STSodai Tanaka

Sodai Tanaka

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Sodai Tanaka has a total of 89 co-authors. Here are the top co-authors by number of shared publications:

  • Taku Inaniwa

    Department of Accelerator and Medical Physics, National Institutes for Quantum Science and Technology, 4-9-1 Anagawa, Inage-ku, Chiba 263-8555, Chiba, 263-8555, JAPAN

    4 shared publications
  • Akito Saito

    Department of Radiation Oncology, Institute of Biomedical & Health Sciences, Hiroshima University , Hiroshima , Japan

    2 shared publications
  • Daisuke Kawahara

    Department of Radiation Oncology, Graduate School of Biomedical Health Sciences, Hiroshima University, Hiroshima, Japan

    2 shared publications
  • Jiayao Sun

    National Institutes for Quantum Science and Technology, 4-9-1, Anagawa, Inage-ku, Chiba, Chiba Prefecture, 263-8555, JAPAN

    2 shared publications
  • Masato Tsuneda

    Medical and Dental Sciences Course, Graduate School of Biomedical & Health Sciences, Hiroshima University , Hiroshima , Japan

    2 shared publications
  • Shuichi Ozawa

    Department of Radiation Oncology Graduate School of Biomedical and Health Sciences Hiroshima University Hiroshima Japan

    2 shared publications

Latest Publications

  • Investigation of Graphene as a Shielding Material for Space Environments

    by Abdelrahman M. BaniHani, Dylan Hill, Vladimir Pan, James Vohradsky, Daniel Bennett, David Bolst, Stefania Peracchi, Marco Povoli, Angela Kok, Sung Hyun Lee, et al.

    This work investigates the radiation shielding efficiency of High-Density Polyethylene (HDPE)/Graphene, carbon fibre, and polyethylene materials. The composite HDPE Graphene was studied both as a substitute layer in the ISS wall/Columbus shielding configuration and as an additional layer serving as intravehicular spacesuits for astronauts. The average quality factors (Q) for 12C, 40Ar, and 56Fe ion beams were evaluated using the Silicon-On-Insulator (SOI) Mushroom microdosimeter behind various realistic ISS Columbus wall configurations at the Heavy Ion Medical Accelerator in Chiba (HIMAC), Japan. Moreover, the individual dose equivalent, Hp(10), was calculated for astronaut personal monitoring. The SOI microdosimeter’s response to the monoenergetic ion beams behind these shielding configurations enabled comparison of the shielding efficiencies for the tested materials. The results indicate that the shielding efficiency of HDPE Graphene is similar to that of carbon fibre and Kevlar.

  • Neon ion radiotherapy: physics and biology

    by Stewart Mein, Takamitsu Masuda, Koki Kasamatsu, Taku Nakaji, Yusuke Nomura, Jiayao Sun, Ken Katagiri, Yoshiyuki Iwata, Nobuyuki Kanematsu, Kota Mizushima, et al.

    Neon ion ( 20 Ne) beam radiotherapy was one of the primary particle therapy candidates investigated during the clinical trials beginning in the 1970s at the Lawrence Berkely National Laboratory (LBNL), which shut down in the early 1990s. Currently, therapeutic neon ion beams are available at only one clinical facility worldwide, the National Institutes for Quantum Science and Technology (QST) in Chiba, Japan. Recently, neon ion beams were commissioned at QST Hospital as part of the first clinical multi-ion therapy (MIT) program, which aims to improve clinical outcomes by escalating higher linear energy transfer (LET) radiation in the tumor for treating therapy-resistant disease. With the advancement of high-precision scanning delivery techniques, neon ion treatments in the present day could be delivered more safely and with greater precision compared to the first and only clinical application decades prior at LBNL using passive scattering technology. Despite their promising results, preclinical investigations of neon ions are scarce outside of Japan and further independent studies are needed. Clinically, neon ion therapy may offer benefits in treating certain malignancies by escalating LET in the tumor, but its limited availability and high costs restrict its current use and adoption. Studies have shown that 20 Ne or multi-ion mixtures ( 4 He, 12 C, 16 O and/or 20 Ne) can provide larger degrees of freedom in optimization of dose, LET and relative biological effectiveness, otherwise unattainable with other single ion techniques. Neon ion beams are under investigation in the ongoing MIT clinical trials which will establish their broader applicability. In this review, the technology, physics, radiobiology, and potential clinical applications of neon ion beams are outlined. The status of therapeutic neon ion beams is provided while discussing future research and clinical directions, including technological development of novel particle therapy delivery techniques, such as multi-ion, mini-beam, arc, and ultra-high dose rate.


