Mitu Leonard
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Mitu Leonard has a total of 13 co-authors. Here are the top co-authors by number of shared publications:
- Barbu Cristian Braun
Transilvania University of Brasov
4 shared publications - Corneliu Nicolae Drugă
Transilvania University of Brasov
4 shared publications - Ionel Șerban
Transilvania University of Brasov
4 shared publications - Angela Repanovici
Faculty of Product Design and Environment, Transilvania University of Brasov, 500036 Brasov, Romania
2 shared publications - Adrian-Petru Pop1 shared publication
- Bejinaru Mihoc Gheorghe1 shared publication
Latest Publications
- Open Access
Design-Stage Feasibility Study of an Integrated 3D-Printed Nerve Conduit and Portable Monitoring System
(1) Background: Peripheral nerve repair requires structural guidance and reliable functional assessment, yet current commercial conduits lack internal microarchitecture and do not integrate real-time monitoring capabilities. This study presents an engineering-focused feasibility assessment of a dual system combining a microstructured 3D-printed nerve guidance conduit with a portable neuromuscular monitoring device. (2) Methods: Two conduit variants were digitally designed based on median nerve anatomical dimensions and fabricated using FDM (PLA) for large-scale prototypes and SLA for high-resolution miniaturized models. Structural behavior was evaluated through simplified finite element analysis (FEA) under physiological pressure ranges (1000–5000 Pa). A portable monitoring system incorporating surface EMG electrodes, an AD620 instrumentation amplifier, and an ESP32 microcontroller was assembled and tested non-invasively on a healthy adult volunteer to verify signal acquisition functionality. Results: Both conduit designs were successfully fabricated with accurate reproduction of internal microchannels. FEA indicated negligible deformation (1.41 × 10−11–1.69 × 10−10 mm) and low stress values (0.0129–0.155 N/m2), confirming structural stability under the simplified loading model. The monitoring system recorded stable EMG signals (3200–3500 ADC units), demonstrating correct operation of the acquisition chain during controlled stimulation. (3) Conclusions: This work provides a design-stage engineering feasibility demonstration of an integrated platform combining a microstructured 3D-printed conduit with a portable neuromuscular monitoring device. The study does not include biological validation; prototypes were evaluated solely for geometric and mechanical fidelity; and the monitoring system was tested only for functional signal acquisition. Future work will address biocompatibility, in vitro assays, and in vivo evaluation.
Open AccessDesign-Stage Feasibility Study of an Integrated 3D-Printed Nerve Conduit and Portable Monitoring System
(1) Background: Peripheral nerve repair requires structural guidance and reliable functional assessment, yet current commercial conduits lack internal microarchitecture and do not integrate real-time monitoring capabilities. This study presents an engineering-focused feasibility assessment of a dual system combining a microstructured 3D-printed nerve guidance conduit with a portable neuromuscular monitoring device. (2) Methods: Two conduit variants were digitally designed based on median nerve anatomical dimensions and fabricated using FDM (PLA) for large-scale prototypes and SLA for high-resolution miniaturized models. Structural behavior was evaluated through simplified finite element analysis (FEA) under physiological pressure ranges (1000–5000 Pa). A portable monitoring system incorporating surface EMG electrodes, an AD620 instrumentation amplifier, and an ESP32 microcontroller was assembled and tested non-invasively on a healthy adult volunteer to verify signal acquisition functionality. Results: Both conduit designs were successfully fabricated with accurate reproduction of internal microchannels. FEA indicated negligible deformation (1.41 × 10−11–1.69 × 10−10 mm) and low stress values (0.0129–0.155 N/m2), confirming structural stability under the simplified loading model. The monitoring system recorded stable EMG signals (3200–3500 ADC units), demonstrating correct operation of the acquisition chain during controlled stimulation. (3) Conclusions: This work provides a design-stage engineering feasibility demonstration of an integrated platform combining a microstructured 3D-printed conduit with a portable neuromuscular monitoring device. The study does not include biological validation; prototypes were evaluated solely for geometric and mechanical fidelity; and the monitoring system was tested only for functional signal acquisition. Future work will address biocompatibility, in vitro assays, and in vivo evaluation.
- Open Access
- 7 August 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (30)
Innovations in Drug Administration: NonInvasive Solutions for Diabetes Treatment Through the Development of Advanced Biosensors
This study explores innovations in drug administration monitoring, focusing on novel materials and technologies aimed at enhancing diabetes treatment. While injectable insulin remains the standard therapy, many patients are reluctant to use it, hindering treatment adherence. To address this, the research investigates alternative insulin delivery methods that are more acceptable to patients and support better compliance. Current noninvasive solutions such as transdermal patches, micropumps, and microneedle systems are reviewed. Key scientific literature and patents showcasing advances in noninvasive insulin delivery are analyzed. Building on these findings, the paper proposes a novel glucose biosensor composed of thermoplastic starch (TPS) integrated with silver nanoparticles (AgNPs) and the glucose oxidase (GOx) enzyme.
