Peter Francis
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Peter Francis has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
- Kyle W. Eastwood
Department of Emergency Medicine, Dalhousie University, Halifax, Canada
4 shared publications - Arushri Swarup
Center for Image Guided Innovation and Therapeutic Intervention (CIGITI), The Hospital for Sick Children, 555 University Avenue, Toronto, ON M5G 1X8, Canada
2 shared publications - Hani E. Naguib
Department of Mechanical and Industrial Engineering, University of Toronto, 5 King’s College Road, Toronto, Ontario M5S 3G8, Canada
2 shared publications James Drake
The Wilfred and Joyce Posluns Centre for Image-Guided Innovation and Therapeutic Intervention, The Hospital for Sick Children, Toronto, Canada
2 shared publications- James Mbbs Drake
Wilfred and Joyce Posluns Centre for Image Guided Innovation and Therapeutic Intervention, Hospital for Sick Children, Toronto, ON, Canada
2 shared publications - Thomas Looi
Center for Image Guided Innovation and Therapeutic Intervention (CIGITI), The Hospital for Sick Children, 555 University Avenue, Toronto, ON M5G 1X8, Canada
2 shared publications
Latest Publications
- 6 November 2023
- Published by Oxford University Press (OUP) in Brain
- Vol. 147 (4) , 1264-1277
The clinical, imaging, pathological and genetic landscape of bottom-of-sulcus dysplasia
Bottom-of-sulcus dysplasia (BOSD) is increasingly recognised as a cause of drug-resistant, surgically-remediable, focal epilepsy, often in seemingly MRI-negative patients. We describe the clinical manifestations, morphological features, localisation patterns, and genetics of BOSD, with the aims of improving management and understanding pathogenesis. We studied 85 patients with BOSD diagnosed between 2005-2022. Presenting seizure and EEG characteristics, clinical course, genetic findings, and treatment response were obtained from medical records. 3T-MRI and 18F-FDG-PET scans were reviewed systematically for BOSD morphology and metabolism. Histopathological analysis and tissue genetic testing were performed in 64 operated patients. BOSD locations were transposed to common imaging space to study anatomical location, functional network localisation, and relationship to normal MTOR gene expression. All patients presented with stereotyped focal seizures with rapidly escalating frequency, prompting hospitalisation in 48%. Despite 42% patients having seizure remissions, usually with sodium channel blocking medications, most eventually became drug-resistant and underwent surgery (86% seizure-free). Prior developmental delay was uncommon but intellectual, language and executive dysfunction were present in 24%, 48% and 29% when assessed preoperatively, low intellect being associated with greater epilepsy duration. BOSDs were missed on initial MRI in 68%, being ultimately recognised following repeat MRI, 18F-FDG-PET or image post-processing. MRI features were grey-white junction blurring (100%), cortical thickening (91%), transmantle band (62%), increased cortical T1 signal (46%) and increased subcortical FLAIR signal (26%). BOSD hypometabolism was present on 18F-FDG-PET in 99%. Additional areas of cortical malformation or grey matter heterotopia were present in eight patients. BOSDs predominated in frontal and pericentral cortex and related functional networks, mostly sparing temporal and occipital cortex, and limbic and visual networks. Genetic testing yielded pathogenic mTOR pathway variants in 63% patients, including somatic MTOR variants in 47% operated patients and germline DEPDC5 or NPRL3 variants in 73% patients with familial focal epilepsy. BOSDs tended to occur in regions where the healthy brain normally shows lower MTOR expression, suggesting these regions may be more vulnerable to up-regulation of MTOR activity. Consistent with the existing literature, these results highlight (1) clinical features raising suspicion of BOSD, (2) the role of somatic and germline mTOR pathway variants in patients with sporadic and familial focal epilepsy associated with BOSD and (3) the role of 18F-FDG-PET alongside high-field MRI in detecting subtle BOSD. The anatomical and functional distribution of BOSDs likely explain their seizure, EEG, and cognitive manifestations, and may relate to relative MTOR expression.