  • In-beam range determination using an OpenPET system for helium, carbon, oxygen, and neon ion beams

    by Jiayao Sun, Takamitsu Masuda, Hideaki Tashima, Chie Toramatsu, Akram Hamato, Taiga Yamaya, Sodai Tanaka, Koki Kasamatsu, Stewart Mein, Taku Inaniwa

    Objective. At the National Institutes for Quantum Science and Technology, helium, carbon, oxygen, and neon ion beams are utilized together in multi-ion therapy to enhance the therapeutic efficacy of charged-particle therapy. When accelerated ions traverse a medium, a fraction will undergo nuclear interactions, some of which, in turn, produce positron-emitting nuclei. This study investigates the accuracy of ion beam range determination using the annihilation photons emitted from the nuclei measured with an in-house online PET system (OpenPET). Approach. A polymethyl methacrylate phantom was irradiated separately with un-scanned helium, carbon, oxygen, and neon ion beams to 1.5 Gy physical doses at the Bragg peak. Annihilation photons were measured with OpenPET. Each irradiation was simulated using the Particle and Heavy Ion Transport code System (PHITS) to obtain the predicted annihilation photon distributions. The range of beams in the phantom was determined by comparing measured and simulated planar-integrated annihilation photon distributions (PIADs). Fisher information was used to quantify the expected accuracy of range determinations. Main results. The measured PIADs showed good agreement with the simulated PIADs for carbon, oxygen, and neon ions. However, discrepancies were observed for helium ions, likely due to uncertainties in the cross section data used in PHITS. The range was determined within an accuracy of 2 mm for four ion species for the measurement times longer than 3 min. Neon ions had the most Fisher information for measurement times shorter than 135 s, whereas beyond that, oxygen ions had the most information, offering the highest range determination accuracy. Significance. The range was determined within an accuracy of 2 mm for helium, carbon, oxygen, and neon ion beams by the OpenPET measurements of 180 s. Among the four ion species, neon ions showed the highest accuracy in range determination within 135 s, while oxygen ions performed best for measurement times beyond 135 s.


  • Method for fabricating a mesh ripple filter for charged-particle therapy

    by Sodai Tanaka, Taku Inaniwa

    Objective. A simple, low-cost ripple filter consisting of multiple mesh sheets (mRiFi) was previously developed to reproducibly widen the Bragg peak of heavy-ion beams. To fabricate the mRiFi, the mRiFi parameters such as the wire material, wire diameter, wire spacing, and number of mesh sheets had to be determined. However, it was unclear how these parameters contribute to shifting and widening of the Bragg peak as well as to lateral spreading of the beam passing through the mRiFi. The purposes of this study were to clarify the contributions and to propose a recipe for fabricating a mRiFi with the desired performance values. Approach. We established an analytical calculation method to estimate shifting and widening of the Bragg peak and lateral spreading of heavy-ion beams passing through the mRiFi for given mRiFi parameter values. We also performed Monte Carlo simulations to validate the analytical calculation method. The recipe for fabricating the mRiFi with desired performances was established based on the analytical calculation method. Using the recipe, we fabricated the mRiFi for multi-ion therapy and evaluated its performance through demonstration experiments with helium-, carbon-, oxygen-, and neon-ion beams. Main results. The difference between the results of the Monte Carlo simulation and the analytical calculation was less than 0.4 mm for the peak shift, 0.15 mm for the peak width, and less than 0.11 mm for the lateral beam size which validated the analytical calculation method. The experimentally observed shift and width of the Bragg peak were consistent with the analytical calculations. Significance. We proposed a method to determine mRiFi parameters for fabricating a mRiFi with a desired performance, i.e. adequate widening of the Bragg peak with an acceptable peak shift and lateral beam spread. The proposed method allows anyone to fabricate a simple and low-cost mRiFi satisfying desired specifications.


  • Development of ripple filter composed of metal mesh for charged-particle therapy

