G. Refsdal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
G. Refsdal has a total of 1 co-authors. Here are the top co-authors by number of shared publications:
- E. Øiseth
SINTEF Building and Infrastructure, Department for Rock and Soil Mechanics, Trondheim, Norway
1 shared publication
Latest Publications
- 14 July 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1-11
Lightweight Aggregates as Frost Insulation in Roads — Design Chart
Frost heave and thawing, resulting in deformations and reduced bearing capacity, cause major maintenance costs of the roads in the Nordic countries. The most common frost protection method in Norway is to increase the layer thickness of crushed rock. In addition has extruded polystyrene (XPS) been used since 1965, but this has gradually been reduced the last 20 years. Light expanded clay aggregate has regularly been used as frost protection for other civil engineering applications such as railways and buildings, and is occasionally also used for pavements. Lately also foam glass aggregate has become an option. To optimize the design, SINTEF has performed a number of numerical analyses and developed design charts that give the required layer thickness of frost insulation. The numerical analyses showed that the frost protection layer using expanded clay or foam glass aggregate should be 4–5 times thicker than a frost protection of extruded polystyrene.
- 14 July 2006
- Published by American Society of Civil Engineers (ASCE)
- p. 1-11
Lightweight Aggregates as Frost Insulation in Roads — Design Chart
Frost heave and thawing, resulting in deformations and reduced bearing capacity, cause major maintenance costs of the roads in the Nordic countries. The most common frost protection method in Norway is to increase the layer thickness of crushed rock. In addition has extruded polystyrene (XPS) been used since 1965, but this has gradually been reduced the last 20 years. Light expanded clay aggregate has regularly been used as frost protection for other civil engineering applications such as railways and buildings, and is occasionally also used for pavements. Lately also foam glass aggregate has become an option. To optimize the design, SINTEF has performed a number of numerical analyses and developed design charts that give the required layer thickness of frost insulation. The numerical analyses showed that the frost protection layer using expanded clay or foam glass aggregate should be 4–5 times thicker than a frost protection of extruded polystyrene.