- 7 August 2025
- Published by Wiley in ChemistrySelect
- Vol. 10 (30)
Open AccessInnovations in Drug Administration: NonInvasive Solutions for Diabetes Treatment Through the Development of Advanced Biosensors
This study explores innovations in drug administration monitoring, focusing on novel materials and technologies aimed at enhancing diabetes treatment. While injectable insulin remains the standard therapy, many patients are reluctant to use it, hindering treatment adherence. To address this, the research investigates alternative insulin delivery methods that are more acceptable to patients and support better compliance. Current noninvasive solutions such as transdermal patches, micropumps, and microneedle systems are reviewed. Key scientific literature and patents showcasing advances in noninvasive insulin delivery are analyzed. Building on these findings, the paper proposes a novel glucose biosensor composed of thermoplastic starch (TPS) integrated with silver nanoparticles (AgNPs) and the glucose oxidase (GOx) enzyme.
- 2 August 2025
- Published by Springer Nature
- p. 65-77
Low Cost Thermic System for Transfusable Substance Improving
- 2 August 2025
- Published by Springer Nature
- p. 65-77
Low Cost Thermic System for Transfusable Substance Improving
- 2 August 2025
- Published by Springer Nature
- p. 162-179
Modern Methods of Visual Training for Children with Strabismus and Amblyopia Through Assisted Serious Games
- 2 August 2025
- Published by Springer Nature
- p. 162-179
Modern Methods of Visual Training for Children with Strabismus and Amblyopia Through Assisted Serious Games
- 9 January 2024
- Published by Springer Nature
- p. 77-86
Assisted Assessment of Visual Stress – Method to Prevent and Reduce the Risk of Visual Function Loss
- 9 January 2024
- Published by Springer Nature
- p. 77-86
Assisted Assessment of Visual Stress – Method to Prevent and Reduce the Risk of Visual Function Loss
- 14 September 2023
- Published by Springer Nature
- p. 308-317
Non Conventional Methods in Visual Function Training for Children with Sight Disabilities
- 14 September 2023
- Published by Springer Nature
- p. 308-317
Non Conventional Methods in Visual Function Training for Children with Sight Disabilities
- Open Access
Kane’s Formalism Used to the Vibration Analysis of a Wind Water Pump
The paper uses Kane’s formalism to study two degrees of freedom (DOF) mechanisms with elastic elements = employed in a wind water pump. This formalism represents an alternative, in our opinion, that is simpler and more economical to Lagrange’s equation, used mainly by researchers in this type of application. In the problems where the finite element method (FEM) is applied, Kane’s equations were not used at all. The automated computation causes it to be reconsidered in the case of mechanical systems with a high DOF. Analyzing the planar transmission mechanism, these equations were applied for the study of an elastic element. An analysis was then made of the results obtained for this type of water pump. The matrices coefficients of the obtained equations were symmetric or skew-symmetric.
Open AccessKane’s Formalism Used to the Vibration Analysis of a Wind Water Pump
The paper uses Kane’s formalism to study two degrees of freedom (DOF) mechanisms with elastic elements = employed in a wind water pump. This formalism represents an alternative, in our opinion, that is simpler and more economical to Lagrange’s equation, used mainly by researchers in this type of application. In the problems where the finite element method (FEM) is applied, Kane’s equations were not used at all. The automated computation causes it to be reconsidered in the case of mechanical systems with a high DOF. Analyzing the planar transmission mechanism, these equations were applied for the study of an elastic element. An analysis was then made of the results obtained for this type of water pump. The matrices coefficients of the obtained equations were symmetric or skew-symmetric.
- Open Access
- 1 January 2011
- Published by Asociatia Pentru Inginerie Integrata si Management Industrial in ANNALS OF THE ORADEA UNIVERSITY. Fascicle of Management and Technological Engineering.
- Vol. XX (X), 20 (2)
THE SYSTEMIC ANALYSIS OF METALS MANUFACTURING USED IN MEMS FABRICATION
- 1 January 2011
- Published by Asociatia Pentru Inginerie Integrata si Management Industrial in ANNALS OF THE ORADEA UNIVERSITY. Fascicle of Management and Technological Engineering.
- Vol. XX (X), 20 (2)
Open AccessTHE SYSTEMIC ANALYSIS OF METALS MANUFACTURING USED IN MEMS FABRICATION