Arushri Swarup
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Arushri Swarup has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Hani E. Naguib
Department of Mechanical and Industrial Engineering, University of Toronto, 5 King’s College Road, Toronto, Ontario M5S 3G8, Canada
2 shared publications - James Christopher Bouwmeester
University of Toronto
2 shared publications - James Mbbs Drake
Wilfred and Joyce Posluns Centre for Image Guided Innovation and Therapeutic Intervention, Hospital for Sick Children, Toronto, ON, Canada
2 shared publications - Kyle W. Eastwood
Department of Emergency Medicine, Dalhousie University, Halifax, Canada
2 shared publications - Peter Francis
Center for Image Guided Innovation and Therapeutic Intervention (CIGITI), The Hospital for Sick Children, 555 University Avenue, Toronto, ON M5G 1X8, Canada
2 shared publications - Thomas Looi
Center for Image Guided Innovation and Therapeutic Intervention (CIGITI), The Hospital for Sick Children, 555 University Avenue, Toronto, ON M5G 1X8, Canada
2 shared publications
Latest Publications
- 16 November 2020
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 45 (1) , 22-34
Design, prototype development and pre-clinical validation of a novel instrument with a compliant steerable tip to facilitate endoscopic ear surgery
This work presents the design of a novel compliant steerable tip (CST) instrument to facilitate transcanal (or totally) endoscopic ear surgery (TEES). The evolution of the instrument’s design is shown, where prototypes were evaluated by surgeons and their feedback was used to inform the design changes for the next prototype iteration. The final prototype enables the surgeon to articulate the compliant tip to achieve the desired bending curvature while automatically locking in place and providing dissection and suction capabilities. Pre-clinical validation testing was performed in goat and human cadaver models by two surgeons who successfully removed an allograft from the middle ear. Time and the number of blockages while suctioning saline in both cadaver models were measured and compared with current instruments used during TEES. The CST took significantly less time to suction saline within a flooded middle ear compared to the Panetti suction dissector (PSD) for atticus and underwent less blockages than the PSD for atticus, ear drum and sinus tympani instruments, Wilcoxon Method p < .05. Our study demonstrates the development and successful clinical evaluation of a minimally invasive surgical instrument designed to facilitate endoscopic approaches to the ear.
- 16 November 2020
- Published by Taylor & Francis in Journal of Medical Engineering & Technology
- Vol. 45 (1) , 22-34
Design, prototype development and pre-clinical validation of a novel instrument with a compliant steerable tip to facilitate endoscopic ear surgery
This work presents the design of a novel compliant steerable tip (CST) instrument to facilitate transcanal (or totally) endoscopic ear surgery (TEES). The evolution of the instrument’s design is shown, where prototypes were evaluated by surgeons and their feedback was used to inform the design changes for the next prototype iteration. The final prototype enables the surgeon to articulate the compliant tip to achieve the desired bending curvature while automatically locking in place and providing dissection and suction capabilities. Pre-clinical validation testing was performed in goat and human cadaver models by two surgeons who successfully removed an allograft from the middle ear. Time and the number of blockages while suctioning saline in both cadaver models were measured and compared with current instruments used during TEES. The CST took significantly less time to suction saline within a flooded middle ear compared to the Panetti suction dissector (PSD) for atticus and underwent less blockages than the PSD for atticus, ear drum and sinus tympani instruments, Wilcoxon Method p < .05. Our study demonstrates the development and successful clinical evaluation of a minimally invasive surgical instrument designed to facilitate endoscopic approaches to the ear.