- 6 November 2023
- Published by Oxford University Press (OUP) in Brain
- Vol. 147 (4) , 1264-1277
The clinical, imaging, pathological and genetic landscape of bottom-of-sulcus dysplasia
Bottom-of-sulcus dysplasia (BOSD) is increasingly recognised as a cause of drug-resistant, surgically-remediable, focal epilepsy, often in seemingly MRI-negative patients. We describe the clinical manifestations, morphological features, localisation patterns, and genetics of BOSD, with the aims of improving management and understanding pathogenesis. We studied 85 patients with BOSD diagnosed between 2005-2022. Presenting seizure and EEG characteristics, clinical course, genetic findings, and treatment response were obtained from medical records. 3T-MRI and 18F-FDG-PET scans were reviewed systematically for BOSD morphology and metabolism. Histopathological analysis and tissue genetic testing were performed in 64 operated patients. BOSD locations were transposed to common imaging space to study anatomical location, functional network localisation, and relationship to normal MTOR gene expression. All patients presented with stereotyped focal seizures with rapidly escalating frequency, prompting hospitalisation in 48%. Despite 42% patients having seizure remissions, usually with sodium channel blocking medications, most eventually became drug-resistant and underwent surgery (86% seizure-free). Prior developmental delay was uncommon but intellectual, language and executive dysfunction were present in 24%, 48% and 29% when assessed preoperatively, low intellect being associated with greater epilepsy duration. BOSDs were missed on initial MRI in 68%, being ultimately recognised following repeat MRI, 18F-FDG-PET or image post-processing. MRI features were grey-white junction blurring (100%), cortical thickening (91%), transmantle band (62%), increased cortical T1 signal (46%) and increased subcortical FLAIR signal (26%). BOSD hypometabolism was present on 18F-FDG-PET in 99%. Additional areas of cortical malformation or grey matter heterotopia were present in eight patients. BOSDs predominated in frontal and pericentral cortex and related functional networks, mostly sparing temporal and occipital cortex, and limbic and visual networks. Genetic testing yielded pathogenic mTOR pathway variants in 63% patients, including somatic MTOR variants in 47% operated patients and germline DEPDC5 or NPRL3 variants in 73% patients with familial focal epilepsy. BOSDs tended to occur in regions where the healthy brain normally shows lower MTOR expression, suggesting these regions may be more vulnerable to up-regulation of MTOR activity. Consistent with the existing literature, these results highlight (1) clinical features raising suspicion of BOSD, (2) the role of somatic and germline mTOR pathway variants in patients with sporadic and familial focal epilepsy associated with BOSD and (3) the role of 18F-FDG-PET alongside high-field MRI in detecting subtle BOSD. The anatomical and functional distribution of BOSDs likely explain their seizure, EEG, and cognitive manifestations, and may relate to relative MTOR expression.
- 5 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (4) , 889-900
Design and Performance Evaluation of a Novel Compliant Wrist for Minimally Invasive Middle Ear Surgery
Objective: To present the design choices, modelling of bending stiffness and experimental validation of a novel notched Nitinol compliant wrist that enables tip articulation and suction during endoscopic and robotic middle ear surgery. Methods: The wrist consists of an inner wrist tube (IWT) assembled within an outer wrist tube (OWT). The OWT was selected from five concept designs that were evaluated based on stiffness and compact bending. An analytical model was developed based on Castigliano’s 2nd Theorem and a finite element model (FEM) was developed to predict tip stiffness under soft-tissue surgical interactions and compared to experimental results. Results: The FEM and analytical models predicted tip displacement due to an applied force within 25% and 12 % of the experimental results, respectively. The complete wrist prototype withstood 700-1000 cycles before fracture when it was articulated up to 145∘ -178∘, corresponding to 9.6 N -12.4 N of cable tension. Conclusion: A wristed tool is presented to facilitate endoscopic ear surgery and its mechanical behaviour in surgically relevant loading conditions. Significance: This instrument could be adapted to provide suction and soft tissue dissection capabilities for future minimally invasive endoscopic or robotic surgery, through the ear canal or other natural orifices.
- 5 August 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Robotics and Bionics
- Vol. 4 (4) , 889-900
Design and Performance Evaluation of a Novel Compliant Wrist for Minimally Invasive Middle Ear Surgery
Objective: To present the design choices, modelling of bending stiffness and experimental validation of a novel notched Nitinol compliant wrist that enables tip articulation and suction during endoscopic and robotic middle ear surgery. Methods: The wrist consists of an inner wrist tube (IWT) assembled within an outer wrist tube (OWT). The OWT was selected from five concept designs that were evaluated based on stiffness and compact bending. An analytical model was developed based on Castigliano’s 2nd Theorem and a finite element model (FEM) was developed to predict tip stiffness under soft-tissue surgical interactions and compared to experimental results. Results: The FEM and analytical models predicted tip displacement due to an applied force within 25% and 12 % of the experimental results, respectively. The complete wrist prototype withstood 700-1000 cycles before fracture when it was articulated up to 145∘ -178∘, corresponding to 9.6 N -12.4 N of cable tension. Conclusion: A wristed tool is presented to facilitate endoscopic ear surgery and its mechanical behaviour in surgically relevant loading conditions. Significance: This instrument could be adapted to provide suction and soft tissue dissection capabilities for future minimally invasive endoscopic or robotic surgery, through the ear canal or other natural orifices.
