Sabrina Tietze
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sabrina Tietze has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Klaus Stefan Drese
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbrauhaus 1b, 96450 Coburg, Germany
2 shared publications - Alexander Backer
Institute for Sensor and Actuator Technology, Coburg University of Applied Science, 96450 Coburg, Germany
1 shared publication - Ferdinand Singer
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbrauhaus 1b, 96450 Coburg, Germany
1 shared publication Gerhard Lindner
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbrauhaus 1b, 96450 Coburg, Germany
1 shared publication- Gerhard Lindner
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences, Am Hofbrauhaus 1, 96450 Coburg, Germany
1 shared publication - Gerhard Lindner
Institute of Sensor and Actuator Technology, Coburg University of Applied Sciences and Arts, Am Hofbrauhaus 1b, 96450 Coburg, Germany
1 shared publication
Latest Publications
- Open Access
- 1 January 2024
- Published by AMA Service GmbH
- p. 306-312
D1.3 - Bestimmung der Materialeigenschaften von Rohren und innen liegenden Schichten mittels geführten akustischen Wellen
Zusammenfassung Für die nichtinvasive Durchflussmessung werden meist Ultraschallsensoren verwendet, die reversibel an das zu untersuchende Rohrsystem angebaut werden. Die Messgenauigkeit dieser Sensoren wird durch mögliche Ablagerungen im Rohrinneren beeinflusst. In dem hier vorgestellten Forschungsvorhaben, soll es mit Hilfe eines ultraschallbasierten Messverfahren möglich sein, sowohl die Materialeigenschaften und Wandstärke des Rohres direkt zu ermitteln als auch eventuell vorhandene Schichten im Rohrinneren zu detektieren und
- 1 January 2024
- Published by AMA Service GmbH
- p. 306-312
Open AccessD1.3 - Bestimmung der Materialeigenschaften von Rohren und innen liegenden Schichten mittels geführten akustischen Wellen
Zusammenfassung Für die nichtinvasive Durchflussmessung werden meist Ultraschallsensoren verwendet, die reversibel an das zu untersuchende Rohrsystem angebaut werden. Die Messgenauigkeit dieser Sensoren wird durch mögliche Ablagerungen im Rohrinneren beeinflusst. In dem hier vorgestellten Forschungsvorhaben, soll es mit Hilfe eines ultraschallbasierten Messverfahren möglich sein, sowohl die Materialeigenschaften und Wandstärke des Rohres direkt zu ermitteln als auch eventuell vorhandene Schichten im Rohrinneren zu detektieren und
- Open Access
- 1 November 2019
- Published by Elsevier in Ultrasonics
- Vol. 99, 105955
Visualization of the interaction of guided acoustic waves with water by light refractive vibrometry
- 1 November 2019
- Published by Elsevier in Ultrasonics
- Vol. 99, 105955
Open AccessVisualization of the interaction of guided acoustic waves with water by light refractive vibrometry
- Open Access
Monitoring of Soft Deposition Layers in Liquid-Filled Tubes with Guided Acoustic Waves Excited by Clamp-on Transducers
The monitoring of liquid-filled tubes with respect to the formation of soft deposition layers such as biofilms on the inner walls calls for non-invasive and long-term stable sensors, which can be attached to existing pipe structures. For this task a method is developed, which uses an ultrasonic clamp-on device. This method is based on the impact of such deposition layers on the propagation of circumferential guided waves on the pipe wall. Such waves are partly converted into longitudinal compressional waves in the liquid, which are back-converted to guided waves in a circular cross section of the pipe. Validating this approach, laboratory experiments with gelatin deposition layers on steel tubes exhibited a distinguishable sensitivity of both wave branches with respect to the thickness of such layers. This allows the monitoring of the layer growth.
Open AccessMonitoring of Soft Deposition Layers in Liquid-Filled Tubes with Guided Acoustic Waves Excited by Clamp-on Transducers
The monitoring of liquid-filled tubes with respect to the formation of soft deposition layers such as biofilms on the inner walls calls for non-invasive and long-term stable sensors, which can be attached to existing pipe structures. For this task a method is developed, which uses an ultrasonic clamp-on device. This method is based on the impact of such deposition layers on the propagation of circumferential guided waves on the pipe wall. Such waves are partly converted into longitudinal compressional waves in the liquid, which are back-converted to guided waves in a circular cross section of the pipe. Validating this approach, laboratory experiments with gelatin deposition layers on steel tubes exhibited a distinguishable sensitivity of both wave branches with respect to the thickness of such layers. This allows the monitoring of the layer growth.
- 6 September 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1474 (1) , 391
Droplet propulsion on non-piezoelectric substrates induced by Lamb waves
Microliter droplet can be propelled on a non-piezoelectric substrate, on which antisymmetrical zero order Lamb waves with 1 MHz center frequency are propagating. Different droplet volume has different ratio of absorbed power, which is described by droplet propulsion distance/electrical input power. Moreover, with increasing droplet volume (10μl, 20μl, 50μl), the excitation frequency (1.03 MHz, 1.04 MHz, 1.06 MHz) must be slightly increased, for the optimization of the propulsion process.
- 6 September 2012
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 1474 (1) , 391
Droplet propulsion on non-piezoelectric substrates induced by Lamb waves
Microliter droplet can be propelled on a non-piezoelectric substrate, on which antisymmetrical zero order Lamb waves with 1 MHz center frequency are propagating. Different droplet volume has different ratio of absorbed power, which is described by droplet propulsion distance/electrical input power. Moreover, with increasing droplet volume (10μl, 20μl, 50μl), the excitation frequency (1.03 MHz, 1.04 MHz, 1.06 MHz) must be slightly increased, for the optimization of the propulsion process.