- 18 February 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (2)
A Steerable Neuroendoscopic Instrument Using Compliant Contact-Aided Joints and Monolithic Articulation
This work presents the design of an articulate neuroendoscopic instrument (ANI), a handheld tool for use in minimally invasive neurosurgery. The instrument consists of a handle and a steerable tube-shaft with a distal end-effector. The design aims to increase the reach of surgeons operating through narrow channels within the center of the brain when approaching multiple targets from a single incision point. The steerable tube-shaft consists of a 1.6- mm notch-tube compliant joint mechanism augmented with contact-aids modeled after a gear geometry. The contact-aid geometry aims to address the performance tradeoff between stiffness, range-of-motion (RoM), and joint compactness for millimeter-scale notched-tube joints; it increases blocking force without sacrificing RoM. Finite element modeling (FEM) was used to refine design features, and the joint stiffness and RoM are assessed experimentally for three prototypes. The joint is incorporated into a tube-shaft instrument, and the assembled tool's stiffness properties are characterized. The prototype was then assessed in a validated neurosurgical simulator. An individual 1.24-mm outer-diameter notch-tube compliant joint with gear contact-aids is capable of 30 deg maximum bending and can sustain a 0.55 N blocking force with 0.5 mm displacement. A functional instrument shaft with a 15.5- mm-long articulating section was constructed from three joints in series with an external flexible stainless-steel sheath. It achieves a 6.7-mm bending radius at 75 deg maximum bending angle. In preclinical testing with an endoscopic third ventriculostomy and endoscopic tumor biopsy (ETV-ETB) simulator, the tool successfully completes the biopsy and fenestration maneuvers from a single burr-hole entry point. The ANI prototype uses contact-aid geometry incorporated into a compliant nitinol notched-tube joint to produce an articulate biopsy instrument for minimally invasive neurosurgical applications.
- 18 February 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (2)
A Steerable Neuroendoscopic Instrument Using Compliant Contact-Aided Joints and Monolithic Articulation
This work presents the design of an articulate neuroendoscopic instrument (ANI), a handheld tool for use in minimally invasive neurosurgery. The instrument consists of a handle and a steerable tube-shaft with a distal end-effector. The design aims to increase the reach of surgeons operating through narrow channels within the center of the brain when approaching multiple targets from a single incision point. The steerable tube-shaft consists of a 1.6- mm notch-tube compliant joint mechanism augmented with contact-aids modeled after a gear geometry. The contact-aid geometry aims to address the performance tradeoff between stiffness, range-of-motion (RoM), and joint compactness for millimeter-scale notched-tube joints; it increases blocking force without sacrificing RoM. Finite element modeling (FEM) was used to refine design features, and the joint stiffness and RoM are assessed experimentally for three prototypes. The joint is incorporated into a tube-shaft instrument, and the assembled tool's stiffness properties are characterized. The prototype was then assessed in a validated neurosurgical simulator. An individual 1.24-mm outer-diameter notch-tube compliant joint with gear contact-aids is capable of 30 deg maximum bending and can sustain a 0.55 N blocking force with 0.5 mm displacement. A functional instrument shaft with a 15.5- mm-long articulating section was constructed from three joints in series with an external flexible stainless-steel sheath. It achieves a 6.7-mm bending radius at 75 deg maximum bending angle. In preclinical testing with an endoscopic third ventriculostomy and endoscopic tumor biopsy (ETV-ETB) simulator, the tool successfully completes the biopsy and fenestration maneuvers from a single burr-hole entry point. The ANI prototype uses contact-aid geometry incorporated into a compliant nitinol notched-tube joint to produce an articulate biopsy instrument for minimally invasive neurosurgical applications.
- 1 July 2018
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 39 (6) , 778-784
The Current Limitations and Future Direction of Instrument Design for Totally Endoscopic Ear Surgery: a Needs Analysis Survey
This study aimed to identify limitations and challenges associated with existing instruments and techniques used in totally endoscopic ear surgery (TEES). Otologic instruments, traditionally developed for two-handed surgery with operating microscopes, are not necessarily optimized for the TEES environment. Better understanding of technical challenges and the limitations of current instrumentation may allow advances in instrument design for TEES surgery. This cross-sectional study employed a mixed-methods nine-question survey that was distributed internationally to surgeons with an interest in TEES. Respondents were asked to classify their TEES experience and instrumentation used, rate their need for better instrumentation to address six TEES-related challenges using visual analog scales, and comment on how to modify or develop new instrumentation. With 51 respondents, we quantified a need for better instruments to address the following 6 potential TEES challenges ordered from greatest to least need: 1) reaching structures visualized by the endoscope, 2) dissection and removal of cholesteatoma, 3) cutting and/or removing bone, 4) bleeding control, 5) keeping the endoscope lens clean, 6) moving and positioning a graft into the intended place. The majority of surgeons perceive a need for improved instrumentation to address each challenge. Challenges 1) and 2) were associated with significantly greater need than the others (p < 0.05, Wilcoxon method for nonparametric pairwise comparisons). In addition to highlighting and quantifying some of the common TEES challenges, these findings provide valuable insight into the design requirements for developing improved surgical instrumentation and techniques.