- Open Access
- 22 March 2021
- Published by Springer Nature in Cancer Chemotherapy and Pharmacology
- Vol. 88 (1) , 25-37
Niraparib with androgen receptor-axis-targeted therapy in patients with metastatic castration-resistant prostate cancer: safety and pharmacokinetic results from a phase 1b study (BEDIVERE)
Purpose: To assess the safety and pharmacokinetics and determine the recommended phase 2 dose (RP2D) of niraparib with apalutamide or abiraterone acetate plus prednisone (AAP) in patients with metastatic castration-resistant prostate cancer (mCRPC). Methods: BEDIVERE was a multicenter, open-label, phase 1b study of niraparib 200 or 300 mg/day with apalutamide 240 mg or AAP (abiraterone acetate 1000 mg; prednisone 10 mg). Patients with mCRPC were previously treated with ≥ 2 lines of systemic therapy, including ≥ 1 androgen receptor-axis-targeted therapy for prostate cancer. Results: Thirty-three patients were enrolled (niraparib-apalutamide, 6; niraparib-AAP, 27). No dose-limiting toxicities (DLTs) were reported when combinations included niraparib 200 mg; five patients receiving niraparib 300 mg experienced DLTs [niraparib-apalutamide, 2/3 patients (66.7%); niraparib-AAP, 3/8 patients (37.5%)]. Although data are limited, niraparib exposures were lower when given with apalutamide compared with historical niraparib monotherapy exposures in patients with solid tumors. Because of the higher incidence of DLTs, the niraparib–apalutamide combination and niraparib 300 mg combination with AAP were not further evaluated. Niraparib 200 mg was selected as the RP2D with AAP. Of 19 patients receiving niraparib 200 mg with AAP, 12 (63.2%) had grade 3/4 treatment-emergent adverse events, the most common being thrombocytopenia (26.3%) and hypertension (21.1%). Five patients (26.3%) had adverse events leading to treatment discontinuation. Conclusions: These results support the choice of niraparib 200 mg as the RP2D with AAP. The niraparib–AAP combination was tolerable in patients with mCRPC, with no new safety signals. An ongoing phase 3 study is further assessing this combination in patients with mCRPC. Trial registration no.: NCT02924766 (ClinicalTrials.gov).
- 22 March 2021
- Published by Springer Nature in Cancer Chemotherapy and Pharmacology
- Vol. 88 (1) , 25-37
Open AccessNiraparib with androgen receptor-axis-targeted therapy in patients with metastatic castration-resistant prostate cancer: safety and pharmacokinetic results from a phase 1b study (BEDIVERE)
Purpose: To assess the safety and pharmacokinetics and determine the recommended phase 2 dose (RP2D) of niraparib with apalutamide or abiraterone acetate plus prednisone (AAP) in patients with metastatic castration-resistant prostate cancer (mCRPC). Methods: BEDIVERE was a multicenter, open-label, phase 1b study of niraparib 200 or 300 mg/day with apalutamide 240 mg or AAP (abiraterone acetate 1000 mg; prednisone 10 mg). Patients with mCRPC were previously treated with ≥ 2 lines of systemic therapy, including ≥ 1 androgen receptor-axis-targeted therapy for prostate cancer. Results: Thirty-three patients were enrolled (niraparib-apalutamide, 6; niraparib-AAP, 27). No dose-limiting toxicities (DLTs) were reported when combinations included niraparib 200 mg; five patients receiving niraparib 300 mg experienced DLTs [niraparib-apalutamide, 2/3 patients (66.7%); niraparib-AAP, 3/8 patients (37.5%)]. Although data are limited, niraparib exposures were lower when given with apalutamide compared with historical niraparib monotherapy exposures in patients with solid tumors. Because of the higher incidence of DLTs, the niraparib–apalutamide combination and niraparib 300 mg combination with AAP were not further evaluated. Niraparib 200 mg was selected as the RP2D with AAP. Of 19 patients receiving niraparib 200 mg with AAP, 12 (63.2%) had grade 3/4 treatment-emergent adverse events, the most common being thrombocytopenia (26.3%) and hypertension (21.1%). Five patients (26.3%) had adverse events leading to treatment discontinuation. Conclusions: These results support the choice of niraparib 200 mg as the RP2D with AAP. The niraparib–AAP combination was tolerable in patients with mCRPC, with no new safety signals. An ongoing phase 3 study is further assessing this combination in patients with mCRPC. Trial registration no.: NCT02924766 (ClinicalTrials.gov).
