Quantitative analysis of treatments using real‐time image gated spot‐scanning with synchrotron‐based proton beam therapy system log data
Authors:
- Takaaki YoshimuraTYTakaaki Yoshimura
- Shinichi ShimizuSSShinichi Shimizu
- Takayuki HashimotoTHTakayuki Hashimoto
- Kentaro NishiokaKNKentaro Nishioka
- Norio KatohNKNorio Katoh
- Hiroshi TaguchiHTHiroshi Taguchi
- Koichi YasudaKYKoichi Yasuda
- Taeko MatsuuraTMTaeko Matsuura
- Seishin TakaoSTSeishin Takao
- Masaya TamuraMTMasaya Tamura
- Sodai TanakaSTSodai Tanaka
- Yoichi M. ItoYIYoichi M. Ito
Open Access
- 5 November 2020
- journal article
- research article
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 21 (12) , 10-19
Abstract
A synchrotron‐based real‐time image gated spot‐scanning proton beam therapy (RGPT) system with inserted fiducial markers can irradiate a moving tumor with high accuracy. As gated treatments increase the beam delivery time, this study aimed to investigate the frequency of intra‐field adjustments corresponding to the baseline shift or drift and the beam delivery efficiency of a synchrotron‐based RGPT system. Data from 118 patients corresponding to 127 treatment plans and 2810 sessions between October 2016 and March 2019 were collected. We quantitatively analyzed the proton beam delivery time, the difference between the ideal beam delivery time based on a simulated synchrotron magnetic excitation pattern and the actual treatment beam delivery time, frequency corresponding to the baseline shift or drift, and the gating efficiency of the synchrotron‐based RGPT system according to the proton beam delivery machine log data. The mean actual beam delivery time was 7.1 min, and the simulated beam delivery time in an ideal environment with the same treatment plan was 2.9 min. The average difference between the actual and simulated beam delivery time per session was 4.3 min. The average frequency of intra‐field adjustments corresponding to baseline shift or drift and beam delivery efficiency were 21.7% and 61.8%, respectively. Based on our clinical experience with a synchrotron‐based RGPT system, we determined the frequency corresponding to baseline shift or drift and the beam delivery efficiency using the beam delivery machine log data. To maintain treatment accuracy within ± 2.0 mm, intra‐field adjustments corresponding to baseline shift or drift were required in approximately 20% of cases. Further improvements in beam delivery efficiency may be realized by shortening the beam delivery time.Keywords
Funding Information
- Japan Society for the Promotion of Science (JP18K15577, JP18H02758)
This publication has 45 references indexed in Scilit:
- A Proton Beam Therapy System Dedicated to Spot-Scanning Increases Accuracy with Moving Tumors by Real-Time Imaging and Gating and Reduces Equipment SizePLOS ONE, 2014
- Adequate margin definition for scanned particle therapy in the incidence of intrafractional motionPhysics in Medicine & Biology, 2013
- Integration of a real‐time tumor monitoring system into gated proton spot‐scanning beam therapy: An initial phantom study using patient tumor trajectory dataMedical Physics, 2013
- Development of the compact proton beam therapy system dedicated to spot scanning with real-time tumor-tracking technologyAIP Conference Proceedings, 2013
- Respiratory liver motion estimation and its effect on scanned proton beam therapyPhysics in Medicine & Biology, 2012
- Scanned proton radiotherapy for mobile targets—the effectiveness of re-scanning in the context of different treatment planning approaches and for different motion characteristicsPhysics in Medicine & Biology, 2011
- Efficiency of respiratory-gated delivery of synchrotron-based pulsed proton irradiationPhysics in Medicine & Biology, 2008
- Quantitative Assessment of Range Fluctuations in Charged Particle Lung IrradiationInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2008
- Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2002
- Effects of respiratory motion on dose uniformity with a charged particle scanning methodPhysics in Medicine & Biology, 1992