- 1 July 2018
- Published by Wolters Kluwer Health in Otology & Neurotology
- Vol. 39 (6) , 778-784
The Current Limitations and Future Direction of Instrument Design for Totally Endoscopic Ear Surgery: a Needs Analysis Survey
This study aimed to identify limitations and challenges associated with existing instruments and techniques used in totally endoscopic ear surgery (TEES). Otologic instruments, traditionally developed for two-handed surgery with operating microscopes, are not necessarily optimized for the TEES environment. Better understanding of technical challenges and the limitations of current instrumentation may allow advances in instrument design for TEES surgery. This cross-sectional study employed a mixed-methods nine-question survey that was distributed internationally to surgeons with an interest in TEES. Respondents were asked to classify their TEES experience and instrumentation used, rate their need for better instrumentation to address six TEES-related challenges using visual analog scales, and comment on how to modify or develop new instrumentation. With 51 respondents, we quantified a need for better instruments to address the following 6 potential TEES challenges ordered from greatest to least need: 1) reaching structures visualized by the endoscope, 2) dissection and removal of cholesteatoma, 3) cutting and/or removing bone, 4) bleeding control, 5) keeping the endoscope lens clean, 6) moving and positioning a graft into the intended place. The majority of surgeons perceive a need for improved instrumentation to address each challenge. Challenges 1) and 2) were associated with significantly greater need than the others (p < 0.05, Wilcoxon method for nonparametric pairwise comparisons). In addition to highlighting and quantifying some of the common TEES challenges, these findings provide valuable insight into the design requirements for developing improved surgical instrumentation and techniques.
- Open Access
- 23 February 2018
- Published by Queen's University Library in Proceedings of the Canadian Engineering Education Association (CEEA)
Using a Multidisciplinary Team-Based Challenge to Promote Brainstorming and Prototyping of Medical Devices
Abstract – Multidisciplinary teams of engineering and life science students are challenged to remove a foreign object from a child’s ear canal. Each group is provided with a model ear canal and asked to remove objects of different shapes and materials. The experience of iterative problem solving serves to encourage brainstorming and practice the prototyping process, which each team should complete in their over-arching design projects to be successful. Surveys taken from the students before and after the prototype challenge showed they learned more about the brainstorming method they used, but also learned what worked well for other groups. Student feedback indicates that this activity prepared them to be creative and tackle the larger challenge of developing a solution to their own design project as part of the Biomedical Engineering Capstone Design course.
- 23 February 2018
- Published by Queen's University Library in Proceedings of the Canadian Engineering Education Association (CEEA)
Open AccessUsing a Multidisciplinary Team-Based Challenge to Promote Brainstorming and Prototyping of Medical Devices
Abstract – Multidisciplinary teams of engineering and life science students are challenged to remove a foreign object from a child’s ear canal. Each group is provided with a model ear canal and asked to remove objects of different shapes and materials. The experience of iterative problem solving serves to encourage brainstorming and practice the prototyping process, which each team should complete in their over-arching design projects to be successful. Surveys taken from the students before and after the prototype challenge showed they learned more about the brainstorming method they used, but also learned what worked well for other groups. Student feedback indicates that this activity prepared them to be creative and tackle the larger challenge of developing a solution to their own design project as part of the Biomedical Engineering Capstone Design course.