- 18 February 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (2)
A Steerable Neuroendoscopic Instrument Using Compliant Contact-Aided Joints and Monolithic Articulation
This work presents the design of an articulate neuroendoscopic instrument (ANI), a handheld tool for use in minimally invasive neurosurgery. The instrument consists of a handle and a steerable tube-shaft with a distal end-effector. The design aims to increase the reach of surgeons operating through narrow channels within the center of the brain when approaching multiple targets from a single incision point. The steerable tube-shaft consists of a 1.6- mm notch-tube compliant joint mechanism augmented with contact-aids modeled after a gear geometry. The contact-aid geometry aims to address the performance tradeoff between stiffness, range-of-motion (RoM), and joint compactness for millimeter-scale notched-tube joints; it increases blocking force without sacrificing RoM. Finite element modeling (FEM) was used to refine design features, and the joint stiffness and RoM are assessed experimentally for three prototypes. The joint is incorporated into a tube-shaft instrument, and the assembled tool's stiffness properties are characterized. The prototype was then assessed in a validated neurosurgical simulator. An individual 1.24-mm outer-diameter notch-tube compliant joint with gear contact-aids is capable of 30 deg maximum bending and can sustain a 0.55 N blocking force with 0.5 mm displacement. A functional instrument shaft with a 15.5- mm-long articulating section was constructed from three joints in series with an external flexible stainless-steel sheath. It achieves a 6.7-mm bending radius at 75 deg maximum bending angle. In preclinical testing with an endoscopic third ventriculostomy and endoscopic tumor biopsy (ETV-ETB) simulator, the tool successfully completes the biopsy and fenestration maneuvers from a single burr-hole entry point. The ANI prototype uses contact-aid geometry incorporated into a compliant nitinol notched-tube joint to produce an articulate biopsy instrument for minimally invasive neurosurgical applications.
- 18 February 2020
- Published by ASME International in Journal of Medical Devices
- Vol. 14 (2)
A Steerable Neuroendoscopic Instrument Using Compliant Contact-Aided Joints and Monolithic Articulation
This work presents the design of an articulate neuroendoscopic instrument (ANI), a handheld tool for use in minimally invasive neurosurgery. The instrument consists of a handle and a steerable tube-shaft with a distal end-effector. The design aims to increase the reach of surgeons operating through narrow channels within the center of the brain when approaching multiple targets from a single incision point. The steerable tube-shaft consists of a 1.6- mm notch-tube compliant joint mechanism augmented with contact-aids modeled after a gear geometry. The contact-aid geometry aims to address the performance tradeoff between stiffness, range-of-motion (RoM), and joint compactness for millimeter-scale notched-tube joints; it increases blocking force without sacrificing RoM. Finite element modeling (FEM) was used to refine design features, and the joint stiffness and RoM are assessed experimentally for three prototypes. The joint is incorporated into a tube-shaft instrument, and the assembled tool's stiffness properties are characterized. The prototype was then assessed in a validated neurosurgical simulator. An individual 1.24-mm outer-diameter notch-tube compliant joint with gear contact-aids is capable of 30 deg maximum bending and can sustain a 0.55 N blocking force with 0.5 mm displacement. A functional instrument shaft with a 15.5- mm-long articulating section was constructed from three joints in series with an external flexible stainless-steel sheath. It achieves a 6.7-mm bending radius at 75 deg maximum bending angle. In preclinical testing with an endoscopic third ventriculostomy and endoscopic tumor biopsy (ETV-ETB) simulator, the tool successfully completes the biopsy and fenestration maneuvers from a single burr-hole entry point. The ANI prototype uses contact-aid geometry incorporated into a compliant nitinol notched-tube joint to produce an articulate biopsy instrument for minimally invasive neurosurgical applications.
- 7 May 2018
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 46 (10) , 1437-1449
Design, Modelling and Teleoperation of a 2 mm Diameter Compliant Instrument for the da Vinci Platform
This work explores the feasibility of creating and accurately controlling an instrument for robotic surgery with a 2 mm diameter and a three degree-of-freedom (DoF) wrist which is compatible with the da Vinci platform. The instrument’s wrist is composed of a two DoF bending notched-nitinol tube pattern, for which a kinematic model has been developed. A base mechanism for controlling the wrist is designed for integration with the da Vinci Research Kit. A basic teleoperation task is successfully performed using two of the miniature instruments. The performance and accuracy of the instrument suggest that creating and accurately controlling a 2 mm diameter instrument is feasible and the design and modelling proposed in this work provide a basis for future miniature instrument development.
