Barbu Cristian Braun
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Barbu Cristian Braun has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Ionel Șerban
Transilvania University of Brasov
11 shared publications - Corneliu Nicolae Drugă
Transilvania University of Brasov
10 shared publications - Mihaela Ioana Baritz
Transilvania University of Brasov
5 shared publications - Alexandru-Constantin Tulică
Transilvania University
4 shared publications - Angela Repanovici
Faculty of Product Design and Environment, Transilvania University of Brasov, 500036 Brasov, Romania
4 shared publications - Mitu Leonard
Transilvania University of Brasov
4 shared publications
Latest Publications
- Open Access
- 9 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 148 (1) , 31
Research on Smart Alert Systems Improving for Alone or Special Needs Persons
This paper describes the design, fabrication, and successful evaluation of a wristband developed for alerting users in critical situations. The target group is single people, especially the elderly, but also people with various disabilities. A low-cost wristband, which, when these people fall, immediately triggers a Wi-Fi-connected alert system on the gadgets of the staff or the person belonging to them. The system is implemented as a wearable forearm sleeve that integrates multiple sensors and electronic components, capable of sending instant alerts to family members or caregivers via the Blynk application.
- 9 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 148 (1) , 31
Open AccessResearch on Smart Alert Systems Improving for Alone or Special Needs Persons
This paper describes the design, fabrication, and successful evaluation of a wristband developed for alerting users in critical situations. The target group is single people, especially the elderly, but also people with various disabilities. A low-cost wristband, which, when these people fall, immediately triggers a Wi-Fi-connected alert system on the gadgets of the staff or the person belonging to them. The system is implemented as a wearable forearm sleeve that integrates multiple sensors and electronic components, capable of sending instant alerts to family members or caregivers via the Blynk application.
- Open Access
- 9 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 148 (1) , 22
Low-Cost Solution for Increasing Efficiency in Chromatic Perception for Visual Screening
Th paper describes a low-cost solution forsignificantly increasing the efficiency of color perception testing for visual screening. The target areas are school and preschool children, people taking medical exams, testing in occupational medicine, and military recruitment. The research involved two stages: developing a virtual application for rapid and objective assisted testing of chromatic vision, and effectively testing about 30 subjects, of different social and age categories, for visual screening. We proved not the low cost, but also the high effectiveness of the method. This creates potential for a better way to prevent visual impairments, especially in children.
- 9 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 148 (1) , 22
Open AccessLow-Cost Solution for Increasing Efficiency in Chromatic Perception for Visual Screening
Th paper describes a low-cost solution forsignificantly increasing the efficiency of color perception testing for visual screening. The target areas are school and preschool children, people taking medical exams, testing in occupational medicine, and military recruitment. The research involved two stages: developing a virtual application for rapid and objective assisted testing of chromatic vision, and effectively testing about 30 subjects, of different social and age categories, for visual screening. We proved not the low cost, but also the high effectiveness of the method. This creates potential for a better way to prevent visual impairments, especially in children.
- Open Access
- 8 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 148 (1) , 18
Modeling and Evaluation of the Influence of Chromatic and Emotional Parameters on Eye Movements in Biomedical Applications
Eye-tracking technologies enable precise measurement of eye movements and are widely used in visual behavior analysis and biomedical engineering applications. Oculomotor parameters, such as fixation duration, saccades, and pupil dilation, are influenced by both visual stimulus characteristics and emotional state; however, the relationships between these factors are difficult to model in a coherent manner. In this context, this paper proposes a model for describing the influence of wavelength and emotional parameters on eye movements. The model expresses oculomotor parameters as functions of the input variables, using simplified relationships that allow both interpretability and practical implementation. To analyze the model, a MATLAB-based application was developed, enabling the simulation of oculomotor behavior under different scenarios. The obtained results highlight variations in the analyzed parameters depending on the input conditions and support the applicability of the model in biomedical monitoring and visual behavior assessment.
