynamic increase factor of unity is suggested for design. Since the beams exhibited little to no ductility, it is recommended that a linear-elastic resistance curve be used to generate the dynamic resistance curve. An equivalent single-degree-of-freedom (SDOF) model accounting for high strain-rate effects using the derived DIF, where appropriate, captured the displacement at failure, time to failure, and displaced shape with reasonable accuracy.- 1 May 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (5)
Effects of High Strain Rates on the Response of Glulam Beams and Columns
A material predictive model that accounts for strain-rate effects and captures the effect of variable axial load on the dynamic response of glulam structural members subjected to combined lateral-blast and axial loading is developed and validated using experimental data for full-scale blast tests on beam and column specimens. Composite resistance curves, which capture the loss in axial load as the column displaces laterally, were shown to corroborate well with the measured axial-load time history and resistance curves. It was also found that the columns’ resistance can be obtained using an equivalent lateral-load approach when experimentally measured displacement, pressure, reaction, and axial-load time histories are considered. The model was also capable of predicting the maximum displacement and time to maximum displacement with reasonable accuracy.
- 1 May 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (5)
Effects of High Strain Rates on the Response of Glulam Beams and Columns
A material predictive model that accounts for strain-rate effects and captures the effect of variable axial load on the dynamic response of glulam structural members subjected to combined lateral-blast and axial loading is developed and validated using experimental data for full-scale blast tests on beam and column specimens. Composite resistance curves, which capture the loss in axial load as the column displaces laterally, were shown to corroborate well with the measured axial-load time history and resistance curves. It was also found that the columns’ resistance can be obtained using an equivalent lateral-load approach when experimentally measured displacement, pressure, reaction, and axial-load time histories are considered. The model was also capable of predicting the maximum displacement and time to maximum displacement with reasonable accuracy.
- 1 February 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (2)
Experimental and Analytical Investigation of Cross-Laminated Timber Panels Subjected to Out-of-Plane Blast Loads
Presented in this paper are the results of an experimental program investigating the out-of-plane behavior of CLT panels under static and blast loading. A total of 18 CLT panels, with panel thicknesses of 105 and 175 mm corresponding to a 3-ply and 5-ply panel, respectively, were investigated with the aim to determine the dynamic increase factor (DIF). An average dynamic increase factor of 1.28 on the resistance and no apparent increase in stiffness from static to dynamic loading were observed. Two resistance material predictive models that account for high strain-rate effects and the experimentally observed post-peak residual behavior were developed. A single-degree-of-freedom model was validated using full-scale simulated blast load tests, and the predictions were found to match well with the experimental displacement-time histories.
- 1 February 2018
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 144 (2)
Experimental and Analytical Investigation of Cross-Laminated Timber Panels Subjected to Out-of-Plane Blast Loads
Presented in this paper are the results of an experimental program investigating the out-of-plane behavior of CLT panels under static and blast loading. A total of 18 CLT panels, with panel thicknesses of 105 and 175 mm corresponding to a 3-ply and 5-ply panel, respectively, were investigated with the aim to determine the dynamic increase factor (DIF). An average dynamic increase factor of 1.28 on the resistance and no apparent increase in stiffness from static to dynamic loading were observed. Two resistance material predictive models that account for high strain-rate effects and the experimentally observed post-peak residual behavior were developed. A single-degree-of-freedom model was validated using full-scale simulated blast load tests, and the predictions were found to match well with the experimental displacement-time histories.