AAAloys Martial Ekoe A. Akata

Aloys Martial Ekoe A. Akata

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Aloys Martial Ekoe A. Akata has a total of 14 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Review on Solar Cooling Technologies and A Bibliometric Analysis of their Research Trends in Africa

    by Elisée Ndam Menandi, Aloys Martial Ekoe A. Akata, Armelle Abourou Telanga, Abbo Sanda Oumarou

    Solar energy is free and accessible to everybody on the planet, and its production and exploitation do not pollute the environment. It offers many other advantages such as reducing main grid demand and enabling people in remote areas to have access to energy. Providing cooling by utilizing solar energy for refrigeration purposes or thermal comfort has become one of the main solutions to the energy crisis and environmental issues. This study is divided into two parts. The first part provides a detailed review of solar refrigeration techniques (photovoltaic solar-powered systems and thermally driven cooling systems) and a bibliometric analysis aiming to study the research trends in Africa during the past ten years in solar refrigeration technologies is considered in the second part. A database of 1366 documents using the free access database Dimensions.ai was consulted and analysed using the R packages Bibliometrix and Biblioshiny. It can be observed that northern African countries are the most productive in the solar cooling domain, and far behind them are some other countries like South Africa or Nigeria, creating a huge gap in the research field between those northern African countries and the rest of Africa. Nevertheless, only a limited number of articles were accessible because our institution does not have access to paid databases like Web of Science or Scopus that offer broader results as compared to free databases, highlighting, therefore, another major difficulty that researchers face in most sub-Saharan countries.

  • Open Access

    Predicting the Efficiency of Solar Photovoltaic Energy Injection in a Localized Subtropical Grid by Modelling Actual Generation Trend Curves: Case Study of Douala

    by Georgette Fumtchum, Aloys Martial, Ekoe Akata, Ruben Mouangue, Brayima Dakyo

    Electrified cities in Cameroon suffer untimely power outages for several reasons, among which a low production of electrical energy; a palliative solution of the consequences would be, as projected, to identify and supply priority loads through solar photovoltaic electrification. Producing solar photovoltaic (PV) energy and injecting it into the domestic conventional electricity network (CEN), to supply priority loads, has to face high investment costs and in the economic and technical context, the feasibility and also the long-term efficiency must be analyzed. Based on the regulation of a set of production units, the collection of actual production and consumption data from several sites in the city of Douala was used. An analysis of the data from the data acquisition systems of the reference installations allowed the development of production models of the PV systems injected into the targeted conventional electricity network (CEN). Consumption modelling of PV system output over a long lifetime will be developed. Based on the collected real data, simulations of long-term load supply scenarios will be performed in the MATLAB software package environment. The influence of operational parameters on the efficiency of solar energy injections will be evaluated in order to improve productivity until the end of the system's life. We will show through the simulation of previously and judiciously selected conditions, the modalities of a good prediction of the efficiency of the solar energy injection in the urban CEN.

  • Open Access

    Tilt Angle and Orientation Assessment of Photovoltaic Thermal (PVT) System for Sub-Saharan Tropical Regions: Case Study Douala, Cameroon

    by Aloys Martial Ekoe A Akata, Donatien Njomo, Basant Agrawal, Auguste Mackpayen, Abdel-Hamid Mahamat Ali

    Photovoltaic systems when integrated into a building structure can satisfy the world’s energy requirements at a competitive cost by providing onsite electrical and thermal energies for domestic appliances. The energy yield of the photovoltaic system is affected by the intensity of the solar radiation, wind speed, tilt angle, orientation, geographical location, etc. This paper presents an optimisation model of the tilt angle and orientation of a photovoltaic thermal system. A methodology has been developed to optimize the tilted angle of the roof for higher exergy output taking into account the intensity of solar radiation, wind speed, geographical location, cost of cleaning dust, etc. For a system installed in the city of Douala, Cameroon, it is recommended that the PV should be inclined at an angle between 10° and 20° south-facing for economical output. The cost per unit of electricity between the tilt inclination angles from 0° to 20° with south orientation is USD 0.04 per kWh. The cost of electricity loss due to a 20° tilt inclination angle can be compensated with the labour cost and work required for cleaning the photovoltaic thermal (PVT) system of the horizontal roof. The system installed over an effective area of 8 m2 is capable of producing annual net exergy of 2195.81 kWh/year at an efficiency of 11.8%.


  • Open Access

    The effect of building integrated photovoltaic system (Bipvs) on indoor air temperatures and humidity (Iath) in the tropical region of Cameroon

    by Martial Aloys Ekoe a Akata, Donatien Njomo, Blaise Mempouo

    The building sector accounts for around 40-50% of the energy consumed in developing countries and contribute over 30% of CO2 emissions. In Cameroon, the electricity access is less than 5% in rural areas against 50% in urban areas. All sectors combined the Cameroonian final energy consumption amounts to approximately 5235 kilo-tonnes of oil equivalent (Ktoe) and 73% of this energy are assigned for residential use. This energy can be considerably reduced with the development of low energy buildings using Building Integrated Photovoltaic (BIPV), since it has been proven an effective solution to achieve significant energy savings and conservation. However, photovoltaic (PV) panels produce a substantial amount of heat, while generating power. Consequently, BIPV’s concept, where the photovoltaic (PV) panel is integrated on the building envelops has significant influence on the amount of heat transfer through the building fabrics, and could affect the indoor air temperatures and the comfort of the occupants, since, it changes the thermal resistance of the building envelops. In this paper, the effect of the BIPV on the indoor air temperatures and humidity (IATH) of a multiple storey buildings under the tropical climatic conditions of Yaoundé, Cameroon has been modelled and analysed. Two cases of BIPV made of 290 m2 area of PV have been considered, i) roof integrated and ii) façade integrated. In addition, building orientation, roof pitch and the building materials are also been explored and optimised to provide the best combination. It has been observed that for both cases, BIPV increases the building’s indoor air temperature by about 4 °C, when compare to a building of the same size without PV integrated.

  • Open Access

    Thermal Energy Optimization of Building Integrated Semi-Transparent Photovoltaic Thermal Systems

    by Ekoe A Akata Aloys Martial, Donatien Njomo, Basant Agrawal

    Building integrated photovoltaic (BIPV) : The concept where the photovoltaic element assumes the function of power generation and the role of the covering component element has the potential to become one of the principal sources of renewable energy for domestic purpose. In this paper, a Building integrated semitransparent photovoltaic thermal system (BISPVT) system having fins at the back sheet of the photovoltaic module has been simulated. It has been observed that this system produces higher thermal and electrical efficiencies. The increase of wind velocity by fan system and heat exchange surface accelerates the convective heat transfer between the finned surface and the fluid flowing in the duct. The system area of 36.45 m2 is capable of annually producing an amount of thermal energy of 76.66 kWh at an overall thermal efficiency of 56.07 %.