- 8 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 148 (1) , 18
Open AccessModeling and Evaluation of the Influence of Chromatic and Emotional Parameters on Eye Movements in Biomedical Applications
Eye-tracking technologies enable precise measurement of eye movements and are widely used in visual behavior analysis and biomedical engineering applications. Oculomotor parameters, such as fixation duration, saccades, and pupil dilation, are influenced by both visual stimulus characteristics and emotional state; however, the relationships between these factors are difficult to model in a coherent manner. In this context, this paper proposes a model for describing the influence of wavelength and emotional parameters on eye movements. The model expresses oculomotor parameters as functions of the input variables, using simplified relationships that allow both interpretability and practical implementation. To analyze the model, a MATLAB-based application was developed, enabling the simulation of oculomotor behavior under different scenarios. The obtained results highlight variations in the analyzed parameters depending on the input conditions and support the applicability of the model in biomedical monitoring and visual behavior assessment.
- Open Access
- 8 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 148 (1) , 17
Biomechanical Assessment of Walking in Simulated Low-Vision Conditions Using a Visual Aid Device
Low vision is a major factor limiting mobility and increasing the risk of falls globally, with a significant impact on quality of life. The article presents the analysis of the effects of simulated visual dysfunctions—cataract and glaucoma—on the biomechanical parameters of gait and evaluates the effectiveness of a portable device based on ultrasonic sensors, called the Tridirectional Device. A sample of 25 clinically healthy subjects was evaluated in five experimental conditions, using a plantar pressure distribution analysis system (RSScan), the Tinetti scale and the center of pressure trajectory analysis. The results highlight changes in gait parameters under the conditions of use of the device, suggesting its potential as an accessible and non-invasive solution for supporting people with visual impairments.
- 8 July 2026
- Published by MDPI AG in Engineering Proceedings
- Vol. 148 (1) , 17
Open AccessBiomechanical Assessment of Walking in Simulated Low-Vision Conditions Using a Visual Aid Device
Low vision is a major factor limiting mobility and increasing the risk of falls globally, with a significant impact on quality of life. The article presents the analysis of the effects of simulated visual dysfunctions—cataract and glaucoma—on the biomechanical parameters of gait and evaluates the effectiveness of a portable device based on ultrasonic sensors, called the Tridirectional Device. A sample of 25 clinically healthy subjects was evaluated in five experimental conditions, using a plantar pressure distribution analysis system (RSScan), the Tinetti scale and the center of pressure trajectory analysis. The results highlight changes in gait parameters under the conditions of use of the device, suggesting its potential as an accessible and non-invasive solution for supporting people with visual impairments.
- 4 June 2026
- Published by Springer Nature
- p. 331-339
Personalization of Visual Assistive Devices for People with Low Vision Using 3D Printing Technology
- 4 June 2026
- Published by Springer Nature
- p. 331-339
Personalization of Visual Assistive Devices for People with Low Vision Using 3D Printing Technology
- 1 October 2025
- Published by Springer Nature
- p. 492-502
Protocol Developing for Visual Function Testing Efficiency Increasing for Regular and Professional Drivers
- 1 October 2025
- Published by Springer Nature
- p. 492-502
Protocol Developing for Visual Function Testing Efficiency Increasing for Regular and Professional Drivers
- 2 August 2025
- Published by Springer Nature
- p. 13-22
Conceptual Model of an Eye Movement Simulation Procedure for Motor Dysfunction Prediction
- 2 August 2025
- Published by Springer Nature
- p. 13-22
Conceptual Model of an Eye Movement Simulation Procedure for Motor Dysfunction Prediction
- 2 August 2025
- Published by Springer Nature
- p. 235-240
Foot Drop Orthosis, Low Cost, with Thermoplastic
- 2 August 2025
- Published by Springer Nature
- p. 65-77
Low Cost Thermic System for Transfusable Substance Improving
- 2 August 2025
- Published by Springer Nature
- p. 65-77
Low Cost Thermic System for Transfusable Substance Improving
- 2 August 2025
- Published by Springer Nature
- p. 78-83
Measuring Angle with an Arduino Based Device for a Foot Drop Orthosis Adjustment
- 2 August 2025
- Published by Springer Nature
- p. 78-83
Measuring Angle with an Arduino Based Device for a Foot Drop Orthosis Adjustment