    by Sodai Tanaka, Taku Inaniwa, Shunya Matsuba

    Objective. In charged-particle therapy, a ripple filter (RiFi) is used for broadening the Bragg peak in the beam direction. A conventional RiFi consists of plates with a fine ridge and groove structure. The construction of the RiFi has been a time-consuming and costly task. In this study, we developed a simple RiFi made of multi-layered metal mesh (mRiFi), with which the Bragg peak is broadened due to structural randomness, similar to what occurs for the already proposed RiFi with porous material. Approach . The mRiFi was constructed by stacking commercially available metal meshes at random positions and angles. The mRiFi was inexpensive to fabricate due to its high availability and low machining accuracy. The Bragg peak width modulated by the mRiFi can be uniquely determined by the wire material, wire diameter, wire-to-wire spacing of the metal mesh, and the number of mesh sheets. We fabricated four mRiFis consisting of 10, 20, 30, and 40 layers of stainless steel meshes with a wire diameter of 0.1 mm and a wire-to-wire spacing of 0.508 mm. Main results. Using the mRiFis consisting of 10, 20, 30, and 40 mesh sheets, we succeeded in broadening the Bragg peak following the normal distribution with the respective standard deviation σ values of 0.83, 1.15, 1.41, and 1.56 mm in water in experimental planar-integrated depth dose measurements with 140.3 MeV u −1 carbon-ion beams. The effect of range broadening with the mRiFi was independent of its lateral position, and the measurement of the surface dose using radiochromic films showed no severe inhomogeneity with a homogeneity index greater than 0.3 caused by the mRiFis. Significance. The developed mRiFi can be used as a RiFi in charged-particle therapy. The mRiFi has three advantages: high supply stability of the material for manufacturing it, easy fabrication, and low cost.


  • First experimental results of gated proton imaging using x-ray fluoroscopy to detect a fiducial marker

    by Sodai Tanaka, Naoki Miyamoto, Yuto Matsuo, Takaaki Yoshimura, Seishin Takao, Taeko Matsuura

    Increasing numbers of proton imaging research studies are being conducted for accurate proton range determination in proton therapy treatment planning. However, there is no proton imaging system that deals with motion artifacts. In this study, a gated proton imaging system was developed and the first experimental results of proton radiography (pRG) were obtained for a moving object without motion artifacts. A motion management system using dual x-ray fluoroscopy for detecting a spherical gold fiducial marker was introduced and the proton beam was gated in accordance with the motion of the object. To demonstrate the performance of the gated proton imaging system, gated pRG images of a moving phantom were acquired experimentally, and the motion artifacts clearly were diminished. Also, the factors causing image deteriorations were evaluated focusing on the new gating system developed here, and the main factor was identified as the latency (with a maximum value of 93 ms) between the ideal gating signal according to the actual marker position and the actual gating signal. The possible deterioration due to the latency of the proton imaging system and proton beam irradiation was small owing to appropriate setting of the time structure.


  • Calibrated uncertainty estimation for interpretable proton computed tomography image correction using Bayesian deep learning

    by Yusuke Nomura, Sodai Tanaka, Jeff Wang, Hiroki Shirato, Shinichi Shimizu, Lei Xing

    Integrated-type proton computed tomography (pCT) measures proton stopping power ratio (SPR) images for proton therapy treatment planning, but its image quality is degraded due to noise and scatter. Although several correction methods have been proposed, techniques that include estimation of uncertainty are limited. This study proposes a novel uncertainty-aware pCT image correction method using a Bayesian convolutional neural network (BCNN). A DenseNet-based BCNN was constructed to predict both a corrected SPR image and its uncertainty from a noisy SPR image. A total 432 noisy SPR images of 6 non-anthropomorphic and 3 head phantoms were collected with Monte Carlo simulations, while true noise-free images were calculated with known geometric and chemical components. Heteroscedastic loss and deep ensemble techniques were performed to estimate aleatoric and epistemic uncertainties by training 25 unique BCNN models. 200-epoch end-to-end training was performed for each model independently. Feasibility of the predicted uncertainty was demonstrated after applying two post-hoc calibrations and calculating spot-specific path length uncertainty distribution. For evaluation, accuracy of head SPR images and water-equivalent thickness (WET) corrected by the trained BCNN models was compared with a conventional method and non-Bayesian CNN model. BCNN-corrected SPR images represent noise-free images with high accuracy. Mean absolute error in test data was improved from 0.263 for uncorrected images to 0.0538 for BCNN-corrected images. Moreover, the calibrated uncertainty represents accurate confidence levels, and the BCNN-corrected calibrated WET was more accurate than non-Bayesian CNN with high statistical significance. Computation time for calculating one image and its uncertainties with 25 BCNN models is 0.7 s with a consumer grade GPU. Our model is able to predict accurate pCT images as well as two types of uncertainty. These uncertainties will be useful to identify potential cause of SPR errors and develop a spot-specific range margin criterion, toward elaboration of uncertainty-guided proton therapy.