- Open Access
- 22 February 2018
- Published by Queen's University Library in Proceedings of the Canadian Engineering Education Association (CEEA)
Using Role-Playing Simulations to Teach Quality Control in the Design of Medical Devices
Abstract – A simulation is used to facilitate cooperative and team-based learning to introduce concepts of human factors, risk analysis, and quality control applied to the design of medical devices. We further use a friendly game-based approach to simulate the dynamics between a customer, a regulatory agency, and competitive manufacturers. Students are divided into manufacturing teams/companies and teaching assistants act as the customer and regulator. To promote positive interdependence and individual accountability, each student within a company is assigned roles of CEO, inspector, marketer, and designer. The goal for each company is to design and produce as many eye patch medical devices as possible, which must be approved by the regulator, within a tight deadline. Products are evaluated by the customer, who decides what price to pay for each unit, at the end of production. The most successful company is determined by the greatest amount of money earned after two rounds of production and sales.
- 22 February 2018
- Published by Queen's University Library in Proceedings of the Canadian Engineering Education Association (CEEA)
Open AccessUsing Role-Playing Simulations to Teach Quality Control in the Design of Medical Devices
Abstract – A simulation is used to facilitate cooperative and team-based learning to introduce concepts of human factors, risk analysis, and quality control applied to the design of medical devices. We further use a friendly game-based approach to simulate the dynamics between a customer, a regulatory agency, and competitive manufacturers. Students are divided into manufacturing teams/companies and teaching assistants act as the customer and regulator. To promote positive interdependence and individual accountability, each student within a company is assigned roles of CEO, inspector, marketer, and designer. The goal for each company is to design and produce as many eye patch medical devices as possible, which must be approved by the regulator, within a tight deadline. Products are evaluated by the customer, who decides what price to pay for each unit, at the end of production. The most successful company is determined by the greatest amount of money earned after two rounds of production and sales.
- Open Access
- 20 December 2017
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 10 (1) , 015001
Design of a Contact-Aided Compliant Notched-Tube Joint for Surgical Manipulation in Confined Workspaces
This work presents a novel miniature contact-aided compliant joint mechanism that can be integrated into millimeter-sized manual or robotic surgical instruments. The design aims to address the trade-off between notched-tube compliant joints' range of motion and stiffness, while also ensuring a compact form factor. The mechanism is constructed from a nitinol tube with asymmetric cutouts and is actuated in bending by a cable. The innovative feature of this design is the incorporation of a contact aid into the notched-tube topology, which acts to both increase the stiffness of the joint and change the shape that it undertakes during bending. Using finite element modeling (FEM) techniques, we present a sensitivity analysis investigating how the performance of this contact-aided compliant mechanism (CCM) is affected by its geometry, and derive a kinematics and statics model for the joint. The FEM simulations and the kinematic and static models are compared to experimental results. The design and modeling presented in this study can be used to develop new miniature dexterous instruments, with a particular emphasis on applications in minimally invasive neurosurgery.
- 20 December 2017
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 10 (1) , 015001
Open AccessDesign of a Contact-Aided Compliant Notched-Tube Joint for Surgical Manipulation in Confined Workspaces
This work presents a novel miniature contact-aided compliant joint mechanism that can be integrated into millimeter-sized manual or robotic surgical instruments. The design aims to address the trade-off between notched-tube compliant joints' range of motion and stiffness, while also ensuring a compact form factor. The mechanism is constructed from a nitinol tube with asymmetric cutouts and is actuated in bending by a cable. The innovative feature of this design is the incorporation of a contact aid into the notched-tube topology, which acts to both increase the stiffness of the joint and change the shape that it undertakes during bending. Using finite element modeling (FEM) techniques, we present a sensitivity analysis investigating how the performance of this contact-aided compliant mechanism (CCM) is affected by its geometry, and derive a kinematics and statics model for the joint. The FEM simulations and the kinematic and static models are compared to experimental results. The design and modeling presented in this study can be used to develop new miniature dexterous instruments, with a particular emphasis on applications in minimally invasive neurosurgery.