- 7 May 2018
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 46 (10) , 1437-1449
Design, Modelling and Teleoperation of a 2 mm Diameter Compliant Instrument for the da Vinci Platform
This work explores the feasibility of creating and accurately controlling an instrument for robotic surgery with a 2 mm diameter and a three degree-of-freedom (DoF) wrist which is compatible with the da Vinci platform. The instrument’s wrist is composed of a two DoF bending notched-nitinol tube pattern, for which a kinematic model has been developed. A base mechanism for controlling the wrist is designed for integration with the da Vinci Research Kit. A basic teleoperation task is successfully performed using two of the miniature instruments. The performance and accuracy of the instrument suggest that creating and accurately controlling a 2 mm diameter instrument is feasible and the design and modelling proposed in this work provide a basis for future miniature instrument development.
- Open Access
- 20 December 2017
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 10 (1) , 015001
Design of a Contact-Aided Compliant Notched-Tube Joint for Surgical Manipulation in Confined Workspaces
This work presents a novel miniature contact-aided compliant joint mechanism that can be integrated into millimeter-sized manual or robotic surgical instruments. The design aims to address the trade-off between notched-tube compliant joints' range of motion and stiffness, while also ensuring a compact form factor. The mechanism is constructed from a nitinol tube with asymmetric cutouts and is actuated in bending by a cable. The innovative feature of this design is the incorporation of a contact aid into the notched-tube topology, which acts to both increase the stiffness of the joint and change the shape that it undertakes during bending. Using finite element modeling (FEM) techniques, we present a sensitivity analysis investigating how the performance of this contact-aided compliant mechanism (CCM) is affected by its geometry, and derive a kinematics and statics model for the joint. The FEM simulations and the kinematic and static models are compared to experimental results. The design and modeling presented in this study can be used to develop new miniature dexterous instruments, with a particular emphasis on applications in minimally invasive neurosurgery.
- 20 December 2017
- Published by ASME International in Journal of Mechanisms and Robotics
- Vol. 10 (1) , 015001
Open AccessDesign of a Contact-Aided Compliant Notched-Tube Joint for Surgical Manipulation in Confined Workspaces
This work presents a novel miniature contact-aided compliant joint mechanism that can be integrated into millimeter-sized manual or robotic surgical instruments. The design aims to address the trade-off between notched-tube compliant joints' range of motion and stiffness, while also ensuring a compact form factor. The mechanism is constructed from a nitinol tube with asymmetric cutouts and is actuated in bending by a cable. The innovative feature of this design is the incorporation of a contact aid into the notched-tube topology, which acts to both increase the stiffness of the joint and change the shape that it undertakes during bending. Using finite element modeling (FEM) techniques, we present a sensitivity analysis investigating how the performance of this contact-aided compliant mechanism (CCM) is affected by its geometry, and derive a kinematics and statics model for the joint. The FEM simulations and the kinematic and static models are compared to experimental results. The design and modeling presented in this study can be used to develop new miniature dexterous instruments, with a particular emphasis on applications in minimally invasive neurosurgery.
- 9 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics & Automation Magazine
- Vol. 24 (2) , 24-33
Miniaturized Instruments for the da Vinci Research Kit: Design and Implementation of Custom Continuum Tools
The da Vinci Surgical System is a commercially available surgical robotics platform used to perform more than 450,000 surgeries annually, primarily for gynecological and urological procedures [1]. This technology enhances the surgeon's dexterity through the use of a multiarm robot with wristed instruments that enter a patient's body through small incisions. However, the size of existing instruments (5-8 mm in shaft diameter) has prevented the adoption of the da Vinci system in areas such as neurosurgery, head and neck surgery, and pediatrics [2], [3]. These applications require high dexterity in small, confined workspaces, and, therefore, new miniaturized tools are needed [4].
- 9 May 2017
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Robotics & Automation Magazine
- Vol. 24 (2) , 24-33
Miniaturized Instruments for the da Vinci Research Kit: Design and Implementation of Custom Continuum Tools
The da Vinci Surgical System is a commercially available surgical robotics platform used to perform more than 450,000 surgeries annually, primarily for gynecological and urological procedures [1]. This technology enhances the surgeon's dexterity through the use of a multiarm robot with wristed instruments that enter a patient's body through small incisions. However, the size of existing instruments (5-8 mm in shaft diameter) has prevented the adoption of the da Vinci system in areas such as neurosurgery, head and neck surgery, and pediatrics [2], [3]. These applications require high dexterity in small, confined workspaces, and, therefore, new miniaturized tools are needed [4].