  • Proton dose calculation based on converting dual-energy CT data to stopping power ratio (DEEDZ-SPR): a beam-hardening assessment

    by Sodai Tanaka, Yoshiyuki Noto, Satoru Utsunomiya, Takaaki Yoshimura, Taeko Matsuura, Masatoshi Saito

    To achieve an accurate stopping power ratio (SPR) prediction in particle therapy treatment planning, we previously proposed a simple conversion to the SPR from dual-energy (DE) computed tomography (CT) data via electron density and effective atomic number ( Z eff ) calibration (DEEDZ-SPR). This study was conducted to carry out an initial implementation of the DEEDZ-SPR conversion method with a clinical treatment planning system (TPS; VQA, Hitachi Ltd., Tokyo) for proton beam therapy. Consequently, this paper presents a proton therapy plan for an anthropomorphic phantom to evaluate the stability of the dose calculations obtained by the DEEDZ-SPR conversion against the variation of the calibration phantom size. Dual-energy x-ray CT images were acquired using a dual-source CT (DSCT) scanner. A single-energy CT (SECT) scan using the same DSCT scanner was also performed to compare the DEEDZ-SPR conversion with the SECT-based SPR (SECT-SPR) conversion. The scanner-specific parameters necessary for the SPR calibration were obtained from the CT images of tissue substitutes in a calibration phantom. Two calibration phantoms with different sizes (a 33 cm diameter phantom and an 18 cm diameter phantom) were used for the SPR calibrations to investigate the beam-hardening effect on dosimetric uncertainties. Each set of calibrated SPR data was applied to the proton therapy plan designed using the VQA TPS with a pencil beam algorithm for the anthropomorphic phantom. The treatment plans with the SECT-SPR conversion exhibited discrepancies between the dose distributions and the dose-volume histograms (DVHs) of the 33 cm and 18 cm phantom calibrations. In contrast, the corresponding dose distributions and the DVHs obtained using the DEEDZ-SPR conversion method coincided almost perfectly with each other. The DEEDZ-SPR conversion appears to be a promising method for providing proton dose plans that are stable against the size variations of the calibration phantom and the patient.


  • Open Access

    Quantitative analysis of treatments using real‐time image gated spot‐scanning with synchrotron‐based proton beam therapy system log data

    by Takaaki Yoshimura, Shinichi Shimizu, Takayuki Hashimoto, Kentaro Nishioka, Norio Katoh, Hiroshi Taguchi, Koichi Yasuda, Taeko Matsuura, Seishin Takao, Masaya Tamura, et al.

    A synchrotron‐based real‐time image gated spot‐scanning proton beam therapy (RGPT) system with inserted fiducial markers can irradiate a moving tumor with high accuracy. As gated treatments increase the beam delivery time, this study aimed to investigate the frequency of intra‐field adjustments corresponding to the baseline shift or drift and the beam delivery efficiency of a synchrotron‐based RGPT system. Data from 118 patients corresponding to 127 treatment plans and 2810 sessions between October 2016 and March 2019 were collected. We quantitatively analyzed the proton beam delivery time, the difference between the ideal beam delivery time based on a simulated synchrotron magnetic excitation pattern and the actual treatment beam delivery time, frequency corresponding to the baseline shift or drift, and the gating efficiency of the synchrotron‐based RGPT system according to the proton beam delivery machine log data. The mean actual beam delivery time was 7.1 min, and the simulated beam delivery time in an ideal environment with the same treatment plan was 2.9 min. The average difference between the actual and simulated beam delivery time per session was 4.3 min. The average frequency of intra‐field adjustments corresponding to baseline shift or drift and beam delivery efficiency were 21.7% and 61.8%, respectively. Based on our clinical experience with a synchrotron‐based RGPT system, we determined the frequency corresponding to baseline shift or drift and the beam delivery efficiency using the beam delivery machine log data. To maintain treatment accuracy within ± 2.0 mm, intra‐field adjustments corresponding to baseline shift or drift were required in approximately 20% of cases. Further improvements in beam delivery efficiency may be realized by shortening the beam delivery time.


  • Open Access

    Automatic contrast medium extraction system using electron density data with dual-energy CT

    by Daisuke Kawahara, Shuichi Ozawa, Sodai Tanaka, Kazushi Yokomachi, Toru Higaki, Akito Saito, Kentaro Miki, Chikako Fujioka, Yoshimi Ohno, Tomoki Kimura, et al.

    Objectives:The purpose of the current study is to create a contrast medium extraction method using raw-data-based electron density (rED) and CT number from dual-energy CT (DECT) for automatic delineation of the contrast region.Methods:A CT-ED phantom containing tissue-equivalent inserts and an acrylic phantom with an iodinated contrast medium were scanned by DECT. The contrast medium extraction system was created using Python. The accuracy of the contrast medium extraction was evaluated by measuring the diameter in terms of the full width at half maximum (FWHM) and the ratio of the volume (ROV).Results:Mean-2SD CT numbers and the difference of the CT numbers (DCT) of the contrast medium at 0–130 mg ml−1 contrast medium concentration and the bone materials were more than −33 HU and −20 HU, respectively. In the correlation of rED and CT number, the gradient with the contrast medium phantom was greater than that with the CT-ED phantom. The accuracy of the contrast medium at 80 kV/135 kV and 100 kV/135 kV tub...