Francisco F. Santos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Francisco F. Santos has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Amauri Oliveira
Universidade Federal da Bahia, Brasil
2 shared publications - Georgina M. Freitas
Universidade Federal de Campina Grande, Unidade Acadêmica de Engenharia Elétrica, Campina Grande - PB, Brazil
2 shared publications - Hassan Aboushady
Sorbonne Université, CNRS, LIP6, Paris, France
2 shared publications - Ligia S. Palma
Universidade Federal da Bahia, Departamento de Engenharia Elétrica, Salvador - BA, Brazil
2 shared publications - Raimundo Carlos Silvérios Freire
Department of Electrical Engineering, Federal University of Campina Grande, Campina Grande, Brazil
2 shared publications - Sebastian Yuri Cavalcanti Catunda
Graduate Program in Electrical and Computer Engineering (PPgEEC), Federal University of Rio Grande do Norte (UFRN), Natal, Brazil
2 shared publications
Latest Publications
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-6
A Constant Temperature Thermoresistive Sigma-Delta Anemometer
In this paper we propose a feedback measurement system, with thermoresistive sensor, based on sigma-delta modulation. The system uses a one-bit sigma-delta modulator for which a considerable part of the conversion functions is performed by a thermoresistive sensor. The sensor is modelled using the power balance principle and the constant temperature measurement method is employed. This transducer architecture is able to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation and fluid velocity. This paper presents simulations and validates the structure of the sigma-delta converter as an anemometer. The advantage to directly convert physical quantities to digital, with the sensor as part of the A to D converter, makes possible the implementation of this measurement system in an integrated circuit. Another advantage of the IC implementation of this structure is the possibility to reduce noise interference due to discrete component connections in a printed circuit board.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-6
A Constant Temperature Thermoresistive Sigma-Delta Anemometer
In this paper we propose a feedback measurement system, with thermoresistive sensor, based on sigma-delta modulation. The system uses a one-bit sigma-delta modulator for which a considerable part of the conversion functions is performed by a thermoresistive sensor. The sensor is modelled using the power balance principle and the constant temperature measurement method is employed. This transducer architecture is able to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation and fluid velocity. This paper presents simulations and validates the structure of the sigma-delta converter as an anemometer. The advantage to directly convert physical quantities to digital, with the sensor as part of the A to D converter, makes possible the implementation of this measurement system in an integrated circuit. Another advantage of the IC implementation of this structure is the possibility to reduce noise interference due to discrete component connections in a printed circuit board.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-5
Thermal Σ-Δ Modulator: Anemometer Performance Analysis
In this paper we propose a feedback architecture with a thermosensitive sensor, based on the thermal Σ-Δ principle to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation, fluid speed. This architecture uses a 1-bit Σ-Δ modulator for which a considerable part of the conversion functions is performed by a thermosensitive sensor. The sensor is modelled using the electrical equivalence principle and the constant temperature measurement method is applied. We present an analysis of the system performance, in terms of frequency response and system measurement resolution, of a 1-bit first-order Σ-Δ thermal modulator. It is shown that the system performance depends on the system oversampling ratio (OSR) and on the system transfer function pole and zero, which in turn, depends on the thermal and physical sensor characteristics and on the system operating conditions. This system is proposed as anemometer.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10915281,p. 1-5
Thermal Σ-Δ Modulator: Anemometer Performance Analysis
In this paper we propose a feedback architecture with a thermosensitive sensor, based on the thermal Σ-Δ principle to realize digital measurement of physical quantities that interacts with the sensor: temperature, thermal radiation, fluid speed. This architecture uses a 1-bit Σ-Δ modulator for which a considerable part of the conversion functions is performed by a thermosensitive sensor. The sensor is modelled using the electrical equivalence principle and the constant temperature measurement method is applied. We present an analysis of the system performance, in terms of frequency response and system measurement resolution, of a 1-bit first-order Σ-Δ thermal modulator. It is shown that the system performance depends on the system oversampling ratio (OSR) and on the system transfer function pole and zero, which in turn, depends on the thermal and physical sensor characteristics and on the system operating conditions. This system is proposed as anemometer.